Schneider Modicon M340 BMXP341000 is a Level 1 CPU processor module, designed for small and medium-sized industrial automation projects. It is equipped with 2048 kB memory, supports Modbus/Ethernet communication, and features expandability for 512 digital I/O points + 128 analog I/O points. Featuring compact structure, industrial-grade environmental adaptability and flexible communication performance, it is an ideal choice for manufacturing, энергия, water treatment and other industries. Following maintenance guidelines and troubleshooting manuals ensures long-term stable operation and cuts down system maintenance costs.
- Пояснение кода модели
| Модельный сегмент | Значение | Описание |
| BMX | Product Series Prefix | Identification of Schneider Modicon M340 series PLC products |
| P34 | Тип продукта | P stands for processor module; 34 represents M340 series |
| 1000 | Model Number | 1000 refers to basic CPU, supports Modbus communication, Макс. 512 digital I/O + 128 analog I/O |
| Нет суффикса | Стандартная версия | Without special suffix means standard temperature range (0~60°C) and IP20 protection degree |
| -С | Optional Suffix | Mark for special version in partial documents, generally refers to standard configuration |
- Core Specification Table
| Категория | Технические характеристики | Описание |
| Basic Configuration | Уровень 1 CPU processor of Modicon M340 series | Core control module for small & medium industrial automation systems |
| 1 × Modbus serial port (RS-485) | ||
| 1 × Ethernet port (Modbus/TCP) | ||
| Backplane bus connection, compatible with 11-slot rack | ||
| Memory Capacity | Total RAM: 2048 kB | Meets the demands of medium-scale control programs |
| Program memory: 1792 kB | ||
| Data memory: 128 kB | ||
| I/O Capacity | Макс. 512 digital I/O points (single rack) | Flexible expansion to fit projects of different scales |
| Макс. 66 analog I/O points (single rack) / 128 analog I/O points (multi-rack) | ||
| Distributed I/O: 63 Ethernet Modbus/TCP devices + 32 Modbus link devices | ||
| Communication Performance | Built-in Modbus RTU (serial) & Модбус TCP (Ethernet) | Compatible with mainstream industrial protocols, supports remote monitoring |
| Supports up to 2 local racks (основной + расширение) | ||
| Макс. serial baud rate: 115.2 кбит/с | ||
| Ethernet: 10/100Base-TX, RJ45 interface | ||
| Power Supply Parameters | Рабочее напряжение: 240 ВАК | Integrated with power system of M340 series racks |
| Typical power consumption: 10 Вт, Макс. 15 Вт | ||
| Power interface: Backplane power supply, не требуется дополнительная проводка | ||
| Физические параметры | Размеры: 102 × 130 × 39 мм | Компактный размер, suitable for standard industrial control cabinets |
| Масса: 0.2 кг | ||
| Монтаж: Special clip-type mounting for M340 racks | ||
| Параметры окружающей среды | Рабочая температура: 0~60°C | Excellent industrial environmental adaptability for harsh working conditions |
| Температура хранения: -40~70°C | ||
| Относительная влажность: 5~95% (неконденсирующийся) | ||
| Степень защиты: IP20 | ||
| Vibration resistance: 5~150 Гц, 0.5 mm peak-to-peak | ||
| Shock resistance: 15 г, 11 РС | ||
| Сертификаты | CE, UL/cUL, РоХС, МЭК 61131-2 | Compliant with international industrial standards, available for global market |
| Ordering Code | BMXP341000 | Standard model without special suffix |
III. Full Series Model List (M340 Series CPU Modules)
| Модель | Grade | Memory Capacity | Communication Interfaces | Макс. I/O Capacity | Основные характеристики |
| BMXP341000 | Уровень 1 | 2048 kB (1792/128) | 1 × Modbus serial + 1 × Ethernet | 512 Цифровой + 128 Analog | Basic type with Modbus communication |
| BMXP342000 | Уровень 2 | 4096 kB (3584/512) | 1 × Modbus serial + 1 × Ethernet | 1024 Цифровой + 256 Analog | Enhanced type with larger memory |
| BMXP343020 | Уровень 3 | 8192 kB (6912/1280) | 2 × Ethernet (routing supported) + 1 × Modbus serial | 2048 Цифровой + 512 Analog | Advanced type, dual Ethernet with routing function |
| BMXP343030 | Уровень 3 | 8192 kB (6912/1280) | 2 × Ethernet + 1 × Modbus serial + 1 × CANopen | 2048 Цифровой + 512 Analog | All-round type with CANopen bus support |
| BMXP344020 | Уровень 4 | 16384 kB (14336/2048) | 2 × Ethernet (routing supported) + 1 × Modbus serial | 4096 Цифровой + 1024 Analog | Flagship type with large memory and redundancy support |
- Replacement Comparison: Old & New Models / Peer Products
- Old and New Model Replacement
| Old Model | New Model | Major Upgrades |
| TSXP341000 | BMXP341000 | Upgraded to M340 series, backplane compatible, 30% performance improvement |
| Memory expanded to 2048 kB to support more I/O points | ||
| Built-in Ethernet port for stronger communication capability |
- Peer Product Comparison (Same-grade PLC CPU Modules)
| Модель | Бренд | Memory Capacity | Communication Interfaces | Макс. I/O Capacity | Ценовой диапазон |
| BMXP341000 | Шнайдер | 2048 kB | 1 × Modbus + 1 × Ethernet | 512 Цифровой + 128 Analog | $730~$850 |
| 1769-L32E | Роквелл | 1 МБ | 1 × Ethernet + 2 × Serial | 1024 I/O Points | $800~$950 |
| CPU 1214C | Сименс | 50 kB Program + 100 kB Data | 1 × Ethernet + 1 × Serial | 288 I/O Points | $600~$750 |
| CJ2M-CPU13 | Омрон | 2048 kB | 1 × Ethernet + 2 × Serial | 1024 I/O Points | $700~$820 |
- Application Environments & Industry Cases
- Применимые сценарии
Manufacturing Industry: Production line automatic control, упаковочное оборудование, material handling system
Энергия & Utilities: Power distribution control, renewable energy system, water treatment plant
Инфраструктура: Building automation, traffic signal control, environmental monitoring system
Еда & Beverage: Processing production line, filling equipment, quality inspection system
Химическая промышленность: Batch control, mixing system, safety interlock device
Pharmaceutical Industry: GMP-compliant production process control
- Non-recommended Scenarios
High electromagnetic interference environment: No special shielding design, extra protective measures required
Explosion-proof area: Standard version without explosion-proof certification, select dedicated explosion-proof models
Unprotected outdoor environment: IP20 protection level, only for indoor control cabinet installation
Redundant system required: BMXP341000 does not support CPU redundancy, choose high-grade models like BMXP344020
- Типичные случаи применения
Случай 1: Automotive Parts Production Line Control
Приложение: Control multi-process automatic production lines including stamping, welding and assembly
Конфигурация: BMXP341000 + Digital I/O module + Analog I/O module + HMI touch screen
Ценить: Realize coordinated control of each process, raise production efficiency by 25% and reduce manual operation
Случай 2: Intelligent Water Treatment Plant Monitoring System
Приложение: Control water pumps, valves, dosing equipment and monitor water quality parameters
Конфигурация: Connect to SCADA system via Modbus/TCP and connect on-site instruments via Modbus RTU
Ценить: Realize remote monitoring and automatic control, cut energy consumption by 30% and stabilize water quality
- Распространенные неисправности & Troubleshooting Solutions
| Явление неисправности | Возможные причины | Решения |
| CPU module fails to start | 1. Power failure | 1. Check 240VAC power supply and measure backplane voltage |
| 2. Poor backplane connection | 2. Reinsert the module and fasten the clip tightly | |
| 3. Program error | 3. Clear programs and redownload for test | |
| 4. Hardware damage | 4. Replace the module for verification | |
| Communication interruption | 1. Incorrect network settings | 1. Verify IP address and subnet mask settings |
| 2. Damaged communication cables | 2. Test network cables and check serial wiring | |
| 3. Mismatched protocol parameters | 3. Unify baud rate, parity bit and other parameters | |
| 4. Damaged ports | 4. Use spare ports for testing | |
| No response from I/O modules | 1. Backplane bus failure | 1. Inspect backplane connection and replace rack for test |
| 2. Defective I/O modules | 2. Replace faulty I/O modules | |
| 3. Wrong address configuration | 3. Confirm correct module address settings | |
| 4. Insufficient power supply | 4. Check power load and add extra power modules | |
| Abnormal program operation | 1. Program logic error | 1. Monitor programs online to find logic errors |
| 2. Memory overflow | 2. Optimize programs to reduce memory usage | |
| 3. External signal interference | 3. Strengthen shielding and grounding for anti-interference | |
| 4. Outdated firmware version | 4. Upgrade to the latest stable firmware | |
| Abnormal flashing indicators | 1. System failure | 1. Check diagnostic information to locate faults |
| 2. Communication error | 2. Inspect communication lines and configurations | |
| 3. Power fluctuation | 3. Install voltage stabilizer to stabilize power quality | |
| 4. Module overheating | 4. Improve ventilation and lower ambient temperature |
VII. Replaceability Analysis of Core Components
| Компонент | Replaceability | Operation Difficulty | Required Tools | Примечания |
| CPU Mainboard | Низкий | Высокий | N/A (integral replacement) | High replacement cost for core parts, whole module replacement recommended |
| Коммуникационный интерфейс | Низкий | Высокий | Soldering iron, solder wire | Highly integrated with mainboard, operated by professional maintenance staff only |
| Memory Chip | Низкий | Высокий | Hot air gun, solder wire | Professional BGA welding equipment required with high operation risk |
| Силовой модуль | Высокий (Внешний) | Низкий | Отвертка | Replace with matched 240VAC power module after power off |
| Backplane Connector | Середина | Середина | Отвертка, clip tool | Disassemble gently to avoid damaging backplane slots |
| Indicator Light | Середина | Середина | Soldering iron, solder wire | SMD components, operate delicately with anti-static measures |
VIII. Ежедневное обслуживание & Prevention Guidelines
- Установка & Правила подключения
Ensure full insertion and firm clamping of modules to avoid poor contact
Separate communication cables from power cables with spacing ≥30cm to reduce electromagnetic interference
Complete reliable system grounding with grounding resistance below 4Ω
- Regular Maintenance Schedule
| Maintenance Item | Cycle | Operation Content |
| Обновление прошивки | Semi-annually | Check official Schneider website and update to latest stable firmware |
| Dust Removal | Ежеквартальный | Clean dust on module surface and vents with compressed air after power cut |
| Connection Inspection | Ежемесячно | Check module installation and wiring tightness |
| Operation Status Monitoring | Weekly | Check CPU load, memory usage and communication status via programming software |
| Program Backup | After every modification | Back up programs and configurations to prevent data loss |
- Fault Prevention Measures
Keep cabinet internal temperature within 0~60°C and humidity at 5~95% non-condensing range
Equip surge protector and UPS to avoid damage from voltage fluctuation and sudden power cut
Set access passwords to restrict unauthorized access and check communication logs regularly
Adopt dual-computer hot standby or redundant communication configuration for key projects
- Соблюдение требований в области авиаперевозок & Сертификаты
- Соблюдение требований в области авиаперевозок
Нет встроенной литиевой батареи, compliant with IATA dangerous goods regulations, deliverable as general cargo by air
Use original packaging or anti-static packaging to prevent vibration and impact damage during transit
Mark FRAGILE label on package to avoid heavy extrusion
- Certification Documents
| Сертификация | Стандартный | Область применения |
| CE | В 61131-2, В 55032 | European market access |
| UL/cUL | UL 61010-1 | North American safety approval |
| РоХС | 2011/65/Евросоюз | Environmental protection compliance |
| МЭК | МЭК 61131-2 | International industrial standard compliance |
- Рекомендации по выбору & Quick Rules
Quick Selection Rules
- Grade Classification: 1000=Level 1, 2000=Level 2, 3000=Level 3, 4000=Level 4
- Memory Standard: Level1=2MB, Level2=4MB, Level3=8MB, Level4=16MB
- Communication Configuration: Базовая версия: 1×Modbus +1×Ethernet; High-grade version supports CANopen or dual Ethernet
- I/O Expansion: Макс. 512 digital +128 analog points for Level1; I/O capacity doubles with each higher grade
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи



















NH42-63-318x560.png)