Гриб 751104 Реле безопасности - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

 Гриб 751104 Реле безопасности - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

электрический/

Гриб 751104 Реле безопасности

For cross-brand replacement of model 751104, the core differences lie in system integration compatibility, diagnostic functions, wiring methods and price ranges. Siemens is ideal for full Siemens-based systems; Schneider boasts powerful diagnostic functions; Omron features the most compact size; Phoenix Contact offers high cost performance; Weidmüller provides flexible wiring; Eaton delivers superior environmental adaptability; Wieland ...

  • Подробная информация о продукте

For cross-brand replacement of model 751104, the core differences lie in system integration compatibility, diagnostic functions, wiring methods and price ranges. Siemens is ideal for full Siemens-based systems; Schneider boasts powerful diagnostic functions; Omron features the most compact size; Phoenix Contact offers high cost performance; Weidmüller provides flexible wiring; Eaton delivers superior environmental adaptability; Wieland shares identical dimensions with Pilz products.

Гриб 751104 PNOZ s4 Compact Safety Relay

  1. Основная информация & Precise Model Definition

Заказ №.: 751104

Официальная модель: PNOZ s4 C 24VDC

Ряд: PNOZsigma s Compact Safety Relay

Official Manual: 21396-EN-21 (2026 Версия)

Разбивка модели

СегментЗначениеОписание
PNOZCore series code of Pilz safety relaysSafety control products complying with EN ISO 13849-1
сUltra-slim compact designHousing width: only 22.5mm, экономия места в шкафу
4Contact configuration codeСтандартный: 3 Нормально открытый (НЕТ) + 1 Нормально закрытый (Северная Каролина) safety contacts
СTerminal typeCage spring terminals (screwless); old model 750104 adopts screw terminals
24В постоянного токаНоминальное рабочее напряжение24 В постоянного тока, voltage range: 20.4-26.4В (-15%/+10%)
  1. Core Electrical Specifications (Official Authorized Data)
КатегорияСпецификацияПримечания
Power Supply Parameters
Номинальное рабочее напряжение24 В постоянного токаFluctuation range: 20.4~26.4V
Power Consumption Current≤120mANo-load condition
Inrush Current0.2АPulse duration: 15РС
Входные характеристики
Входные каналыDual-channel safety input (S11-S12; S21-S22)Supports single/dual-channel wiring with inter-contact short-circuit detection
Входной ток50mA per channelAt 24VDC
Режим сбросаРуководство / Automatic optionalAutomatic reset enabled by short-circuiting S34-S12
Выходные характеристики
Выходы безопасности3 НЕТ контактов: 13-14, 23-24, 33-34Each group consists of 2 series-connected NO contacts for higher safety
Auxiliary Output1 NC contact: 41-42For fault indication and alarm signal
Rated Contact Current6А (AC-1/DC-1)Resistive load at 240VAC / 24В постоянного тока
Thermal Rated Current4.5АWhen 3 contacts operate simultaneously
Механический & Параметры окружающей среды
Время ответа≤15msKey safety-related index
Housing Width22.5ммStandard DIN rail mounting size
Класс защитыIP20For cabinet internal installation
Рабочая температура-10℃ ~ +55℃Температура хранения: -25℃ ~ +70 ℃
Wiring TypeCage spring clamp terminalWire cross-section: 0.2~2.5mm²
Сертификаты безопасности
Уровень безопасностиВ ИСО 13849-1: PL e, Кат.4Highest safety rating
Functional SafetyМЭК 61508: уровень безопасности SIL3Applicable to safety-critical systems
Международные сертификатыCE, ТЮВ, UL, CSAGlobally approved
  1. Full PNOZ s Series Order Number List (Основные модели)
Номер заказа.МодельНапряжениеКонфигурация контактовТип терминалаОсновные функции
751101PNOZ s1 C24В постоянного тока1НО+1НЗSpring clampSingle-channel input, basic safety control
751102PNOZ s2 C24В постоянного тока3НО+1НЗSpring clampSingle-channel input, no short-circuit detection
751103PNOZ s3 C24В постоянного тока3НО+1НЗSpring clampDual-channel input, manual reset
751104PNOZ s4 C24В постоянного тока3НО+1НЗSpring clampDual-channel input, manual/automatic reset optional (mainstream model)
751105PNOZ s5 C24В постоянного тока4НЕТ (2 instant + 2 delayed)Spring clampDelayed output, for equipment requiring braking delay
751106PNOZ s6 C24В постоянного тока3NO+1NC+1 semiconductor outputSpring clampSolid-state output, suitable for high-speed switching
750104ПНОЗ с424В постоянного тока3НО+1НЗВинтовой терминалObsolete model, replaced by 751104
751204PNOZ s4 C 24VDC24В постоянного тока3НО+1НЗSpring clampHigh-current upgraded version, rated contact current 10A
  1. Замена & Compatibility List

4.1 Old & New Model Replacement

Old ModelЗапасная модельReplacement Description
750104751104Fully compatible; only terminal changed from screw to spring clamp, идентичные функции & параметры
750134751104Replacement for wide voltage version (24-240В переменного/постоянного тока); confirm power supply type first

4.2 Competitor Equivalent Reference (Same-grade Safety Relays)

БрендМодельComparative Advantages
Сименс3TK2825-1BB40Сниженная цена, perfect for Siemens PLC system integration
ШнайдерXPS-AV1110More comprehensive diagnostic functions, fit for complex safety systems
ОмронG9SA-321-T075More compact size, ideal for ultra-narrow installation space
PILZ 751104Высокий уровень безопасности (PL e/SIL3), flexible wiring, complete global certifications
  1. Сценарии применения & Industry Cases

✅ Recommended Application Scenarios

  1. Emergency Stop Circuit: Connect series emergency stop buttons to cut off power of hazardous equipment instantly once triggered
  2. Safety Gate Monitoring: Detect open/closed status of protective gates and halt moving machine parts when gates open
  3. Photoelectric Safety Protection: Connect safety light curtains to stop equipment when personnel enter dangerous zones
  4. Two-hand Control: Applied to punching & bending machines; machine starts only with simultaneous two-hand operation to avoid misoperation
  5. Automated Production Line: Multi-device linkage safety control for zoned emergency stop
  6. Упаковка / Печать / Injection Molding Machinery: Mold protection and safety interlock control

Typical Industry Applications

Автомобильное производство: Safety fence monitoring for welding robots

Electronic Assembly: Safety gate interlock for SMT production lines

Food Processing: Emergency stop circuit for filling machines complying with food machinery safety standards

Machine Tool Equipment: Safety guard control for CNC machine tools

❌ Not Recommended Scenarios

Direct AC220V power supply (convert to 24VDC via transformer)

Outdoor open-air, высокая влажность (>95%относительной влажности) and heavy dust environments (only IP20 protection)

Direct switching of high-power main circuits (max 6A contact current; expand via contactors)

Explosion-proof areas (без сертификата взрывобезопасности)

Underwater installation or high-pressure washing environments

  1. Соблюдение требований в области авиаперевозок & Certification Info

6.1 Air Freight Compliance Confirmation

No built-in batteries or energy storage components: Classified as ordinary industrial electrical goods, non-dangerous goods

Air freight category: General cargo, no special shipping documents or marks required

Sea & land transportation: No restrictions, shipped as standard industrial products

6.2 Main Certifications & Official Numbers

СертификацияCertificate No.Applied Standard
CE0120-CPD-022В 60947-5-1, В ИСО 13849-1
ТЮВ9706037МЭК 61508: уровень безопасности SIL3
ULE175588UL 508, UL 61010-1
CSALR24536CSA C22.2 No. 14
  1. Поиск неисправностей & Рекомендации по техническому обслуживанию

Распространенные неисправности & Решения

Явление неисправностиВозможная причинаInspection StepsРешения
Power LED flashesLow/unstable input voltage1. Measure voltage between terminal A1-A21. Adjust voltage to 20.4-26.4V
2. Check power adapter2. Replace qualified power supply
Fault LED keeps onShort circuit or failure on input channels1. Check wiring of S11-S12 / S21-S221. Eliminate inter-contact short circuit
2. Test after disconnecting loads2. Replace damaged input components
In1/In2 LED flash alternatelyShort circuit between S12 and S221. Check dual-channel wiring1. Correct wrong wiring
2. Power off and restart2. Ensure channel insulation
No output signal1. Input not activated1. Check input status1. Activate input signals
2. Reset circuit open2. Verify S34-S12 reset loop2. Close reset circuit
3. Damaged output contacts3. Measure contact resistance3. Replace the relay
Accidental emergency stop1. Ослабленная проводка1. Tighten all terminals1. Retighten terminals
2. Electromagnetic interference2. Add shielding measures2. Use shielded cables
3. Power fluctuation3. Install filter modules3. Stabilize power quality

График технического обслуживания

Routine inspection: Check LED status and wiring tightness monthly

Periodic maintenance: Clean terminals and inspect contact wear every 6 месяцы

Service life suggestion: Replace every 8~10 years (adjust according to operating frequency)

  1. Мнемоника выбора

24V S4 model with 3NO+1NC spring terminals,

Dual-channel input with dual reset modes,

PL e & SIL3 high safety performance,

22.5mm slim size saves cabinet space,

Standard safety choice for industrial control!

Overview of Cross-brand Replacement for Pilz 751104 PNOZ s4 Compact Safety Relay

For cross-brand replacement of model 751104, the core differences lie in system integration compatibility, diagnostic functions, wiring methods and price ranges. Siemens fits full Siemens automation systems; Schneider has powerful diagnostics; Omron is ultra-compact; Phoenix Contact is cost-effective; Weidmüller supports diverse wiring; Eaton adapts well to harsh environments; Wieland is dimensionally identical to Pilz.

  1. Таблица сравнения основных параметров
БрендМодельНомер заказа.Время ответаШиринаОсновные преимущества
PILZPNOZ s4 C 24VDC751104≤15ms22.5ммComplete global certifications, flexible wiring
СИМЕНС3TK2825-1BB403TK2825-1BB40≤15ms22.5ммStrong system integration, rich diagnosis
ШНАЙДЕРXPSUAF13APXPSUAF13AP≤15ms22.5ммExpandable, powerful diagnostic performance
OMRONG9SA-321-T075G9SA-321-T075≤15ms17.5ммUltra-slim structure
PHOENIXPSR-SPP-24DC/ESD/3X1/1X22904950≤15ms22.5ммВысокая стоимость исполнения, простая установка
WEIDMÜLLERSCS 24VDC P1SIL3DS MG38938670000≤15ms22.5ммHigh protection grade, harsh environment resistant
EATONMSR1270MSR1270≤15ms22.5ммШирокий температурный диапазон, heavy industry oriented
WIELANDSNO 4083-24VSNO 4083-24V≤15ms22.5ммPin-to-pin replacement with Pilz
  1. In-depth Brand Analysis & Рекомендации по замене

2.1 Siemens 3TK2825-1BB40

Основные преимущества

Seamless connection with Siemens S7 series PLC for shared diagnostic data

Supports PROFIBUS / PROFINET communication

Built-in current monitoring for output contact fault diagnosis

Соответствует МЭК 61508 уровень безопасности SIL3 & В ИСО 13849-1 PL e

Советы по применению

✅ Prioritize for full Siemens automated projects to cut integration costs

✅ Perfect for complex safety systems requiring PLC data interaction

❌ Less cost-effective in non-Siemens systems

2.2 Schneider XPSUAF13AP

Основные преимущества

Multi-level fault diagnosis with LED & text fault display

Modular design expandable up to 8 safety outputs

Built-in safety self-test function simplifies on-site commissioning

Compatible with Schneider safety bus system

Советы по применению

✅ Ideal for production lines requiring detailed fault troubleshooting

✅ Best choice for multi-function integrated safety equipment

✅ Matches perfectly with Schneider Modicon PLC

2.3 Omron G9SA-321-T075

Основные преимущества

Ultra-narrow 17.5mm width saves 50% пространство кабинета

Low power consumption ≤80mA, suitable for battery-powered devices

Built-in surge suppression with strong anti-interference capability

Economical for mass installation

Советы по применению

✅ Recommended for space-limited equipment such as small robots

✅ Suitable for large-quantity layout on assembly lines

❌ Not fit for frequent manual wiring operation due to narrow terminal spacing

2.4 Phoenix Contact PSR-SPP-24DC/ESD/3X1/1X2

Основные преимущества

Spring clamp wiring triples installation efficiency

Built-in electronic short-circuit protection extends contact service life

Hot-swap supported for easy on-site maintenance

Obvious price advantage with high cost performance

Советы по применению

✅ Best choice for projects demanding fast installation & простота обслуживания

✅ Matches Phoenix distributed I/O systems perfectly

✅ Cost-saving option for mass-produced standard equipment

2.5 Weidmüller SCS 24VDC P1SIL3DS MG3

Основные преимущества

Standard IP20, partial models reach IP40 protection level

Supports 0.2~4mm² wide-range wire connection

All-round self-diagnosis for power, input and output faults

Excellent vibration resistance for rail transit & тяжелая техника

Советы по применению

✅ Preferred for dusty & vibrating harsh working conditions

✅ Suitable for applications needing large cross-section wiring

✅ Unified wiring layout matched with Weidmüller terminal blocks

2.6 Eaton MSR1270

Основные преимущества

Wide working temperature range: -25℃~+70℃ for extreme environments

10A high rated current can directly drive small motors

Multi safety logic: аварийная остановка, safety gate, двуручное управление

Complete global safety certifications

Советы по применению

✅ Suitable for outdoor and non-air-conditioned workshop equipment

✅ Widely used in heavy industry and new energy industries

✅ Perfect alternative for high-current safety control demands

2.7 Wieland SNO 4083-24V

Основные преимущества

Fully consistent 22.5mm dimension with Pilz PNOZ s series for direct replacement

Identical terminal layout with no cabinet modification needed

Built-in contact welding detection function

15~20% lower price than Pilz original products

Советы по применению

✅ First choice for Pilz system renovation & снижение затрат

✅ Ideal for retrofitting projects retaining original cabinet layout

✅ Preferred alternative in mechanical manufacturing industry

  1. Key Factors for Cross-brand Selection
Selection FactorKey PointsRecommended Brands
Совместимость системыMatching degree with existing PLC & automation platformСименс (S7), Шнайдер (Modicon), Омрон (Sysmac)
Space LimitationAvailable installation space inside cabinetОмрон (17.5мм), Pilz/Siemens/Schneider (22.5мм)
Diagnostic DemandFault diagnosis depthШнайдер (top), Сименс, Вайдмюллер
Wiring EfficiencyOn-site installation & maintenance convenienceФеникс Контакт (spring terminal), Гриб 751104
Ambient ConditionТемпература, влажность, vibration levelИтон (wide temp), Вайдмюллер (anti-vibration)
Cost BudgetOverall project cost controlФеникс Контакт, Wieland, Омрон
Special Safety FunctionsDelay output, extended output etc.Шнайдер (расширяемый), Итон (high current)
  1. Replacement Implementation Rules & Примечания

4.1 Direct Replacement Feasibility

Physical Compatibility: All models except Omron are 22.5mm wide for direct DIN rail mounting

Электрическая совместимость: Uniform 24VDC power supply and 3NO+1NC output for direct wiring replacement

Functional Compatibility: All support dual-channel input and dual reset modes with identical safety standards

4.2 Replacement Precautions

  1. Reset Circuit: Automatic reset wiring definition varies by brand; adjust S34-S12 connection referring to official manuals
  2. Diagnostic Program: Reconfigure PLC diagnosis logic to adapt to new brand fault signal definition
  3. Certification Verification: Confirm alternative models meet all required project certifications (CE, UL, CSA etc.)
  4. Контактная емкость: Ensure rated contact current meets actual load demand (minimum 6A consistent with 751104)

4.3 Optimal Selection Scheme

New projects: Select the same-brand safety relay as your automation control system for better compatibility

Renovation projects: Prioritize Wieland (dimension fully compatible) or Phoenix Contact (easy wiring)

Bulk replacement: Choose cost-effective Omron or Phoenix Contact

  1. Cross-brand Selection Mnemonic

Siemens excels in system integration,

Schneider leads in diagnosis function,

Omron owns the slimmest dimension,

Phoenix wins high cost attribution,

Weidmüller adapts tough condition,

Eaton fits wide temperature application,

Wieland replaces Pilz without variation,

Matching selection brings best operation!

Предыдущий:

Следующий:

Оставить ответ

Оставить сообщение