Schneider LADN20 Auxiliary Contact Block

Модель: LADN20 Brand: Schneider Electric Product Series: Matching accessories for TeSys D / TeSys Deca contactors Product Type: Front snap-on instantaneous auxiliary contact block Contact Configuration: 2НЕТ (2 Normally Open contacts, no Normally Closed contacts) Способ монтажа: Direct snap-fit on contactor front face, tool-free installation Applicable Contactors: LC1D09~LC1D150, CAD control relays, LC1F / CR1F series ...

  • Подробная информация о продукте

Модель: ЛАДН20

Бренд: Шнайдер Электрик

Серия продуктов: Matching accessories for TeSys D / TeSys Deca contactors

Тип продукта: Front snap-on instantaneous auxiliary contact block

Конфигурация контактов: 2НЕТ (2 Normally Open contacts, no Normally Closed contacts)

Способ монтажа: Direct snap-fit on contactor front face, tool-free installation

Applicable Contactors: LC1D09~LC1D150, CAD control relays, LC1F / CR1F series contactors

  1. Разбивка кода модели
  2. LADN: General prefix for front-mounted auxiliary contacts of TeSys D series
  3. 2: Total number of contact circuits = 2
  4. 0: Number of NC (Нормально закрытый) contacts = 0

Full definition: 2 Нормально открытый, 0 Normally Closed auxiliary contacts

Universal naming rule for the same series:

ЛАДН02: 0НЕТ, 2Северная Каролина

LADN11: 1НЕТ, 1Северная Каролина

LADN22: 2НЕТ, 2Северная Каролина

  1. Terminal Markings & Wiring Definition

Two independent NO circuits with standard terminal numbers:

1st NO circuit: 53 (вход), 54 (выход)

2nd NO circuit: 63 (вход), 64 (выход)

Terminal structure: Screw-clamp terminals, момент затяжки 1.7 Н·м

Compatible wire cross-sections:

Single solid wire / ferrule-equipped flexible wire: 1~4 mm²

Two parallel wires: 1~2,5 мм²

  1. Основные электрические характеристики

4.1 Номинальное напряжение изоляции Ui

690 В (стандарт МЭК); UL/CSA certified for 600 В

4.2 Conventional Thermal Current Ith

10 А (ambient temperature 60°C)

4.3 AC-15 AC Control Load (Solenoid Valves / Coils / Indicator Lamps)

120 В и: 6 А

230 В и: 3 А

400 В и: 1.8 А

690 В и: 1.04 А

4.4 DC-13 DC Inductive Load

125 В Вашингтоне: 0.55 А

600 В Вашингтоне: 0.1 А

4.5 Minimum Operating Condition (Suitable for Weak Signals)

Minimum switching voltage: 17 В; Minimum switching current: 5 мА

4.6 Contact Operation Timing

No overlap time between make and break: 1.5 РС (NO and NC contacts never conduct simultaneously)

4.7 Защита & Параметры окружающей среды

Класс защиты: IP20 (for indoor cabinet use only)

Рабочая температура: -25℃ ~ +60 ℃

Механическая жизнь: ≥ 30 миллион операций

Электрическая жизнь (under standard load): ≥ 1 миллион операций

4.8 Размеры & Масса

Размеры: 48 (ЧАС) × 26 (Вт) × 42 (Д) мм; Net weight ≈ 30 г

  1. Сертификаты & Стандарты

Сертификаты: CCC, CE, UL, CSA, ЕАС, UKCA

Соответствующие стандарты: ГБ/Т 14048.5, МЭК 60947-5-1, В 50012

  1. Функции & Сценарии применения
  2. Motor Start-Stop Feedback: Two independent passive NO signals after contactor closure, sent to PLC, indicator lamps and upper computer for operating status collection
  3. Expansion of Electrical Interlocks: Add interlock contacts for dual-motor and forward/reverse control circuits
  4. Multi-channel Alarm Output: One circuit for local panel lamps, one for remote control cabinet signals
  5. Расширение цепи управления: Supplement auxiliary contacts when factory-built contacts are insufficient (LC1D standard configuration only includes 1NO+1NC)

Applicable Industries: Станки, ОВК, водяные насосы, фанаты, automatic production line control cabinets

  1. Selection Table for LADN Front-Mounted Contacts of the Same Series
МодельКонфигурация контактовОсновное приложение
ЛАДН202НЕТDual-channel operation feedback, no NC signal required
ЛАДН022Северная КаролинаFault shutdown and open-circuit status detection
LADN111НО+1НЗOne operation signal + one fault signal (most universal)
LADN222НО+2НЗMulti-signal collection and complex interlock circuits
  1. Установка & Replacement Instructions
  2. Установка: Align with the front slot of the contactor and press down until a snap sound is heard for locking; for removal, pinch both side latches and pull upward
  3. Installation Limit: A single LC1D contactor can be fitted with maximum 1 front LADN contact block. The LAD8N series side-mount modules are required for additional contacts
  4. Альтернативные модели

Domestic equivalents with identical functions: Delixi F4-20, Chint F4-20

Schneider side expansion contacts: LAD8N20 (side-mounted 2NO contacts)

  1. Strict Usage Prohibitions
  2. Not allowed for main power circuits; only applicable to control signals and small coil loads (АС-15 / DC-13)
  3. Forbidden to operate above the rated insulation voltage of 690 В
  4. Cannot be exposed outdoors or in humid unprotected environments (IP20 rating limited to cabinet interior)
  5. Do not connect multiple 4 mm² wires to one single terminal; maximum cross-section for parallel wiring is 2.5 мм²

Full Application Fields of Schneider LADN20 Auxiliary Contact Block

  1. General Industrial Automation
  2. Conveying Line Equipment

Collect contactor status for belt conveyors, роликовые линии, transfer machines and lifting positioning mechanisms. Two NO circuits separately transmit local lamp signals and operation data to PLC.

  1. Custom Non-standard Automation Machines

Expand original contactor contacts on assembly machines, inspection equipment and stamping loading/unloading machines to upload equipment running status remotely.

  1. Robot Supporting Control Cabinets

Monitor solenoid valve circuits for robot external axes and fixture clamping; two isolated passive signals avoid mutual interference.

  1. Machine Tool Processing Industry (Main Application Scenarios)
  2. CNC Lathes, Machining Centers, Milling Machines

Expand contacts for spindle motors, cooling pumps and chip conveyors. One signal feeds local panel running lamps, the other transmits ready signals to the machine tool system.

  1. Grinding Machines & Drill-Tap Centers

Collect start-stop status of lubrication pumps and hydraulic stations to meet the demand for synchronous multi-signal output on machine tools.

  1. Stamping & Sheet Metal Machines

Realize status interlock and signal upload for main hydraulic motors and feeding motors.

  1. ОВК, Water Supply & Drainage, Building Electromechanical Systems
  2. Вентилятор & Water Pump Control Boxes

For air conditioning fans, вентиляторы градирни, circulating pumps and sewage pumps, two NO contacts deliver local indication signals and communication data to building BA systems respectively.

  1. Central Air Conditioning Units

Expand contact terminals for chillers and condensate pumps for remote building monitoring.

  1. Fire-fighting Supporting Equipment

Upload operating status of smoke exhaust fans and sprinkler pumps to fire alarm control panels.

  1. Подъемное оборудование, Логистика & Warehousing Machinery
  2. Overhead Cranes & Electric Hoist Control Cabinets

Collect running signals of lifting, cross-travel and long-travel contactors. Two signal channels serve local display and upper warehouse management systems separately.

  1. Automated Warehouses & Stackers

Transmit status feedback of traveling motors and fork lifting motors for stacker safety interlock judgment.

  1. Энергия, ОВК & Environmental Protection Equipment
  2. Air Compressor & Vacuum Pump Control Cabinets

Monitor main loading motors and cooling fans; upload operation data to energy management systems for runtime statistics.

  1. Sewage Treatment Equipment

Multi-channel status collection for aeration fans, dosing pumps and sludge transfer pumps.

  1. PV Auxiliary Equipment

Output start-stop signals for cooling fans and circulating water pumps.

  1. Rubber & Plastic, Упаковка & Printing Industry
  2. Injection Molding & Extrusion Machines

Transmit operation feedback of screw motors, mold temperature machine water pumps and conveyor belts.

  1. Упаковка & Printing Machines

Two independent signal outputs for film feeding and winding motors to distinguish local alarm and remote monitoring signals.

  1. Железнодорожный транзит & EV Charging Pile Supporting Systems
  2. Status collection for charging pile cooling fans and main contactors
  3. Signal expansion for station ventilation and water pump electromechanical control cabinets
  4. Application Matching Features (Matching LADN20’s 2NO-only characteristic)

Universal requirement across all industries: only collect power-on running status without open-circuit fault signals; two isolated passive switching signals with separate grounding and no voltage conflict.

Select LADN11 (1НО+1НЗ) if both running and shutdown fault signals need to be collected simultaneously.