Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Schneider LUCA32BL TeSys U Standard Control Unit - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

электрический/

Schneider LUCA32BL TeSys U Standard Control Unit

The LUCA32BL is a three-phase motor standard control unit belonging to Schneider Electric‘s TeSys U series. It must be used in combination with LUB series power bases (LUB32/LUB38) to form a complete motor starter, providing comprehensive protection against overload, short circuit, phase loss, ground fault and other faults. Core Product Parameters Parameter Item Specification Value ...

  • Подробная информация о продукте

The LUCA32BL is a three-phase motor standard control unit belonging to Schneider Electric‘s TeSys U series. It must be used in combination with LUB series power bases (LUB32/LUB38) to form a complete motor starter, providing comprehensive protection against overload, short circuit, phase loss, ground fault and other faults.

  1. Core Product Parameters
Параметр ЭлементСпецификация ЗначениеDescription
Product SeriesTeSys USchneider’s new-generation modular motor control and protection system
Control TypeStandard Control Unit (LUCA)Basic motor protection, suitable for normal working conditions
Диапазон номинального тока8-32АAdjustable, compatible with the rated current of motors
Номер полюса3П (Three-phase)Designed for three-phase asynchronous motor control
Control Circuit Voltage24V DCCoil operating voltage, requiring independent external power supply
Номинальное рабочее напряжение690В иMaximum operating voltage of the main circuit
Trip ClassClass 10Overload trip time: примерно 2 seconds at 10脳In
Compatible Power15kW@400V / 18.5kW@600VMaximum power compatibility for three-phase motors
Функции защитыПерегрузка, Short Circuit, Phase Loss, Phase Imbalance, Ground FaultComprehensive motor protection meeting IEC standards
Reset MethodРучной сбросManual recovery is required after a fault to ensure safety
Способ монтажаPlug-in TypeQuick combination with LUB power bases without tools
Степень защитыIP20 (Cabinet-mounted)Prevent accidental contact with live parts by fingers
  1. Detailed Functional Features
  2. Защита от перегрузки: Achieves Class 10 trip characteristics through adjustable current setting (8-32А), compatible with motors of different power ratings.
  3. Short Circuit Protection: Features an instantaneous trip function, which cooperates with LUB power bases to quickly cut off the circuit in case of short circuit faults.
  4. Phase Loss/Phase Imbalance Protection: Monitors three-phase currents in real time, and immediately cuts off the circuit when any phase is missing or the current imbalance degree exceeds the set value.
  5. Ground Fault Protection: Built-in ground fault detection function, with configurable ground fault current threshold to prevent leakage hazards.
  6. Индикация состояния: LED indicators display the running and fault statuses, facilitating quick fault diagnosis.
  7. Модульная конструкция: Can be combined with various accessories (such as communication module LUFN) to expand functions.

III. Companion Products and Compatibility

  1. Mandatory Companion Products
Product ModelProduct NameФункцияCompatibility Description
LUB32Power BaseProvides main circuit contacts and mounting interfaceCompatible with 8-32A control units, rated current 32A
LUB38Power BaseProvides main circuit contacts and mounting interfaceCompatible with 8-32A control units, rated current 38A
LU2B32BLReversing Contactor Circuit BreakerDesigned for reversible motor controlCombined with LUCA32BL to realize forward and reverse rotation control
  1. Optional Expansion Accessories
Accessory ModelAccessory NameФункцияApplication Scenario
ASILUFC5/ASILUFC51Auxiliary Contact ModuleProvides additional normally open/normally closed contactsControl circuit expansion and status feedback
LUFC00Communication Interface ModuleEnables Modbus communicationRemote monitoring and data acquisition
LUFNNetwork Communication ModuleSupports multiple industrial busesIndustrial automation system integration
  1. Типичные сценарии применения
  2. Motor control and protection for general machinery such as water pumps and fans
  3. Motor protection for continuous operation equipment such as compressors and conveyors
  4. Motor control circuits for small and medium-sized production lines
  5. General industrial environments requiring basic protection functions
  6. Safety circuits or automation systems requiring 24V DC control
  7. Installation and Wiring Key Points
  8. Этапы установки
  9. Ensure the power supply is disconnected and confirm that the installation environment meets IP20 requirements.
  10. Align the LUCA32BL control unit with the guide rail of the LUB power base, press vertically downward until aclicksound is heard to confirm it is locked in place.
  11. Connect the control circuit: Connect the 24V DC power supply to the +/- terminals of the control unit.
  12. Connect the main circuit: Connect the three-phase power supply to the incoming terminals of the LUB power base, and connect the outgoing terminals to the motor.
  13. Adjust the current setting: Rotate the current adjustment knob on the control unit to the corresponding value according to the rated current of the motor.
  14. Характеристики проводки
Circuit TypeТребования к проводкеСпецификация провода
Схема управления (24V DC)Requires independent external power supply, positive and negative poles must not be reversed0.5-1.5мм² (AWG 24-16)
Основная схема (≤690V AC)Three-phase power supply L1/L2/L3 connected to incoming terminals, U/V/W connected to the motorSelected according to motor current, recommended ≥2.5mm² (AWG 14)
Auxiliary CircuitAuxiliary contact output for status indication or control0.5-1.5мм² (AWG 24-16)
  1. Troubleshooting Guide
Fault PhenomenonPossible CausesSolutions
Motor fails to startNo 24V DC power supply in the control circuit; stop button not closed; phase lossCheck power supply, buttons and wiring; measure three-phase voltage
Trips immediately after startupExcessively low current setting value; motor locked-rotor; short circuit faultIncrease the current setting; check motor load; locate short circuit points
Overload trip during operationMotor overload; excessively high ambient temperature; poor heat dissipationReduce load; improve ventilation; clean heat sinks
Phase loss protection activatedThree-phase power supply imbalance; loose wiring; blown fuseCheck power supply; tighten wiring; replace fuse
Ground fault tripDamaged motor insulation; broken cable; excessively high ground resistanceCheck motor insulation; replace cable; measure ground resistance

VII. Product Selection and Replacement

  1. Selection Key Points: Select according to the motor’s rated current (8-32А), control voltage (24V DC) and protection requirements (standard type).
  2. Replacement Suggestions: Can directly replace the corresponding models of Schneider’s old TeSys L series (например, LUB32+LUA32), with compatible mounting dimensions.
  3. Upgrade Solution: For advanced diagnostic functions, it can be replaced with LUCD32BL (advanced control unit), which adds fault recording, parameter setting and other functions.

As a standard control unit of Schneider’s TeSys U series, the LUCA32BL is an ideal choice for the control of small and medium-sized three-phase motors due to its modular design, comprehensive protection functions and convenient installation method. Combined with the LUB power base, it can provide a current protection range from 8A to 32A, compatible with three-phase motors below 15kW, and meet the basic control and protection needs in the field of industrial automation.

Предыдущий:

Следующий:

Оставить ответ

Оставить сообщение