Сервопривод Schneider LXM32MD72N4

LXM32: Lexium32 series servo M: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function) D72: Peak output current 72A, continuous 24A N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply Core Electrical Specifications Item Specification Power Supply 3-phase AC 208~480V, 50/60Hz Rated Power 400V class: 7кВт; 230V класс: 5kW Continuous Output Current 24A (8kHz carrier ...

  • Подробная информация о продукте

LXM32: Lexium32 series servo

М: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function)

D72: Peak output current 72A, continuous 24A

N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply

Основные электрические характеристики

ЭлементСпецификация
Источник питания3-phase AC 208~480V, 50/60Гц
Номинальная мощность400V класс: 7кВт; 230V класс: 5кВт
Непрерывный выходной ток24А (8kHz carrier frequency)
Пиковый выходной ток72А, sustainable for 5s
Встроенный фильтр ЭМСStandard integrated
Speed Loop BandwidthUp to 1600Hz, высокий динамический отклик
Несущая частота8кГц
DC Bus Undervoltage Threshold350В (400V класс)

Коммуникация & ввод/вывод

  1. Полевая шина: CANopen (LXM32M model, different from pulse-type LXM32A)
  2. Цифровой: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; цифровые выходы
  3. Интерфейс энкодера: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
  4. Интерфейсы: RJ45 debug port, detachable color-coded terminals for convenient cabinet wiring and maintenance

Matching Motors

Compatible with BSH / BMH 400V class серводвигатели of Lexium32 series. Typical match: 140-flange BSH high-torque motor, continuous torque up to 27.8N·m, peak 90.2N·m, common speed 3000rpm.

Сценарии применения

Упаковочное оборудование, machine tool feed axes, CNC cutting, текстильное оборудование, material handling conveying, multi-axis synchronization equipment; suitable for automated production lines requiring CANopen bus multi-axis linkage and high dynamic positioning.

Установка & Среда

Book-style cabinet mounting, vertical installation on control cabinet DIN rail

Категория перенапряжения: Class III

Max leakage current: 30мА

Recommended wire gauge for power terminals: 3мм², tightening torque 0.5N·m

Вина & Замечания по вводу в эксплуатацию

  1. Общие сигналы тревоги: Overcurrent OC, Overvoltage OV, Undervoltage UV, Ошибка энкодера, Overheat OH
  2. Программное обеспечение для ввода в эксплуатацию: SoMove, supports online parameter configuration, oscilloscope sampling and automatic inertia tuning
  3. For high-power working conditions, it is recommended to install an external 1mH line reactor to reduce harmonics and incoming current surges

Замена & Selection Remarks

Pulse version of the same series: LXM32AD72N4 (no CANopen, pulse-direction control)

Upgrade alternative: Шнайдер Lexium28 series; comparable competitors: Siemens V90, Mitsubishi MR-J4

Примечание: LXM32 is a discontinued legacy series. Lexium28 is preferred for new projects; stock or second-hand units are available only for spare part projects.

Ссылка на код ТН ВЭД

85011099 (сервопривод, re-verify customs classification before customs declaration)

LXM32MD72N4 SoMove Power-on Commissioning Parameter Template

Применимый: Lexium32M 7kW CANopen bus servo, matched with BSH/BMH 400V motors; SoMove software, expert mode password 696969

Pre-operation: Complete hardware wiring including power cable, кодер, аварийная остановка, тормоз, CAN bus and 24V control power supply; perform no-load jog test first, then auto-tune under load; save parameters to EEPROM after modification.

  1. Базовая конфигурация (Simply Start Wizard Page)
Имя параметраParameter IDРекомендуемая настройкаОписание
Control SourceDEVcmdInterfПолевая шинаLXM32M CANopen positioning mode; temporarily change to Terminal for local jog
Motor SelectionMotor SelectionSelect corresponding BSH/BMH modelDrive loads motor nameplate parameters automatically; must not select incorrectly
Тип кодераENC1_typeSinCos / ЭнДатSelect according to motor encoder; EnDat absolute encoder requires battery module
Несущая частотаPWM_Freq8кГцDefault for LXM32MD72N4, not recommended to increase
Направление вращенияInvertDirOfMoveВЫКЛЮЧЕННЫЙ (По умолчанию)Set to ON if rotation direction reversed; power cycle required after change
Auto Enable on Power-upIO_AutoEnable0 (Disabled)Disabled during commissioning; can be set to 2 for mass production after safety assessment
  1. Axis Limit Parameters (Axis Configuration → Limitations)
Имя параметраParameter IDРекомендуемая настройкаОписание
Max Output CurrentCTRL_I_maxНоминальный ток двигателяLimit maximum torque to protect machinery; cannot exceed 72A peak of drive
Max Motor SpeedM_n_maxMotor rated speedTypical 3000rpm for BSH/BMH, do not exceed nameplate
Positive Software LimitPOS_LIM_PUser unitInside mechanical hard limit to prevent overtravel
Negative Software LimitPOS_LIM_NUser unitSame as positive limit
E-Stop DecelerationQS_DecCustomDeceleration triggered by emergency stop, safety related
  1. ввод/вывод & Safety Parameters (Axis Configuration → IO)
Имя параметраParameter IDРекомендуемая настройкаОписание
Positive Limit ContactIOsigLIMPНЗ нормально закрытыйDefault for safety standards; set to NO if using normally open sensors
Negative Limit ContactIOsigLIMNНЗ нормально закрытыйТо же, что и выше
Brake Release DelayBRK_AddT_Release100РСBrake motor: wait for brake release before movement after servo enable
Brake Apply DelayBRK_AddT_Apply50РСDelay brake output after servo disable to prevent axis falling
Сброс неисправностиIO_FaultResetAssign DI terminalExternal reset button
  1. Position Scaling (Scaling, Core for Positioning Projects)

User units per revolution, пример: 10mm per revolution for lead screw, modify as required

| Имя параметра | Parameter ID | Example Value | Описание |

| —| —| —| —|

| Position Numerator | ScalePOSnum | 10 | Numerator of travel per revolution |

| Position Denominator | ScalePOSdenom | 1 | Denominator; пример: 10mm/rev → 10/1 |

| Velocity Scaling | ScaleVELnum / ScaleVELdenom | Follow position | Velocity unit: mm/s |

| Acceleration Scaling | ScaleACCnum / ScaleACCdenom | Follow position | Acceleration unit: mm/s² |

Raw encoder resolution: 16384count/rev for SinCos motors

  1. Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)

Prioritize SoMove automatic inertia identification + auto-tune, then fine tune

| Имя параметра | Parameter ID | Initial Recommendation | Tuning Logic |

| —| —| —| —|

| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |

| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |

| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |

| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |

| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |

| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |

  1. CANopen Fieldbus Parameters (Key for LXM32M)
Имя параметраParameter IDРекомендуемая настройкаОписание
CAN Node IDCAN_NodeID1~127No duplicate for multi-axis, consistent with PLC
CAN Baud RateCAN_Baud500кбит/сCommon setting; use 250kbps for long distance, terminal resistor ON at both bus ends
PDO MappingPDO ConfigurationStandard positioning PDOTarget position, слово статуса, actual position, fault code
Fieldbus Control ModeProfile ModeProfile PositionPositioning control; select Profile Velocity for speed axis
Profile Acc/DecPRO_ACC / PRO_DECMechanical dependentЕдиница: user unit/s
Quick Stop RampPRO_QSDecIndependent E-stop decelerationDeceleration upon bus failure
  1. Homing Parameters
Имя параметраParameter IDОписание
Homing ModeHOM_mode0~35 optional; общий: limit homing, index homing, direct origin setting for absolute encoder
Homing VelocityHOM_VelНизкая скорость, 50~200 user unit/s
Homing Search VelocityHOM_Vel_SearchSlightly higher than homing speed
Homing OffsetHOM_OffsetMechanical origin offset
  1. Мониторинг & Fault Log

Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults

осциллограф: Sample target position, actual position, following error, bus voltage, motor current for resonance and tuning analysis

Save: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file

Complete Power-on Commissioning Procedure (Matching Parameter Template)

  1. Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
  2. Run Simply Start wizard, select motor model and confirm encoder type
  3. Configure limit, brake and I/O terminal definition
  4. Set position scaling and mechanical transmission ratio
  5. Set CANopen Node ID, baud rate and configure PDO
  6. No-load test: Давать возможность, бегать трусцой, verify rotation direction, limit and brake logic
  7. On-load test: Run Auto-tune inertia identification to generate base gains
  8. Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
  9. Homing test, point positioning test, acceleration/deceleration test
  10. Save parameters to EEPROM and export .cxm backup file

Commissioning Precautions

  1. Expert mode password 696969, enter expert mode to modify advanced parameters
  2. Auto-tune must be performed with actual load; parameters tuned under no-load easily oscillate under load
  3. Incorrect brake timing will directly cause axis falling; test brake function without load during first commissioning
  4. CANopen шина: Enable terminal resistor only at the first and last device on bus, отключить для промежуточных узлов
  5. For high-power LXM32MD72N4, check wiring of line reactor and braking resistor before first power-up

Optional Extended Parameters

Тормозной резистор: BRK_R, BRK_P for external braking resistor resistance/power rating, bus overvoltage protection

Аналоговый вход: AI scaling for analog speed mode (not commonly used for CANopen projects)

Schneider Lexium32 (LXM32) Full Series Drive Model List

3 main branches: LXM32C (Basic Analog) / LXM32A (Пульс + Модбус) / LXM32M (CANopen bus type, LXM32MD72N4 belongs to this branch)

Suffix explanation:

М2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC

Dxx: Number after D = peak current (А), continuous current = 1/3 of peak current

Статус: Full series discontinued, only available on spare parts market

  1. LXM32M (CANopen Bus Type, High Priority, includes LXM32MD72N4)

Single-phase 200~240V (Suffix M2)

МодельПиковый токНепрерывный ток230V Rated Power
LXM32MD12M212А4А0.75кВт
LXM32MD18M218А6А1.0кВт
LXM32MD30M230А10А1.6кВт
LXM32MD42M242А14А2.5кВт
LXM32MD57M257А19А3.5кВт

3-phase 208~480V (Suffix N4, your series)

МодельПиковый токНепрерывный ток400V Rated Power
LXM32MD12N412А4А0.9кВт
LXM32MD18N418А6А1.8кВт
LXM32MD30N430А10А3кВт
LXM32MD42N442А14А4.5кВт
LXM32MD57N457А19А5.5кВт
LXM32MD72N472А24А7кВт
LXM32MD85N485А32А9кВт
  1. LXM32A (Pulse/Direction + Модбус, no CANopen, та же номинальная мощность)

Single-phase M2

LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2

3-phase N4

LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4

  1. LXM32C (±10V analog basic model, speed/current control only, no positioning)

Single-phase M2

LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2

3-phase N4

LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4

  1. Matching Motor Series (BSH / BMH for Lexium32)
  2. BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
  3. BMH Motors: EnDat absolute encoder, многооборотный, IP65; flange sizes 55/70/100/140/190mm
  4. Список аксессуаров (General for LXM32)

VW3M8101: Тормозной резистор

VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)

VW3M8102: Line reactor

VW3M8200: Pre-made I/O terminal cable

VW3M8300: CANopen bus cable

VW3M8400: Motor power cable

VW3M8500: Encoder cable

Branch Comparison Overview

Модельная серияИнтерфейс управленияФункция позиционированияПолевая шинаТипичное применение
LXM32C±10V Analog❌ No positioningМодбусPure speed control
LXM32AПульс+Направление✅ Point positioningМодбусPulse PLC control
LXM32MCANopen✅ Electronic gear / Точка / HomingCANopenMulti-axis bus synchronization (LXM32MD72N4)

Советы по выбору:

  1. Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
  2. LXM32MD85N4 is the largest model in this series, 9кВт
  3. New project replacement: Lexium28 series; only stock/second-hand units available for spare part projects.