Schneider RXM2AB2P7 Relay

The RXM2AB2P7 is a plug-in miniature intermediate relay belonging to Schneider Harmony Zelio series, featuring 2 переключающие контакты (2CO/DPDT), 12A rating, 230Катушка переменного тока В, built-in LED indicator and lockable test button. It matches RXZE series sockets, widely applied in industrial automatic control, PLC interface connection, motor control and building automation. It is certified with CE/UL/CSA/RoHS ...

  • Подробная информация о продукте

The RXM2AB2P7 is a plug-in miniature intermediate relay belonging to Schneider Harmony Zelio series, featuring 2 переключающие контакты (2CO/DPDT), 12A rating, 230Катушка переменного тока В, built-in LED indicator and lockable test button. It matches RXZE series sockets, widely applied in industrial automatic control, PLC interface connection, motor control and building automation. It is certified with CE/UL/CSA/RoHS and compliant with air freight regulations (no built-in lithium battery).

  1. Model Code Definition
РазделКодЗначение
Код серииRXMZelio series plug-in miniature intermediate relay
Contact Quantity22 sets of changeover contacts (2CO/DPDT), а именно 2 нормально открытый + 2 нормально закрытый
Functional FeatureABEquipped with lockable test button + mechanical indicator window + detachable label
LED Status2With coil LED indicator (1 = without LED)
Напряжение катушкиP7230В переменного тока 50/60 Гц

Full Model Definition: Schneider Zelio RXM series plug-in miniature intermediate relay with 2 sets of 12A changeover contacts, блокируемая кнопка тестирования, mechanical indicator window, LED indicator and 230V AC coil voltage.

  1. Основные технические параметры
Категория параметраСпецификацияПримечания
Основные характеристики
Конфигурация контактов2СО (DPDT / 2НО+2НЗ)Double-pole double-throw, AgNi silver-nickel contact material
Номинальный рабочий ток (Т.е.)12A @ 250V AC (МЭК), 10A @ 300V AC (UL/CSA)резистивная нагрузка
Номинальное напряжение изоляции (Уи)250В (МЭК), 300В (UL/CSA)Withstand voltage level
Номинальное импульсное выдерживаемое напряжение (Умп)4кВ (1.2/50мкс)Surge protection capability
Coil Specifications
Напряжение катушки230В переменного тока 50/60 ГцDefined by code P7
Потребляемая мощность катушкиПриблизительно. 1020mWOperating power
Подобрать / Drop-out Time≤20 мс / ≤20 мсResponse speed
Электрическая выносливость10⁶ operations (номинальная нагрузка)Durability index
Механическая выносливость10⁷ operationsNo-load operation times
Физический & Environmental Data
Измерение (Ш×В×Г)22.5×57×44mmStandard DIN rail size
Тип монтажаТип плагина, compatible with RXZE series socketsSocket sold separately
Класс защитыIP40Dustproof protection
Рабочая температура-40°C ~ +55°CWide temperature adaptability
Температура хранения-40°С ~ +70°СТранспорт & storage temperature
Vibration / Ударная устойчивость10~55 Гц, 0.5мм двойной амплитуды / 100м/с²Industrial environment adaptability
  1. Full Series Model List (RXM AB Series)
МодельContact NumberContact CurrentВЕЛНапряжение катушкиПримечания
RXM2AB2P72СО12АДа230В иStandard model
RXM2AB2B72СО12АДа24В иCommon control voltage
RXM2AB2E72СО12АДа48В и
RXM2AB2F72СО12АДа120В и
RXM2AB2BD2СО12АДа24В Вашингтоневерсия постоянного тока
RXM2AB2FD2СО12АДа110В Вашингтоне
RXM2AB2UD2СО12АДа220В Вашингтоне
RXM4AB2P74СО10АДа230В и4-contact version
RXM3AB2P73СО10АДа230В и3-contact version
RXM2AB1P72СО12АНет230В иNon-LED version

Мнемоника выбора: Numbers stand for contact groups; AB/LB/CB define functions; 1/2 means with/without LED; P7/B7/E7/BD represent voltages; 12A/10A indicate contact current.

  1. Cross-brand Comparison & Сменные модели

4.1 Internal Schneider Replacement

Оригинальная модельЗапасная модельReplacement Description
RXN21P7RXM2AB2P7 + RXZE1M2C socketRXN series discontinued, replaced by RXM series
RXM2AB2P7RXM2AB2P7PVSVersion with surge suppression
RXM2AB2P7RXM2CB2P7Without detachable label (same function)

4.2 Competitor Equivalent Models

БрендМодельEquivalent SpecificationРазница
Сименс3RT2016-1BB422СО, 12А, 230В иDifferent mounting size, более высокая цена
АББCR-M024DC22СО, 12А, 24В ВашингтонеТип постоянного тока, faster response
ОмронMY2N-GS2СО, 12А, 230В иСниженная цена, shorter service life
ВайдмюллерDRM570230LT2СО, 12А, 230В иWith test button, DIN rail mount
  1. Application Environment & Industry Cases

5.1 Применимые сценарии

ПромышленностьТипичное применениеПреимущества
Промышленная автоматизацияPLC output expansion, signal amplificationLockable test button for easy troubleshooting
Управление двигателемПуск звезда-треугольник, reversible control, soft starter triggering12A contact capacity fits contactor coil control
Автоматизация зданийHVAC system, управление освещением, пожарная связьWide working temperature (-40°C~55°C), Защита IP40
Энергетическая системаSecondary circuit of switchgear, protection relay actuation4kV impulse withstand, strong anti-surge performance
Packaging MachineryConveyor control, cylinder solenoid valve driveFast response ≤20ms, long mechanical service life 10⁷ times

5.2 Non-recommended Applications

Direct control of high inductive loads (surge suppressor recommended)

Continuous load current over 12A (choose RXM4 series or contactors)

Severe oil mist and heavy dust environments (limited IP40 protection)

Strong electromagnetic interference environments (shielding measures suggested)

5.3 Типичные случаи применения

Случай 1: PLC-controlled motor forward/reverse circuit

Конфигурация: 2 sets of RXM2AB2P7 + RXZE1M2C sockets

Функция: Control forward/reverse contactor coils via PLC outputs to realize motor reversible operation

Преимущество: Quick fault judgment via lockable test button; mechanical window shows contact status intuitively

Случай 2: Zoned building lighting control

Конфигурация: 8 sets of RXM2AB2P7 + RXZE1M2C sockets

Функция: Independent on-off control of 8 lighting zones through building automation system

Преимущество: LED indicators facilitate inspection; IP40 protection adapts to electrical shaft environment

  1. Соблюдение требований в области авиаперевозок & Сертификаты

6.1 Air Freight Compliance Judgment

Compliance ItemResultBasis
Built-in Lithium BatteryНиктоElectromagnetic relay without battery components
Magnetic SubstanceNon-dangerous goodsWeak coil magnetic field, compliant with IATA DGR 2.3.2.2
Shipping CategoryGeneral cargoNo UN number, shipped as regular electronic products
Packaging RequirementAnti-static bag + carton boxPrevent pin damage and static electricity

6.2 Certification List (Including Certificate No.)

СертификацияStandard No.Certificate Information
CEВ 61810-1, В 61810-3Comply with LVD 2006/95/EC & EMC 2014/30/EU directives
ULUL 508, UL 1059Сертификат №.: E82889
CSAC22.2 No.14Сертификат №.: LR64742
РоХС2011/65/ЕвросоюзMeet RoHS 2.0 hazardous substance restrictions
REACH(EC) Нет 1907/2006Free of SVHC high-concern substances
ЕАСTR CU 004/2011Customs Union certification for Russia, Kazakhstan etc.
  1. Распространенные неисправности & Руководство по устранению неполадок

7.1 Fault Quick Check Table

Явление неисправностиВозможные причиныTroubleshooting StepsРешения
Coil no power (LED off)1. Power disconnected / wrong voltage1. Measure coil terminal voltage1. Correct power connection
2. Burnt coil2. Test coil resistance (normal: приблизительно. 5кОм)2. Заменить реле
3. Poor socket contact3. Re-plug relay3. Clean socket contacts
Contacts fail to act1. Locked test button1. Unlock red test button1. Unlock button
2. Механические помехи2. Press test button manually2. Заменить реле
3. Контактная сварка3. Check contact continuity after power off3. Replace contacts or relay
Контактное прилипание1. Перегрузка / короткое замыкание1. Check load current1. Derate usage or add contactor
2. Excessive surge current2. Test surge peak value2. Install surge suppressor
3. Contact wear3. Inspect contact ablation3. Заменить реле
LED on but contacts not switching1. Too low coil voltage1. Ensure voltage ≥85% rated value1. Raise control voltage
2. Mechanical failure2. Check mechanical indicator window2. Заменить реле
3. Контактное окисление3. Очистите контакты3. Очистите или замените контакты

7.2 Рекомендации по техническому обслуживанию

  1. Регулярный осмотр: Check LED status, mechanical window and test button function every 6 месяцы
  2. Contact Life Management: Replace in advance when operation times approach 10⁶ cycles
  3. Environment Control: Avoid ambient temperature over 55°C or humidity over 95%; clean dust regularly
  4. Защита от перенапряжения: Install RC snubber or varistor for all inductive load circuits
  5. Информация для заказа & Выбор аксессуаров

8.1 Order Codes

Main Product: RXM2AB2P7 (relay body only, socket excluded)

Recommended Socket: RXZE1M2C (screw terminal, fits 2CO relays)

Surge Suppressor Module: RXZS1 (RC snubber for inductive loads)

8.2 Список аксессуаров

Название аксессуараМодельФункция
Screw Terminal SocketRXZE1M2CStandard mounting for 2CO relays
Spring Terminal SocketRXZE1M2PFast wiring, tool-free connection
Marker StripRXZE1LDetachable contact function marking
Ограничитель перенапряженияRXZS1Protect contacts and extend service life
Fixing ClipRXZE1CAnti-vibration, enhance mounting stability
  1. Selection Avoidance Tips
  2. Согласование напряжения: Ensure coil voltage matches control circuit; never mix AC and DC (P7=230V AC, BD=24V DC)
  3. Контактная емкость: ≤12A for resistive loads, ≤6A for inductive loads (50% derating recommended)
  4. Socket Matching: Only use RXZE series sockets; do not mix other brands
  5. Test Button Note: Unlock the lockable button after use to avoid wrong fault judgment
  6. LED Indication Rule: 2 = with LED, 1 = without LED, select according to on-site demand

Краткое содержание: RXM2AB2P7 is a stable and fully-functional miniature intermediate relay suitable for most industrial control occasions. Focus on contact quantity, coil voltage and load type during selection. Equipped with matched sockets and accessories, it greatly improves system reliability and maintenance convenience.