Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Schneider SR2A201FU Compact Smart Relay - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

электрический/

Schneider SR2A201FU Compact Smart Relay

ЭлементParameter
Тип продуктаCompact Smart Relay
SeriesZelio Logic SR2
I/O Configuration12 discrete inputs + 8 relay outputs (20 I/O points in total)
Power Supply Voltage100~240V AC, 50/60Гц
Display FunctionEquipped with LCD screen and navigation buttons
Clock FunctionNo built-in real-time clock
Способ монтажа35mm standard DIN rail mounting
Класс защитыIP20 (front panel), IP40 (overall)
Рабочая температура-20℃ ~ +55℃
Storage Temperature-40℃ ~ +70 ℃
Гарантийный срок18 months

  • Подробная информация о продукте

Complete Technical Guide for Schneider SR2A201FU Compact Smart Relay

The Schneider SR2A201FU is a compact smart relay belonging to the Zelio Logic series. It integrates basic PLC functions with the advantages of relay control, and is suitable for logic control, remote management and monitoring of simple automation systems. The following is the complete technical parameters, functional features, application scenarios and model selection & replacement solutions.

  1. Core Product Overview
ЭлементParameter
Тип продуктаCompact Smart Relay
SeriesZelio Logic SR2
I/O Configuration12 discrete inputs + 8 relay outputs (20 I/O points in total)
Power Supply Voltage100~240V AC, 50/60Гц
Display FunctionEquipped with LCD screen and navigation buttons
Clock FunctionNo built-in real-time clock
Способ монтажа35mm standard DIN rail mounting
Класс защитыIP20 (front panel), IP40 (overall)
Рабочая температура-20℃ ~ +55℃
Storage Temperature-40℃ ~ +70 ℃
Гарантийный срок18 months
  1. Detailed Technical Parameters

(я) Input Characteristics

ParameterСпецификация
Number of Input Points12 discrete input points
Input TypeDC 24V (стандартный), compatible with NPN/PNP signals
Input CurrentApproximately 7mA per point
Response Time≤10ms
Isolation MethodPhotoelectric isolation, 2500В и

(II) Output Characteristics

ParameterСпецификация
Number of Output Points8 relay output points
Contact TypeНормально открытый (НЕТ), C-type contacts (необязательный)
Номинальный токMaximum 8A per point, for AC-1 category loads
Номинальное напряжениеMaximum 250V AC / 30V DC
Механический срок службы≥10 million operations
Electrical Service Life≥100,000 operations (at rated load)
Surge ProtectionBuilt-in RC snubber circuit

(III) Control Functions

ФункцияСпецификация
Programming MethodLadder Diagram, supports 0~240 logic lines
Built-in Function Blocks16 timers, 16 counters, shift registers, comparators, и т. д..
MemoryBuilt-in EEPROM flash memory, data retention up to 10 годы
Communication InterfaceSupports USB/Bluetooth communication expansion via SR2USB01 or SR2BTC01 module
Program CapacityCan store multiple programs, supports program copying to other SR2 relays

III. Core Functional Features

  1. Integrated Design: Integrates PLC logic control and relay output, meeting small-to-medium-sized control requirements without additional expansion modules.
  2. Easy Programming: Supports ladder diagram programming. On-site editing, monitoring and fault diagnosis can be performed via the built-in LCD screen and navigation buttons, eliminating the need for a dedicated programmer.
  3. Flexible Adaptability: Wide voltage power supply (100~240V AC) is compatible with power grids worldwide, and DC 24V input is compatible with industrial sensor signals.
  4. Reliable and Durable: Industrial-grade design with strong anti-electromagnetic interference capability, suitable for harsh industrial environments.
  5. Data Security: Built-in EEPROM memory ensures no program or data loss after power failure, with a backup cycle of up to 10 годы.
  6. Cost Optimization: Replaces traditional relay control cabinets, reduces wiring complexity, and lowers maintenance costs and potential fault points.
  7. Типичные сценарии применения
  8. Управление двигателем: Start-stop, forward-reverse rotation, star-delta reduced-voltage starting and other self-locking and interlocking control for single/three-phase motors.
  9. Pump and Valve Systems: Logic control and protection for water supply and drainage, hydraulic and pneumatic systems.
  10. HVAC Control: Interlocking control of temperature/pressure/flow for fans, compressors and air conditioning systems.
  11. Lighting Management: Timed lighting, zoning control and energy-saving management for industrial plants and commercial buildings.
  12. Equipment Interlocking: Sequence control, counting, time delay and interlocking protection for simple processes in production lines.
  13. Remote Monitoring: Realize remote monitoring and control of equipment operating status through communication modules.
  14. Programming and Commissioning Methods
  15. On-site Programming: Directly perform logic editing, parameter setting and fault diagnosis via the built-in LCD screen and navigation buttons.
  16. Software Programming: Use the Zelio Soft dedicated programming software (including Discovery Package learning version), which supports ladder diagram editing, simulation and program upload/download.
  17. Communication Expansion:

SR2USB01: USB communication module, enabling high-speed data transmission between PC and relay.

SR2BTC01: Bluetooth communication module, supporting wireless programming and monitoring.

  1. Fault Diagnosis: The LCD screen displays real-time I/O status, timer/counter values and fault codes, facilitating quick problem location.
  2. Model Selection, Replacement and Cross-brand Alternatives

(я) Schneider Same-series Alternatives

МодельDifferencesСценарии применения
SR2A101FUNo LCD screenCost-sensitive fixed control scenarios that do not require on-site programming
SR2A201FWWith real-time clockApplications requiring timing control and time recording
SR2B201FU8 inputs + 4 relay outputsScenarios with fewer I/O point requirements
SR2B201FW8 inputs + 4 relay outputs + clockSimple timing control scenarios

(II) Cross-brand Alternative Solutions

BrandМодельСовместимостьПримечания
ЧинтNX-SR Series Smart Relays★★★☆☆Similar functions, I/O points need to be matched accordingly
ВкусныйCDSR Series★★★☆☆Compatible with basic logic control functions
OmronCP1E Series Micro PLC★★★★☆More abundant functions, programming software needs to be adapted
СименсLOGO! Series★★★★☆Same type of compact smart relay with different communication protocols

VII. Installation and Wiring Key Points

  1. Installation Location: Mount on 35mm standard DIN rail, reserve ≥50mm heat dissipation space, and avoid high temperature, humidity, dust and strong electromagnetic interference environments.
  2. Power Supply Wiring: Connect L/N to 100~240V AC power supply, and ensure the PE terminal is reliably grounded.
  3. Input Wiring:

Connect the common terminal (КОМ) to the negative pole of DC 24V.

Connect input points to the positive pole of sensor signals, with a response time ≤10ms.

  1. Output Wiring:

The common terminal (КОМ) of relay outputs can be connected to AC 220V or DC 24V power supply.

Maximum load of 8A per point; for inductive loads, a freewheeling diode (округ Колумбия) or RC snubber circuit (переменного тока) must be connected in parallel.

  1. Communication Wiring: Realize USB/Bluetooth communication through expansion modules, with communication cable length ≤5m.

VIII. Common Fault Troubleshooting

Fault PhenomenonPossible CausesTroubleshooting Methods
Power indicator not litPoor power connection/abnormal voltage/damaged power moduleCheck power wiring and voltage, replace the power module
No input responseAbnormal input signal/wiring error/damaged input pointMeasure input signal, check wiring, replace the input point
No output actionDamaged output point/load short circuit/logic errorCheck load and wiring, simulate and test logic with Zelio Soft
Program lossEEPROM fault/abnormal power failureCheck power stability, re-download the program
Communication failurePoor connection of communication module/incorrect software settingsCheck module connection, confirm communication parameter matching
  1. Safety and Maintenance Suggestions
  2. Безопасная эксплуатация: Programming and wiring must be performed under power-off conditions to avoid electric shock risks.
  3. Регулярное техническое обслуживание:

Inspect wiring terminals for looseness and clean dust on the equipment surface every quarter.

Test I/O point response and relay contact reliability every year.

  1. Program Backup: Regularly back up programs via Zelio Soft software to prevent data loss.
  2. Spare Parts Reserve: It is recommended to reserve spare relays of the same model for critical applications to shorten fault downtime.

Предыдущий:

Следующий:

Оставить ответ

Оставить сообщение