Пояснение кода модели (XB2-BVM4LC)
| Модельный сегмент | Определение |
| XB2 | Harmony XB2 Series – 22mm Standard Pushbutton & Pilot Light Range |
| Б | Integrated complete pilot light (head and base as one unit, no assembly required) |
| В | Pilot Light |
| М | LED light source, AC 220~230V 50/60Hz AC version |
| 4 | Light head color: Красный |
| ЛК | Factory version complying with Chinese standards, plastic threaded mounting base |
Supplementary color codes for the same series:
1 = White, 3 = Green, 4 = Red, 5 = Yellow, 6 = Blue
Suffixes for voltage differentiation:
М: 220 В переменного тока
вопрос: 380 В переменного тока
Б: 24 В переменного/постоянного тока
Д: DC direct current
- Основные технические характеристики
2.1 Электрические параметры
Номинальное напряжение: AC 220~230V, 50/60Гц
Allowable Voltage Fluctuation: 0.8~1.1×Us (176V~253V)
Рабочий ток: Приблизительно. 20мА
Источник света: High-brightness monochromatic LED, filament-free, длительный срок службы
Категория перенапряжения: Класс I
2.2 Mechanical Mounting Dimensions
Вырез в панели: Standard Φ22.5mm
Способ монтажа: Secured via rotating plastic lock nut; compatible with control cabinet panels of 1~6mm thickness
Head Appearance: Round convex lens cover
2.3 Защита & Экологические характеристики
Защита от проникновения: IP66 (front dustproof and waterproof); IK05 impact resistance
Рабочая температура: -25℃ ~ +55 ℃
Температура хранения: -40℃ ~ +70 ℃
Применимая высота: ≤2000м, no power derating required
Стандарты соответствия: IEC60947-5-1, GB/T14048.5, CE, РоХС, ДОСТИГАТЬ
2.4 Service Life Metrics
LED Electrical Service Life: ≥50,000 hours of continuous illumination
Устойчивость к вибрации: 15г (40~2000Гц)
- Структура & Инструкции по подключению
3.1 Определение терминала
The base is equipped with only 2 wiring terminals X1 and X2, non-polarized for AC supply
Х1: Live wire L
Х2: Neutral wire N
AC circuits have no polarity; connecting the two terminals to any position of a 220V circuit will light up the red pilot light.
3.2 Процедуры монтажа
- Drill a Φ22.5mm round hole on the control cabinet panel, insert the pilot light body from the front side of the panel;
- Fit the lock nut onto the rear side and tighten manually for fixation;
- Connect control wires to terminals X1 and X2 on the base, then fasten wire clamping screws;
- Switch on power to test steady illumination.
- Сценарии применения
- Standard application for red lights: Equipment fault alarm, emergency stop circuit indication, overload warning, shutdown alert;
- Compatible equipment: PLC control cabinets, воздушные компрессоры, станки, production lines, water pump & fan control boxes;
- Тип цепи: Mains AC 220V control circuit, no intermediate transformer required.
- Cross-Series Selection Reference Table
| Модель | Цвет | Номинальное напряжение | Сценарий применения |
| XB2-BVM1LC | Белый | 220 В переменного тока | Standby, power-on indication |
| XB2-BVM3LC | Зеленый | 220 В переменного тока | Normal equipment running status |
| XB2-BVM4LC | Красный | 220 В переменного тока | Вина, shutdown, тревога |
| XB2-BVM5LC | Желтый | 220 В переменного тока | Ready state, pre-alert warning |
| XB2-BVM6LC | Синий | 220 В переменного тока | Manual/Auto mode differentiation |
24V low-voltage alternative model: XB2-BVB4LC (Красный, 24В переменного/постоянного тока)
- Матрица устранения неполадок
| Явление неисправности | Первопричина | Решение |
| No illumination after power-on | 1. No 220V supply in circuit; 2. Loose wire terminals; 3. Burnt LED chip | Measure circuit voltage with multimeter; retighten wiring terminals; replace the complete pilot light assembly |
| Flickering light with unstable brightness | Voltage exceeds 0.8~1.1 times rated value, poor wire contact | Stabilize supply voltage; re-crimp connecting wires |
| Severe overheating of pilot light | Long-term overvoltage operation, утечка в цепи | Verify input voltage; inspect circuit insulation integrity |
| Internal short circuit caused by water ingress into panel | Loose lock nut, oversized panel cutout damaging IP66 performance | Tighten lock nut fully, seal gaps on panel cutout |
- Safe Operation Specifications
- Strictly prohibit direct connection to 380V supply, which will burn out the LED instantly; select XB2-BVQ4LC for 380V circuits;
- Recommended wire: 0.75~1.5mm² solid copper wire;
- Install cabinet sealing gaskets for humid control cabinets and outdoor enclosures to maintain IP66 protection;
- Designed solely for status indication, unable to carry high-power loads; no contact output function;
- Do not strike or grind the lens cover; scratches will drastically reduce light transmittance and protection performance.
- Order & Packaging Information
Individually packed per unit; standard packaging: 5 pieces per small box, 100 штук в коробке
Запчасти: No separate LED chip spares available; replace the complete pilot light assembly if damaged
Conclusion on Color Replacement for Шнайдер XB2-BVM4LC (XB2BVM4LC)
- Official Factory Conclusion: The lens cover and LED color cannot be replaced separately
- The XB2-BVM series adopts an integrated non-detachable sealed structure (lens cover, colored LED chip, 220V current-limiting circuit and base housing are integrally injection-molded).
- Schneider official FAQ clearly states: The internal LED module of integrated XB2 pilot lights cannot be disassembled separately, and colored lens covers or LED components are not sold as separate spare parts. Only illuminated pushbuttons with split bases support LED core replacement; this all-in-one light does not allow color component replacement.
- Illumination principle: The lens cover itself is transparent, with a built-in red LED chip (color is not generated via colored filter lenses). Even if the lens cover is forcibly unscrewed, the internal light source remains red and color modification is impossible.
- Two On-Site Color Modification Solutions
Решение 1: Direct Full Unit Replacement (Рекомендуется, Compliant, Factory Standard)
Purchase complete units of target color with the same AC 220V voltage; no wiring modification required, compatible with standard panel cutouts:
Белый: XB2-BVM1LC
Зеленый: XB2-BVM3LC
Желтый: XB2-BVM5LC
Синий: XB2-BVM6LC
Этапы замены: Cut off power → Loosen rear lock nut on panel → Remove old red light → Install new colored pilot light → Tighten lock nut and restore wiring.
Решение 2: Temporary Emergency Fix (Only for short-term maintenance, not recommended for long-term equipment operation)
- External colored film: Attach high-temperature resistant translucent colored film to lens surface. Drawbacks: Reduced light transmittance, accelerated aging due to heat, degraded IP protection rating;
- Translucent colored spray coating inside lens cover: Permanently destroys factory IP66 protection rating; water vapor ingress easily triggers short circuits and fails equipment acceptance standards.
- Distinction Between Two Easily Confused Products (To Avoid Wrong Selection)
- XB2-BVM Integrated Pilot Light (Эта модель): Non-replaceable color, integrated encapsulation, no separate LED core spares;
- XB4 Series Pilot Light / XB2 Split Illuminated Pushbutton: Modular design with separately replaceable LED heads for free color switching, suitable for cabinets requiring frequent color adjustments.
- Дополнительные примечания
- Mandatory voltage matching: The original XB2-BVM4LC is rated AC 220V; only models with suffix M (220В) are acceptable for replacement. Models with suffix B (24В) or Q (380В) cannot be used;
- Safety standards compliance: Red/Green/Yellow pilot lights on industrial equipment correspond to fault/Running/pre-alarm status. Unauthorized long-term color modification via film violates machine tool and power distribution safety standards and will fail acceptance inspection;
- Spare Parts Procurement: No separate lens or LED spares; only complete pilot light assemblies can be ordered as replacements.
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи