SIRAI L323V01G-Mini Solenoid Valve Body

Basic Model Definition Brand: SIRAI (now owned by ASCO Emerson, original Italian manufacturer) Модель: L323V01G Function: 3/2 Direct-Acting Normally Closed (Северная Каролина) Mini Solenoid Valve Body (Coil Not Included; ZA/ZB Series Coils to Be Ordered Separately) Core Technical Specifications Fluid Structure Parameters Parameter Item Specification Circuit Configuration 3-Way 2-Position, Нормально закрытый (Северная Каролина) Actuation Type Direct-acting (Нет ...

  • Подробная информация о продукте

Basic Model Definition

Бренд: SIRAI (now owned by ASCO Emerson, original Italian manufacturer)

Модель: L323V01G

Функция: 3/2 Direct-Acting Normally Closed (Северная Каролина) Mini Solenoid Valve Body (Coil Not Included; ZA/ZB Series Coils to Be Ordered Separately)

  1. Основные технические характеристики

Fluid Structure Parameters

Параметр ЭлементСпецификация
Circuit Configuration3-Way 2-Position, Нормально закрытый (Северная Каролина)
Actuation TypeDirect-acting (No pilot; reliable actuation at low pressure)
Port ThreadG1/4 Female Thread (ISO228/1)
Orifice Diameter1.5 мм
Flow Coefficient Kv0.08 м³/ч
Материал корпуса клапанаOT58 Brass
Standard SealNBR Nitrile Rubber (FKM Fluoroelastomer / EPDM Optional)
Max Medium Viscosity37 cSt (5°E)

Pressure Range

Max Static Pressure Rating: 40 бар

Operating Pressure Differential for AC Coils: 0 ~ 16 бар

Operating Pressure Differential for DC Coils: 0 ~ 10 бар

Температурный диапазон

Medium Temperature: -10℃ ~ +90 ℃

Температура окружающей среды: -10℃ ~ +50 ℃ (Max 60℃ for Class F Coils; Max 80℃ for Class H Coils)

Электрическое согласование (Coil Not Included with Valve Body)

Compatible Coil Models: ZA10A, ZB10A, ZA13A, ZB14A, и т. д..

Standard Voltages:

переменного тока: 24В/50 Гц, 110В, 220/230V 50Hz

округ Колумбия: 12В, 24В

Защита от проникновения: IP67 when fitted with standard DIN connector; 100% ЭД (Continuous energization without coil burnout)

  1. 3/2-Way Operating Principle
  2. De-energized (Normal Closed State): Inlet Port 1 is sealed; Порт 2 communicates with exhaust Port 3 for pressure relief.
  3. Energized (Open State): Solenoid pulls plunger; flow path 1→2 opens, exhaust Port 3 is closed.

Приложения: Pneumatic direction switching, vacuum gripping, small air circuit shutoff, water spray control.

  1. Compatible Media & Industrial Applications
  2. Applicable Media: Compressed air, nitrogen, clean water, diluted coolant, non-corrosive inert gas.

NBR is incompatible with oil and high-temperature steam; select FKM seal version for corrosive media.

  1. Типичные применения

Mini pneumatic directional valves for automation equipment

Water circuit control for small washers and humidifying spray systems

Small air circuit shutoff for packaging machines & текстильное оборудование

Laboratory instruments & miniature vacuum circuit control

  1. Выбор модели & Matching Guidelines
  2. Complete Order Model Format: L323V01G-ZA10A 230VAC (Valve Body + Катушка + Номинальное напряжение)
  3. Seal Upgrade: Custom valve bodies with FKM fluoroelastomer seals available for high-temperature / oil-water working conditions.
  4. Альтернативные модели: Same series L323V02G (Нормально открытый НЕТ), L323V03G Universal Type
  5. Требования к монтажу: Mountable at any angle. Install a 40–100 mesh filter upstream of piping to prevent plunger jamming by contaminants. Only wrap the last two rear threads of male pipe threads with PTFE tape to avoid debris entering the valve chamber.
  6. Общая матрица устранения неполадок
Явление неисправностиПервопричинаКорректирующие действия
No switching when energizedСгоревшая катушка, mismatched voltage, pressure differential exceeds 10 bar for DCReplace matching coil; reduce pipeline pressure differential
Persistent leakage after shutdownContaminants on plunger, aged sealsDisassemble and clean plunger; replace NBR/FKM seal kit
Coil heats up rapidlyIncorrect voltage selection, long-term excessive pressure differential, damaged coil insulationVerify nameplate voltage; adopt Class H high-temperature coil
Continuous air leakage from exhaust portWorn plunger, seal scratched by particulate mediaInstall upstream filter; replace complete valve body assembly

ASCO SIRAI L323V01G Solenoid Valve Instruction Manual

Полное название продукта: SIRAI L323V01G 3/2 Direct-Acting Normally Closed Mini Solenoid Valve Body (Coil Not Included)

Brand Affiliation: SIRAI Italy, a fluid control brand under Emerson ASCO

Применимые стандарты: CE, UL, РоХС, DIN43650 electrical connector, ISO228/1 pipe thread

Table of Contents

  1. Обзор продукта & Интерпретация модели
  2. Основные технические характеристики
  3. Valve Body Structure & Fluid Circuit Principle
  4. Материал & Seal Selection
  5. Matching Coil Models & Электрические характеристики
  6. Габаритные размеры & Способы монтажа
  7. Piping Installation Specifications
  8. Electrical Wiring Instructions
  9. Media Compatibility & Сценарии применения
  10. Процедуры технического обслуживания
  11. Fault Diagnosis & Remedies
  12. Complete Order Model Rules
  13. Safety Prohibitions
  14. Обзор продукта & Интерпретация модели

1.1 Product Introduction

The L323V01G is a 3-Way 2-Position Normally Closed (Северная Каролина) direct-acting solenoid valve body. Pilot-free design enables reliable startup under low pressure. Compact size adapts to miniature pneumatic, water and vacuum control loops. Valve body and coils are supplied separately; ZA/ZB series coils must be ordered independently.

1.2 Model Breakdown – L323V01G

СегментОпределение
L323L323 series miniature direct-acting solenoid valve platform
ВBrass valve body version (OT58 Brass)
13/2 Нормально закрытый (Северная Каролина)
ГG1/4 BSPP Female Thread (ISO228/1)

Suffix Comparison for Same Series:

02 = 3/2 Нормально открытый (НЕТ)

03 = 3/2 Универсальный тип

Thread Suffix F = G1/8

  1. Основные технические характеристики

2.1 Fluid Performance

Параметр ЭлементStandard Specification
Functional Type3-Way 2-Position, Нормально закрытый (Северная Каролина)
Размер портаG1/4 Female Thread
Seat Orifice Diameter1.5 мм
Flow Coefficient Kv0.08 м³/ч
Max Medium Viscosity37 cSt (5°E)
Max Static Pressure Rating40 бар
Max Operating Differential Pressure (Катушка переменного тока)0 ~ 16 бар
Max Operating Differential Pressure (Катушка постоянного тока)0 ~ 10 бар

2.2 Температурный диапазон

Medium Temperature: -10℃ ~ +90 ℃ (NBR Seal); -10℃ ~ 120℃ (FKM Fluoroelastomer Seal)

Температура окружающей среды: -10℃ ~ +50℃ for standard Class F coils; max 80℃ for Class H high-temperature coils

2.3 Защита & Сертификаты

IP67 dustproof and waterproof with standard DIN connector

CE EMC compliance, UL coil certification, RoHS lead-free environmental standard

Coils support 100% ED continuous energization without overheating burnout risk

  1. Valve Body Structure & Fluid Circuit Principle

3.1 Valve Port Number Definition (3-Way)

Порт 1 (П): Media Inlet (Air/Water Supply)

Порт 2 (А): Actuator Outlet (Cylinders, Spray Nozzles, Vacuum Suction Cups)

Порт 3 (Р): Exhaust / Drain Port

3.2 Operating States

  1. De-energized Normal State (NC Closed)

Spring resets the plunger to seal Port 1; Порт 2 connects to Port 3 for pressure relief at the actuator end.

  1. Coil Energized Open State

Solenoid magnetic force overcomes spring tension to pull the plunger; flow path 1→2 opens for media output, and Port 3 exhaust passage is sealed.

  1. Материал & Seal Selection

4.1 Base Materials

Valve Body: OT58 Brass

Plunger & Moving Armature: Нержавеющая сталь

Spring: 304 Нержавеющая сталь

4.2 Seal Material Selection Table

Seal GradeМатериалApplicable MediaMax Temperature
Standard Factory FitNBR Nitrile RubberCompressed air, clean water, diluted coolant90℃
Optional UpgradeFKM FluoroelastomerEngine oil, diesel, high-temperature water, weakly corrosive solvents120℃
Special CustomEPDM Ethylene Propylene RubberHot water, ozone, weak acid water110℃
  1. Matching Coil Models & Электрические характеристики

Coils are not included with valve bodies. Complete valve assembly requires matching ZA/ZB series coils; standard models: ZA10A, ZB10A, ZA13A, ZB14A.

5.1 Standard Voltage List

AC Alternating Current: 24V 50Hz, 110V 50Hz, 230V 50Hz

DC Direct Current: 12В Вашингтоне, 24В Вашингтоне

5.2 Coil Electrical Characteristics

Класс изоляции: Optional Class F (155℃) / Class H (180℃)

Разъем: DIN43650 3-pin standard plug (2 power pins + earth pin)

Потребляемая мощность: Приблизительно. 8ВА для переменного тока; Приблизительно. 6Вт для постоянного тока

  1. Габаритные размеры & Способы монтажа
  2. Монтаж & Fixing: Two M3 through mounting holes at valve bottom; mountable at any orientation (horizontal, vertical, inverted without position restrictions).
  3. Key Overall Dimensions (мм):

Total valve length: 45.5, Ширина: 28, Высота: 21; Thread depth: 9.9

  1. Coil Assembly: Vertically snap coil onto positioning posts on valve top; secure via rotary latch, no tools required for assembly/disassembly.
  2. Piping Installation Specifications
  3. Install upstream filter: 40–100 mesh precision screen to prevent seal scratching by particulate contaminants.
  4. Thread Sealing: Only wrap the last two rear threads of male pipe fittings with PTFE tape; forbid debris entering valve chamber.
  5. Контроль крутящего момента: Tightening torque for G1/4 fittings: 8–10N·m to avoid thread slipping or brass body cracking.
  6. Media Flow Direction: Strictly follow marking 1(П)→2(А) on valve body; reverse pressurization prohibited.
  7. Maintenance Clearance: Reserve minimum 30mm clearance on coil side for disassembly.
  8. Electrical Wiring Instructions

8.1 Pre-Wiring Safety Requirements

Perform wiring with power disconnected; confirm zero circuit voltage before plug insertion/removal.

Voltage fluctuation limited within ±10% of rated voltage.

8.2 Определение терминала (3-Pin DIN Connector)

Приколоть 1: Линия электропередачи Л / DC Positive (+)

Приколоть 2: Нейтральная линия N / DC Negative (-)

Приколоть 3: Защитная Земля (Yellow-Green cable; reliable equipment grounding required)

8.3 AC vs DC Distinction

  1. AC Coils: Non-polarized; Pin1/Pin2 can connect live and neutral interchangeably.
  2. DC Coils: Pin1 connects positive, Pin2 connects negative. Reverse polarity will not damage coil but prevents valve switching.

8.4 Waterproof Treatment

Rubber sealing gasket built into plug; tighten lock nut fully after wiring to maintain IP67 rating. Select LED-indicator waterproof plugs for humid outdoor environments.

  1. Media Compatibility & Сценарии применения

9.1 Permitted Media

Dry compressed air, nitrogen, clean water, diluted cutting fluid, vacuum negative pressure circuits

9.2 Prohibited Media

Concentrated acid & alkali, strong organic solvents, high-viscosity oil, particle-laden wastewater, steam (custom high-temperature FKM version required for steam service)

9.3 Typical Industrial Applications

  1. Mini cylinder direction switching for automation equipment
  2. Adhesive spraying & water mist humidification control for packaging machinery
  3. Small air circuit shutoff for textile machines
  4. Laboratory instruments & miniature medical fluid circuits
  5. Vacuum gripping & water switch control for small cleaning equipment
  6. Процедуры технического обслуживания

10.1 Routine Monthly Inspection

  1. Check coils for abnormal overheating or abnormal noise
  2. Inspect pipe threads for media leakage
  3. Verify no continuous air/water dripping from exhaust port

10.2 Periodic Disassembly & Очистка (Каждый 3000 Operating Hours)

  1. Shut off air/water supply, release residual pressure and cut power supply.
  2. Remove coil, disassemble plunger assembly at valve bottom.
  3. Rinse contaminants from plunger and valve seat with purified water and anhydrous alcohol.
  4. Inspect seals for aging or cracking; replace full seal kit if damaged.
  5. Reassemble in original sequence and perform air/water leakage test.

10.3 Spare Parts List

Seal kit, complete plunger assembly, matching coils, DIN waterproof connectors

  1. Fault Diagnosis & Remedy Matrix
Явление неисправностиПервопричинаStandard Remedial Solution
Valve fails to switch on energization1. Сгоревшая катушка; 2. Mismatched voltage; 3. Differential pressure over 10 bar for DCИзмерьте сопротивление катушки, replace compatible coil; reduce pipeline differential pressure
Persistent leakage at Port 2 after power-offContaminant adhesion on plunger, scratched worn NBR sealsDisassemble and clean plunger; replace full seal set
Continuous air leakage at exhaust Port 3Damaged seat seal, sealing surface worn by particulate mediaInstall upstream filter; replace complete valve body assembly
Coil overheats rapidlyExcessive supply voltage, long-term over differential pressure, aged coil insulationMatch supply voltage to nameplate; replace Class H high-temperature coil
Threaded fitting leakageInsufficient PTFE tape wrapping, insufficient fitting torqueRewrap sealing tape and fasten to specified torque
  1. Complete Order Model Rules

Standard Full Model Format:

L323V01G-ZA10A 24VDC

Breakdown: Valve Body Model + Coil Model + Номинальное напряжение

Примеры:

L323V01G-ZB10A 230VAC (Complete valve with 220V AC coil)

L323V01G-ZA13A 24VDC (Complete valve with 24V DC coil)

Seal Upgrade Marking for Orders: Append suffix -FKM, например. L323V01G-FKM-ZA10A 24VDC

  1. Safety Operating Prohibitions
  2. Static pressure exceeding 40 bar strictly forbidden; overpressure will rupture brass valve body directly.
  3. DC circuit differential pressure cannot exceed 10 bar for long-term operation, otherwise full shutoff cannot be achieved.
  4. Operation without upstream filter prohibited; contaminants will permanently damage seals.
  5. Hot plug/unplug of coil connector forbidden; electric arcs may burn coil terminals.
  6. FKM seal version mandatory when medium temperature exceeds 90℃; NBR seals degrade rapidly and fail.
  7. Reverse media installation (inlet via Port2, outlet via Port1) prohibited; permanent internal leakage will occur.
  8. Do not cover coil surface with thermal insulation cotton or debris; sufficient heat dissipation space must be reserved.