Schneider LV429413 - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Schneider LV429413

(MN Type 125VDC Undervoltage Release)

Schneider LV429413 is an MN series undervoltage release specially designed for molded case circuit breakers of the Compact NSX, PowerPact Multistandard, and EasyPact CVS series. It has a rated voltage of 125VDC and uses screwless spring terminals. It is used for emergency stop or remote tripping control. When the control voltage drops below 35% номинальной стоимости, it automatically trips the circuit breaker to ensure system safety.

  1. Интерпретация кода модели
Сегмент кодаЗначение
LVPrefix for Schneider low-voltage power distribution products
4294Product category identifier for undervoltage releases
13Specific specification code corresponding to 125VDC rating, MN type, screwless terminals
MNProduct type code: Расцепитель пониженного напряжения; MX denotes Shunt Trip

Основные функции: 125VDC operating voltage, suitable for 100-630A molded case circuit breakers, non-delay type, tripping threshold at 35% of rated voltage.

  1. Основные технические параметры
ЭлементСпецификация
Тип продуктаMN Type Undervoltage Release
Rated Control Voltage125В постоянного тока (not for AC systems)
Tripping Threshold≤ 35% of rated voltage (приблизительно. 43.75В постоянного тока)
Reset Voltage≥ 85% of rated voltage (приблизительно. 106.25В постоянного тока)
Тип терминалаScrewless Spring Terminal
Compatible Breaker SeriesCompact NSX 100–630A, PowerPact Multistandard, EasyPact CVS
Mounting LocationAccessory slot on front of circuit breaker
Wire Capacity1.5–2.5mm² cable
Защита от проникновенияIP20 (when installed)
Рабочая температура-25°С ~ +70°С
МассаПриблизительно. 50г
СертификатыМЭК 60947-2, UL 489, CSA C22.2 No. 5
  1. Application Environment
  2. System Types

Industrial automation control systems, data center UPS systems

DC power supply systems, emergency stop circuits

Remote monitoring and tripping applications

  1. Условия эксплуатации

Control voltage fluctuation: 85%-110% of rated value for stable operation

EMC performance: Соответствует МЭК 61000-4

Compatible frame sizes: 100А, 160А, 250А, 400А, 630А (NSX series)

  1. Требования к установке

Must be installed in dedicated front accessory slot with reliable mechanical interlock

Control circuit to be protected by 1A fuse to prevent coil damage from short circuit

Observe polarity: “+” for positive, “-” for negative

  1. Cross-Reference & Сменные модели
Replacement TypeМодельБрендОписание
Direct ReplacementLV429414Шнайдер220VAC version for AC control circuits
Equivalent FunctionS29413Шнайдер (Квадрат Д)125VDC undervoltage release for PowerPact series
Cross鈥態rand AlternativeABB TA250-125DCАББ125VDC undervoltage release for Tmax MCCBs
Domestic AlternativeCHINT NXB-MN/125DCЧИНТFor NXB series MCCBs
  1. Official Ordering Information
ЭлементПодробности
Official ModelLV429413 (global part number)
Название продуктаUndervoltage Release MN, Compact NSX, 125В постоянного тока, Screwless Terminal
Order NoteMust match corresponding breaker model, например, NSX100N, НСХ250Ф
PackingIndividual package including release body, руководство, mounting screws
EAN Code3606480019029
минимальный заказ1 piece
  1. Engineering Implementation
  2. Проверка совместимости

Confirm breaker model: only for Compact NSX (100-630А), PowerPact Multistandard, EasyPact CVS

Verify control voltage: strictly 125VDC, not for AC or other DC voltages

Ensure front slot available for MN/MX accessories

  1. Этапы установки
  2. Disconnect main and control power to the breaker
  3. Remove front accessory cover
  4. Insert undervoltage release into slot and engage mechanical interlock
  5. Secure with supplied screws
  6. Wire 125VDC with correct polarity
  7. Refit cover and perform functional test
  8. Commissioning

Тест поездки: reduce voltage below 43VDC; breaker must trip automatically

Reset test: restore voltage above 106VDC; breaker should close normally

Interlock check: breaker cannot be manually closed when release is activated until voltage recovers

  1. Complete Model List (MN Series Undervoltage Releases)
МодельНоминальное напряжениеТип терминалаCompatible SeriesПримечания
LV42940024В переменного/постоянного токаScrew TerminalNSX/CVSСтандартный
LV42940148В переменного/постоянного токаScrew TerminalNSX/CVSСтандартный
LV429402110В переменного/постоянного токаScrew TerminalNSX/CVSСтандартный
LV429403220В переменного/постоянного токаScrew TerminalNSX/CVSСтандартный
LV42941024В постоянного токаScrewless TerminalNSX/CVSSpring Terminal
LV42941148В постоянного токаScrewless TerminalNSX/CVSSpring Terminal
LV429412110В постоянного токаScrewless TerminalNSX/CVSSpring Terminal
LV429413125В постоянного токаScrewless TerminalNSX/CVSSpring Terminal
LV429414220ВАКScrewless TerminalNSX/CVSSpring Terminal
LV429415230ВАКScrewless TerminalNSX/CVSSpring Terminal
  1. Risks & Warnings
  2. Согласование напряжения: This model is only for 125VDC control circuits. Applying AC or incorrect DC voltage will burn the coil and damage the unit.
  3. Polarity: DC polarity must be observed; reversed connection causes failure or circuit damage.
  4. Защита от перегрузки по току: Install 1A fast-acting fuse in control circuit to protect coil.
  5. Механическая блокировка: Ensure reliable engagement; в противном случае, false tripping or failure to trip may occur.
  6. Ambient Limits: Do not use above +70°C or below -25°C to avoid performance degradation.
  7. Обслуживание: Regularly check control voltage stability (85%-110% of rated) to prevent excessive mechanical wear from frequent undervoltage tripping.