CM-DPV1.3.0 is a PROFIBUS-DPV1 communication module designed by LUST (later acquired by Lenze) specifically for C-line series drives. Below are the complete technical specifications and functional features.

  1. ข้อมูลพื้นฐาน

แบบอย่าง: CM-DPV1.3.0 (also marked as CM-DPV1,3.0)

Product Type: PROFIBUS-DP Slave Communication Module (supports DPV1 extension protocol)

Applicable Drives: CDA3000 Inverter, CDD3000 Servo Controller, CDE/CDB3000 Position Controller, CTC3000 Direct Drive Controller

Software Version: Commonly V2.25-00 (upgradable via DriveTop)

รุ่นทดแทน: CM-DPV1.3.1 (hardware compatible, software optimized)

Lenze Replacement: EMF2177IB (fully functionally compatible)

  1. ข้อมูลจำเพาะทางไฟฟ้า
รายการข้อมูลจำเพาะ
Supply Voltage18–30 V DC (powered by drive backplane)
สูงสุด. Operating Current0.25 ก
อินเตอร์เฟซการสื่อสารPROFIBUS-DP (9‑pin D‑sub, compliant with EN 50170)
Baud Rate9.6 กิโลบิตต่อวินาที / 19.2 กิโลบิตต่อวินาที / 45.45 กิโลบิตต่อวินาที / 93.75 กิโลบิตต่อวินาที / 187.5 กิโลบิตต่อวินาที / 500 กิโลบิตต่อวินาที / 1.5 เมกะบิตต่อวินาที / 3 เมกะบิตต่อวินาที / 6 เมกะบิตต่อวินาที / 12 เมกะบิตต่อวินาที (auto‑detection)
Slave Address Range1–125 (set by DIP switches S1/S2 or parameter 582‑PBADR)
Process Data (PZD)Input: max. 244 bytes; Output: max. 244 bytes
Acyclic Data (PKW/DPV1)Supports parameter read/write, diagnostics, firmware upload
ระดับการป้องกันIP20 (installed inside the drive)
อุณหภูมิในการทำงาน0–55 °C
Storage Temperature-25–+70 °C
ขนาดApprox. 90 × 90 × 30 มม (for C-line communication slot)
น้ำหนักApprox. 0.16 กก
  1. Functions and Protocol Features
  2. DPV1 Protocol Support

Cyclic data exchange (PZD): real-time control word, setpoint, status word, actual value

Acyclic data exchange (PKW): parameter read/write, diagnostics, firmware update

Extended diagnostics: detailed network/module/drive status, fault codes

  1. Data Structure

EasyDrive Mode: standard PZD structure (control word / status word + setpoint / actual value)

ProfiDrive Mode: compliant with PROFIdrive profile, suitable for standard PLC configuration

  1. Diagnostic Functions

Bus status, module status, communication errors, drive faults

Supports PROFIBUS standard diagnostic messages and extended diagnostics

  1. Configuration Methods

ฮาร์ดแวร์: address setting via DIP switches, X13 interface coding

Software: parameter configuration via LUST DriveTop / Lenze Engineer, GSD file configuration

GSD File: LUST08E9.GSD (standard version)

  1. Installation and Compatibility

สถานที่ติดตั้ง: Dedicated communication slot for C-line drives (no extra wiring needed)

ความเข้ากันได้: Hardware compatible with CM-DPV1.3.1, direct replacement

Configuration Tools: DriveTop (LUST), Engineer (Lenze)

Supported Systems: Mainstream PROFIBUS masters such as Siemens, ชไนเดอร์, เอบีบี

  1. การใช้งานทั่วไป

Automated production lines, robot systems, เครื่องจักรบรรจุภัณฑ์, printing equipment, material handling

Industrial automation systems requiring PROFIBUS-DP centralized control, parameterization and diagnostics