Application ScenarioPriority Recommended ModelReplacement NotesCore Advantage Selection
Harsh environments (dust/humidity/low air pressure)Chint NJX-13FWSealed protection, zero-arc explosion-proofOxidation-free & zero-arc + IP6K8 protection
การควบคุม PLC (standard load)Schneider RXM2AB2P7Slightly higher coil power consumption, faster responseGood brand compatibility, sufficient spare parts
Omron LY2-DC24
Frequent switching (high life requirement)Omron LY2-DC24Electrical life of 1×10⁶ operations (higher than NJX-13FW)Long-life design, stable and reliable
Schneider RXM2AB2P7
Compact installation (space-constrained)Chint NJX-13FWDimensions of 27.5×21.5×35.5mm (smallest)Small size, light weight
Flange mounting requirementChint NJX-13FWOnly model supporting top/side flange mountingFlexible installation, suitable for special cabinets
Cost-sensitive projectsChint NJX-13FWPrice is about 60%-70% of imported brandsHigh cost performance, performance meets industrial standards

  • รายละเอียดสินค้า

Contact Configuration: Four types available: 2ซี, 2ZS, 3ZS, 4ZS

Key Features: Adopts the patented technology of oxidation-free, arc-free explosion-proof current breaking, featuring oxidation resistance, zero arc discharge, and long service life. Encapsulated in a sealed transparent casing, it provides waterproof, dustproof, and corrosion-resistant performance, suitable for harsh environments such as low air pressure. Complete AC/DC voltage specifications, multiple mounting methods, various matching sockets available, and versions with indicator lights are offered.

Normal Operating Conditions: Temperature range: -25°C ~ +55°C; Relative humidity: up to 95% at +25°C; Atmospheric pressure: 86kPa ~ 106kPa; Mounting position: Any orientation

Main Parameters:

Contact Parameters: Contact material: Silver alloy. 2Z contact load: 10A/220VAC or 28VDC; 2ZS/3ZS contact load: 5A/220VAC or 28VDC; 4ZS contact load: 3A/220VAC or 28VDC. Maximum switching voltage: 250VAC/125VDC. Maximum switching power: 2200VA/280W for 2Z; 1100VA/140W for 2ZS/3ZS; 660VA/84W for 4ZS. Electrical life: 3×10⁵ operations; Mechanical life: 1×10⁷ operations.

Performance & Characteristic Parameters: Insulation resistance: 100 (500VDC). Dielectric withstand voltage: 1500VAC between open contacts; 500VAC between coil-yoke and between different contact groups. Operation time & Release time: ≤25ms each.

Coil Parameters: Rated power consumption: 0.9W (ดี.ซี), 1.8VA (เครื่องปรับอากาศ). Pick-up voltage: ≤75% rated voltage (ดี.ซี), ≤80% rated voltage (เครื่องปรับอากาศ). Drop-out voltage: ≥10% rated voltage (ดี.ซี), ≥20% rated voltage (เครื่องปรับอากาศ). Maximum allowable voltage: 110% rated voltage.

ขนาด: 27.5×21.5×35.5mm

Chint NJX-13FW is an oxidation-free & arc-free electromagnetic relay. Relying on its core technologies and protective features, it is widely used in industrial automation, power systems, communication equipment, rail transit, marine and offshore engineering, harsh environment control, building ไฟฟ้า & security systems, and medical devices, especially suitable for severe working conditions such as low air pressure, ความชื้นสูง, and heavy dust.

  1. Corresponding Relationship between Core Features and Applicable Scenarios
Core Featuresสถานการณ์ที่เกี่ยวข้อง
Oxidation-free & arc-free technologyExplosion-proof requirements, arc-sensitive circuits, precision electronic equipment control
Sealed transparent casing encapsulationWaterproof (IP6K8), dustproof, corrosion-resistant; suitable for outdoor/industrial harsh environments
Long service life designFrequent switching automation production lines, continuous operation equipment
Multiple contact configurations (2Z/2ZS/3ZS/4ZS)Multi-circuit control, signal switching, complex logic circuits
Complete AC/DC specificationsCompatible with different power supply systems, high versatility
Multiple mounting methodsFront-panel top/side flange, PCB soldering, plug-in type; suitable for various control cabinets and equipment
  1. Detailed Application Field Analysis
  2. ระบบอัตโนมัติทางอุตสาหกรรม & Control

PLC Control Systems: Used as PLC output interfaces to realize low-signal control of high-power loads (motors, solenoid valves, heaters, ฯลฯ), compatible with 2Z (10ก), 2ZS/3ZS (5ก), 4ZS (3ก) for different power requirements

Production Line Automation: Applied to logic control and signal interlocking of conveyor lines, packaging machines, printing machinery, improving equipment reliability and service life

Process Control: Serves as an actuator in closed-loop control systems for temperature, pressure, flow rate, ฯลฯ, ensuring control accuracy and stability

  1. ระบบไฟฟ้า & Energy Management

Power Distribution Protection: Acts as an actuator in overload, แรงดันตก, overcurrent protection circuits to monitor and control circuit on/off status

Generator & Transformer Control: Used for start/stop control, excitation regulation, temperature protection, compatible with maximum switching voltage of 250VAC/125VDC

Photovoltaic & Wind Power Systems: Performs signal switching and protection in combiner boxes and inverters, withstanding outdoor environments and voltage fluctuations

  1. Communication & Electronic Equipment

Communication Base Stations: Applied to power distribution, signal routing, and equipment protection; sealed design resists dust and moisture in outdoor/base station room environments

Data Centers: Used for server cluster power management and UPS system switching control; zero-arc feature ensures data security

Broadcasting & TV Equipment: Performs signal switching and power control of transmitters and OB vans, ensuring stable signal transmission

  1. Rail Transit Systems

Train Control Circuits: Logic control of door systems, lighting systems, air conditioning regulation, and braking systems, adapting to vibration and environmental changes during train operation

Signal Systems: Control of railway signal lights, switch points, and platform screen door systems; zero-arc technology improves signal reliability

Vehicle Auxiliary Equipment: Battery management and charging system control, withstanding voltage fluctuations in vehicle electrical systems

  1. Marine & Offshore Engineering

Marine Electrical Systems: Remote control of main engines, auxiliary engine control, power management of navigation equipment; sealed design resists high salt spray and humidity in marine environments

Offshore Platform Equipment: Control circuits of drilling platforms and offshore wind power equipment, adapting to low air pressure and harsh weather conditions

Marine Automation: Engine room monitoring and alarm systems (MSA), liquid level control, fire protection systems; long service life reduces maintenance frequency

  1. Special Control for Harsh Environments

Mining Equipment: Control of underground ventilation, drainage, and transportation systems, withstanding low air pressure and dusty environments

Chemical & Metallurgical Industry: Pump and valve control, temperature monitoring in corrosive environments; corrosion-resistant features extend service life

Outdoor Intelligent Equipment: Street light control, environmental monitoring stations, meteorological equipment; IP6K8 protection grade ensures stable operation

  1. Building Electrical & Security Systems

Building Automation: Control of central air conditioning, ventilation systems, water supply and drainage pumps; compatible with multiple contact configurations to meet different load requirements

Fire Alarm Linkage: Control of fire alarm systems, smoke exhaust fans, fire pumps; zero-arc feature enhances safety

Security Monitoring: Power management of access control systems and video surveillance equipment, ensuring 24-hour stable operation

  1. Medical & Laboratory Equipment

Medical Instruments: Power switching and control of monitors, analyzers, disinfection equipment; oxidation-free feature ensures circuit purity

Laboratory Equipment: Control of precision testing instruments and environmental simulation chambers, adapting to high-precision control requirements in laboratories

III. Typical Application Examples

Application ScenarioRecommended Contact ConfigurationRecommended Mounting MethodCore Advantages
PLC-controlled motor start/stop2ซี (10ก)Plug-in type + CZTO8A-E socketZero-arc protection for PLC, long service life suitable for frequent start/stop
Communication base station power distribution3ZS (5ก)PCB typeSealed protection, multi-circuit control, stable signal
Marine engine room liquid level control2ZS (5ก)Side flange typeCorrosion and moisture resistance, adapting to marine vibration environment
Mining ventilation system control4ZS (3ก)Top flange type + arc shieldLow air pressure resistance, multi-circuit interlocking protection
  1. คำแนะนำในการคัดเลือก
  2. Select contact configuration based on load power: 2Z for 10A loads, 2ZS/3ZS for 5A loads, 4ZS for 3A loads
  3. For harsh environments, prioritize versions with indicator lights (Type B) or arc shields (Type M)
  4. For DC control circuits, it is recommended to select versions with surge suppression (Type B) to protect coils and control equipment
  5. For frequent switching scenarios, give priority to its advantages of 3×10⁵ electrical life and 1×10⁷ mechanical life

Selection and Replacement Comparison Manual for Chint NJX-13FW and Equivalent Relays of Mainstream Brands

  1. Overview of Core Parameter Comparison (Priority Order)
Brand & ModelContact ConfigurationจัดอันดับปัจจุบันMaximum Switching VoltageCoil Power Consumptionชีวิตไฟฟ้าชีวิตเครื่องกลProtection Gradeวิธีการติดตั้งMatching Socket
Chint NJX-13FW2ซี(10ก)/2ZS/3ZS(5ก)/4ZS(3ก)3A/5A/10A250VAC/125VDCดี.ซี:0.9W3×10⁵ operations1×10⁷ operationsIP6K8 (Sealed)Top/side flange, PCB, plug-inCZTO8A-E/CZTO14A-E
เครื่องปรับอากาศ:1.8VA
Schneider RXM2AB2P72CO(10ก)10ก250VAC/30VDCดี.ซี:1W1×10⁶ operations1×10⁷ operationsIP20Plug-in type (16mm width)RXM4AB1P7
เครื่องปรับอากาศ:2VA
Omron LY2-DC242CO(10ก)10ก250VAC/30VDCดี.ซี:1W1×10⁶ operations1×10⁷ operationsIP40Plug-in type (standard 8-pin)PYF08A-E
เครื่องปรับอากาศ:2.4VA
Siemens 3RH2122-1BB402NO+2NC(10ก)10ก250VAC/30VDCดี.ซี:1.2W1×10⁶ operations1×10⁷ operationsIP20Plug-in type (14-pin)3RH1921-1HA11
เครื่องปรับอากาศ:3VA
ABB NF21E-102NO+2NC(10ก)10ก250VAC/30VDCดี.ซี:1W1×10⁶ operations1×10⁷ operationsIP20Plug-in typeNF21E-10 Socket
เครื่องปรับอากาศ:2.5VA
  1. Detailed Technical Parameter Comparison (By Category)
  2. Contact System Parameters
รายการพารามิเตอร์Chint NJX-13FWSchneider RXM2AB2P7Omron LY2-DC24Siemens 3RH2122-1BB40Remarks
Contact MaterialSilver alloy (oxidation-free patent)Silver-nickel alloySilver alloySilver alloyNJX-13FW has zero-arc feature
2Z/2CO Load10A/220VAC10A/250VAC10A/250VAC10A/250VACBasic load capacity is consistent
10A/28VDC10A/30VDC10A/30VDC10A/30VDC
3ZS/3CO Load5A/220VAC5A/250VAC5A/250VAC5A/250VACNJX-13FW offers 3ZS configuration
5A/28VDC5A/30VDC5A/30VDC5A/30VDC
4ZS/4CO Load3A/220VAC3A/250VAC3A/250VAC3A/250VACNJX-13FW offers 4ZS configuration
3A/28VDC3A/30VDC3A/30VDC3A/30VDC
Maximum Switching Power2ซี:2200VA/280W2500VA/300W2500VA/300W2500VA/300WMainstream brands have slightly higher power
2ZS/3ZS:1100VA/140W
4ZS:660VA/84W
Dielectric Withstand Voltage1500VAC between open contacts1500VAC (all circuits)1500VAC (all circuits)1500VAC (all circuits)Coil-contact voltage of NJX-13FW is slightly lower
500VAC between coil & ผู้ติดต่อ
  1. Coil & Action Characteristic Parameters
    รายการพารามิเตอร์Chint NJX-13FWSchneider RXM2AB2P7Omron LY2-DC24Siemens 3RH2122-1BB40Remarks
    Rated Voltage Rangeเครื่องปรับอากาศ:24V~380Vเครื่องปรับอากาศ:24V~230Vเครื่องปรับอากาศ:24V~230Vเครื่องปรับอากาศ:24V~230VCoverage range is basically consistent
    ดี.ซี:6V~220Vดี.ซี:6V~240Vดี.ซี:6V~240Vดี.ซี:6V~240V
    Pick-up VoltageDC≤75%UnDC≤75%UnDC≤75%UnDC≤75%UnMinimal difference
    AC≤80%UnAC≤85%UnAC≤85%UnAC≤85%Un
    Drop-out VoltageDC≥10%UnDC≥10%UnDC≥10%UnDC≥10%UnConsistent with standards
    AC≥20%UnAC≥20%UnAC≥20%UnAC≥20%Un
    Operation Time≤25ms≤20ms≤20ms≤20msMainstream brands have slightly faster response
    Release Time≤25ms≤20ms≤20ms≤20msMainstream brands have slightly faster response
    Surge SuppressionOptional Type B (with diode)Built-in surge suppressionOptional with surge suppressionBuilt-in surge suppressionNJX-13FW is optional configuration
  2. Physical & Environmental Parameters
รายการพารามิเตอร์Chint NJX-13FWSchneider RXM2AB2P7Omron LY2-DC24Siemens 3RH2122-1BB40Remarks
ขนาด27.5×21.5×35.5mm29×16×38mm29×18×36mm30×22×40mmNJX-13FW is more compact
น้ำหนักApprox. 35gApprox. 40gApprox. 38gApprox. 42gNJX-13FW is lighter
Operating Temperature-25°C~+55°C-25°C~+55°C-25°C~+55°C-25°C~+55°CConsistent with standards
Relative Humidity95% (at 25°C)95% (at 25°C)95% (at 25°C)95% (at 25°C)Consistent with standards
  1. Socket Compatibility
    Contact ConfigurationChint Matching SocketSchneider Matching SocketOmron Matching SocketCross-brand Replacement Suggestion
    2ซี (8-pin)CZTO8A-ERXM4AB1P7PYF08A-EPin arrangement is consistent, direct replacement available
    3ZS/4ZS (14-pin)CZTO14A-ERXM4AB2P7PYF14A-EPin arrangement is consistent, direct replacement available

    Selection and Replacement Decision Matrix (By Application Scenario)

Application ScenarioPriority Recommended ModelReplacement NotesCore Advantage Selection
Harsh environments (dust/humidity/low air pressure)Chint NJX-13FWSealed protection, zero-arc explosion-proofOxidation-free & zero-arc + IP6K8 protection
การควบคุม PLC (standard load)Schneider RXM2AB2P7Slightly higher coil power consumption, faster responseGood brand compatibility, sufficient spare parts
Omron LY2-DC24
Frequent switching (high life requirement)Omron LY2-DC24Electrical life of 1×10⁶ operations (higher than NJX-13FW)Long-life design, stable and reliable
Schneider RXM2AB2P7
Compact installation (space-constrained)Chint NJX-13FWDimensions of 27.5×21.5×35.5mm (smallest)Small size, light weight
Flange mounting requirementChint NJX-13FWOnly model supporting top/side flange mountingFlexible installation, suitable for special cabinets
Cost-sensitive projectsChint NJX-13FWPrice is about 60%-70% of imported brandsHigh cost performance, performance meets industrial standards
  1. Key Replacement Points and Risk Tips
  2. Three Elements for Safe Replacement
  3. การจับคู่พารามิเตอร์ทางไฟฟ้า: Ensure contact rated current/voltage ≥ original load, consistent coil voltage, and corresponding surge suppression configuration
  4. Mechanical Dimension Compatibility: For plug-in installation, confirm pin quantity and arrangement consistency; for PCB installation, verify pad positions
  5. Environmental Adaptation: For replacement in harsh environments, prioritize protection grade to avoid failures caused by insufficient sealing
  6. Risk Avoidance Measures

Zero-arc application scenarios: Must select Chint NJX-13FW; no other brands have this patented technology

Explosion-proof occasions: Confirm product explosion-proof certification; only NJX-13FW has explosion-proof current breaking patent

Special installation: Top/side flange mounting is only available for NJX-13FW; no other brands offer this mounting method

  1. Summary and Procurement Suggestions
  2. Direct Replacement with Same Parameters: Under standard working conditions, Chint NJX-13FW is fully compatible with Schneider RXM series, Omron LY series, and Siemens 3RH series in core parameters such as contact load and coil voltage, allowing direct interchangeability
  3. Differentiated Advantage Selection:

Harsh environments: Chint NJX-13FW with oxidation-free & zero-arc + IP6K8 sealing is the only choice

Standard working conditions: Imported brands (Schneider/Omron) with sufficient spare parts and high brand recognition