IFK3006-BPKG/AM/P/US IFT245 belongs to IFM IT hygienic all-metal inductive sensor series. It is designed for food and pharmaceutical applications with cleaning requirements. Featuring an all-metal sensing face, it can withstand high-pressure spray cleaning. ✅ Key Specifications Item Parameter Dimension M12×1, overall length 70 mm Sensing distance 6 มม, Non-flush mount (NF) Output type 3-wire DC PNP ...

  • รายละเอียดสินค้า

IFK3006-BPKG/AM/P/US

IFT245 belongs to ไอเอฟเอ็ม IT hygienic all-metal inductive sensor ชุด. It is designed for food and pharmaceutical applications with cleaning requirements. Featuring an all-metal sensing face, it can withstand high-pressure spray cleaning.

✅ Key Specifications

รายการพารามิเตอร์
มิติM12×1, overall length 70 มม
ระยะการตรวจจับ6 มม, Non-flush mount (NF)
ประเภทเอาต์พุต3-wire DC PNP Normally Open (เลขที่)
แรงดันไฟฟ้า10~30 โวลท์ดีซี
การสลับความถี่250 เฮิรตซ์
กระแสโหลดสูงสุด100 มิลลิแอมป์
ฮิสเทรีซีส1~20% Sr
Reduction factorSteel=1; Stainless steel=1; Brass=0.9; Aluminium=0.8; Copper=0.6
อุณหภูมิแวดล้อม0~100 ℃
การป้องกันทางเข้าIP69K (High-pressure washdown)
Max pressure on sensing faceขึ้นไป 100 บาร์
การป้องกันการป้องกันการกลับขั้ว, ป้องกันการลัดวงจร, การป้องกันการโอเวอร์โหลด
วัสดุตัวเรือนสแตนเลส, all-metal sensing face, food-grade material
การรับรองซีอี, คิวลัส, อีเอซี, EC1935/2004, อย

📌 Model Code Definition (IFT Series)

ถ้า: Inductive proximity sensor

ต: Hygienic all-metal series, wash & ทนต่ออุณหภูมิสูง, dedicated for food & อุตสาหกรรมเครื่องดื่ม

245: ม12, 6 มม. ไม่ฟลัช, เลขที่ พี.เอ็น.พี, 70 ความยาวมม, ขั้วต่อ M12

🧩 Construction & สายไฟ

การเชื่อมต่อ: ขั้วต่อตัวผู้ M12 4 ขา

การกำหนดพิน:

  1. สีน้ำตาล: +24วี
  2. สีฟ้า: 0วี
  3. สีดำ: PNP ไม่มีเอาต์พุต
  4. ไม่ได้ใช้

🎯 การใช้งานทั่วไป

อาหาร & เครื่องดื่ม, pharmaceutical and dairy production lines; CIP/SIP online cleaning equipment; workstations with frequent thermal cycling and high-pressure spray; metal workpiece presence detection and limit positioning.

ข้อดี: All-metal sensing face. Unlike conventional sensors with plastic front caps, it resists cracking and material buildup which causes bacterial growth. It withstands alkaline/acidic detergent flushing and thermal shock.

⚠️ Installation Notes

  1. Non-flush mounting: The sensor front end must NOT be embedded in metal. Sufficient clearance must be reserved for surrounding metal, otherwise the sensing distance will be reduced.
  2. Recommended target: Mild steel. Sensing range decreases when detecting aluminium or copper, so installation margin should be reserved.
  3. High-pressure cleaning: Direct spray from high-temperature high-pressure water gun is permitted, but avoid mechanical impact to the sensing face.

🔁 Alternative Model Reference

IFT244: มิติเดียวกัน, PNP Normally Closed

IFT246: มิติเดียวกัน, NPN เปิดตามปกติ

IFT259: ม12, 5 mm flush mount version

IGT247: ม18, 5 มม. ตัวยึดแบบฝัง, hygienic all-metal

🛠️ Common Troubleshooting

  1. ไม่มีเอาท์พุต: Check supply polarity (reverse polarity protected, but long-term reverse connection is not recommended); corrosion inside M12 connector due to water ingress; target beyond effective working distance (≤4.9 mm).
  2. การกระตุ้นที่เป็นเท็จ: Strong nearby metal interference; temperature approaching 100 ℃ limit; cable routed in parallel with power cables causing EMI.
  3. สัญญาณเป็นระยะ: ขั้วต่อหลวม, water ingress after high-pressure wash, material buildup on sensing face.

📎 Additional Information

ไม่มี IO-ลิงค์, discrete on/off version only

น้ำหนักประมาณ. 31 ก

IFM IFT245 Typical Application Cases

Core advantages summary: M12 hygienic 316L stainless steel, IP69K, acid & alkali detergent resistant, thermal shock 0~100 ℃, sensing face pressure rating up to 100 บาร์, เลขที่ พี.เอ็น.พี, 6 มม. ไม่ฟลัช. Specially designed for hygienic production lines requiring daily CIP/SIP and high-pressure washdown.

กรณี 1: Filling head position detection on dairy filling lines (ที่พบบ่อยที่สุด)

Working condition: Stainless steel filling valves on fresh milk/yogurt aseptic filling stations. Daily CIP hot alkaline cleaning and direct high-pressure water spray, repeated thermal cycling from ambient to 85 ℃, corrosive detergents.

การทำงาน: Detect position of metal piston on filling cylinder. PLC allows material discharge only after confirming filling head is lowered in place.

Selection reasons

  1. IP69K rated for direct high-pressure washdown. All-metal front without plastic end cap prevents milk residue accumulation and bacterial growth, compliant with FDA / EC1935 food contact material requirements.
  2. Tolerates repeated thermal shock; conventional plastic-face sensors tend to crack and leak under such conditions.
  3. Compact M12 thread fits narrow space near filling valves; stable detection for stainless steel targets with 6 mm sensing range.

บันทึก: Non-flush mounting required. Reserve clearance around adjacent metal to avoid sensing distance attenuation.

กรณี 2: Gripper position detection on PET bottle aseptic blow-fill-cap lines

Working condition: Aseptic cold filling line with daily disassembly cleaning, acidic disinfectant spray, ความชื้นสูง, high-speed reciprocating movement of metal grippers.

การทำงาน: Confirm stainless steel bottle gripper fully clamped, preventing false filling of empty holders and bottle bursting.

Pain point solved: Plastic front caps of standard proximity switches corrode and blister under disinfectant spray. IFT245 one-piece all-metal construction resists disinfectant spray and delivers stable signal under vibration. 250 Hz switching frequency matches fast gripper motion.

กรณี 3: Cutting / conveyor limit for meat processing

Working condition: Ham & cooked meat production line, splashing brine, blood and grease. Daily high-pressure hot water + alkaline detergent wash, high humidity environment.

การทำงาน: Limit detection for stainless steel baffles and conveyor push blocks, verify pusher mechanism fully retracted.

ไฮไลท์: 316L stainless steel housing resists brine corrosion; sensing face withstands minor mechanical impact; gold-plated contacts in M12 connector reduce oxidation risk in humid environments.

กรณี 4: Position feedback of hopper doors for tablet presses / capsule fillers in solid dosage pharmaceutical

Working condition: GMP clean room, CIP cleaning, intermittent high-temperature steam purging. Clean area requires zero dead space for dust accumulation.

การทำงาน: Detect open/closed status of stainless steel hopper flip door. Interlock protection to prevent powder leakage once door locking is confirmed.

คุณสมบัติ: Hygienic dead-space-free design; laser-etched nameplate will not peel off after repeated cleaning. Temperature range covers high cleaning temperature and meets GMP requirements for clean equipment.

กรณี 5: Tray presence detection for food retort / pasteurization lines

Working condition: Hot water pasteurization with cyclic temperature 0~95 ℃. Exterior of equipment undergoes daily high-pressure washdown, metal trays entering and exiting retort chamber.

การทำงาน: Confirm stainless steel tray in place before chamber door closes and sterilization cycle starts.

Fitment: Wide temperature range with thermal shock resistance. Sealing integrity maintained under splashing water and steam; sensing face rated for 100 แรงดันบาร์.

กรณี 6: Stainless tray counting / presence detection for baking oven conveyor

Working condition: Cooling section after oven, hot baking trays, grease and flour dust, daily hot water cleaning.

การทำงาน: Detect tray presence and counting on conveyor; interlock to prevent conveyor blockage.

บันทึก: Sensing distance reduces when detecting aluminium trays, installation margin must be reserved (reduction factor Al=0.8).

Extended non-food hygienic applications (less common but feasible)

Position feedback for valve actuators on pharmaceutical purified water pipelines with periodic sodium hypochlorite flushing; limit sensing for agitator mechanisms on small hygienic emulsification tanks.

General Site Implementation Guidelines (Applicable to all cases)

  1. การติดตั้ง: Non-flush installation, อย่าฝังเข้าไปในโลหะ. Mild steel target recommended; best performance on stainless steel.
  2. เคเบิล: M12 4-pin A-coded connector. Food-grade washdown resistant M12 cable recommended.
  3. การป้องกัน: Avoid prolonged direct high-pressure jet hitting the thread and connector seam.
  4. Anti-fault measures: Route sensor cables away from high-power solenoid valves and motors to avoid EMI false triggering.
  5. เอาท์พุต: เลขที่ พี.เอ็น.พี, compatible with mainstream hygienic PLCs such as Siemens and Rockwell Automation.

Alternative Models within the Series

Normally closed version: IFT244

NPN normally open: IFT246

M12 flush mount 5 มม: IFT259

IFM IT Hygienic All-Metal Inductive Proximity Sensor List (IFT / IGT / IIT / IET, series of IFT245)

Series common features: 316ล (1.4404) all-metal sensing face, IP69K, max pressure rating 100 บาร์, 0~100 ℃, อย / EC1935 food approval, M12 4-pin A-coded connector, 3-wire DC 10~30VDC.

Naming rule: IFT=M12, IGT=M18, IIT=M30, IET=M8; qf=flush/semi-flush, nf=non-flush; NO=Normally Open, NC=Normally Closed

IFT (M12×1, same housing sub-series as IFT245)

แบบอย่างระยะการตรวจจับการติดตั้งเอาท์พุตOverall Length mmหมายเหตุ
IFT2403 มมFlush qfเลขที่ พี.เอ็น.พี60Short range flush, food hygienic
IFT2443 มมFlush qfเลขที่ พี.เอ็น60NPN variant of IFT240
IFT2456 มมNon-flush nfเลขที่ พี.เอ็น.พี70Main model in this document
IFT2466 มมNon-flush nfเลขที่ พี.เอ็น70NPN variant of IFT245
IFT2476 มมNon-flush nfพีเอ็นพี เอ็นซี70Normally closed version
IFT2486 มมNon-flush nfเอ็นพีเอ็น เอ็นซี70NPN normally closed
IFT2595 มมFlush qfเลขที่ พี.เอ็น.พี45Compact short body 45mm
IFT2606 มมNon-flush nfเลขที่ พี.เอ็น.พี45Short housing for confined space
IFT2007 มมNon-flush nfเลขที่ พี.เอ็น.พี50Older M12 all-metal
IFT2054 มมFlush qfPNP/NPN programmable70Switchable output

IGT (M18×1 hygienic all-metal, same IT series)

แบบอย่างระยะการตรวจจับการติดตั้งเอาท์พุตOverall Length mmหมายเหตุ
IGT2475 มมFlush qfเลขที่ พี.เอ็น.พี70Most popular M18 hygienic model
IGT25012 มมNon-flush nfเลขที่ พี.เอ็น70Long sensing range M18
IGT26110 มมFlush qfเลขที่ พี.เอ็น.พี45Short housing M18
IGT26212 มมNon-flush nfเลขที่ พี.เอ็น.พี45Short housing M18 non-flush

IIT (M30×1.5 hygienic all-metal, same IT series)

แบบอย่างระยะการตรวจจับการติดตั้งเอาท์พุตOverall Length mmหมายเหตุ
IIT24518 มมFlush qfเลขที่ พี.เอ็น.พี50M30 flush
IIT24625 มมNon-flush nfเลขที่ พี.เอ็น.พี65M30 ultra-long sensing distance

IET (M8×1 compact hygienic all-metal, same IT series)

แบบอย่างระยะการตรวจจับการติดตั้งเอาท์พุตOverall Length mmหมายเหตุ
IET2003 มมSemi-flush qfเลขที่ พี.เอ็น.พี45Smallest M8 hygienic type
IET2015 มมNon-flush nfเลขที่ พี.เอ็น.พี45M8 non-flush

🔎 Quick Selection Reference (Based on IFT245)

Same M12, 6 มม. ไม่ฟลัช, NPN → IFT246

Same M12, 6 มม. ไม่ฟลัช, Normally Closed → IFT247

ม12, 5 mm flush, short 45mm body for tight space → IFT259

พื้นที่จำกัด, short housing 6 mm non-flush M12 → IFT260

Longer detection range, switch to M18 hygienic type → IGT247 (5 mm flush) / IGT250 (12 มม. ไม่ฟลัช)

✅ General Series Notes

  1. All sensors adopt all-metal sensing face, not PEEK plastic front used on standard sensors; designed exclusively for CIP/SIP cleaning applications.
  2. Reduction factor: Steel=1, Stainless steel=1, Brass=0.9, Aluminium=0.8, Copper=0.6.
  3. Mounting restriction: Non-flush (nf) models cannot be embedded in metal. Clearance must be reserved for surrounding metal or sensing distance will drop. Flush(qf) versions can be embedded in metal.
  4. Uniform M12 A-coded 4-pin male connector for all; washdown food-grade cable recommended.
  5. ไม่มี IO-ลิงค์, pure discrete switching output. IO-Link capability available on other IFM all-metal series.

ความแตกต่างที่สำคัญ: IC Series (Do not confuse)

IxC series also has all-metal sensing face, but it is developed for machine tool cutting fluid environments. No food hygienic certifications, cannot replace IT food-grade sensors.