3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

NewsTrade News

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination (Cable Terminal)

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination (Cable Terminal)

  1. Model Segment Interpretation
SegmentMeaningRemarks
7622Product series code3M QTIII 3rd generation cold shrink technology, 8.7/15kV 3-core indoor termination series
PSTStructural type codePre-expanded Silicone Termination, integrated stress control design
G2Specification adaptation codeSuitable for 3×70~3×120 mm² cable conductor, insulation outer diameter 16.0~28.0 mm
Implied ParameterVoltage level / Installation environment8.7/15kV (15kV system), indoor type (without rain shed), QTIII 3rd generation technology

 

  1. Core Specification Parameters

Electrical Parameters

ParameterValueDescription
Rated Voltage8.7/15 kV (Max 20 kV)Suitable for medium voltage power system, compliant with IEC 60502 standard
Maximum System Voltage17.5 kVMeets Class 1 termination requirements of IEEE 48-1990 standard
Applicable Cable TypeWire shield / Tape shield XLPE/EPR insulated power cableDedicated for polymer insulated cables; not applicable to oil-impregnated paper insulated cables
Insulation Outer Diameter Range16.0–28.0 mmTypical insulation outer diameter for 3×70 mm² cable (approx. 18–22 mm)
Power Frequency Withstand Voltage45 kV / 1 minFactory test standard to ensure insulation reliability
Partial Discharge≤5 pCQTIII 3rd generation technology, better performance than QTII series (≤10 pC)
Switch Impulse Withstand Voltage95 kVSatisfies system overvoltage protection requirements

Mechanical & Environmental Parameters

ParameterValueDescription
Insulation MaterialHigh dielectric constant creepage-resistant silicone rubberPermanent radial pressure, excellent weather resistance and aging resistance
Ingress ProtectionIP68Fully dustproof and waterproof, suitable for humid indoor environments
Operating Temperature-40℃ ~ +90℃Wide temperature range, adapts to extreme climatic conditions
Mechanical Service Life≥30 yearsMaintenance-free design with long service life
Installation MethodCold shrink type (no heating tools required)Automatically shrinks by pulling out the support core rope for easy installation
WeightApprox. 0.8 kg/setComplete with all components, convenient for on-site installation
ColorBlackStandard industrial color, stain-resistant

Applicable Cable Parameters

ParameterApplication RangeRemarks
Conductor Cross-section3×70–120 mm²Suitable for mainstream medium voltage distribution cable cross-sections
Conductor MaterialCopper / AluminumCompatible with two mainstream conductor materials, no special model required
Insulation Thickness8–12 mmStandard insulation thickness for 15kV cables
Shield TypeBraided copper wire shield / Wrapped copper tape shieldCompatible with two common shielding structures
Overall Cable Outer Diameter35–50 mmTypical outer diameter range for 3-core cables
  1. Accessory List
Accessory NameQuantityPurpose
QTIII Cold Shrink Termination Body (with integrated stress control)3 pcsProvide insulation and stress control, grease-free design
Cold Shrink Branch Seal Sleeve1 pcSeal cable branch to prevent moisture ingress
Constant Force Spring Grounding Device3 pcsShield layer grounding connection, no welding or copper binding wire required
Copper Mesh Grounding Wire3 pcsShield layer grounding connection to ensure reliable grounding
Phase Color Marker (Yellow/Green/Red)3 setsPhase identification, compliant with power safety regulations
Cleaning Kit (CC-2)1 setPre-clean cable surface to remove oil stains and impurities
Sealing Strip6 pcsSeal termination top and cable branch to enhance waterproof performance
Installation Instruction Manual1 copyDetailed illustrated installation guidance
Support Core Rope Pulling Tool1 pcAssist steady rope pulling during installation to avoid termination distortion
  1. Competitor & Cross-Brand Comparison
BrandModelMain DifferenceApplication Scenario
Original 3M7622-S-4Outdoor type with rain shed, 15kV, 3×70–120 mm²Outdoor medium voltage distribution equipment connection
Original 3M5601PST-G-CNQTII 2nd generation, 15kV, 3×35–70 mm²Indoor power distribution, budget-limited projects
ABBCold Shrink Termination SeriesSimilar structure, slightly higher price, same applicable rangePower system supporting, brand preference
SchneiderCold Shrink Termination SeriesDifferent stress control design, slight difference in installation stepsIndustrial automation system supporting
Domestic AlternativeChangyuan CYLS-15/3.1Price about 1/2–2/3 of 3M, performance meets national standardsBudget-sensitive projects, non-critical circuits
Domestic AlternativeWalen WRS-15/3.1High cost performance, same applicable rangeGeneral distribution projects, bulk procurement
  1. Selection Guidelines & Replacement Solutions

5.1 Key Selection Parameters

Voltage Level Matching: Confirm system voltage is 8.7/15kV; not applicable for systems below 10kV or above 20kV.

Cable Specification Confirmation:

Conductor cross-section: Well compatible within 3×70–120 mm² range.

Insulation outer diameter: Must be within 16.0–28.0 mm with tolerance ≤±1mm, ensuring sufficient radial compression of cold shrink termination.

Shield type: Only applicable to wire/tape shielded cables; not for non-shielded or aluminum sheathed cables.

Installation Environment:

Indoor application: Select 7622PST-G2 (indoor type), compact structure without rain shed.

Outdoor application: Choose outdoor type 7622-S-4 with UV resistance and weatherability.

Installation Tools: No heating tools required; only basic electrician tools and cleaning supplies, single-person installation available.

5.2 Recommended Replacement Solutions

Application ScenarioRecommended Replacement ModelAdvantages
Direct replacement with same specification3M 7622PST-G2 (3×70–120 mm² applicable)Original genuine product, fully compatible, QTIII 3rd generation technology
Small cross-section adaptation3M 7620PST-G1 (3×35–70 mm² applicable)Fits smaller cross-section cables with lower cost
Large cross-section upgrade3M 7624PST-G1 (3×150–240 mm² applicable)Compatible with larger cross-section cables, reserved for future capacity expansion
Outdoor installation3M 7622-S-4Dedicated outdoor type with rain shed, excellent UV resistance
Cost optimizationChangyuan CYLS-15/3.1High-quality domestic alternative, obvious price advantage, performance meets national standards

5.3 Installation Precautions

  1. Cable Pre-treatment

Thoroughly clean cable surface with 3M CC-2 cleaning kit to remove oil stains and oxide layer.

Keep smooth transition at shield cut-off position to avoid tip discharge; professional tools are recommended.

  1. Installation Procedure

QTIII series: Integrated design without additional stress control mastic required; install branch seal sleeve first, then cold shrink termination body.

Pull the core rope steadily at constant speed to avoid termination distortion and ensure close fitting with cable surface.

  1. Safety Regulations

Installers must hold valid medium voltage cable construction qualification; confirm cable power off and grounding before construction.

Construction site shall be dry and clean; avoid installation in rainy or humid conditions.

  1. Quality Control

Perform insulation resistance test (≥1000 MΩ) and partial discharge test (≤5 pC) after installation.

Record installation date and test data for future maintenance and traceability.

  1. Product Features Summary
  2. QTIII 3rd Generation Technology: Grease-free application, lower partial discharge (≤5 pC), easier installation and higher reliability.
  3. Integrated Design: Built-in stress control unit effectively reduces partial discharge risk and improves insulation reliability.
  4. Easy Installation: Cold shrink technology requires no heating tools; single-person installation saves construction time and cost.
  5. Strong Environmental Adaptability: Operating temperature -40℃~+90℃, IP68 protection grade, suitable for various harsh indoor environments.
  6. Wide Compatibility: Compatible with multiple specifications of XLPE/EPR insulated cables with high versatility, reducing inventory pressure.
  7. Maintenance-free Design: Silicone rubber provides permanent radial pressure without regular inspection, lowering operation and maintenance costs.