Wieland SNA-4053-K-A Safety Relay - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

Wieland SNA-4053-K-A Safety Relay - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

كهربائي/

Wieland SNA-4053-K-A Safety Relay

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains) 4053: Specification code K: Pluggable screw terminals A: Supply voltage AC/DC 24 V Suffix differentiation for the series: A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version Core Specifications & تقييمات السلامة ...

  • تفاصيل المنتج

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains)

4053: كود المواصفات

ك: Pluggable screw terminals

أ: Supply voltage AC/DC 24 V

Suffix differentiation for the series:

A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version

  1. المواصفات الأساسية & تقييمات السلامة
  2. شهادات السلامة

بل ه / فئة 4 (في ايزو 13849-1)

SIL CL3 (في 62061)

  1. تكوين الاتصال

3 safety normally open contacts (13-14 / 23-24 / 33-34)

1 normally closed signal contact (41-42)

  1. البيانات الكهربائية

إمداد: 24 الخامس التيار المتناوب/تيار مستمر

Continuous rated current Ith: 8 أ

ايه سي-15: 230 V / 5 أ; دي سي-13: 24 V / 5 أ

تصاعد: من 35 مم السكك الحديدية; عرض 22.5 مم

  1. Input Functions

Dual-channel safety circuit (S11/S12, S21/S22)

Supports cross-channel short-circuit monitoring

إعادة الضبط اليدوي (with reset monitoring)

Suitable for: أزرار التوقف في حالات الطوارئ, safety gate switches, magnetic safety switches, safety light curtains

  1. Typical Wiring Logic
  2. أ1(+), A2(-): 24 إمدادات الطاقة V
  3. S11-S12, S21-S22: Dual-channel safety devices (normally closed signal)
  4. S33-S34: Reset terminals (connect external normally open reset button; shorted = automatic reset)
  5. 13-14 / 23-24 / 33-34: Safety outputs (for controlling main contactors)
  6. 41-42: Normally closed fault feedback signal
  7. Model Correction & مرجع بديل

⚠️ The most frequently confused model on the market: SNA4043K-A (4043, easily mistaken for 4053)

⚠️ Important Verification Conclusion

SNA4053K-A is NOT an official standard model in Wieland catalogues, it is highly likely a transcription error:

  1. Most common miswriting: SNA4043K-A (رقم الجزء. R1.188.1810.0)

إعادة التعيين التلقائي, no reset monitoring; dual-channel with short-circuit monitoring

  1. Alternative similar model: SNA4063K-A

إعادة الضبط اليدوي (with reset monitoring) — this is the core difference from SNA4043

Model rules:

SNA4043K-A: إعادة التعيين التلقائي

SNA4063K-A: إعادة الضبط اليدوي (reset button monitoring)

Both models share identical contact configuration, safety rating and dimensions; only reset logic differs.

Quick Selection Comparison Table

نموذجManufacturer Part No.جهد الإمدادوضع إعادة الضبطنوع المحطة
SNA4043K‑AR1.188.1810.0تيار متردد/تيار مستمر 24 Vإعادة التعيين التلقائيPluggable screw K
SNA4063K‑AR1.188.1870.0تيار متردد/تيار مستمر 24 Vإعادة الضبط اليدوي (with reset monitoring)Pluggable screw K

Recommended Actions

  1. Verify the printed model on the physical nameplate of the unit;
  2. Confirm site requirements: Reset monitoring required or not

Emergency stop circuits generally require manual reset (SNA4063K-A)

Safety light curtain applications may adopt automatic reset (SNA4043K-A)

Application Scenarios of Wieland SNA Series مرحلات السلامة (SNA4043 / SNA4063)

This series achieves PL e / القطة 4 / SIL3 with dual-channel monitoring, primarily deployed for safety circuits on machine tools and automated production lines. Content is divided into supported safety signal types, industry applications, and key selection differentiation.

  1. Supported Safety Input Signals (Hardware Utilization)
  2. أزرار التوقف في حالات الطوارئ (dual normally closed contacts)

Most common application: Machine main emergency stop and zone emergency stop circuits.

Standard requirement: Emergency stop circuits prefer SNA4063K-A (manual reset with monitoring).

  1. Safety gate switches / Magnetic safety sensors

Interlock for protective doors, maintenance doors and perimeter fencing; power circuit cutout upon door opening.

  1. Safety light curtains

Hazard zone intrusion protection for presses, conveyor lines and robot stations.

Light curtain solutions commonly use SNA4043K-A (automatic reset).

  1. Two-hand control devices

For stamping and riveting equipment, preventing single-hand access to hazardous zones.

  1. Safety mats, safety bumpers

Perimeter intrusion detection around robot cells, automatic doors and lifting platforms.

  1. Major Industry & Equipment Applications

(1) Machine Tool Industry

مخارط CNC, machining centres, المطاحن, punching machines, آلات الانحناء

طلب: Protective door interlock, emergency stop circuits, safety light curtain protection

(2) Automated Production & Packaging Equipment

ماكينات التعبئة والتغليف, palletizers, conveyor lines, sorting equipment, labellers

Robot workstations, gantry robot safety fence interlock

(3) ممحاة & Plastics Industry

Injection moulding machines, بثق, blow moulding equipment: Safety gates, توقف الطوارئ, safety light curtains

(4) اللوجستية & Warehousing Equipment

Automated warehouses, lifts, shuttles, sorting lines

Lifting platforms, dock leveller safety interlocks

(5) الطاقة الجديدة & Lithium Battery Equipment

Cell assembly machines, electrolyte filling machines, sealing equipment, test tooling

Wieland products are widely adopted on export machinery to meet EU CE Machinery Directive requirements

(6) النجارة & Printing Machinery

Panel saws, آلات القطع, printing presses, die-cutting machine safety protection

(7) General Custom Automation

Custom test fixtures and assembly machines; deployed as core safety logic unit to cut off main contactors and servo power circuits.

  1. Critical Application Selection Comparison
نموذجوضع إعادة الضبطتطبيق نموذجي
SNA4043K‑Aإعادة التعيين التلقائيSafety light curtains, safety bumpers; system enables restart automatically after obstacle removal
SNA4063K‑Aإعادة الضبط اليدوي (with reset monitoring)أزرار التوقف في حالات الطوارئ, safety gate switches. Manual reset operation is mandatory before machine restart (required by machinery safety standards)

⚠️ SNA-4053-K-A is not an official Wieland standard model. It is almost certainly a nameplate transcription error; physical unit will be one of the two above variants.

  1. القيود & تطبيقات غير مناسبة
  2. Cannot directly drive high-power loads; safety contacts are intended to control contactor coils, not motors directly
  3. Not suitable for solenoid valves or high-frequency switching loads
  4. Cannot satisfy safety requirements higher than PL e / القطة 4 (this series already reaches Cat.4 maximum rating)

Selection Guidelines for Wieland SNA / SNO Safety Relays

Based on the SNA4043 / SNA4063 platform covered above; structured criteria ready for engineering proposals and procurement checks.

خطوة 1: Confirm Required Safety Rating (Mandatory Priority)

Compliant with ISO 13849-1 / في 62061

  1. PL & فئة

بل ه / القطة 4: Highest rating. For high-risk stations including robots, stamping, injection moulding, machine tools and lithium battery equipment (supported by all mainstream SNA variants)

ب ل د / القطة 3: Low-risk general automation and conveyor lines

  1. SIL Level

سيل 3 corresponds to PL e; preferred for machinery exported to EU

✅ Selection Rule: Do NOT downgrade safety rating for high-risk equipment.

خطوة 2: Determine Safety Input Channel Configuration (Dual Channel Is Standard)

Channel Modes

Dual-channel monitoring with cross short-circuit detection: Industry standard, fitted across all SNA variants. Compatible with dual normally closed safety devices (أوقف, safety gates, ستائر خفيفة)

Single channel: Only permitted for low-risk scenarios; available on selected SNO variants. NOT allowed for high-risk machinery.

Compatible Sensor Types

Emergency stop switches, mechanical safety gates: Dual normally closed (نورث كارولاينا)

Magnetic safety switches, safety light curtains: Dual NC / OSSD signals

⚠️ Two types of safety light curtains:

① OSSD solid-state output → Requires relay model supporting OSSD input

② Light curtain with relay converted contact output → Compatible with standard SNA4043 / SNA4063

خطوة 3: وضع إعادة الضبط (Most Common Source of Wrong Selection!)

Reset Typeمثال نموذجيطلبCompliance Note
إعادة الضبط التلقائيSNA4043K‑ASafety light curtains, safety bumpers, safety mats; system ready after obstacle clearedFORBIDDEN for emergency stop and safety gate circuits
إعادة الضبط اليدوي (with reset line monitoring)SNA4063K‑Aأزرار التوقف في حالات الطوارئ, machine protective safety gates; manual reset push required before restartMandatory recommendation per machinery safety standards; preferred for most complete machinery

Key Distinction:

Monitored reset detects open or short circuits on reset wiring and triggers safety lockout for superior safety. Simple unmonitored manual reset should be avoided on new projects.

خطوة 4: جهد الإمداد

Main Wieland options:

Suffix A = AC/DC 24 V (Automation standard, selected in 90% of projects)

Less common: 110 بطالة, 230 VAC — only for legacy retrofits

مثال: SNA4063K-A → A = AC/DC 24 العرض الخامس

خطوة 5: نوع المحطة (Identified by Suffix K / ج)

K = Pluggable screw terminals

المزايا: Vibration resistant, ideal for permanent cabinet installation and on-site maintenance (the unit in your photo uses K terminals)

C = Push-in spring terminals

المزايا: Fast wiring without screwdrivers; use cautiously under heavy vibration

مثال: SNA4063K-A

خطوة 6: Output Contact Configuration

Main Safety Outputs (For Power Circuit Cutoff)

SNA4043 / SNA4063: 3 اتصالات السلامة مفتوحة عادة

غاية: Wired in series with main contactor coils for redundant shutdown

Auxiliary Signal Contacts (PLC Feedback)

1 built-in normally closed fault contact

Opens upon safety activation or relay fault; used for alarm indicators and PLC signalling

ملاحظة الاختيار: If multiple feedback signals are required, add auxiliary relays. Safety contacts should not be expanded externally.

Contact Load Ratings

ايه سي-15: 230 V / 5 أ

دي سي-13: 24 V / 5 أ

👉 Never drive motors directly; only control contactor coils!

خطوة 7: تصاعد & المواصفات المادية

  1. تصاعد: Standard DIN 35 مم السكك الحديدية
  2. عرض: SNA40xx series 22.5 مم, compact design saving cabinet space
  3. التصنيف البيئي: IP20 (for cabinet installation only; not for outdoor direct deployment)

خطوة 8: Differentiate SNA vs SNO Series (Frequent Confusion)

SNA Series: Dual-channel safety monitoring, up to PL e Cat.4; for emergency stop, safety gates, ستائر خفيفة (your target series)

SNO Series: Predominantly single channel, lower safety rating generally PL d and below; low-cost basic solutions

Common Selection Pitfalls Checklist

  1. ❌ Misapplication: Using automatic reset SNA4043 for emergency stop circuits — violates machinery safety standards, fails third-party audit & شهادة CE
  2. ❌ Transcription error SNA-4053-K-A: No official model; physical unit is either SNA4043 or SNA4063
  3. ❌ Direct drive of solenoid valves or high-power loads with safety contacts → contact burnout and loss of safety function
  4. ❌ Mixing K screw terminals and C spring terminals, leading to mismatch on delivery
  5. ❌ Ignoring reset monitoring requirements → machine fails acceptance testing

Rapid Selection Workflow (For Field Engineers)

  1. Identify safety device: توقف اضطراري / safety gate → select SNA4063xx-A (monitored manual reset); Light curtain / safety bumper → SNA4043xx-A (automatic reset)
  2. Confirm supply voltage: Default AC/DC24V suffix A
  3. Select terminal type: Permanent cabinet installation → K screw terminal; high volume assembly for fast wiring → C spring terminal
  4. Verify safety rating: High-risk equipment requires PL e / القطة 4 / SIL3
  5. Confirm number of safety contacts sufficient for contactor control

Complete Official Model List of Wieland SNA40xx Safety Relays

Series Profile: safeRELAY SNA40xx dual-channel safety monitoring, بل ه / القطة 4 / SIL3, تركيب السكك الحديدية DIN;

⚠️ Important Notice: SNA-4053-K-A is NOT an official Wieland model, it is a transcription error. Official core variants are limited to 4043 / 4044 / 4063 / 4064;

Industry standard: Suffix A = AC/DC24 V (automation default). Specify A suffix for new orders.

  1. قواعد تسمية النموذج

`SNA 40XX [صالة][إعادة ضبط]-[Voltage Suffix]`

  1. SNA: Dual-channel safety monitoring base unit
  2. 40العشرين:

4043: 3 سلامة لا اتصالات, automatic reset (no reset monitoring)

4044: 4 سلامة لا اتصالات, automatic reset (no reset monitoring)

4063: 3 سلامة لا اتصالات, إعادة التعيين اليدوي (with reset circuit monitoring)

4064: 4 سلامة لا اتصالات, إعادة التعيين اليدوي (with reset circuit monitoring)

Last digit 3 = 3 سلامة لا اتصالات; Last digit 4 = 4 سلامة لا اتصالات

  1. Terminal Code

ك: Pluggable screw terminals (most widely used in projects)

ج: Pluggable Push-in spring terminals

  1. Extended Reset Suffix (KM/KE)

كم: Simple manual reset without monitoring; rarely specified for new projects

  1. Voltage Suffix

أ: تيار متردد/تيار مستمر 24 V (automation standard)

لا لاحقة: Fixed screw terminals (legacy models, التخلص التدريجي)

  1. Mainstream Models for Domestic Projects (24 الخامس التيار المتناوب/تيار مستمر)

SNA4043 Series | إعادة الضبط التلقائي, 3 Safety NO Contacts

النموذج الكاملWieland Part No.نوع المحطةتكوين الاتصالوضع إعادة الضبطتطبيق نموذجي
SNA4043K‑AR1.188.1810.0Pluggable screw K3 Safety NO + 1 NC Fault Contactإعادة التعيين التلقائي (no reset monitoring)Safety light curtains, safety bumpers, safety mats
SNA4043C‑AR1.188.1940.0Push‑in spring C3 Safety NO + 1 NC Fault Contactإعادة التعيين التلقائي (no reset monitoring)High volume cabinet fast wiring

SNA4044 Series | إعادة الضبط التلقائي, 4 Safety NO Contacts

النموذج الكاملWieland Part No.نوع المحطةتكوين الاتصالوضع إعادة الضبطتطبيق نموذجي
SNA4044K‑AR1.188.1860.0Pluggable screw K4 Safety NO + 1 NC Fault Contactإعادة التعيين التلقائي (no reset monitoring)Applications requiring multiple safety cutout circuits, light curtain systems
SNA4044C‑AR1.188.1960.0Push‑in spring C4 Safety NO + 1 NC Fault Contactإعادة التعيين التلقائي (no reset monitoring)Synchronous cutout of multiple contactors

SNA4063 Series | إعادة الضبط اليدوي (Monitored), 3 Safety NO Contacts【Preferred for Complete Machinery】

النموذج الكاملWieland Part No.نوع المحطةتكوين الاتصالوضع إعادة الضبطتطبيق نموذجي
SNA4063K‑AR1.188.1440.0Pluggable screw K3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringأزرار التوقف في حالات الطوارئ, machine safety gates, CE certified machinery (Most Popular)
SNA4063C‑AR1.188.1950.0Push‑in spring C3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringExport custom automation, fast cabinet wiring

SNA4064 Series | إعادة الضبط اليدوي (Monitored), 4 Safety NO Contacts

النموذج الكاملWieland Part No.نوع المحطةتكوين الاتصالوضع إعادة الضبطتطبيق نموذجي
SNA4064K‑AR1.188.1880.0Pluggable screw K4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringMulti‑group power circuit cutout, large machine tools
SNA4064C‑AR1.188.1970.0Push‑in spring C4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringSystems requiring synchronous shutdown of multiple contactors
  1. Legacy Non-Standard Voltage Models (Only For Equipment Replacement, Not Recommended For New Projects)

Fixed non-pluggable screw terminals (no suffix A)

SNA4043K: AC42~48 V / AC115 V / AC230 V

SNA4063K: AC230 V

ملحوظة: All new domestic machinery shall adopt AC/DC24 V models with suffix -A

  1. General Specifications Applicable to All Variants
  2. تصنيف السلامة: بل ه / القطة 4, سيل 3 (EN ISO13849-1, EN62061)
  3. Contact Ratings: ايه سي-15 230 V/5 A; دي سي-13 24 V/5 A
  4. تصاعد: من 35 مم السكك الحديدية; عرض 22.5 مم; IP20 (Cabinet installation only)
  5. سمات: Dual-channel cross short-circuit monitoring, EDM external device monitoring support, 3 status LED indicators
  6. الأسلاك: Supports single-channel / dual-channel connection modes
  7. Quick Selection Summary Table
Model Groupوضع إعادة الضبطCompatible Safety DevicesCompliance Restriction
SNA4043 / SNA4044إعادة الضبط التلقائيSafety light curtains, safety bumpers❌ NOT permitted for emergency stop and machine safety gate circuits
SNA4063 / SNA4064إعادة الضبط اليدوي (Monitored)Emergency stop switches, safety gate switches✅ Compliant with EN60204 machinery safety standards, accepted for CE audits
  1. Procurement Reminders
  2. If customer submits model `SNA-4053-K-A` → Confirm transcription error immediately. Check physical nameplate; the actual unit is almost certainly SNA4063K-A.
  3. Always include complete model + manufacturer part number in BOM to avoid delivery mismatch between K screw terminals and C spring terminals.
  4. Do not interchange automatic reset SNA4043 and monitored manual reset SNA4063; incorrect selection will lead to failed safety acceptance.
  5. Contact count selection: 3 contactors or less → SNA4063; ≥4 contactors requiring synchronous shutdown → select SNA4064.

السابق:

ترك الرد

ترك رسالة