ABB 2UEA001345 Phase Module Kit - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

ABB 2UEA001345 Phase Module Kit - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

NachrichtHandelsnachrichten

ABB 2UEA001345 Phase Module Kit

ABB 2UEA001345 (ACS 2040-PMK1000) 4kV Phase Module Kit

ABB 2UEA001345 is a dedicated phase module kit for ACS 2040 series 4kV medium-voltage frequency converters. It serves as the core power unit of the ACS2000 medium-voltage drive system, adopting 3-level IGBT topology. It is applicable to 4kV power grid systems with rated power ranging from 300-1000HP (225-750kW).

Its core strengths include high-reliability design (MTBF>100,000 hours), geringer harmonischer Ausgang (compliant with IEEE 519 Standard), modular structure for easy maintenance and replacement, and wide operating temperature range (-10℃ ~ +40℃). It is perfectly suited for general industrial loads such as fans, water pumps and compressors, which can effectively improve system energy efficiency (20%-40% Energieeinsparung) and reduce maintenance costs.

  1. Erklärung des Modellcodes
SectionCodeDefinition
Produktserie2UEASeries code for ABB medium-voltage inverter power modules (2UEA=ACS 2040 Serie, 2UEB=ACS 2000 Serie)
Part Number1345Unique identification code of phase module kit, corresponding to model ACS 2040-PMK1000
Anwendbare Spannung4kVMatches 4000V medium-voltage power grid system
ProdukttypPMK1000Phase Module Kit, Nennstrom: 1000A
Anwendbares SystemACS 2040Compatible with ABB ACS 2040 series medium-voltage inverters

Order Number: 2UEA001345 (Standard single packing)

Passendes Modell: 2UEA001141 (Complementary phase module of the same series)

  1. Main Technical Specifications
KategorieArtikelParameterBemerkungen
Grundlegende InformationenProdukttyp4kV Medium Voltage Inverter Phase Module Kit3-level IGBT topology, integrated drive and protection circuits
Applicable InverterACS 2040 Serie (ACS2000 Platform)Compatible with Frame 1 Größe (300-1000HP)
Nennspannung4kV (4000V)Betriebsspannungsbereich: 3.6~4.4kV
Nennstrom1000AMax peak current: 2000A (2 times rated value)
Power DevicesIGBT TypeHigh-voltage IGBT Module1700V/1200A, ABB customized version
Topologie3-level NPC (Neutral Point Clamped)Reduce dv/dt and motor insulation stress
Cooling ModeZwangsluftkühlungBuilt-in cooling fan, redundant design supported
Elektrische ParameterInput Frequency50/60Hz, ±5 %Compatible with global power grid standards
Schaltfrequenz2~8kHz (Einstellbar)Balance energy efficiency and noise performance
StromausfallCa. 1.2kW per moduleUnder typical working conditions
IsolationsklasseOvervoltage Category IV (IEC 60664)Meet insulation requirements of medium-voltage systems
Mechanical ParametersDimension (L×W×H)650×450×320mmStandard Frame 1 Größe
Nettogewicht48.5kgExcluding packaging
SchutzklasseIP20Suitable for cabinet installation
SchutzfunktionenÜberstromschutz2000A (2 times rated)Short-circuit response time <10μs
Überspannungsschutz4.4kVDC bus overvoltage protection
Over-temperature Protection100℃IGBT module overtemperature protection
Unterspannungsschutz3.6kVGrid undervoltage protection
Zertifizierungen & EinhaltungCE CertificateJaKonform mit EN 61800-5-1
UL CertificateJaMeet North American medium-voltage equipment standards
IEEE 519 EinhaltungJaTotal harmonic distortion <5%
  1. Full Model List of ACS 2040 Series Phase Modules
ModellBestell-Nr.NennspannungNennstromApplicable InverterNotizen
ACS 2040-PMK10002UEA0013454kV1000AACS 2040 Rahmen 1Standard phase module
ACS 2040-PMK10002UEA0011414kV1000AACS 2040 Rahmen 1Complementary phase module
ACS 2040-PMK12002UEA0013464kV1200AACS 2040 Rahmen 1High current version
ACS 2040-PMK8002UEA0013474kV800AACS 2040 Rahmen 1Low current version
ACS 2040-PMK1000-6kV2UEA0013486kV1000AACS 2040 Rahmen 26kV dedicated version
  1. Ersatz & Equivalent Models

4.1 Internal ABB Replacement

Altes ModellNeues ModellReplacement Description
ACS 1040-PMK1000ACS 2040-PMK1000 (2UEA001345)Upgraded to 3-level topology, efficiency increased by 2%, harmonic distortion reduced by 30%
ACS 2040-PMK800 (2UEA001347)ACS 2040-PMK1000 (2UEA001345)Higher current model in the same series, wider power coverage

4.2 Cross-brand Equivalent Products

MarkeÄquivalentes ModellVorteile
SiemensSINAMICS GM150 Power ModuleSuperior 3-level topology, lower dv/dt, better motor insulation protection
Schneider ElectricAltivar 6100 Medium Voltage ModuleEasier maintenance with modular design, higher MTBF (>100,000 hours)
Mitsubishi ElectricMV-VFD Power ModuleWider applicable voltage range (3.6-4.4kV), stronger environmental adaptability
  1. Anwendungsszenarien & Branchenfälle

5.1 Empfohlene Anwendungen

AnwendungstypTypical Working ConditionsKernvorteile
Industrial FansPower plant induced draft fans, cement plant kiln fans, steel plant dust removal fansWide speed regulation range (0.1-100Hz), 30%-40% Energieeinsparung
Industrial Water PumpsWater plant high-pressure water supply pumps, mine drainage pumps, petrochemical circulating pumpsSoft start without impact, reduce pipeline stress and extend service life
KompressorenAir compressors, natural gas compressors, refrigeration compressorsPrecise pressure control, reduce no-load loss and improve energy efficiency
FördererLong-distance mine conveyors, port container conveyorsSmooth speed regulation, avoid material accumulation and mechanical wear
General Industrial EquipmentMixer, Brecher, Extruder, usw.Modular design for convenient maintenance, MTBF>100,000 hours

5.2 Not Recommended Usage Scenarios

Explosion-proof areas (non-explosion-proof structure, customized version required)

Offshore-Plattformen (additional anti-corrosion treatment needed)

Ultra-high voltage systems above 4.4kV (select 6kV version instead)

Equipment with frequent start-stop operations (mehr als 10 times per hour, special customized modules recommended)

5.3 Practical Cases

Fall 1: Induced Draft Fan Renovation in Thermal Power Plant

Original system: Fixed-speed motor + baffle adjustment, high energy consumption and severe baffle wear

Renovation solution: ACS 2040 Wechselrichter + 3 sets of 2UEA001345 phase modules (3-Phase)

Effect: Energy consumption reduced by 38%, annual electricity cost saved about 1.8 million RMB, baffle maintenance cycle extended 5 mal

Fall 2: High-pressure Water Supply System for Large Water Plant

Nachfrage: Constant pressure water supply with large load fluctuation (20%-100%)

Lösung: ACS 2040 Rahmen 1 (3 pcs 2UEA001345 modules) + PID control system

Effect: Stable pressure deviation within ±0.05MPa, 32% Energieeinsparung, service life extended by 3 Jahre

  1. Air Shipment Compliance & Certification Guide

6.1 Shipment Compliance Confirmation

ArtikelStatusErläuterung
Built-in Lithium BatteryNEINOnly electronic components and IGBT modules equipped
Dangerous Goods ClassificationNon-dangerous goodsCompliant with IATA DGR Class 9, no special shipping restrictions
Transport RestrictionsKeinerCan be shipped as ordinary industrial equipment
Packaging StandardStandard shockproof packageFix IGBT modules firmly to avoid damage during transit
Temperaturbereich-20℃ ~ +50℃Avoid extreme temperature during transportation

6.2 Certification Document Acquisition

CE Certificate: Available for download on official ABB website (Document ID: ACS2000-PHTC01U-EN)

UL Certificate: Apply via ABB global technical support center

Manufacturer Declaration: Including EMC, safety and RoHS compliance statements

  1. Auswahlrichtlinien & Quick Rules

Selection Rules

  1. Spannungsanpassung: 2UEA001345 for 4kV systems; choose 2UEA001348 for 6kV systems
  2. Aktuelle Auswahl: 1000A standard (PMK1000), 800A low current (PMK800), 1200Ein hoher Strom (PMK1200)
  3. Systemkompatibilität: Only applicable to ACS 2040 Serie (ACS2000 platform) Rahmen 1 Größe
  4. Quantity Matching: 3 phase modules required for one 3-phase inverter, 1 spare module is recommended
  5. Wartungstipps: Regularly inspect cooling fans, replace IGBT modules every 5 years to ensure stable insulation performance
  6. Main Accessories & Empfohlene Konfiguration
ZubehörnameModellFunktion
SteuereinheitACS 2040-CUCore control unit matched with phase modules
Cooling Fan3HAC031683-001Special cooling fan for phase modules, support redundant operation
Drive Board3HAC031684-001IGBT drive circuit with integrated protection functions
Voltage Sensor3HAC031685-0014kV system voltage monitoring, realize over/under voltage protection
Current Sensor3HAC031686-0011000A current detection, Überstrom & Kurzschlussschutz
Installation Kit3HAC031687-001Including fixing bolts, Dichtungen, insulating sleeves etc.

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen