Codebezeichnungen für Modell 440RB23020C - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Codebezeichnungen für Modell 440RB23020C - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

NachrichtHandelsnachrichten

Codebezeichnungen für Modell 440RB23020C

(Standard Format: 440R-B23020/C)

Kernbeschreibung

This is a safety monitoring relay from the Allen-Bradley (Rockwell Automation) Guardmaster Minotaur MSR5T Series, Series C version. It is intended for low-risk safety applications in industrial automation systems, such as safety gate monitoring and emergency stop button control.

1 Vollständige Modellaufschlüsselung

ModellsegmentStandard FormatBeschreibung
440R440RProduct family identifier for Rockwell Automation Bulletin 440R safety relays, part of the Guardmaster safety product range
B-BSubseries code, representing the MSR5T Series (Minotaur Safety Relay Type 5T monitoring safety relay)
2302023020Function and configuration code, wie folgt detailliert beschrieben:
– 2: Supply type (universal 24V AC/DC power supply)
– 3: Number of safety outputs (3 normally open NO safety outputs)
– 0: Auxiliary output type (1 normally closed NC auxiliary output)
– 2: Input configuration (1 normally closed NC single‑channel input, for safety gate interlocks and E‑stop buttons)
– 0: Reset type (selectable automatic / manual reset via jumper)
C/CSeries version code, indicating Series C, the latest production version with firmware updates and performance improvements

2 Detailed Explanation of Each Code

  1. 440R – Product Family Identifier

440: Standard prefix for Rockwell Automation safety products, dedicated to the Guardmaster safety relay line

R: Abbreviation for Relay, defining the product as a safety relay, distinguishing it from other 440-series devices such as safety switches (440G) and safety controllers (440C)

  1. B – Subseries Code (MSR5T)

B Corresponds exclusively to the Minotaur MSR5T model, a monitoring safety relay with key features:

Single-or dual-channel input (this model uses 1NC single-channel input)

3 independent redundant normally open safety outputs to ensure reliable safety function

1 normally closed auxiliary output for status feedback signals

Supports output monitoring to detect faults in the safety output circuit

  1. 23020 – Detailed Function Configuration Code
DigitBedeutungValue in This ModelSpezifikation
11. Ziffer (2)Supply type2Universal 24V AC/DC power supply, wide‑range design for various control systems
2nd. Ziffer (3)Number of safety outputs33 normalerweise offen (NEIN) safety outputs for direct control of contactors or actuators
3rd digit (0)Auxiliary output type01 normalerweise geschlossen (NC) auxiliary output for PLC status feedback or indicator control
4Ziffer (2)Input configuration21 normalerweise geschlossen (NC) single‑channel input for low‑risk applications
5Ziffer (0)Reset type0Selectable automatic / manual reset via jumper on terminals X1‑X2
  1. C – Series Version Code

C Indicates the product is Series C, the latest production version

Version differences:

Series A: Original version

Series B: Improved version with partial functional optimizations

Series C: Latest version with firmware updates, performance enhancements, and compatibility improvements

All series versions are fully functionally compatible and can be directly interchanged

3 Wichtige technische Parameter (for 440R-B23020/C)

ParameterSpezifikation
ProdukttypMinotaur MSR5T safety monitoring relay
Safety RatingKategorie 4, PLe (ISO 13849‑1), SIL 3 (IEC 61508), Stop Category 0
Input Configuration1 normalerweise geschlossen (NC) single‑channel input, suitable for safety gate interlocks and emergency stop buttons
Ausgabekonfiguration3 normalerweise offen (NEIN) safety outputs + 1 normalerweise geschlossen (NC) auxiliary output
Versorgungsspannung24V AC/DC (universal power supply)
Methode zurücksetzenAutomatisch / manueller Reset (selectable via jumper)
MontageDIN-Schienenmontage (IN 60715 konform), Breite 22.5 mm
SchutzgradIP20 (Front)
Betriebstemperatur-25 °C bis +60 °C

4 Application Areas & Auswahlrichtlinien

Typische Anwendungen

Safety gate monitoring (low-risk applications)

Emergency stop button control

Safety circuit monitoring for small machinery

Wichtige Auswahlpunkte

Confirm input type: ensure single-channel 1NC input meets safety device connection requirements

Check output quantity: verify 3 NO safety outputs + 1 NC auxiliary output satisfy control circuit demands

Verify supply compatibility: confirm 24V AC/DC universal power matches system voltage

Version selection: Series C is the latest version and recommended for priority use

 

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen