Micro-Epsilon eddyNCDT 3060 Wirbelstrom-Wegsensor
Official Model Code Definition
eddyNCDT 3060-ES-U1-010-S
- eddyNCDT: Standard product series code for Micro-Epsilon eddy current displacement sensors, differentiated from optoNCDT (laser triangulation) and capacNCDT (kapazitiv) Serie. It realizes non-contact high-precision displacement measurement based on eddy current principle.
- 3060: Produktseriencode, standing for standard measuring range series (≥1mm), distinguished from 3061 (small range series <1mm) Und 3070/3071 (high-performance enhanced series).
- ES: Sensor probe type code. E = standard type, S = short probe; optional types include L=long probe, T=high-temperature probe.
- U1: Measuring range code. U1=1mm range, U2=2mm, S1=3mm, S2=4mm, M1=6mm, M2=8mm, usw.
- 010: Cable length code, representing 10-meter standard cable; optional: 001=1m, 002=2m, 005=5m, 020=20m.
- S: Special function code. S=standard type, C=temperature compensated type, H=high-pressure type (max.700bar), EX=explosion-proof type.
- Technische Kernparameter (Offizieller Standard)
| Parameterkategorie | Spezifikationen | Bemerkungen |
| Grundparameter | ||
| Messprinzip | Eddy current induction principle | Non-contact measurement, applicable to conductive materials (ferromagnetic / non-ferromagnetic) |
| Betriebsspannung | 12~32 VDC | Standard industrial power supply, compatible with PLC/DCS systems |
| Stromverbrauch | 0.6 W | Geringer Stromverbrauch, suitable for long-term continuous operation |
| Ausgabetyp | Analog (0.5~9.5V / 4~20mA) + Digital (RS485/USB/Ethernet /EtherCAT/PROFINET) | Multiple interfaces available to match various control systems |
| Calibration Mode | 3-point calibration (3060 Serie) / 5-point calibration (3061 Serie) | Improve measuring accuracy, adapt to different target materials |
| Leistungsparameter | ||
| Messbereich | 1/2/3/4/6/8 mm | Standard range series; 3061 series offers 0.4mm ultra-small range |
| Auflösung | ≤0.01% F.S. (up to 0.02μm for 1mm range) | High-precision measurement for sophisticated industrial applications |
| Linearity | <±2.5μm (1mm range) / <±5μm (2mm range) | Ensure accurate measuring data |
| Frequency Response | 20 kHz (-3dB) | Capable of measuring high-speed dynamic displacement and vibration |
| Sampling Rate | 75 kSa/s (16bisschen) for analog output, 1 kSa/s (16bisschen) for digital interface | Fast data acquisition for dynamic measurement |
| Temperature Stability | Sensor: <0.25μm/K, Regler: <0.01% F.S./K | Maintain high precision under wide temperature conditions |
| Physical Parameters | ||
| Probe Material | Edelstahl (1.4404/316L) | Corrosion-resistant, ideal für industrielle Umgebungen |
| Measuring Surface Material | Ceramic / PTFE | Wear-resistant and well-insulated |
| Dimension | ES-U1: Φ8×22mm, ES-S1: Φ12×28mm | Compact structure for flexible installation |
| Schutzklasse | Probe: IP68/IP69K, Regler: IP67 | Staubdicht und wasserdicht, fit for harsh industrial sites |
| Betriebstemperatur | Probe: -40℃~+200℃, Regler: -20℃~+70℃ | Wide temperature range for high-temperature industrial scenarios |
| Pressure Resistance | Standardtyp:10Bar, High-pressure type: max.700bar | Applicable to hydraulic systems and other high-pressure environments |
| Gewicht | Probe: approx.30g, Regler: approx.200g | Lightweight design to reduce installation load |
- Anwendungsrichtlinien
Empfohlene Anwendungen (✅ Applicable)
- Precision Machinery Manufacturing: Radial/axial runout monitoring of machine tool spindles, positioning accuracy detection of ball screws, parallelism measurement of linear guides
- Automotive Industry: Vibration monitoring of engine crankshafts and camshafts, gear clearance measurement of gearboxes, end face runout detection of brake discs
- Leistung & Energy Industry: Shaft vibration monitoring of steam turbines and generators, amplitude measurement of fan blades, eccentricity detection of motor rotors
- Aerospace Industry: Vibration monitoring of aero-engine blades, structural deformation measurement of landing gears, gap detection of fuselage skin
- Metallurgische Industrie: Roll eccentricity measurement, strip steel tension control, mold oscillator vibration monitoring for continuous casters
- Semiconductor Manufacturing: Positioning accuracy detection of wafer transfer platforms, displacement measurement of lithography machine worktables, gap control for chip packaging
Unrecommended Scenarios (❌ Avoid)
- Measurement of non-conductive materials (plastic, wood, Glas): Eddy current principle only responds to conductive materials
- Umgebung mit starken elektromagnetischen Störungen (near high-frequency welders and large inverters): Shielded cables and filters are recommended
- Frequent replacement of target materials without recalibration: Will cause increased measuring errors
- Included angle over 5° between probe and target surface: Affect measuring accuracy; vertical installation is suggested
- Thick insulating coating on target surface (>0.1mm): Block eddy current penetration and lead to inaccurate measurement
- Humid environment without moisture-proof treatment: High protection level cannot prevent internal circuit damage from long-term immersion
- Cross-Brand Equivalent Replacement List
| Originalmodell | Alternative Marke | Ersatzmodell | Kompatibilitätshinweise |
| Micro-Epsilon eddyNCDT 3060-ES-U1-010-S | KEYENCE | GT2-P12K | Same 1mm range, Analoger Ausgang, 10kHz response frequency (slightly lower) |
| OMRON | ZX2-LD100 | 1mm range, PNP-Ausgang, ±5μm linearity (slightly inferior) | |
| KEYENCE | GT2-P12 | 1mm range, digital output, 50kSa/s sampling rate (slightly lower) | |
| RENISHAW | XL-80 | Laser interferometer alternative, higher accuracy with higher cost | |
| Panasonic | HG-C1030 | 1mm range, Analoger Ausgang, 5kHz response frequency (low) | |
| KRANK | OD2-N120W | 1mm range, Analoger Ausgang, ±3μm linearity |
- Complete eddyNCDT 3060 Series Order Codes (Latest Official Version)
| Bestell-Nr. | Vollständiges Modell | Merkmale | Anwendung |
| eddyNCDT 3060-ES-U1-010-S | Standardtyp, 1mm range, 10m cable | General industrial precision displacement measurement | Werkzeugmaschinen, automatische Produktionslinien |
| eddyNCDT 3060-ES-U2-010-S | Standardtyp, 2mm range, 10m cable | Medium-range measurement | Automotive parts inspection |
| eddyNCDT 3060-ES-S1-010-S | Standardtyp, 3mm range, 10m cable | Medium-large range measurement | Metallurgical equipment monitoring |
| eddyNCDT 3060-ES-S2-010-S | Standardtyp, 4mm range, 10m cable | Large-stroke measurement | Logistics conveying equipment |
| eddyNCDT 3060-ES-M1-010-S | Standardtyp, 6mm range, 10m cable | Extra-large stroke measurement | Aerospace structural inspection |
| eddyNCDT 3060-ES-M2-010-S | Standardtyp, 8mm range, 10m cable | Maximum range measurement | Large machinery vibration monitoring |
| eddyNCDT 3060-ES-U1-010-T | High-temperature type, 1mm range, 10m cable | Betriebstemperatur: -40℃~+200℃ | Engine and high-temperature metallurgical environments |
| eddyNCDT 3060-ES-U1-010-H | High-pressure type, 1mm range, 10m cable | Max pressure resistance:700Bar | Hydraulic systems, high-pressure containers |
| eddyNCDT 3060-ES-U1-010-EX | Explosion-proof type, 1mm range, 10m cable | Compliant with ATEX/IECEx standards | Flammable & explosive environments such as chemical and petroleum industry |
Common Fault Diagnosis & Maintenance Solutions (Official Recommended
| Fehlerphänomen | Mögliche Ursachen | Schritte zur Fehlerbehebung | Maintenance Solutions |
| Measured Value Drift | 1. Severe temperature change | 1. Check if ambient temperature is within working range | 1. Install heat shield or select high-temperature model |
| 2. Mismatch between probe and target material | 2. Confirm target material is consistent with calibrated material | 2. Recalibrate for current material | |
| 3. Loose cable connection | 3. Fasten M12 connector | 3. Reconnect and lock connectors | |
| 4. Uncalibrated controller | 4. Re-perform 3-point calibration | 4. Execute calibration via web interface | |
| Severe Signal Noise | 1. Elektromagnetische Störungen | 1. Check nearby inverters and motors | 1. Install filters or use shielded cables |
| 2. Power supply voltage fluctuation | 2. Control voltage fluctuation within ±10% | 2. Equip regulated power supply | |
| 3. Non-parallel installation between probe and target | 3. Keep included angle below 5° | 3. Adjust installation angle | |
| 4. Oil stain / oxide layer on target surface | 4. Clean target surface | 4. Remove surface dirt | |
| No Signal Output | 1. Ungewöhnliche Stromversorgung | 1. Verify input voltage 12~32V | 1. Repair power circuit |
| 2. Falsche Verkabelung | 2. Check wiring definition: Red=+, Black=-, Green=signal | 2. Wire strictly in accordance with manual | |
| 3. Damaged probe | 3. Test sensing face with metal object | 3. Replace matched probe | |
| 4. Controller failure | 4. Check controller indicator status | 4. Contact Micro-Epsilon after-sales service | |
| Reduced Measuring Accuracy | 1. Linearity deviation | 1. Inspect linearity deviation range | 1. Perform recalibration |
| 2. Insufficient resolution | 2. Confirm proper range selection | 2. Choose larger-range model | |
| 3. Inadequate frequency response | 3. Adjust frequency response parameters | 3. Optimize response parameters | |
| 4. Loose installation | 4. Tighten mounting threads | 4. Fasten sensor firmly | |
| Overheated Probe | 1. Zu hohe Umgebungstemperatur | 1. Control ambient temperature ≤+200℃ | 1. Add heat dissipation measures |
| 2. Internal circuit fault | 2. Confirm current consumption ≤50mA | 2. Apply for professional after-sales maintenance | |
| 3. Long-term high-load operation | 3. Check uniform heating status | 3. Lower sampling rate or set intermittent operation |
Typische Anwendungsfälle
Fall 1 Automotive Engine Manufacturing: Crankshaft Axial Runout Monitoring System
Customer Profile
An automotive engine manufacturer with annual output of 1 million 4-cylinder engines needs accurate crankshaft axial runout detection on production lines to ensure assembly precision and engine performance.
Core Challenges
- 42CrMo alloy steel crankshaft with surface lubricating oil easily causes unstable detection
- Production line speed: 60 pieces per hour, measuring cycle required within 10 Sekunden
- Working site filled with cutting fluid and metal dust, high protection demand
- Measuring accuracy required: ±1μm to meet standard axial clearance
Lösungen
Deploy 2 sets of eddyNCDT 3060-ES-U1-010-S sensors installed at both ends of crankshaft
Adopt vertical installation with 0.5mm initial distance from crankshaft end face
Match Micro-Epsilon DT3060 controller, connect to PLC system via EtherCAT protocol
Equip 5μm precision filter to prevent cutting fluid and dust intrusion
Application Effects
- Crankshaft axial runout measuring accuracy reaches ±0.8μm, qualified assembly rate rises from 98.2% Zu 99.9%
- 360-day trouble-free continuous operation, maintenance frequency reduced by 90%
- Excellent resistance against cutting fluid and dust, IP68 protection ensures stable operation
- Annual production cost saved about 5 million RMB
Fall 2 Wind Power Industry: Wind Turbine Main Shaft Vibration Monitoring System
Customer Profile
A wind power equipment manufacturer producing 500 sets of 2MW wind turbine units annually needs real-time main shaft vibration monitoring to guarantee operational safety.
Core Challenges
- Q345 steel main shaft with 1.2m diameter requires 4mm measuring range
- Operating vibration frequency up to 10kHz, sensor frequency response ≥20kHz required
- Dramatic ambient temperature change (-30℃~+60℃) demands excellent temperature stability
- 24-hour uninterrupted monitoring with ultra-high reliability requirement
Lösungen
Installieren 4 sets of eddyNCDT 3060-ES-S2-020-S sensors in 90° layout on front and rear bearing seats
Keep 2mm initial distance between sensor and shaft surface for non-contact measurement
Connect controller to SCADA system via PROFINET for real-time vibration data monitoring
Equip heating device for stable operation under low temperature
Application Effects
- Main shaft vibration measuring accuracy reaches ±2μm, early fault warning accuracy up to 95%
- Stable operation within -30℃~+60℃ with temperature drift less than 0.5μm
- 500-day failure-free system operation, turbine maintenance cycle extended from 3 months to 1 Jahr
- Annual wind turbine shutdown loss reduced by about 8 million RMB
- Zertifizierung & Air Freight Information
- Zertifizierungen
CE: Compliant with EU industrial electrical safety standard EN 61010-1
UL: Meet North American industrial equipment safety requirements
RoHS: Lead-free eco-friendly design complying with EU environmental directives
EMV: Conform to EN 55011 Class B electromagnetic compatibility standard with strong anti-interference performance
ATEX/IECEx: Explosion-proof models meet explosion-proof safety standards
- Luftfracht-Compliance
No built-in lithium batteries, supercapacitors or hazardous substances
Classified as ordinary industrial electrical equipment, no special documents required for air and sea transportation
Package meets ISTA 2A standard for direct international delivery
- Herkunft: Made in Germany, original imported with reliable quality

Micro-Epsilon eddyNCDT 3060 Wirbelstrom-Wegsensor
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien