M1M: ABB M1M Series Motor Protection and Management Unit (Motor Protection Controller)
2TAZ664052R0007: Corresponding ABB original order number / material code
- Produkttyp
Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control.
- Kernfunktionen
Überlast, locked-rotor, and underload protection
Phase sequence, Phasenverlust, and phase imbalance protection
Earth fault / earth leakage protection
Motor operating status monitoring and fault output
- Same Series & Alternative Modelle
Same series: Full ABB M1M series (M1M 01/02/03 and other current ratings)
Verbesserte Alternativen: ABB M102 / M2M series (functionally compatible with enhanced performance)
Cross-brand alternatives: Siemens 3RB series, Schneider EOCR series motor protection relays
- Typische Anwendungen
Protection for three-phase asynchronous motors such as industrial fans, Wasserpumpen, Förderer, und Kompressoren, as well as automated production lines and factory low-voltage power distribution systems.
ABB M1M Series Digital Multifunction Power Meters
- Modellbedeutung & Produktpositionierung
Modellaufschlüsselung
M1M: ABB System pro M Series Digital Multifunction Power Meters (not motor protectors; please distinguish carefully)
Suffix numbers: Product function level (10/12/15/20/30); higher numbers indicate richer functions
Complete model example: M1M-2TAZ664052R0007 (2TAZ664052R0007 is the ABB original order number / material code)
Produktpositionierung
ABB’s new-generation modular DIN-rail mounted multifunction power monitoring meters, used for energy metering, power quality analysis, and electrical parameter monitoring in mediumand low-voltage primary and secondary distribution systems. Supports Modbus communication and is suitable for industrial and building applications.
- Full Series Comparison
| Modell | Kernfunktionen | Kommunikationsschnittstelle | I/O | Supply Voltage | Sample Order No. |
| M1M 10 | Basic energy measurement, no display | None | None | No auxiliary power required | 2TAZ661010R2000 |
| M1M 12 | Basic energy measurement, LED indication | None | None | No auxiliary power required | 2TAZ661210R2000 |
| M1M 15 | Multifunction measurement, LCD-Display | Optionaler Modbus | None | 100–230V AC/DC | 2TAZ661510R2000 |
| M1M 20 | Multifunction measurement, LCD-Display | Optionaler Modbus | None | 100–230V AC/DC | 2TAZ662010R2000 |
| M1M 30 | Advanced measurement, power quality analysis | Optional Modbus/Ethernet | Optional 2DI/2DO | 100–230V AC/DC | 2TAZ663010R2000 |
| M1M 30 I/O | Advanced measurement + I/O control | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 |
| M1M 30 Ethernet | Advanced measurement + Ethernet | Modbus TCP/IP | None | 100–230V AC/DC | 2TAZ663011R2001 |
- Technische Spezifikationen (M1M 30 Serie)
Measurement accuracy: Current/voltage class 0.2, active energy class 0.5S (konform mit IEC 62053-22), reactive energy class 2
Measured parameters: Three-phase voltage/current, Wirk-/Blind-/Scheinleistung, Leistungsfaktor, Frequenz, energy metering (forward/reverse), harmonische Analyse (selected models)
CT input: Standard 1A/5A, supports star (3E) oder Delta (2E) Verbindung
Ingress protection: IP51 (front panel), IP20 (Terminals)
Montage: 35mm DIN-Schiene, 18mm Breite (1 Modul)
- Kernanwendungsszenarien
- Sub-metering in commercial buildings (Beleuchtung, HVAC, power circuits)
- Power distribution system monitoring and energy efficiency analysis in industrial plants
- Power quality monitoring in data centers
- Real-time electrical parameter monitoring in low-voltage distribution cabinets
- Power generation metering for renewable energy systems (PV / Windkraft)
- Alternative Modelle & Brand Comparison
Upgraded Alternatives (Same Brand)
Function expansion: ABB M2M series (higher accuracy, more communication protocols)
Basisversion: ABB M1M 10/12 (basic energy metering, geringere Kosten)
Cross-Brand Alternatives
| Marke | Empfohlener Ersatz | Compatibility Notes |
| Schneider | PowerLogic PM5000 series | Similar functions, compatible communication protocols |
| Siemens | SENTRON PAC series | Comparable measurement accuracy, supports Modbus |
| Domestic alternatives | Acrel PZ series, Chint DTSU series | Cost advantage, compatible basic functions |
- Selection Guidelines
- Measurement needs: Basic energy metering → M1M 10/12; real-time monitoring → M1M 15/20; power quality analysis → M1M 30
- Communication needs: Remote monitoring → models with Modbus (M1M 15/20/30)
- Control needs: Digital input/output required → M1M 30 I/O
- Installation environment: Ensure operating temperature range (-25°C to +55°C) and protection class requirements
Complete List of ABB Multifunction Power Meters
This list covers ABB’s mainstream multifunction power meter series, sorted from basic metering to advanced power quality analysis by product positioning. Includes model numbers, core functions, technische Parameter, order numbers, and application scenarios for easy selection and procurement reference.
- M1M Series (System pro M, Modular DIN-Rail Mounted)
ABB’s new-generation compact multifunction power meters for mediumand low-voltage primary and secondary distribution systems. Nur 18 mm breit (1 Modul) and supports hot-swap.
I.1 Basic Metering Type (Keine Anzeige / LED Indication)
| Modell | Kernfunktionen | Genauigkeitsklasse | Kommunikation | I/O | Stromversorgung | Sample Order No. | Anwendung |
| M1M 10 | Three‑phase energy measurement (no display) | Active 0.5S, Reactive 2 | None | None | No auxiliary power | 2TAZ661010R2000 | Basic energy statistics, low‑cost applications |
| M1M 12 | Three‑phase energy measurement (LED status indication) | Active 0.5S, Reactive 2 | None | None | No auxiliary power | 2TAZ661210R2000 | Simple circuit monitoring, fault indication |
I.2 Multifunction Display Type (LCD Display)
| Modell | Kernfunktionen | Genauigkeitsklasse | Kommunikation | I/O | Stromversorgung | Sample Order No. | Anwendung |
| M1M 15 | Three‑phase full‑electrical measurement, LCD-Display | Active 0.5S, Reactive 2 | Optional Modbus RTU | None | 100–230V AC/DC | 2TAZ661512R2000 | Sub‑metering in commercial buildings, industrial monitoring |
| 10239994 | |||||||
| M1M 15 I/O | Full‑electrical measurement + 2DI/2DO | Active 0.5S, Reactive 2 | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ661512R2001 | Local alarm/control, equipment interlock |
| M1M 20 | Full‑electrical + THD measurement, LCD-Display | Active 0.2S, Reactive 2 | Optional Modbus RTU | None | 100–230V AC/DC | 2TAZ662012R2000 | Industrial energy efficiency analysis, power quality monitoring |
| 10239996 | |||||||
| M1M 20 I/O | Full‑electrical + THD + 2DI/2DO | Active 0.2S, Reactive 2 | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ662012R2001 | Local control, Alarmausgang |
| M1M 20 Ethernet | Full‑electrical + THD + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | None | 100–230V AC/DC | 2TAZ662014R2000 | Network integration, Fernüberwachung |
I.3 Advanced Power Quality Type
| Modell | Kernfunktionen | Genauigkeitsklasse | Kommunikation | I/O | Stromversorgung | Sample Order No. | Anwendung |
| M1M 30 | Full‑electrical + harmonische Analyse (up to 40th), data logging | Active 0.2S, Reactive 2 | Optional Modbus RTU | None | 100–230V AC/DC | 2TAZ663012R2000 | Analyse der Netzqualität, energy optimization |
| 10239997 | |||||||
| M1M 30 I/O | Volle Funktionen + 2DI/2DO | Active 0.2S, Reactive 2 | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 | Local control + alarm, equipment interlock |
| M1M 30 Ethernet | Volle Funktionen + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | None | 100–230V AC/DC | 2TAZ663014R2000 | Remote power quality monitoring, system integration |
| M1M 30 I/O Ethernet | Volle Funktionen + 2DI/2DO + Ethernet | Active 0.2S, Reactive 2 | Modbus RTU/TCP | 2DI/2DO | 100–230V AC/DC | 2TAZ663014R2001 | Smart power distribution systems, energy management |
Special model: M1M-2TAZ664052R0007 (custom version of M1M series, order no. 2TAZ664052R0007), functions equivalent to M1M 30, for specific project requirements.
- M2M Series (System pro M compact, Panel Mounted)
ABB mid-range power quality analyzers, 96mm wide (4 Module), suitable for mounting on distribution cabinet doors. Fully functional with advanced power quality analysis.
| Modell | Kernfunktionen | Genauigkeitsklasse | Kommunikation | I/O | Harmonische Analyse | Data Logging | Sample Order No. | Anwendung |
| M2M 10 | Full‑electrical measurement, LCD-Display | Active 0.2S, Reactive 2 | Modbus RTU | 2DI/2DO | Up to 31st | Basic logging | 2CSG299883R4052 | Industrial power monitoring, energy efficiency analysis |
| M2M 20 | Analyse der Netzqualität, event recording | Active 0.1S, Reactive 2 | Modbus RTU/TCP | 4DI/4DO | Up to 40th | Advanced logging | 2CSG299884R4052 | Critical load monitoring, fault diagnosis |
| M2M 30 | Advanced power quality, PQDIF export | Active 0.05S, Reactive 2 | Modbus RTU/TCP | 8DI/8DO | Up to 63rd | Comprehensive logging | 2CSG299885R4052 | Rechenzentren, critical production equipment |
| Ethernet/IP |
III. M4M Series (Network Analyzers)
ABB high-end power quality analyzers, standalone installation, for mediumand high-voltage distribution systems, providing complete power quality analysis and energy management.
| Modell | Kernfunktionen | Genauigkeitsklasse | Kommunikation | I/O | Harmonische Analyse | Data Logging | Anwendung |
| M4M 100 | Full parameter measurement, power quality analysis | Active 0.02S, Reactive 1 | Modbus RTU/TCP | 16DI/16DO | Up to 63rd | Large‑capacity storage | Medium‑/high‑voltage distribution, grid monitoring |
| DNP3 | |||||||
| M4M 200 | Advanced power quality, power quality reporting | Active 0.01S, Reactive 1 | Modbus RTU/TCP | 24DI/24DO | Up to 127th | Massive storage | Grid custody metering, power trading |
| DNP3 | |||||||
| IEC 61850 |
- D1M Series (System pro M Distributed Monitoring)
ABB distributed power monitoring system supporting centralized monitoring of multiple circuits, ideal for large buildings and industrial plants, with remote management via gateways.
| Modell | Kernfunktionen | Monitored Circuits | Kommunikation | I/O | Stromversorgung | Anwendung |
| D1M 10 | Centralized monitoring of 4 Schaltkreise | 4×three‑phase | Modbus RTU | 8DI/4DO | 24In DC | Gewerbebauten, multi‑story plants |
| D1M 20 | Centralized monitoring of 8 Schaltkreise | 8×three‑phase | Modbus RTU/TCP | 16DI/8DO | 24In DC | Large shopping malls, industrial parks |
- EM Series (Smart Power Meters)
ABB economical multifunction power meters for small buildings and industrial applications, cost-effective and flexible installation.
| Modell | Kernfunktionen | Genauigkeitsklasse | Kommunikation | I/O | Stromversorgung | Anwendung |
| EM 20 | Single‑phase current/voltage measurement | Active 1, Reactive 2 | None | None | No auxiliary power | Residential, small shops |
| EM 100 | Single‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optionaler Modbus | 2DI/2DO | 100–230V AC/DC | Small commercial, lighting circuits |
| EM 200 | Three‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optionaler Modbus | 4DI/4DO | 100–230V AC/DC | Small factories, office buildings |
| EM 400 | Three‑phase full‑electrical + analog output | Active 0.2S, Reactive 2 | Optionaler Modbus | 4DI/4DO | 100–230V AC/DC | Process control, equipment interlock |
| 2AO |
- Other Series (Spezielle Anwendungen)
| Serie | Modell | Kernfunktionen | Anwendungsszenarien |
| IM Series | IM302 | Smart power monitoring, event recording | Industrielle Automatisierung, equipment monitoring |
| LNP3 Series | LNP301 | Energy metering, remote meter reading | Public utilities, smart grids |
| PMU Series | PMU6000 | Multifunction measurement, power quality analysis | Large‑scale industry, energy management |
VII. Auswahlhilfe (By Application)
- Basic energy metering: Choose M1M 10/12 or EM 20/100, niedrige Kosten, meets basic statistical needs
- General power monitoring: Choose M1M 15/20 or M2M 10, volle funktionen, supports Modbus communication
- Analyse der Netzqualität: Choose M1M 30 or M2M 20/30, harmonic analysis up to 40th/63rd, supports event recording
- Medium-/high-voltage distribution: Choose M4M series, high-accuracy measurement, complete power quality analysis, supports IEC 61850
- Multi-circuit centralized monitoring: Choose D1M series, distributed architecture, reduces wiring and costs-
VIII. Core Technical Parameter Comparison
| Serie | Messgenauigkeit | Harmonische Analyse | Kommunikationsprotokolle | I/O Capacity | Montage | Breite |
|---|---|---|---|---|---|---|
| M1M | 0.5S ~ 0.2S | Up to 40th | Modbus RTU/TCP | 0~2DI/2DO | DIN rail | 18mm |
| M2M | 0.2S ~ 0.05S | Up to 63rd | Modbus RTU/TCP Ethernet/IP | 2~8DI/DO | Panel mount | 96mm |
| M4M | 0.02S ~ 0.01S | Up to 127th | Modbus RTU/TCP DNP3 IEC 61850 | 16~24DI/DO | Standalone / 19″ rack | 19″ |
| D1M | 0.5S | Up to 31st | Modbus RTU/TCP | 8~16DI/DO | DIN rail | 72mm |
| EM | 0.5S ~ Class 1 | Up to 15th | Optionaler Modbus | 0~4DI/DO | DIN rail | 36mm |
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien


















NH42-63-318x560.png)




