Allen-Bradley 440R-N23114 Safety Relay

Basic Model Definition Catalog Number: 440R-N23114 Internal Model Code: MSR126.1T Brand: Allen-Bradley (Rockwell Automation), Guardmaster Minotaur Series Lifecycle: Active production model, manufactured in Czech Republic, standard 1-year warranty Core Electrical Specifications 2.1 Power Supply Rated Voltage: 24V AC/DC, operating range: 0.85~1.1× rated voltage (20.4~26,4V) Stromverbrauch: 4W, compatible with 50/60Hz Terminals A1/A2: Power input 2.2 ...

  • Produktdetails

Basic Model Definition

Catalog Number: 440R-N23114

Internal Model Code: MSR126.1T

Marke: Allen-Bradley (Rockwell Automation), Guardmaster Minotaur Series

Lebenszyklus: Active production model, manufactured in Czech Republic, standard 1-year warranty

  1. Grundlegende elektrische Spezifikationen

2.1 Stromversorgung

Nennspannung: 24V AC/DC, operating range: 0.85~1.1× rated voltage (20.4~26,4V)

Stromverbrauch: 4W, kompatibel mit 50/60Hz

Terminals A1/A2: Power input

2.2 Safety Inputs (Dual-channel 4-wire with cross short-circuit detection)

2 normalerweise geschlossen (NC) safety input paths (S11-S12 / S21-S22)

Supports dual-channel emergency stop, safety door switches and safety light curtains; built-in cross-channel short-circuit fault diagnosis

Maximum input loop resistance: ≤90Ω

2.3 Schaltkreis zurücksetzen (S33-S34)

MSR126.1T supports automatic reset and manual reset dual modes

  1. Automatischer Reset: Short S33 and S34; outputs close automatically after faults are cleared
  2. Manueller Reset: Connect an external normally open reset pushbutton to S33-S34; manual push is required to restore outputs

Difference from MSR126.1R: MSR126.1R only provides monitored manual reset without automatic reset function

2.4 Safety Output Contacts (Force-guided safety contacts complying with IEC 61810-3)

2 safety normally open (NEIN) Kontakte: 13-14, 23-24

Load Ratings:

DC-13: 6A/24V DC; 3A/24V DC (for frequent switching)

AC-15: 5A/250V AC

Ansprechzeit: Ca. 15MS; Recovery Time: 100MS

No auxiliary alarm contacts

  1. Safety Certification Ratings (Top Industry Standards)

ISO 13849-1: Kategorie 4 / PL e

IEC 61508 / IEC 61511: SIL 3

IN 954-1: Safety Category 4, Kategorie 0 Stoppen

Zertifizierungen: CE, cULus, CCC, BG, C-Tick

  1. Mechanische Abmessungen & Montage

Breite: 22.5mm (compact DIN rail mounting)

Gesamtdimension: 110mm (H) × 75 mm (D) × 22.5mm (W)

Gewicht: 160G

Terminals: Fixed screw terminals (non-pluggable), Schutzart IP20

Betriebstemperatur: -25℃ ~ +70℃

  1. Front Panel LED Indicator Meanings
  2. PWR (Grün): Steady on when power supply is normal
  3. CH1 (Grün): Illuminated when Channel 1 input circuit is closed
  4. CH2 (Grün): Illuminated when Channel 2 input circuit is closed

All three LEDs on → Safety output contacts closed; Any single channel open → Outputs cut off

  1. Typische Anwendungsszenarien
  2. Dual-channel emergency stop button circuit monitoring
  3. 4-wire safety door switches (with short-circuit detection)
  4. Sicherheitslichtvorhang / light screen safety circuits
  5. Safety cut-off for machine tools, automated production lines and packaging equipment

Suitable for equipment requiring high safety ratings of PL e / SIL3

  1. Series Model Comparison for Selection
Catalog No.Internal CodeReset-ModusStromversorgungKanalkonfiguration
440R‑N23114MSR126.1TSelectable Auto/Manual Reset24V AC/DCDual-channel 4-wire
440R‑N23113MSR126.1RMonitored Manual Reset Only24V AC/DCDual-channel 4-wire
440R‑N23112MSR126TAuto/Manual Reset230V undDual-channel 4-wire
  1. Brief Wiring Logic
  2. Connect 24V AC/DC power to terminals A1/A2
  3. Wire two NC safety switches (Not-Aus / door switches) in series to S11-S12 and S21-S22 respectively
  4. Short-circuit S33-S34 for automatic reset; connect an NO pushbutton in series for manual reset
  5. Wire the safety coil of main contactors in series across terminals 13-14 Und 23-24
  6. Disconnection of any safety input or cross-channel short-circuit will simultaneously open both NO outputs to cut power supply
  7. Troubleshooting Guidelines
  8. PWR LED off: Power phase loss, insufficient voltage or loose wiring
  9. Single CH1/CH2 LED off: Corresponding channel switch open or circuit wire breakage
  10. Both CH1 and CH2 LEDs lit but outputs fail to close: Cross-channel short-circuit fault; power cycle to reset, or reset circuit not shorted / reset button not pressed
  11. Kontaktschweißen: Übermäßige Ausgangslast; replace contactors with higher capacity

Full Specifications of Safety Output Contacts for Allen-Bradley 440R-N23114

  1. Basic Contact Structure
  2. Menge & Typ: 2 independent redundant safety normally open (NEIN) contacts at terminals 13-14 Und 23-24; no auxiliary alarm contacts or delayed outputs
  3. Contact Construction: Force-guided safety contacts (IEC 61810-3), dual-channel redundant mechanical interlock. Single contact welding cannot maintain circuit conduction, fulfilling Category 4 / PL e / SIL3 safety architecture
  4. Kontaktmaterial: AgSnO₂ silver tin oxide, lichtbogenbeständig und schweißhemmend
  5. Minimum Conducting Current: 10mA (ensures reliable circuit detection by contacts)
  6. Rated Load Currents (Official Standard Load Categories)

2.1 AC Load (AC-15, standard load for electromagnetic contactors)

250V und: 6A (inductive-resistive load, cosφ=0.35)

UL B300 certified rating: 5A / 250V und

2.2 DC Load (DC-13, Magnetventile / DC coils)

Frequent switching at 24V DC: 3A (standard switching rating)

Low-frequency light load (0.1Hz) at 24V DC: Max. 6A for short-term use (long-term high-frequency operation not recommended)

2.3 Continuous Thermal Current Ith (static carrying current without switching)

Maximum static continuous current per single contact: 6A (only for permanent conduction with rare break operations)

  1. Elektrische Ausdauer & Operating Timing
  2. Elektrische Ausdauer (220V und / 4A / cosφ=0.35)

6A breaking capacity: 100,000 Operationen

4A light load: 500,000 Operationen

  1. Safety Operation Timing

Response time from safety input open to contact break: ≤15ms

Contact pull-in recovery time after fault clearance: Ca. 100MS

  1. Dielektrische Spannungsfestigkeit

Withstand voltage across open contacts: AC750V for 1 Minute

Isolationswiderstand (DC500V test): ≥1000MΩ

  1. External Protection & Wiring Limitations
  2. Recommended Fuse for Output Circuit

Slow-blow fuse: 6A; Fast-acting fuse: 10A. Over-rated fuses are prohibited to prevent contact ablation and welding

  1. Applicable Wire Gauge: 0.2~2.5mm² solid / stranded copper wires; fixed non-pluggable screw terminals
  2. Maximum Operating Voltage: 250V und / 30In DC; overvoltage is strictly forbidden
  3. Contact Performance Matching Safety Ratings

ISO 13849-1: Kategorie 4, PL e (independent cut-off via dual redundant contacts)

IEC 61508: SIL3; single contact failure will not disable safety cut-off function

Stop Category: IN 60204-1 Kategorie 0 hard cut-off stop

  1. Quick Load Selection Table
LasttypStromspannungNennstromAnwendungsszenarien
AC-15250V und6AAC contactor coils
DC-1324In DC3ADC solenoid valves, DC contactors
Static Continuous≤250VAC / 30VDC6ACircuits with permanent conduction and minimal breaking operations

tic Continuous | ≤250VAC / 30VDC | 6A | Circuits with permanent conduction and minimal breaking operations |