CX-75A belongs to the CX Turbo Medium-pressure Centrifugal Blower, allgemein bekannt als Mitteldruck-Turbogebläse. Zu den beliebten Marken gehört Eurostandard, Vollwind, MANVAC, usw. Es handelt sich um ein direkt gekoppeltes Industriegebläse aus Aluminiumlegierung mit einer Nennleistung von 0,75 kW (1PS).
✅ Key Specifications (50Hz Standard)
Nennleistung: 0.75 kW / 750W (1PS)
Stromversorgung: Einphasig 220V / Three-phase 380V optional
Luftstrom: 13 m³/min (780 m³/h); bis zu 15 m³/min at 60Hz
Max Positive Pressure: 2.4 kPa (2400 mmH₂O)
Max Negative Pressure: 1.7 kPa (1700 mmH₂O)
Einlass & Auslass: Inlet 125mm, Outlet 100mm
Material: Die-cast aluminum alloy housing + aluminum impeller, Direktantrieb, no belt
Schutzklasse: IP54/IP55, Isolierung der Klasse F
Geräuschpegel: 64~80dB(A)
Nettogewicht: Ca. 14~17kg (varies slightly by manufacturer)
✅ Structural Features
- Turbo structure, medium pressure with large air volume, different from high-pressure ring blowers.
- Motor and impeller are coaxial direct-coupled, kompakte Größe, belt-free maintenance.
- Full die-cast aluminum, lightweight with good heat dissipation; suitable for long continuous operation.
- Sealed maintenance-free bearings, low maintenance under normal working conditions.
✅ Typische Anwendungen
Combustion fan for burners, hot air drying, hot air circulation in ovens
Short-distance pneumatic conveying of powder/granules, dust extraction, dust collector equipment
Air blowing for printing, laminating, film blowing and coating machines
Equipment cooling, Luftzufuhr, air transportation, environmental ventilation, woodworking dust collection
✅ Selection & Supporting Points
Search Keywords: CX-75A, Turbo Medium-pressure Blower, 0.75kW Medium Pressure Fan
Optionales Zubehör: Air filter, silencer, regulating damper, hose connector, shock-absorbing foot pads
Installation: Flexible connectors recommended at inlet and outlet to reduce vibration transmission. An air filter must be installed at the inlet to prevent dust from damaging the aluminum impeller.
✅ Häufige Fehlerbehebung
- Reduced air flow: Clogged inlet filter, air leakage in piping, dust accumulation on impeller
- Overheat tripping: Overloaded pressure, instabile Spannung, blocked heat dissipation passage
- Ungewöhnliches Geräusch: Lager verschlissen, impeller rubbing casing, foreign objects entering the chamber
- Übermäßige Vibration: No shock absorption at base, unbalanced impeller, rigid pipe connection
✅ Comparison within the Same Series (For Alternative Selection)
CX-75SA (0.4kW) < CX-75A (0.75kW) < CX-100A (1.5kW) < CX-125A (2.2kW)
CX-75A (0.75kW Turbo Medium-pressure Blower) Anwendungsfälle
Kernvorteile: Medium pressure and large air volume, direct-coupled maintenance-free design. Suitable for blowing/suction applications with pipeline resistance, different from high-pressure ring blowers. Ideal für kleine & medium equipment and 24-hour continuous operation.
🔥 Case 1: Air Supply for Burners / Small Industrial Furnaces (Klassische Anwendung)
Arbeitszustand: Biomass burners, diesel burners, small incinerators, hot air furnaces for combustion air makeup.
Lösung: CX-75A delivers stable medium-pressure air to overcome resistance from burner nozzles and filters, ensuring stable oxygen ratio. Three-phase 380V model for continuous operation.
Zubehör: Inlet air filter, manual air damper for flow adjustment; use heat-insulated model CX-75AH for high-temperature working conditions to isolate radiant heat from furnace.
Kernpunkt: Stable air pressure prevents flame-out; many domestic small burners adopt this model as OEM standard.
🧹 Case 2: Dust Collection for Woodworking / Stone Processing
Arbeitszustand: Single-station dust extraction for small CNC wood routers, Schleifmaschinen, stone grinders with dust collection box.
Lösung: The blower creates negative pressure to extract wood chips and quartz dust; air flow of 13m³/min supports single-station dust piping.
Notiz: Install cartridge / primary filter at inlet to avoid aluminum impeller abrasion by dust. Minimize 90° elbows in piping to reduce resistance.
🧾 Case 3: Air Knife Drying for Printing, Laminating & Film Blowing Equipment
Arbeitszustand: Self-adhesive label printers, coating machines, Filmgebläse, Etikettendruck, blow off moisture on paper/film surface and assist static elimination.
Lösung: CX-75A supplies continuous medium-pressure airflow to air knives to blow off ink moisture, accelerate drying and avoid adhesion.
Besonderheit: Moderate air pressure, will not deform thin paper or film; stable air flow for continuous roll production.
🧪 Case 4: Blow-off for PCB / Glass Washing Lines (Electronics Industry)
Arbeitszustand: Blow residual water after ultrasonic cleaning of PCB etching lines and flat glass.
Lösung: Air is fed to air knives to remove water droplets from workpiece surface, lower cost compared with high-pressure air compressors.
Auswahltipp: Für feuchte Umgebungen, adopt moisture-proof motor treatment and install mist filter at air inlet.
🥣 Case 5: Food Machinery · Short-distance Pneumatic Conveying of Powder & Granules
Arbeitszustand: Grain sorting, sugar powder, starch, plastic pellets short-distance conveying (5~10m pipeline), small centralized feeding machine.
Lösung: Positive pressure pushes granular material to overcome resistance from pipe elbows; stainless steel impeller available for food-grade requirements.
Einschränkung: Only for short-distance and low-concentration conveying; upgrade to CX-100A for long-distance and high powder loading.
💧 Case 6: Aeration for Wastewater Treatment / Aquaculture
Arbeitszustand: Aeration for small biochemical tanks, aquaculture nursery ponds, liquid agitation in electroplating tanks.
Lösung: The blower delivers air to microporous aeration discs for water oxygenation; medium pressure overcomes water depth and pipeline resistance.
Tipp: Prioritize three-phase IP55 model in humid environments; air inlet filter prevents catkins and debris from blocking aeration discs.
🌡️ Case 7: Hot Air Circulation for Ovens & Constant Temperature Chambers
Arbeitszustand: Hot air circulation in small industrial ovens, drying cabinets, matched with hot air generators.
Lösung: CX-75A acts as circulation blower to circulate hot air inside the chamber and guarantee uniform temperature distribution.
High-temperature Condition: Must use heat-insulated CX-75A with heat insulation plate to avoid motor burnout caused by heat conduction.
🛠️ Case 8: Equipment Cooling & Workpiece Chip Removal for Machine Tools
Arbeitszustand: Wave soldering, reflow soldering cooling, CNC machine tool chip blowing, auxiliary cooling for laser equipment.
Lösung: Continuous directional airflow to cool workpieces and blow away metal cutting dust.
Selection Trade-off Guidelines (Industrial Practice)
- Multiple elbows and high filter resistance → CX-75A medium pressure blower; low resistance only requiring large flow → multi-wing centrifugal fan; high negative pressure required → high-pressure ring blower.
- Single-phase 220V for small standalone equipment; three-phase 380V recommended for factory long continuous operation.
- Für staubige, humid or high-temperature conditions, upgrade accessories or select heat-insulated / corrosion-resistant versions.
Alternative Models for Similar Applications
Lower flow: CX-75SA (0.4kW)
Höherer Durchfluss: CX-100A (1.5kW)
Complete Industrial Fan Selection Methodology (Applicable for CX Turbo Blowers, Ring Blowers, Centrifugal Fans, Technische Version)
Kernlogik: Define working condition boundaries → Calculate air flow and pressure → Select fan type → Verify medium & environment → Select motor & material → Check safety margin → Match accessories
Schritt 1: Collect Basic Working Condition Parameters (Prerequisite for Selection)
- Anwendung: Positive pressure blowing / Negative pressure suction / Hot air circulation / Pneumatic conveying / Aeration / Dust collection
- Medium: Ambient air / Hot air / Dust-laden air / Moisture/oil mist / Corrosive gas
Clean ambient air: Standard aluminum turbo blower (CX-75A for example)
Hohe Temperatur: Heat-insulated turbo blower, high-temperature resistant centrifugal fan (heat insulation plate required to prevent heat transfer to motor)
Starker Staub: Thickened impeller, Vorfilter; heavy dust service: wear-resistant coating or stainless steel impeller
Corrosive gas: FRP / stainless steel housing with anti-corrosion coating
- Mittlere Temperatur: Ambiente (≤40℃), Mittlere Temperatur (40~180℃), Hohe Temperatur (>180℃)
- Umfeld: Drinnen / Im Freien, feucht, explosion-proof requirement (Ex-proof motor mandatory for flammable gas/dust)
- Betriebsmodus: Intermittent start-stop / 24h continuous operation (Drehstrommotor, Class F insulation preferred for continuous duty)
Schritt 2: Calculate Required Air Flow Q (m³/min)
Air Flow = Process Base Flow × Safety Factor
- Source of base process flow:
Dust collection: Air velocity at suction port × cross-sectional area of suction port; recommended suction velocity for dust:18~25m/s
Air knife drying: Cross-sectional area of air knife × designed outlet velocity
Pneumatic conveying: Air volume for material carrying + pipeline leakage
Combustion air supply: Theoretical air volume calculated by fuel combustion
- Sicherheitsfaktor: Normally 1.1~1.3; adopt 1.3 for long pipelines, many elbows and easy filter clogging.
Beispiel: Process requirement 10m³/min, factor 1.3, selected air flow ≥13m³/min → CX-75A is suitable.
Step3: Calculate Total Pressure P (Pa/kPa)【Most Common Pitfall】
Fan total pressure is used to overcome total system resistance: pipeline resistance + filter resistance + elbows/reducers/valves + internal equipment resistance
- Resistance components:
Friction loss of straight pipe
Local resistance (90° Ellenbogen, tee, reducer, flexible joint, air damper, Filter)
Equipment internal resistance (burner, filter cartridge, air knife, aeration disc)
- Auswahlregel: Fan rated pressure ≥ Total system resistance × 1.1~1.2 margin
Quick comparison of fan categories by pressure range:
| Fan Type | Druckbereich | Anwendung | Modellbeispiel |
| Multi-wing Centrifugal Fan | <1kPa | Großer Durchfluss, geringer Widerstand, oven circulation, general exhaust | Multi-wing centrifugal fan |
| Turbo Medium-pressure Blower | 1~10kPa | Medium resistance, dust collection, air knife, combustion air, short-distance conveying | CX-Serie (CX-75A) |
| Ring Blower | 10~100kPa | High vacuum suction, vacuum feeding, narrow air knife | RB, HG Series |
Wichtige Erinnerung: Do NOT select fan only by power rating! For same 0.75kW, ring blower delivers high pressure but low flow; CX-75A features medium pressure and large flow.
Step4: Selection of Fan Structure & Antriebstyp
- Direct-coupled (CX-Serie): Motor and impeller coaxial, kompakte Größe, wartungsfrei, feste Geschwindigkeit; Geeignet für kleine & medium power and 24h continuous running, CX-75A belongs to this type. Nachteil: Speed cannot be adjusted without VFD.
- Belt Drive: Speed adjustable via pulley, for larger power; disadvantage: belt periodic replacement, maintenance required.
- Coupling Drive: High-power industrial centrifugal fans for large dust collection and ventilation.
Step5: Motor, Stromversorgung & Protection Class Selection
- Stromversorgung:
Einphasig 220V: Small power, intermittent operation of standalone machine
Dreiphasig 380 V: Preferred for continuous factory operation, higher efficiency and better overload capacity
- Isolationsklasse: Class F recommended for continuous operation; Class H for high temperature
- Schutzklasse:
IP54: Normal dry workshop
IP55: Feucht & dusty workshop (common for CX series)
IP65: Heavy dust and water spray environment
- Explosion Proof: Ex-proof motor required for flammable dust/gas.
Step6: Working Condition Verification (Eliminate Unsuitable Models)
- Pneumatic Conveying: Kurzstrecke, low concentration → CX turbo blower; long-distance high concentration → Roots blower
- Negative Pressure Dust Extraction: Prioritize negative pressure check when pipeline resistance is high; Max negative pressure of CX-75A is 1.7kPa, switch to ring blower if exceeding.
- Hot Air: Standard CX fan cannot be used directly for hot air; heat conduction will burn motor, use CX-H heat-insulated model with heat shield.
- Noise Requirement: Install inlet/outlet silencer, shock pad and flexible joint for noise above 65dB.
Step7: Selection of Auxiliary Accessories (Indispensable for System, Often Neglected)
Inlet side: Air filter (mandatory for dusty application), silencer, vacuum/pressure gauge
Outlet side: Schalldämpfer, Rückschlagventil (prevent backflow after shutdown), manual/electric damper, flexible canvas joint
Base: Shock-absorbing foot pads to reduce vibration transmission; flexible joint is mandatory for rigid pipe connection to avoid casing crack.
Step8: Simplified Decision Flow Chart for CX-75A Selection
- Process air flow 8~13m³/min, total system resistance 1~2.4kPa
✅ Prefer CX-75A (0.75kW Turbo Medium-pressure Blower)
- Air flow less than 8m³/min, resistance 1~2kPa → CX-75SA (0.4kW)
- Air flow>13m³/min, resistance 2~3kPa → CX-100A (1.5kW)
- System resistance>3kPa → Abandon CX turbo blower, select ring blower
- Resistance<1kPa, only large circulation flow required → Multi-wing centrifugal fan
Step9: Häufige Auswahlfehler
- ❌ Select fan only by motor power: Fans with identical power rating have huge difference in air flow and pressure for different types.
- ❌ No resistance margin reserved: Filter clogging increases system resistance in service and leads to insufficient flow.
- ❌ No filter for dusty working conditions, resulting in rapid impeller wear and shortened service life.
- ❌ Use standard CX blower directly for high-temperature air, causing motor burnout by heat conduction.
- ❌ Rigid pipe connection at inlet/outlet, vibration causes casing crack and weld fracture.
Step10: Deliverable List for Fan Selection Document
- Process air flow and total system resistance
- Medium parameters, Temperatur, dust condition
- Fan model, operating point on P-Q performance curve (must stay within high-efficiency zone)
- Motor parameters: Stromspannung, Leistung, Isolierung, Schutzklasse, explosion-proof requirement
- Material, Einlass & outlet dimension
- Accessory list and vibration isolation scheme
CX Turbo Medium-pressure Blower Full Model List (50Hz, Standard Ambient Model, Same Series as CX-75A)
Suffix Description:
A: Standard direct-coupled type; H: High-temperature heat-insulated model (CX-XXAH), fitted with heat shield for hot air service
Stromversorgung: 1~ Single-phase 220V / 3~ Three-phase 380V; small models support both single & three phase, large models only three-phase
Größe: IN=Inlet, OUT=Outlet; flow and pressure refer to maximum parameters under 50Hz
| Modell | Leistung(kW) | Max Air Flow(m鲁/min) | Max Positive Pressure(kPa) | Max Negative Pressure(kPa) | Einlass & Auslass(mm) | Nettogewicht(kg) |
| CX-65A | 0.2 | 4.5 | 1.1 | 0.7 | IN100 / OUT65 | 7 |
| CX-75SA | 0.4 | 7 | 1.6 | 1.1 | IN100 / OUT75 | 10 |
| CX-75A | 0.75 | 13 | 2.4 | 1.7 | IN125 / OUT100 | 14~16 |
| CX-100A | 1.5 | 20 | 3 | 2 | IN125 / OUT100 | 26~28 |
| CX-125A | 2.2 | 32 | 3.7 | 2.4 | IN252 / OUT125 | 36~38 |
| CX-150A | 3.7 | 46 | 4.4 | 3.2 | IN252 / OUT150 | 52~54 |
Derived High-temperature Models (CX-XXAH, with Heat Shield for Hot Air / Furnace Combustion)
CX-75SAH (0.4kW, high temp version of CX-75SA)
CX-75AH (0.75kW, high temp version of CX-75A, for oven and burner hot air supply)
CX-100AH (1.5kW)
CX-125AH (2.2kW)
CX-150AH (3.7kW)
Schnellauswahl-Referenz
- CX-65A (0.2kW): Low flow and low resistance, small equipment cooling and simple air blowing
- CX-75SA (0.4kW): Low power blow/suction, small label machines, small aquaculture aeration
- CX-75A (0.75kW): Am vielseitigsten, combustion air supply, air knife drying, single-station dust collection (Zielmodell)
- CX-100A (1.5kW): Dual-station dust collection, large flow air knife, pneumatic conveying
- CX-125A (2.2kW): Multi-station dust collector, oven hot air circulation, powder conveying
- CX-150A (3.7kW): Large dust collection, industrial furnace combustion air, large flow aeration
Wichtige Hinweise
- Models from different manufacturers (Vollwind, MANVAC, Ouguan etc.) have consistent performance parameters, only slight weight difference.
- Air flow and pressure rise by approx.15% under 60Hz; check 60Hz performance curve for export projects.
- This series is turbo medium-pressure blower, not the same series as HTB multi-stage turbo blower and RB high-pressure ring blower, Verwechseln Sie sie nicht.
Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter