ETA REX12-TA2-107 Modular Circuit Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

 ETA REX12-TA2-107 Modular Circuit Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Leistungsschalter/

ETA REX12-TA2-107 Modular Circuit Breaker

ETA REX12-TA2-107 Modular Current Protection Circuit Breaker Model Code Breakdown Model split: REX12 TA2 107 REX12: ETA REX12 series modular current protection circuit breaker (electronic overload protector / miniature electronic circuit protector, DIN-Schienenmontage) TA2: Sub-series functional code, 2-channel universal type for DC and AC, equipped with temperature monitoring and fault signal output 107: ...

  • Produktdetails

ETA REX12-TA2-107 Modular Current Protection Leistungsschalter

  1. Aufschlüsselung des Modellcodes

Model split: REX12 TA2 107

  1. REX12: ETA REX12 series modular current protection circuit breaker (electronic overload protector / miniature electronic circuit protector, DIN-Schienenmontage)
  2. TA2: Sub-series functional code, 2-channel universal type for DC and AC, equipped with temperature monitoring and fault signal output
  3. 107: Rated current specification code → Rated current 7A
  4. Brand Overview

ETA (Swiss ETA): A global brand of industrial electronic protection components, specializing in miniature equipment circuit breakers, electronic overcurrent protectors and thermal-magnetic circuit breakers. Widely applied in industrial control cabinets, robotics, Schienenverkehr, photovoltaic energy storage and medical devices.

REX12 Series: Ultra-thin modular electronic protection devices as a replacement for traditional fuses, featuring remote signal feedback and precise segmented current limiting.

III. Kernspezifikationen (REX12-TA2-107)

Elektrische Spezifikationen

Rated Current In: 7A

Kanäle: Dual independent protection channels (separate current limiting and fault alarm for two outputs)

Betriebsspannung: Universal for DC 24V / AC 24~230V

Reisetyp: Electronic inverse-time overload protection + instantaneous short-circuit cut-off

Signalausgang: TA2 standardly equipped with two sets of passive fault contacts (NO/NC, connectable to PLC for fault signal collection)

Montage: Standardmäßige 35-mm-DIN-Schiene, module width only 12mm per channel

Funktionsmerkmale

  1. Independent circuit protection for dual channels without mutual interference
  2. Precise electronic current limiting, eliminating aging issues of traditional fuses
  3. Manual reset after overload/short-circuit tripping; no consumable replacement required
  4. Remote fault alarm contacts for automated equipment monitoring
  5. Geringer Stromverbrauch, ultra-thin design dedicated to dense cabinet wiring
  6. Typische Anwendungsszenarien

24V DC output circuit protection for industrial PLCs and servo drives

Branch power supply protection for robot IO modules and sensors

Multi-channel DC power supply protection for medical equipment and test instruments

On-board control cabinets for rail transit and auxiliary circuits of energy storage BMS

  1. Reference Alternative Models within the Same Series

REX12-TA2-103: 3A dual-channel

REX12-TA2-105: 5A dual-channel

REX12-TA2-110: 10A dual-channel

REX12-TA1-XXX: Basic single-channel model (without separate dual-channel alarm)

  1. Key Distinction Points

TA1 = single channel; TA2 = dual channel with independent fault signals; the last two digits of the three-digit suffix represent rated current (107 = 7A).

Full Technical Analysis of ETA REX12-TA2-107 Electronic Overcurrent Protector

> Notiz: The previous interpretation of the model suffix “107” was inaccurate.

  1. Digit-by-Digit Model Code Decoding

Standard full ordering format: `REX12 TA2 107 DC24V XA/XA`

The provided `REX12-TA2-107` is the abbreviated base model of the series; full purchasing models require supplementary suffix current specifications.

CodesegmentDefinition
REX12Main product series: 12.5mm ultra-thin modular electronic DC circuit breaker with standard Push-in spring terminals
TMontageart: Clip-on for standard 35mm DIN rail
AStrukturtyp: One set of load output terminals per channel with fixed rated current specifications
2Channel quantity: Dual independent protection channels with fully separate current limiting and status feedback
107Function version code: Standard dual-channel independent fault status signal output; basic version without bus communication
DC24VNennbetriebsspannung: 24V DC system, compatible with wide voltage range of 18~30V DC
XA/XARated current specification: Symmetrical dual-channel setting, optional 1A/1A, 2A/2A, 3A/3A, 4A/4A, 6A/6A
  1. Full List of Core Specifications

Elektrische Spezifikationen

ParameterWert
NennbetriebsspannungDC 24V (operating range: 18~30V DC)
Number of Channels2 electrically independent channels
Optional Rated Currents1A, 2A, 3A, 4A, 6A (symmetrical dual-channel configuration)
AuslöseeigenschaftenElectronic inverse-time overload protection + instantaneous short-circuit cut-off
KurzschlussausschaltvermögenMax. 40A DC
Capacitive Load ToleranceSupports startup of capacitive loads up to 20000渭F without false tripping
Status Signal OutputIndependent open-collector fault signal per channel, directly connectable to PLC DI modules
StatusanzeigeIndependent LED per channel: Green = Normal Operation, Orange = Overload/Short-Circuit Fault
Methode zurücksetzenManual push-button reset; one-click power recovery after fault elimination
Backup-SchutzBuilt-in blade fuse matching the rated current as a safety barrier against electronic component failure

Mechanisch & Mounting Specifications

ParameterWert
Module Width12.5 mm (single module integrating two channels)
Gesamtabmessungen (B × H × T)12.5 × 80 × 98.5 mm
VerkabelungsmethodeTool-free Push-in spring terminals
Applicable Wire Cross-Section0.5 ~ 2.5 mm² (flexibel / solid conductors)
Single Module WeightCa. 40 G
Power Distribution Expansion CapacityBis zu 16 protection modules can be connected in parallel to one power supply set when paired with EM12-T power distribution modules

III. Schutzmechanismus & Funktionsprinzip

  1. Precision Electronic Sampling: Built-in current sensors collect real-time circuit current; a dedicated chip executes inverse-time tripping algorithms. Higher overload multiples lead to faster tripping, precisely matching cable thermal withstand capacity with far lower dispersion than traditional fuses.
  2. Microsecond-Level Short-Circuit Cutoff: Upon detection of short-circuit current, semiconductor switches shut down within microseconds to limit fault current rise, preventing surge damage to downstream loads and avoiding tripping of the upstream switching power supply.
  3. Fail-Safe Backup Protection: Built-in blade fuses compliant with IEC 60127-4 and UL248-14 standards. When electronic protection components malfunction, the fuse acts as the final safety barrier, Einhaltung der EN 60204-1 for machine equipment cable protection.
  4. Selective Disconnection: Only the faulty branch is cut off while other branches remain powered, greatly improving system availability and avoiding full power supply shutdown caused by single-point faults.
  5. Installation Wiring & Systemkonfiguration

Power Distribution Connection

Power input is uniformly connected via EM12-T power distribution modules. Side bridging arms enable parallel power supply between modules without additional jumper wires. A single set of distribution modules supports up to 16 parallel protection modules; matched PM12-T potential expansion modules enable separate GND circuit routing.

Laden & Signalverkabelung

Load Side: One set of Push-in terminals per channel for direct connection to load positive circuits; Abisolierlänge: 8~10mm.

Signal Side: Independent fault signal output terminals per channel, connectable to PLC DI modules for remote fault monitoring and alarm.

Vorsichtsmaßnahmen bei der Installation

Mount modules vertically on DIN rails with at least 10mm clearance above for heat dissipation.

AC voltage input is strictly prohibited; the device is only applicable to 24V DC systems.

  1. Sicherheitszertifizierungen & Compliance-Standards

UL 508 Certification for Industrial Control Equipment

UL 2367 Solid-State Circuit Breaker Certification

cULus Dual Certification for Canada & die Vereinigten Staaten

IN 60204-1 Electrical Equipment Standard for Machinery (cable protection compliance)

IEC 60127-4 Miniature Fuse Standard (backup fuses)

RoHS Environmental Compliance

  1. Model Selection Comparison within the Same Series
ModellKanalmengeKernunterschiedeNennstrombereich
REX12-TA1-107Single ChannelSingle-circuit protection, single signal output1A~10A
REX12-TA2-107Dual ChannelIndependent dual-circuit protection, dual signal outputs1A~6A (symmetrical)
REX12-TB2-107Dual ChannelTwo sets of load terminals per channel for parallel connection of two loads1A~6A (symmetrical)
REX12D-TA2Dual ChannelIntelligent type supporting Profinet/EtherCAT communication with adjustable currentAdjustable 1A~10A

VII. Typische Anwendungsszenarien

Branch protection for 24V DC power distribution systems in industrial control cabinets

Power supply protection for field components including PLC IO modules, Sensoren, solenoid valves and indicator lamps

Automatisierte Produktionslinien, robot control cabinets and semiconductor manufacturing equipment

Auxiliary circuits of new energy storage BMS and on-board control cabinets for rail transit

Multi-channel low-voltage power supply protection for medical testing equipment and laboratory instruments

VIII. Common Fault Troubleshooting Matrix

FehlerphänomenUrsachenanalyseSchritt-für-Schritt-Lösungen
Orange LED stays on after power-on with no outputUnresolved short circuit or continuous overload on load side1. Disconnect all loads; 2. Press reset button to verify module recovery; 3. Reconnect loads one by one to locate short-circuit point
Frequent tripping under loaded startupExcessively large capacitive load or excessive startup current peak1. Confirm load startup current peak value; 2. Replace with higher current specification; 3. Check for hidden short circuits
No voltage output after resetInternal backup fuse blown (triggered after electronic protection failure)Replace the entire protection module with identical specifications; do not short-circuit the fuse or disassemble for self-repair
No fault signal outputReversed polarity of signal wiring or incorrect PLC DI configuration1. Verify positive/negative polarity definition of signal terminals; 2. Check common terminal polarity and parameter settings of DI modules
  1. Terminal Pinout & Verkabelungsdefinition

The REX12-TA2-107 adopts a system-level bridging architecture. Power input is connected in parallel via side-mounted matching EM12-T power distribution modules, while load and signal terminals are wired directly on the front face. Terminals are divided into three major functional zones:

  1. Terminal Zones & Pin Definitions

From top to bottom on the module front (operation side), terminals are divided into power bridging zone, load output zone and signal output zone. Detailed pin definitions are as follows:

ZoneKlemmenmarkierungFunktionsbeschreibungVerkabelungsspezifikation
Top Power Bridging ZoneInternal bridging contactsAutomatically parallel DC24V positive power supply when installed side-by-side with EM12-T distribution modules; no external wiring requiredUniformly powered by distribution modules, max. 40A per circuit
Middle Load Output ZoneLOAD+ CH1Kanal 1 load positive output (positive switching type; positive circuit cut off upon overcurrent)0.5~2.5 mm簡 solid/flexible wires, stripping length 8~10mm
Middle Load Output ZoneLOAD+ CH2Kanal 2 load positive output, fully electrically isolated from Channel 1Das Gleiche wie oben
Lower Signal Output ZoneSi CH1Kanal 1 fault signal output (open-collector, negative switching; conducts to negative pole during faults)0.5~1.5 mm簡 signal wires, connected to PLC DI modules
Lower Signal Output ZoneSi CH2Kanal 2 independent trigger fault signal outputDas Gleiche wie oben
Common Negative CircuitGNDLoad negative and common signal negative require external connection to power supply negative; unified distribution via PM12-T potential expansion modulesEquipotential with power supply negative

> Core Note: This model is a positive-side protection type, which only cuts off the load positive circuit while the negative circuit remains continuously connected. Fault signals are low-level active (NPN type), directly compatible with DI input modules of mainstream PLC brands including Siemens and Mitsubishi.

  1. Verkabelungsspezifikationen & Vorsichtsmaßnahmen

All terminals are Push-in spring terminals; wires can be inserted or removed by pressing the orange release button without tools.

The module must be installed side-by-side with EM12-T series power distribution modules to receive operating power; standalone modules cannot be powered on.

A single EM12-T distribution module supports up to 16 parallel REX12 protection modules with total current not exceeding 40A.

No additional current limiting required for capacitive load startup; each channel supports shock-free startup of capacitors up to 20000μF.

Induktive Lasten (Magnetventile, Relais) require freewheeling diodes connected in parallel on the load side to prevent reverse voltage breakdown of internal MOSFETs.

  1. Cross-Brand Compatible Replacement Solutions

The ETA REX12 series adopts a proprietary bridging power distribution architecture, with no cross-brand models offering 1:1 fully compatible pinouts. Two replacement categories sorted by ascending replacement cost are listed below:

Lösung 1: Same Footprint Functional Replacement (Retain DIN Rail Space, Replace Distribution & Protection Modules)

Suitable for cabinets with limited space where the 12.5mm dual-channel width must be maintained; power distribution modules also require simultaneous replacement.

MarkeReplacement Model CombinationKernspezifikationenDifferenzbeschreibung
Phoenix Contact2 pcs PTCB E1 single-channel (z.B. 2800905 6A) + base moduleSingle channel width 6.2mm, total width 12.4mm for two pieces; 24VDC; with fault signal output; Push-in wiringNearly identical width; two single-channel units combined to realize dual channels; independent wiring power supply without bridging architecture
WAGOCombined 787-2861 series single-channel unitsSingle channel width 6mm, total width 12mm for two pieces; 24VDC; independent signal contacts; spring wiringSpring wiring terminals, current specifications cover 1~10A; requires separate power supply wiring

Lösung 2: Independent Dual-Channel Functional Replacement (Direct Complete Unit Replacement, No Matching Distribution Modules Required)

Suitable for scenarios where the original REX12 power distribution system is not retained and independent wiring is adopted; higher integration and more flexible wiring.

MarkeErsatzmodellKernspezifikationenKompatibilität
WAGO787-1662/000-060Independent dual-channel protection; 24VDC; adjustable current 2~10A; common group alarm contacts; width 22.5mmFull function coverage with adjustable current and remote reset; etwas breiter, suitable for cabinets with ample space
WeidmüllerESM 24VDC 2CH 6AFixed current dual channels; 24VDC; fault signal output; DIN-Schienenmontage; Push-in wiringIndustrial-grade electronic circuit breaker with nearly identical protection characteristics and consistent wiring method
Schneider ElectricDual-channel ABL2REM2402024VDC; independent dual-channel protection; status indicators; Breite 18mmMatching model for Schneider power distribution systems, ideal for full-Schneider cabinet solutions

Key Replacement Reminders

  1. Power Distribution Architecture Difference: The side bridging power supply of REX12 is an ETA patented design; all other brands adopt independent terminal wiring, requiring re-routing of power input lines during replacement.
  2. Signal Type Matching: REX12 outputs NPN open-collector signals; confirm the signal output type (NPN/PNP/passive contact) of replacement models to match the existing PLC system.
  3. Auslöseeigenschaften: All alternative models feature electronic inverse-time overload protection and instantaneous short-circuit cutoff, with protection curves basically consistent with REX12 for direct replacement.

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen