Omron S82J-05024DD-Schaltnetzteil - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

 Omron S82J-05024DD-Schaltnetzteil - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

SPS/

Omron S82J-05024DD-Schaltnetzteil

Auslaufmodell (Order acceptance terminated in March 2011). It is an older 50W industrial switch mode power supply of the S82J series, widely used for 24V power supply in control cabinets. Only second-hand or stock spare parts are available on the market. Model Decoding S82J-05024DD Segment Definition S82J Series name, general-purpose AC-DC switch mode power ...

  • Produktdetails

Auslaufmodell (Order acceptance terminated in March 2011). It is an older 50W industrial switch mode power supply of the S82J series, widely used for 24V power supply in control cabinets. Only second-hand or stock spare parts are available on the market.

  1. Model Decoding S82J-05024DD
SegmentDefinition
S82JSerienname, general-purpose AC-DC switch mode power supply
50Nennleistung: 50W
24Ausgangsspannung: DC24V
DMetal enclosed housing with front terminal block
DDIN rail mounting bracket (built-in DIN rail clip)
  1. Grundlegende elektrische Spezifikationen

Eingangsspannung: AC85~264V wide universal input, 50/60Hz, kompatibel mit globalen Stromnetzen

Ausgangsbewertung: DC24V, 2.1A, 50W

Output Adjustment: V.ADJ-Potentiometer, ±10% voltage trim

Schutzfunktionen: Überstromschutz (105~160% rated current, foldback type, Automatische Wiederherstellung), Kurzschlussschutz; No overvoltage protection for 50W variant

Kühlung: Natürliche Konvektionskühlung, lüfterlos

Effizienz: Typisch >75%

Spannungsbeständig: Input to output AC3000V isolation

Sicherheitszertifizierungen: UL508, cUL, EN50178, CE; EMC EN61204-3 Class A

Montage: Dual-purpose: DIN rail mounting and panel mounting

  1. Terminaldefinition (Front Terminals)

L: AC Line

N: AC-Neutralleiter

⎓: Schutzerde (PE)

+V: DC24V positiv

-V: DC24V Negative

V. ADJ: Output voltage adjustment potentiometer

  1. Installation & Betriebshinweise
  2. Natürliche Konvektionskühlung. Maintain ≥25mm clearance top and bottom for ventilation; do not seal inside enclosed housing. Clean dust periodically in dusty environments.
  3. Anzugsdrehmoment der Klemmen: 0.5~0.8 N·m to prevent loose connections and overheating.
  4. Do NOT feed power directly from VFD output side. Fuse is recommended on input side.
  5. After overcurrent / short-circuit protection triggers, remove the load, power off and wait approximately 90 seconds for auto-reset.
  6. Ersatzauswahl (Discontinued Substitute Options)
  7. Omron OEM recommended: S8JX-N050CD (S8JX series, 50W 24V DIN rail). Dimensions differ; adapter bracket available to fit original mounting holes.
  8. New generation upgrade: S8VK-C05024 (S8VK series, currently active product, 50W/24V DIN rail, improved protection, Empfohlen für neue Projekte).
  9. Inländische kompatible Alternativen: Meanwell LRS-50-24, Delta PMC-050-24, gleiche Nennleistung, DIN-Schienenmontage. Beachten Sie die unterschiedlichen Abmessungen des Montageausschnitts.
  10. Allgemeine Fehlerbehebung (Wichtige Inspektionspunkte für gebrauchte Ersatzteile)
  11. Kein Gleichstromausgang, während der Wechselstromeingang normal ist

Überprüfen Sie die durchgebrannte interne Eingangssicherung (Nicht ersetzen, ohne den Back-End-Kurzschluss zu prüfen)

Gealterte Elektrolytkondensatoren mit gewölbter Oberseite (Häufiger Fehler bei alten Geräten; Es ist sehr wahrscheinlich, dass die Kapazität nach Ablauf der Zeit nachlässt 10 Dienstjahre)

  1. Niedrige Ausgangsspannung, Spannungsabfall unter Last

Defekte Elektrolytkondensatoren; latenter Kurzschluss in der Last; lose Klemmschrauben

  1. Der Schutz löst sofort beim Einschalten aus

Kurzschluss auf der Ausgangsseite; Ausfall des internen Stromversorgungsgeräts; Gleichrichterbrücke durch Eingangsstoß beschädigt

Gebrauchtinspektionsverfahren: Messen Sie die Ausgangsspannung im Leerlauf → Welligkeitstest unter Last → Langfristiger Temperaturanstiegstest bei Volllast. Konzentrieren Sie sich auf die Prüfung auf Kondensatorlecks und Ausbeulungen.

  1. Ersatzteile & Foreign Trade Information

HS-Code: 85044014 (Static converter, switch mode power supply)

Gewicht: ca. 0.8~1kg

Beschaffungserinnerung: Brand new original factory stock is exhausted. Beim Kauf gebrauchter Geräte, verify appearance, repair traces and capacitor condition; prioritize units with load test reports.

Omron S82J-05024DD (50W, Metallgehäuse + DIN rail bracket) Gesamtabmessungen

Einheit: mm

Länge (horizontal, Klemmenseite): 161 mm

Höhe (Vertikale): 97 mm

Tiefe (cabinet front to rear): 46 mm

The covered model shares the same main body dimension as bare PCB version. The DD version is equipped with DIN rail clips, maximum outward protrusion 12mm (max 9mm in sliding state).

Panel Mounting Holes

Side mounting holes: 2×M3.5, hole diameter 3.5mm

Terminal region: Terminals protrude approx.7mm forward from main body, reserve this space during cabinet layout.

Gewicht

Main body approx. 400G (without DIN rail bracket); complete unit with DIN rail clip approx.450g

Dimension Comparison for Replacement Models

  1. S8VK-C05024 (new Omron 50W 24V DIN rail PSU): 125 × 90 × 40 mm, schmalere Breite, different mounting cutout. Modification or adapter bracket required for direct replacement.
  2. Meanwell LRS-50-24: 129 × 97 × 30 mm, geringere Tiefe.

Notiz: S82J-05024DD ist ein älterer dicker Formfaktor. Während der Schrankaufteilung, Reservieren Sie mindestens 55 mm Platz vorn und hinten (46mm Tiefe + 7 mm Anschlussüberstand), ≥25mm Lüftungsspalt oben und unten.

Omron S82J-05024DD Englische Verkabelungsanweisungen

Modell: S82J-Serie 50 W 24 V DIN-Schienen-SMPS, Front-Terminal-Reihenfolge (von oben nach unten): L, N, PE, +V, -V; V.ADJ-Trimmpotentiometer an der Seite.

  1. Terminaldefinition
TerminalmarkierungNameBeschreibung der Verkabelung
LAC LineAn das stromführende Kabel des AC-Eingangs anschließen (220V L)
NAC-NeutralleiterAn den Neutralleiter des AC-Eingangs anschließen (220V N)
⎓ / FGSchutzerde PEAn die Schutzerde des Schranks anschließen, Zum Schutz vor Stößen und zur Geräuschreduzierung ist eine Erdung zwingend erforderlich
+VDC24V positiv24V positiv für Lasten (SPS, Sensoren, Relais usw.)
-VDC24V NegativeLaden Sie eine gemeinsame 0-V-Referenz
V. ADJAusgangsspannungs-TrimmpotentiometerEinstellbereich DC21,6V~26,4V (±10 % des Nennwerts). Werkseitig auf 24 V voreingestellt, Mit kleinem Schlitzschraubendreher einstellen.

Indikator: Die grüne DC-ON-LED leuchtet, wenn die Ausgangsleistung normal ist; AUS, wenn keine Ausgabe erfolgt oder unter Schutz steht.

  1. Standard Wiring Procedure
  2. Power-Off-Betrieb: Confirm upstream circuit breaker is disconnected before wiring. Never work with live power.
  3. AC Input Side Wiring

L: Connect to AC220V live line

N: Connect to AC220V neutral line

FG earth terminal reliably bonded to cabinet PE protective earth

Wide input range AC85~264V, no voltage selector switch, global anwendbar.

  1. DC Output Side Wiring

+V → Load DC24V positive

-V → Load DC0V negative

Strictly prohibit shorting +V and -V; short circuit will trigger foldback overcurrent protection.

  1. Klemmenfestziehen: Screw torque 0.5~0.8 N·m to avoid hot loose contacts.
  2. Prüfung vor dem Einschalten: Verify no short circuit on input/output, no polarity reversal. Power on under no-load condition, measure +V/-V voltage and confirm green LED lights up.
  3. Belastungstest: Connect load only after no-load test passes.
  4. Recommended Cable Gauge

AC input cable: ≥0,75 mm² Kupferlitze

DC-Ausgangskabel: ≥1,0 mm² Kupferlitze; Verwenden Sie bei langen Kabelstrecken einen größeren Durchmesser, um den Spannungsabfall zu verringern.

  1. Wichtige betriebliche Vorsichtsmaßnahmen
  2. Schutzeigenschaften: Überstrom- und Kurzschlussschutz sind vom Typ Auto-Reset. Fehlerlast entfernen, Schalten Sie das Gerät aus und warten Sie ca. 90 Sekunden auf die Wiederherstellung. Dieses 50-W-Modell verfügt über KEINEN eingebauten Überspannungsschutz.
  3. Verbotene Operationen

Schließen Sie den VFD-Ausgang NICHT an die L/N-Klemmen der Stromversorgung an

Eine Verpolung der Ausgangsklemmen führt zu Schäden am Gerät

Mehrere S82J-05024DD-Einheiten können zur Leistungserweiterung nicht direkt parallel geschaltet werden (Dieser stromsparende S82J unterstützt keinen Parallelbetrieb)

  1. Wärmeableitung: Natürliche Konvektionskühlung, Halten Sie oben und unten einen Lüftungsabstand von ≥25 mm ein. Nicht versiegeln.
  2. Erdungsanforderung: Der FG-Anschluss muss geerdet sein. Bei einem nicht geerdeten Gerät besteht die Gefahr eines Stromschlags und ein höheres EMI-Rauschen.
  3. Potentiometereinstellung: Do not turn V.ADJ to extreme limit in one step; adjust slowly while measuring voltage.
  4. Fehlerdiagnose

Green LED off after power-on: Check AC input, blown internal fuse or damaged power supply.

Grüne LED AN, voltage drops under load: Overloaded load, cable voltage drop or aged power supply with degraded capacitors.

Output cuts off immediately after power-on: Short circuit on output or leakage fault on load.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen