Vollständiges Modell: PNOZ s7 C 24VDC 4 NEIN 1 k.A
Pilz PNOZsigma Series Sicherheitsrelais
Grundlegende Spezifikationen
Bestell-Nr.: 750330
Liefern: 24 In DC
Sicherheitskontakte: 4 normalerweise offen (NEIN)
Hilfskontakt: 1 normalerweise geschlossen (k.A)
Breite: 22.5 mm
Funktion: For safety emergency stop, Schutztürüberwachung, two-hand control and other safety circuit evaluation
Serie: PNOZ s7 C (C = with cascade interface, for connecting extension modules)
Zertifizierungen: CE, UL, TÜV; Safety Level PL e/SIL 3 (Compliant with ISO 13849-1/IEC 62061)
Typische Anwendungen
Emergency stop button circuit monitoring
Schutztürschalter, Sicherheitsendschalter
Small automation machines, Werkzeugmaschinen, packaging machinery safety control
Can be cascaded with PNOZsigma extension modules (s0, s1, s2, s4, s5, s6, s7, s8, s9) zur Kontakterweiterung
Confusing Model Comparison
750107: PNOZ s7 (without C, no cascade function)
750330: PNOZ s7 C (cascade-capable version)
Hinweise zur Verkabelung
- S11/S12: Safety Input Channel 1
- S21/S22: Safety Input Channel 2 (Dual-channel monitoring)
- 13/14, 23/24, 33/34, 43/44: Four safety normally open outputs
- 51/52: Auxiliary normally closed feedback contact
- UB/0V: 24V DC-Stromversorgung
Ersatzreferenz
Ersatz gleicher Serie: Original product is preferred for the same specification; domestic safety relays can be used for functional replacement (PL level, contact configuration and wiring logic must be verified)
Upgrade: If more contacts are required, cascade with PNOZ s extension modules
Weitere Informationen
Schutzklasse: IP20 (DIN-Schienenmontage, Nur für den Schrankeinbau)
Montage: DIN-35-mm-Schiene
Betriebstemperatur: -10 ℃ ~ +55 ℃
PILZ 750330 (PNOZ s7 C) Verkabelungsanleitung + Checkliste zur Fehlerbehebung
Important Precaution: PNOZ s7 C is a contact extension module. It cannot be used as a standalone master module. It must be used with PNOZsigma master safety relays (s1/s2/s4/s5/s6 etc.); C = cascade connector, connected to master module via U-link. It is NOT an independent evaluation unit.
- Terminaldefinition
A1: 24VDC+
A2: 24VDC-
Sicherheitsausgänge (Force-guided normally open, for safety circuits)
13-14, 23-24, 33-34, 43-44 (4 sets n/o)
Hilfskontakt (Not allowed for safety cut-off circuits, only for PLC feedback/indicator lamps)
51-52 (1 set n/c)
Top side: Cascade slot + Terminator plug
- Two Wiring Schemes
Schema 1: Cascade with PNOZsigma Master Module (Empfohlen, with pulse detection)
- Mount master module and s7 C side by side on DIN rail, remove terminator plugs on both modules
- Insert PNOZsigma U-link connector; internal safety signals are transmitted from master module to s7C
- Master module is powered at A1/A2; s7C A1/A2 also requires separate 24V DC supply
- Route outputs 13-14/23-24/33-34/43-44 into contactor coil circuits; a 6A fuse is recommended to prevent contact welding
- 51-52 is wired to PLC digital input for status feedback
Cascade Rule: The terminator plug must be fitted on the LAST module of the cascade chain! Fault will be triggered if missing.
Schema 2: Hardwired extension for non-sigma series (PNOZ X etc., no U-link)
The safety output contact of the master relay is wired into the s7 C supply loop (master safety contact acts as enable for s7C power supply)
Master contact closed → s7C energized, all safety outputs closed
Master contact open → s7C de-energized, all safety outputs open
⚠️ No internal short-circuit pulse diagnosis in this mode. Safety architecture is downgraded, only for low-risk applications.
- Sicherheitsregeln für die Verkabelung
- Max. load for safety outputs: ≤6A, 240VAC; fuses are mandatory to avoid contact welding
- 51-52 auxiliary contact must not be used for safety cut-off, only for status signals
- Kabel: Copper wire with ferrule for cabinet wiring, Federklemme; IP20, no exposed wiring
- Emergency stop/safety gate logic is fully configured on the PNOZsigma master module (mode selector, dual-channel detection, auto/manual reset). s7C only follows the output state
- Check U-link connection regularly for vibration-prone applications (Werkzeugmaschinen, Förderer)
- Definition der LED-Anzeige (PNOZ s7C itself)
LEISTUNG: 24V supply present
AUS: Safety outputs closed (master module permits output)
FEHLER: Diagnostic error/fault lockout
IN1, IN2 indicators are located on the master module. The s7C extension module has no input indicators.
- Checkliste zur Fehlerbehebung (der Reihe nach)
Fehler 1: FAULT LED ON continuously, keine Ausgabe (am häufigsten)
Ursache 1: Terminator plug missing or not installed on the last module
Abhilfe: Ausschalten, fit terminator plug on the last module’s cascade slot, power on and reset
Ursache 2: U-link loose or not fully clipped
Abhilfe: Ausschalten, re-seat U-link and confirm locking
Ursache 3: No supply/reversed polarity/excessive voltage drop on A1/A2
Abhilfe: Measure A1-A2 voltage with multimeter, confirm stable 24VDC; check spring terminal loose connections
Ursache 4: Master module FAULT, wrong mode setting, short circuit on master input channels
Abhilfe: Troubleshoot master module first; s7C will only work normally once master is recovered
Fehler 2: POWER LED ON, OUT LED OFF, FAULT LED OFF
Ursache 1: Master safety relay is in safe-off state (E-stop pressed, safety gate open)
Abhilfe: Reset E-stop/close safety gate, confirm master OUT LED lights up
Ursache 2: Master module set to manual reset and reset button not pressed
Ursache 3: Wrong cascade order; master module is not the first unit in chain
Ursache 4 (hardwired mode): Master safety contact damaged/open circuit
Fehler 3: Intermittent FAULT trigger, output flickering
Ursache 1: U-link loose due to cabinet vibration (Werkzeugmaschinen, Förderstrecken)
Ursache 2: High ripple/insufficient capacity/frequent dip on 24V power supply
Ursache 3: Short circuit on output circuit, fuse blown and safety lockout activated
Ursache 4: Cross-wire/earth short circuit on master module input wiring (pulse detection triggers fault)
Fehler 4: FAULT latched, cannot reset after power cycle
Ursache: Internal safety contact welding (overload/short circuit without fuse protection)
Abhilfe: Module cannot be repaired; direkt ersetzen. Add fuses on output circuits to prevent recurrence.
Fehler 5: Master module normal, s7C output out of sync
Ursache: Poor U-link contact; or welded contact on intermediate contactor in hardwired configuration
- Standard Commissioning Procedure
- Ausschalten, mount on DIN rail, wire power supply, fit U-link and terminator plug
- Wire master module and set mode selector (adjust selector only when power OFF; changing under power will lock fault)
- Verify fuses on all safety output loops
- Einschalten. Master IN1/IN2 OK, master OUT ON → s7C POWER + OUT ON
- Funktionstest: Trigger E-stop/open gate → master OUT OFF, s7C OUT opens synchronously; reset and confirm synchronous closing
- Record: Safety function verification must be performed after every wiring change or module replacement
- Quick Comparison: s7 (750107) vs s7 C (750330)
750107: PNOZ s7, extension, no C, U-link cascade not supported
750330: PNOZ s7 C, extension, C version, U-link cascade supported (Ihr Modell)
Working Principle of PILZ 750330 (PNOZ s7 C)
Kernzusammenfassung: It has no input channels and no safety logic evaluation function. It is a follower-type extension module equipped with force-guided safety contacts. Safety judgement, dual-channel detection and short-circuit pulse diagnosis are all performed by the upstream PNOZsigma master module. The s7 C only synchronously follows the master safety command and feeds back its actual contact status to the master for verification.
Wichtig: PL e/SIL3 safety rating is determined by the master module. s7 C alone cannot raise the safety level.
- Internal Hardware Structure
Intern: Two independent safety relays with mechanically linked force-guided contacts, 4 safety normally open outputs + 1 auxiliary normally closed feedback contact
Stromversorgung: Independent 24VDC supply on A1/A2 (not powered by master module)
Top U-link port: Dual-channel drive signals + feedback return line, safety link; not ordinary communication bus
Terminator plug: Closing component for the end of cascade chain, used by master module to confirm chain integrity; fault is triggered if removed
- Standard Cascade Mode (U-link connection, recommended dual-channel safety architecture)
- Master module (s1/s2/s4/s5/s6 etc.) collects E-stop and safety gate signals, performs dual-channel comparison, cross-line short-circuit pulse detection and reset logic
- When safety conditions are satisfied, master sends synchronized dual-channel drive signals to s7 C via U-link
- s7 C receives valid drive signals → internal two safety relays pull in simultaneously, 13-14, 23-24, 33-34, 43-44 four safety contacts close
- Critical safety closed-loop: The actual contact state of s7 C is sent back to master module via cascade lines
Master continuously compares: issued command vs real feedback contact status
Matched: Normaler Betrieb
Mismatched (contact welding, failure to act, Drahtbruch, loose U-link): Master cuts drive immediately, whole safety chain locks FAULT, safety contacts force open
- Once safety trip condition occurs (E-stop pressed, Schutztür geöffnet): Master stops drive signal → s7C relays de-energize, all safety contacts open; status feedback is sent back to master for verification
This bidirectional verification is the core of force-guided contact + feedback monitoring, preventing dangerous failure mode where contacts remain conductive after open command due to welding.
- Hardwired Mode (without U-link, downgraded single-channel)
Master safety output contact is wired into s7C supply enable loop:
Master contact closed → s7C energized, outputs closed
Master contact open → s7C de-energized, Ausgänge offen
⚠️ Defect: No dual-channel feedback. Master cannot diagnose internal faults of s7C. Safety architecture no longer meets PL e, only for low-risk applications.
- LED Logic
LEISTUNG: A1/A2 24V supply OK
AUS: Valid drive signal received from master, safety contacts closed
FEHLER: Master detects chain anomaly (loose U-link, missing terminator, inconsistent feedback, broken cascade line), safety lockout activated
- Diagnosis Principle (Why missing terminator triggers FAULT)
The whole cascade chain forms a serial closed diagnostic loop: Master → s7C1 → s7C2 → … → terminator plug on last module.
Master continuously sends diagnostic pulses scanning the whole chain. The terminator acts as an end termination resistor to close the pulse circuit.
Plug removed → pulse circuit open → master detects broken chain and locks FAULT to prevent uncontrolled extension module behaviour.
- Function Division: Master vs s7 C
Mastermodul:
Connect E-stop/safety gate inputs
Dual-channel detection, cross-wire short-circuit detection, Reset-Logik
Send drive commands + receive feedback and fault judgement from all extension modules
PNOZ s7 C (750330):
No input terminals, cannot connect E-stop
Aktion: Pull in/open safety contacts synchronously
Feed back real contact status continuously to master for verification
Only increases available safety contacts, no safety logic evaluation
- Core Safety Design
Internal relays adopt mechanical force-guided structure: If one relay contact welds closed, the mechanical coupling ensures the other contact opens reliably. This anomaly is fed back to master and triggers fault lockout, avoiding dangerous “command open but contact conductive” failure.
Pilz PNOZ Safety Relay Order List
Notiz: PNOZsigma (750xxx/751xxx) is current mainstream series; PNOZ X (774xxx /777xxx /787xxx) is legacy classic series; PNOZmulti2 is programmable safety controller. s7 C (750330) is sigma contact extension module and cannot be used standalone.
Abkürzung: n/o=normally open, n/c=normally closed, n/o t=delayed-off normally open, SC=semi-conductor output
- PNOZsigma Series (24VDC, bevorzugt, PL e/SIL3)
Standalone Master Modules (can work alone for E-stop/safety gate)
| Bestell-Nr. | Vollständiges Modell | Kontaktspezif | Breite | Bemerkungen |
| 750101 | PNOZ s1 24VDC 2n/o | 2NEIN | 12.5mm | Einkanal, Basic |
| 750102 | PNOZ s2 24VDC 3n/o 1n/c | 3NO+1NC | 17.5mm | Einkanal |
| 750103 | PNOZ s3 24VDC 2n/o | 2NEIN | 17.5mm | Dual-channel short-circuit detection |
| 751103 | PNOZ s3 C 24VDC 2n/o | 2NEIN | 17.5mm | Cascade C version |
| 750104 | PNOZ s4 24VDC 3n/o 1n/c | 3NO+1NC | 22.5mm | Zweikanalig, weit verbreitet |
| 750105 | PNOZ s5 24VDC 2n/o 2n/o t | 2NO+2 delayed NO | 22.5mm | Delay-off type |
| 750106 | PNOZ s6 24VDC 3n/o 1n/c | 3NO+1NC | 22.5mm | Two-hand control dedicated |
| 750107 | PNOZ s7 24VDC 4n/o 1n/c | 4NO+1NC | 22.5mm | Verlängerung, no U-link cascade |
| 750330 | PNOZ s7 C 24VDC 4n/o 1n/c | 4NO+1NC | 22.5mm | Cascade C version, U-link compatible (Ihr Modell) |
| 750108 | PNOZ s8 24VDC 2n/o | 2NEIN | 12.5mm | Small contact extension |
| 750109 | PNOZ s9 24VDC 3n/o | 3NEIN | 17.5mm | Contact extension |
| 750110 | PNOZ s10 24VDC 2n/o | 2NEIN | 12.5mm | Dual-channel light curtain |
| 750111 | PNOZ s11 24VDC 4n/o | 4NEIN | 22.5mm | Zweikanalig |
| 750124 | PNOZ s4.1 24VDC | 3NO+1NC | 22.5mm | Special reset mode |
| 750126 | PNOZ s6.1 24VDC | 3NO+1NC | 22.5mm | Improved two-hand control |
| 750150 | PNOZ s20 24VDC | Semi-conductor output | 12.5mm | Pure semiconductor |
| 750151 | PNOZ s22 24VDC | Semi-conductor output | 17.5mm | Light curtain dedicated |
| 750130 | PNOZ s30 24VDC | 2NO+2 delayed NO | 22.5mm | Lange Verzögerung |
| 750152 | PNOZ s50 24VDC | Semi-conductor | 22.5mm | Semi-conductor safety output |
Sigma Accessories
| Bestell-Nr. | Beschreibung |
| 750008 | PNOZsigma U-link Cascade Connector |
| 750009 | Terminator Plug (mandatory at end of chain) |
- PNOZ X Legacy Series (AC/DC universal, for replacement of existing projects)
Basic E-stop/Safety Gate Models
| Bestell-Nr. | Modell | Kontakte | Liefern |
| 777303 | PNOZ X2P | 2NEIN | 24VAC/DC |
| 787059 | PNOZ X7P C | 2NEIN | 24VAC/DC |
| 774053 | PNOZ X7 | 2NEIN | 110VAC |
| 774055 | PNOZ X7 | 2NEIN | 120VAC |
| 774057 | PNOZ X7 | 2NEIN | 240VAC |
| 787100 | PNOZ X1P C | 3NO+1NC | 24VDC |
| 787310 | PNOZ X3P C | 3NO+1NC | 24VAC/DC |
| 774729 | PNOZ X6 | 3NEIN | 24VAC/DC |
| 774080 | PNOSIS 11 | 7NO+1NC | 24VAC/DC |
| 774006 | PNOSIS 10 | 6NO+4NC | 230-240VAC |
Delay-off XV Series
| Bestell-Nr. | Modell | Kontakte | Verzögerungsbereich |
| 777510 | PNOZ XV3P 30 | 3NO+2 delayed NO | 0.1~30s |
| 774610 | PNOZ XV3.1 30 | 3NO+1NC+2 delayed NO | 0.1~30s |
| 774618 | PNOZ XV3.1 300 | 3NO+1NC+2 delayed NO | 0.3~300s |
Two-hand Control P2HZ Series
| Bestell-Nr. | Modell | Kontakte |
| 777340 | P2HZ X1P | 3NO+1NC+2SC |
| 774350 | P2HZ X3 | 2NO+1NC |
| 774360 | P1HZ X1 | 2NEIN |
Contact Extension PZE Series (for PNOZ X master)
| Bestell-Nr. | Modell | Kontakte |
| 774580 | PZE X4 | 4NEIN |
| 777580 | PZE X4P | 4NEIN |
| 774590 | PZE X5 | 5NEIN |
| 777600 | PZE 9P | 7NO+2NC |
- PNOZmulti 2 Programmable Safety Controllers (Large machines, multi safety functions)
| Bestell-Nr. | Modell | Beschreibung |
| 772100 | PNOZ I B0 | Basiseinheit, erweiterbar |
| 772104 | PNOZ I B0.1 | B0 upgraded version |
| 772105 | PNOZ m C0 | Kompakt, nicht erweiterbar |
| 772138 | PNOZ m ES ETH | Ethernet-Kommunikationsmodul |
- Kurzanleitung zur Auswahl
- 750xxx = PNOZsigma new series; 750xxx without C = standalone/hardwired extension; 751xxx /7503xx with C = U-link cascade supported
- 774/777/787xxx = PNOZ X legacy series, for spare replacement only, nicht für neue Projekte empfohlen
- 772xxx = PNOZmulti2 programmable safety controller (not simple safety relay)
- s7 (750107) and s7C (750330) are both extension modules, cannot connect E-stop independently, must pair with sigma master
- Confusing Model Reference
750107: PNOZ s7, extension, no C, U-link cascade not supported
750330: PNOZ s7 C, extension, C version, U-link cascade supported