Schneider ATV310HU75N4E Frequenzumrichter - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Schneider ATV310HU75N4E Frequenzumrichter - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

SPS/

Schneider ATV310HU75N4E Frequenzumrichter

Entry-level economical three-phase VFD, version without built-in EMC filter Model Code Explanation ATV310: Altivar Easy 310 Serie (simple general-purpose vector type) H: Frame size code U75: Heavy-duty rating 7.5 kW N4: Three-phase 380~460 V E: Ohne eingebauten EMV-Filter (Contrast: ATV310HU75N4A with built-in EMC filter) ⚡ Rated Power & Current Heavy Duty (HD): 7.5 kW ...

  • Produktdetails

Entry-level economical three-phase VFD, version without built-in EMC filter

Erklärung des Modellcodes

ATV310: Altivar Easy 310 Serie (simple general-purpose vector type)

H: Rahmengrößencode

U75: Heavy-duty rating 7.5 kW

N4: Three-phase 380~460 V

E: Ohne eingebauten EMV-Filter (Contrast: ATV310HU75N4A with built-in EMC filter)

⚡ Rated Power & Aktuell

Robust (HD): 7.5 kW / 10 PS, continuous output 17 A; 60 s overload 170~200% (25.5 A)

Normaler Dienst (ND): 11 kW / 15 PS, continuous output 22.8 A; 60 s overload 110% (25.1 A)

Eingang: Three-phase 380–460 V, 50/60 Hz

Nettogewicht: 3.7 kg; fan cooling standard, Lärm 50 dB(A)

🧠 Control Modes

V/F-Steuerung (linear, quadratic energy-saving curve)

Sensorlose Vektorsteuerung (SVC, Open-Loop-Vektor)

Ausgangsfrequenz: 0.5 ~ 400 Hz

Schaltfrequenz: 2 ~ 12 kHz einstellbar, Werkseinstellung 4 kHz

Speed regulation range: 1:20 for asynchronous motors

Bremsen: Ca. 70% braking torque without braking resistor; bis zu 150% braking torque with external braking resistor

Slip compensation adjustable

📶 Communication & E/A

Standard Modbus RTU, 2-wire RS485, front RJ45 port

Baudrate: 4800/9600/19200/38400 bps, address 1–247

Terminals: 4 digital inputs LI, 1 analog input AI, Relaisausgang; supports potentiometer, Terminal Start/Stopp, Mehrgeschwindigkeit, PID (Lüfter & Pumpe)

🌡️ Ambient & Zertifizierungen

Schwere Beanspruchung: -10 ~ 55 °C without derating; short-time max 60 °C

Beschichtung: 3C3/3S2, suitable for standard control cabinets and light dust environments

Zertifizierungen: CE, EAC, RoHS, WEEE

Schutz: IP20 (Nur zur Schrankmontage)

📌 Typische Anwendungen

Förderer, Fans, Pumps, general machine tools, Materialtransport, speed regulation for ordinary asynchronous motors, suitable for simple speed control and constant pressure water supply.

Schneider ATV310 VFD Fault Code List (Compatible with ATV310HU75N4E)

Notiz: Codes starting with F = fault, locked trip; codes starting with -= status prompt, NOT faults. Fehler-Reset: Leistungszyklus / keypad reset / Kommunikation zurückgesetzt

FehlercodeFehlerbeschreibungHäufige UrsachenAbhilfemaßnahmen
F001Pre-charge faultFailed DC bus pre-charge on power-up, faulty charging circuit or bus capacitorCheck input power, Gleichrichterbrücke, Ladewiderstand; internal hardware fault requires repair
F002Power board identification errorMismatched control board & Leistungsplatine, inkompatible FirmwareModell überprüfen, reload firmware, replace matching boards
F003Power board incompatibilityWrong power board model, mixed spare partsReplace with original matching power board
F004Internal serial communication faultCommunication loss between control board and power board, loose ribbon cableRe-seat ribbon cable; replace board if damaged
F005Region code errorMismatched firmware regional versionFlash correct regional firmware
F006Current sensing circuit faultSampling circuit failure, damaged Hall sensorInternal hardware fault, send for repair
F007Internal temperature sensor faultBroken or faulty IGBT temperature sensorIf alarm occurs immediately on cold power-up, sensor is almost certainly damaged
F008CPU-FehlerMain controller anomaly, program runawayAus- und wieder einschalten; if ineffective, Steuerplatine austauschen
F009Over-braking (braking overspeed)Too short deceleration time, hohe Lastträgheit, faulty braking circuitVerzögerungszeit verlängern; install braking resistor / Bremseinheit; check bus voltage
F010ÜberstromMotor jam, Motorkurzschluss, incorrect auto-tune, load surgeCheck mechanical jamming; test motor insulation with megger; reduce switching frequency; re-run motor auto-tune
F011VFD overheatVerstopfter Luftkanal, defekter Lüfter, hohe Umgebungstemperatur, continuous heavy loadClean cooling air path; Lüfter prüfen; reduce ambient temperature; Betrieb herabsetzen
F012Process overloadPID / process protection threshold triggered, sustained overloadVerify process overload parameters, check load condition
F013MotorüberlastungLong-term motor overcurrent, thermal protection threshold set too lowCheck motor for stall; verify motor nameplate data; extend thermal protection time
F014Output single phase lossBroken motor cable, burnt output contactor contact, loose terminalCheck U/V/W output wiring, terminals and output contactor
F015All output phases lostMotor disconnected, all output contactors open, no-load detection alarm for small motorsÜberprüfen Sie die Motorverkabelung; disable phase loss detection for no-load test (parameter 605=00)
F016Überspannung im DC-BusHigh grid voltage, regenerative Energie beim Abbremsen, failed braking circuitEingangsspannung prüfen; Verzögerungszeit verlängern; Bremswiderstand einbauen
F017Verlust der EingangsphaseMissing one incoming phase, poor contact of circuit breaker, Sicherung durchgebranntCheck upstream power supply, circuit breaker and incoming terminals
F018MotorkurzschlussInter-phase short circuit on motor winding or power cableDisconnect motor and test VFD separately; megger motor insulation
F019ErdschlussOutput cable earth fault, Motorisolationsausfall, large leakage with multiple parallel motorsMegger motor and cable insulation; install output reactor
F020IGBT short circuitPower module breakdownDo NOT repeatedly power on; send for repair and replace power module directly
F021Kurzschluss am AusgangDirect short circuit on VFD output sidePower off and inspect power cable to eliminate short point
F027IGBT over-temperatureExcessive IGBT junction temperature, schlechte WärmeableitungPrioritize cooling fan and air duct inspection, Belastung reduzieren
F030DC bus undervoltageGrid voltage dip, kurzzeitiger Stromausfall, insufficient incoming capacityCheck incoming voltage; inspect circuit breaker and terminal connections; confirm grid capacity

Status Prompt Codes (Not Faults, Status Indication Only)

CodeBedeutung
1Fast stop activated
6Freewheel stop (coast stop) activated
0Freewheel stop complete, stehen zu

Supplementary Practical Information

  1. Fault history: Parameters 910~921 to view historical faults and current/voltage readings at fault occurrence
  2. Phase loss detection parameter: 605 output phase loss detection (00=disabled, 01=enabled). Disable temporarily for no-load commissioning, keep enabled for formal operation
  3. Motor auto-tune: Parameter 318. Auto-tune is recommended after motor replacement to reduce F010 and F013 alarms
  4. Methoden zurücksetzen: Keypad reset, digital terminal assigned fault reset, Modbus communication reset, power cycle reset

Complete Model List for Schneider Altivar Easy ATV310 VFD

Notiz: Altivar Easy main product is ATV310. Stromspannung: three-phase 380–460 V. Suffix E = without built-in EMC filter, A = with built-in EMC filter. HD = heavy-duty power rating, ND = normal-duty power rating

Erläuterung der Modellcodierung

ATV310: Altivar Easy 310 economical general-purpose vector VFD

H: Frame code

Leistungscodes: 037=0.37 kW, 075=0.75 kW, U15=1.5 kW, U22=2.2 kW, U30=3 kW, U40=4 kW, U55=5.5 kW, U75=7.5 kW, D11=11 kW, D15=15 kW, D18=18.5 kW, D22=22 kW

N4: Three-phase 380~460 V

E: Without built-in EMC filter|A: Mit eingebautem EMV-Filter

E-version List (No Built-in EMC Filter, your ATV310HU75N4E is in this list)

ModellHD Heavy DutyND Normal Duty
ATV310H037N4E0.37 kW / 0.5 PS0.55 kW / 0.75 PS
ATV310H075N4E0.75 kW / 1 PS1.1 kW / 1.5 PS
ATV310HU15N4E1.5 kW / 2 PS2.2 kW / 3 PS
ATV310HU22N4E2.2 kW / 3 PS3 kW / 4 PS
ATV310HU30N4E3 kW / 4 PS4 kW / 5 PS
ATV310HU40N4E4 kW / 5 PS5.5 kW / 7.5 PS
ATV310HU55N4E5.5 kW / 7.5 PS7.5 kW / 10 PS
ATV310HU75N4E7.5 kW / 10 PS11 kW / 15 PS
ATV310HD11N4E11 kW / 15 PS15 kW / 20 PS
ATV310HD15N4E15 kW / 20 PS18.5 kW / 25 PS
ATV310HD18N4E18.5 kW / 25 PS22 kW / 30 PS
ATV310HD22N4E22 kW / 30 PS30 kW / 40 PS

A-version List (Gleiche Macht, Eingebauter EMV-Filter, widely used in domestic projects)

Change suffix E → A, z.B.

ATV310H037N4A, ATV310H075N4A, ATV310HU15N4A … ATV310HD22N4A

Ergänzen: Another Altivar Easy Family Series ATV610 (High-power Easy Range)

ATV610 also belongs to Easy series, larger power range, 380–460 V three-phase, mainly for fan & Pumpenanwendungen

ATV610D11N4, ATV610D15N4, ATV610D18N4, ATV610D22N4, ATV610D30N4, ATV610D37N4, ATV610D45N4, ATV610D55N4, ATV610D75N4, ATV610D90N4, ATV610C11N4, ATV610C13N4, ATV610C16N4

General Common Parameters for Full ATV310 Range

Kontrolle: V/F + Sensorless Vector SVC

Kommunikation: Standard Modbus RTU (RJ45)

E/A: 4AUS, 1KI, 1 Relaisausgang

Schutz: IP20, Schrankmontage

Anwendung: Förderer, Fans, Pumps, general OEM machinery

Auswahlnotizen

  1. Heavy-duty applications (Heben, Extrusion, shock load) select according to HD rating; Fans & pumps with smooth light load can use ND rating
  2. For export CE EMC compliance, select A (eingebaute EMV); E version requires external EMC filter
  3. Upgrade-Alternative: ATV320 (höhere Leistung, encoder support, more expansion cards)

Schneider ATV310 (Altivar Easy) Leitfaden zur Anwendungsauswahl

Voraussetzung: ATV310 is an economical open-loop vector VFD, no encoder interface, closed-loop vector not supported. Two capacity ratings: HD (Robust) / ND (Normaler Dienst). Suffix A=built-in EMC filter, E=no built-in EMC filter, three-phase 380~460 V.

Selection rule: Shock load, häufiges Start-Stopp, stall risk → select HD; Fans & pumps with smooth light load → ND is acceptable

  1. Rated Current Quick Reference Table (Base Data)
ModellHD PowerHD Continuous CurrentND PowerND Continuous Current
ATV310H037N40.37 kW2.1 A0.55 kW2.7 A
ATV310H075N40.75 kW3.0 A1.1 kW4.2 A
ATV310HU15N41.5 kW4.1 A2.2 kW5.5 A
ATV310HU22N42.2 kW5.5 A3.0 kW7.2 A
ATV310HU30N43.0 kW7.2 A4.0 kW9.4 A
ATV310HU40N44.0 kW9.4 A5.5 kW11.7 A
ATV310HU55N45.5 kW11.7 A7.5 kW16.5 A
ATV310HU75N47.5 kW17.0 A11 kW22.8 A
ATV310HD11N411 kW24.0 A15 kW30.0 A
ATV310HD15N415 kW30.0 A18.5 kW37.0 A
ATV310HD18N418.5 kW37.0 A22 kW43.0 A
ATV310HD22N422 kW43.0 A30 kW57.0 A
  1. Anwendungsklassifizierung + Selection Scheme + Accessories Recommendation

Kategorie 1: Centrifugal Fans & Kreiselpumpen (Smooth Load, Quadratic Torque, ND Preferred)

Load characteristics: Niedriges Anlaufdrehmoment, stabiler Betrieb, no shock; suitable for PID constant pressure / constant airflow, long continuous running

Selection rule: Select by ND power rating

Recommended suffix: A for export CE projects (eingebaute EMV); E for standard domestic cabinets with independent EMC solution

Zubehör:

Braking resistor normally not required (coast stop acceptable)

Parameter: V/F quadratic curve, PID enable

Einschränkung: Large inertia smoke exhaust fans, high-temperature induced draft fans, suggest one size up, select HD

Beispiel: 11 kW centrifugal pump → ATV310HU75N4A (ND=11 kW)

Kategorie 2: General Conveyors, Belt Lines, Roller Tables (Konstantes Drehmoment, Intermittent Start-Stop, HD Preferred)

Load characteristics: Konstantes Drehmoment, moderate starting resistance, häufiges Start-Stopp, occasional material jam shock

Selection rule: Strictly select by HD rating, motor rated current ≤ VFD HD current

Zubehör:

Long deceleration, high inertia belt: add braking resistor

Multi-speed control uses built-in DI terminals directly, no expansion card required

Einschränkung: High-speed positioning, high-precision synchronization not suitable for ATV310, use ATV320 instead

Beispiel: 7.5 kW belt conveyor → ATV310HU75N4A (HD=7.5 kW)

Kategorie 3: Mixing Tanks, Mixer (High Starting Torque, Schwere Ladung)

Load characteristics: Hohes Anlaufdrehmoment, high resistance from tank media, high stall risk, konstantes Drehmoment

Selection rule: HD selection, reserve 1.1~1.2 safety margin; motor rated current ≤ 90% of VFD HD current

Zubehör: Braking resistor for emergency stop; motor auto-tune recommended

High viscosity mixing: select one power size up

Beispiel: 5.5 kW mixing motor → Prefer ATV310HU75N4 (HD 7.5 kW) for margin

Kategorie 4: Screw Pumps, Gear Pumps, Positive Displacement Pumps (Konstantes Drehmoment)

Load characteristics: Medium starting torque, pressure fluctuation, dry running prohibited

Selection rule: HD for normal operation; upsizing for heavy pressure fluctuation & häufiges Start-Stopp

Zubehör: PID-Konstantdruck, add pressure feedback AI

Beispiel: 4 kW screw pump → ATV310HU40N4 (HD 4 kW)

Kategorie 5: Holzbearbeitungsmaschinen, Grinders, General Machine Tool Spindles (Continuous Constant Torque)

Load characteristics: Continuous cutting, load fluctuation, stable torque requirement

Selection rule: HD selection; upsizing for heavy cutting shock

❌ Not applicable: Spindle positioning, rigid tapping, closed-loop control → ATV310 has no encoder support, use ATV320

Kategorie 6: Heben, Hoist, Winch, Hydraulic Main Pump ( ATV310 NOT Recommended)

Wichtige Warnung: ATV310 is economical open-loop vector VFD, no brake logic, no torque verification, no safety functions. NOT allowed for lifting applications. Hoisting duty requires ATV320 + safety relay or dedicated hoist VFD.

Kategorie 7: Kühlturmventilatoren, Roof Fans, Exhaust Fans (Light Load Quadratic Torque)

Auswahl: ND rating, best cost performance

Notiz: Ambient temperature below -10 °C requires cabinet heater, VFD derating applies

Cabinet for outdoor installation prefers A version built-in EMC to avoid interference

Kategorie 8: Multi-motor Parallel Drive (Synchronous drag, multiple small motors)

Auswahl: Sum of all motor rated currents matched against HD current; motor auto-tune must be disabled, run in V/F mode

Zubehör: Fit thermal relay for each motor for individual overload protection; output reactor recommended

  1. Suffix A / E Selection Judgment (EMV)
  2. ATV310…N4A (Eingebauter EMV-Filter)

Geeignet: EU CE export, control cabinet close to sensors, Instrumente, PLC communication cables, high EMC requirement

  1. ATV310…N4E (No Built-in EMC Filter)

Geeignet: Standard domestic factory, power cables separated from signal wires, project procures separate external EMC filter; niedrigerer Preis

Risiko: Direct operation may interfere with sensors, weighing instruments, RS485-Kommunikation

  1. Ambient Derating Rules

Ambient temperature 45~55 °C: HD rating no derating; >55 °C derating mandatory

Höhe >1000 M: herabsetzen 4% pro zusätzlich 1000 M; ATV310 not recommended above 2000 M

Staub, ätzendes Gas: Enclosed cabinet + air conditioning required; standard ATV310 is 3C3 coated

  1. When to Upgrade from ATV310 to ATV320

Select ATV320 if any condition below applies:

  1. Encoder closed-loop control, high precision speed / Positionierung / synchronization required
  2. Safe torque off STO safety function required
  3. Multiple expansion cards needed (encoder card, Profinet/EtherNet/IP Ethernet card)
  4. Heben, Aufzug, hoist loads
  5. Severe dynamic shock, fast torque response required
  6. Übersichtstabelle zur Schnellauswahl
AnwendungstypTorque CharacteristicRecommended RatingEmpfohlenes SuffixBraking Resistor Suggested
Radialventilator / PumpeQuadratic TorqueNDA (Export) / E (Inländisch)NEIN
Belt Conveyor, Roller TableKonstantes DrehmomentHDA / EYes for high inertia
Mischen, High Viscosity BlendingKonstantes Drehmoment, High Starting TorqueHD + Upsize One StepAYes for emergency stop
Positive Displacement Pump (Screw Pump)Konstantes DrehmomentHDA / EOptional
General Machine Tool SpindleConstant Torque with FluctuationHDANEIN
Multi-motor Parallel V/F DriveCombinedTotal Current Match HDAOptional

Vorher:

Nächste:

Hinterlassen Sie eine Antwort