Erklärung des Modellcodes
| Codesegment | Bedeutung | Detaillierte Beschreibung |
| LC1 | Kennung der Produktserie | Basic code for Schneider TeSys contactors |
| D | Seriencode | TeSys Deca-Serie, high-performance full-range industrial contactors |
| 25 | Nennstrom | 25A (rated operational current under AC-3 utilization category) |
| 6 | Coil characteristic | Low-power consumption coil (<2.4W), energy-saving design |
| B | Spulenspannung | 24V |
| L | Spulentyp | Gleichstromspule |
| Full Description | Three-pole contactor of Schneider TeSys Deca series, rated current 25A, 24VDC low-power coil, ring terminal connection, 1Hilfskontakte NO+1NC |
- Wichtigste technische Spezifikationen
| Kategorie | Technische Daten | Bemerkungen |
| Grundparameter | ||
| Produkttyp | 3-pole non-reversible contactor | 3 main NO contacts |
| Nennstrom (AC-3) | 25A bei 400 V | For controlling 11kW three-phase motors |
| Nennstrom (AC-1) | 40A bei 400 V | Für ohmsche Lasten |
| Nennbetriebsspannung | Max. 690VAC / Max. 300VDC | |
| Coil Specification | 24VDC, Geringe Leistung (≤2.4W) | Anzugsspannung: 19.2-30VDC |
| Mechanisch & Elektrische Ausdauer | ||
| Mechanisches Leben | 15,000,000 Zyklen (keine Ladung) | |
| Elektrisches Leben (AC-3) | 1,600,000 Zyklen (with load) | |
| Physical Features | ||
| Montageart | Standardmäßige 35-mm-DIN-Schienenmontage | |
| Verbindungstyp | Ring-lugs | For firm wiring |
| Hilfskontakte | 1NO+1NC (Standard) | Erweiterbar |
| Abmessungen (mm) | Ca. 45×85×101 | Kompakte Größe, spart Platz im Schrank |
| Zertifizierungen & Standards | IEC 60947-4-1, IN 60947-4-1, RoHS-konform | Comply with international industrial standards |
| Betriebsumgebung | ||
| Betriebstemperatur | -25°C ~ +70°C | Wide temperature range for harsh industrial environments |
| Lagertemperatur | -40°C ~ +85°C | |
| Schutz vor Eindringen | IP20 (Haupteinheit) | Use with qualified protective enclosures |
- Full Model List (LC1D Series, 25A Range)
| Modell | Spulenspannung | Coil Type | Spulenstromverbrauch | Hilfskontakte | Referenz-Bestellnr. |
| LC1D256BL | 24VDC | Gleichstrom | Geringe Leistung (<2.4W) | 1NO+1NC | LC1D256BL |
| LC1D256B7 | 24VAC | Wechselstrom | Geringe Leistung | 1NO+1NC | LC1D256B7 |
| LC1D2501BL | 24VDC | Gleichstrom | Standard power | 1NO+1NC | LC1D2501BL |
| LC1D2501B7 | 24VAC | Wechselstrom | Standard power | 1NO+1NC | LC1D2501B7 |
| LC1D2510BL | 24VDC | Gleichstrom | Standard power | 1NC+1NO | LC1D2510BL |
| LC1D2510B7 | 24VAC | Wechselstrom | Standard power | 1NC+1NO | LC1D2510B7 |
| LC1D25BD | 24VDC | Gleichstrom | Standard power | 1NO+1NC | LC1D25BD |
| LC1D25M7 | 220VAC | Wechselstrom | Standard power | 1NO+1NC | LC1D25M7 |
| LC1D25Q7 | 380VAC | Wechselstrom | Standard power | 1NO+1NC | LC1D25Q7 |
| LC1DT256BL | 24VDC | Gleichstrom | Geringe Leistung | 1NO+1NC (4-Pole) | LC1DT256BL |
- Cross-brand & Old/New Model Replacement List
4.1 In-brand Replacement (Schneider)
| Originalmodell | Ersatzmodell | Beschreibung |
| LC1D25BD | LC1D256BL | Upgraded to low-power coil, 24VDC retained with improved performance |
| LC1D25B7 | LC1D256B7 | Low-power AC coil version |
| LC1D2500BL | LC1D256BL | Optimized auxiliary contacts (1NO+1NC replaces 0NO+0NC) |
4.2 Markenübergreifender Ersatz
| Original Brand | Originalmodell | Schneider Equivalent | Passende Ebene | Bemerkungen |
| ABB | A26-30-10 | LC1D256BL | ★★★★★ | 3-Pol 25A, 24V-Spule, identical specifications |
| Siemens | 3RT6026-1AN20 | LC1D256BL | ★★★★☆ | 25A, 24VDC, same auxiliary contact configuration |
| Omron | GMC-25 | LC1D256BL | ★★★★☆ | 3-Pol 25A, 24VDC, equivalent mechanical life |
| Mitsubishi | S-N25 | LC1D256BL | ★★★★☆ | 3-Pol 25A, low-power 24VDC coil |
- Anwendungsumgebung & Branchenfälle
5.1 Empfohlene Anwendungen
Industrielle Automatisierung: Control of three-phase asynchronous motors (Fans, Wasserpumpen, Kompressoren, Förderer)
HVAC-Systeme: Air conditioning compressors and ventilation systems
Gebäudeelektrik: Gebäudeautomation, lighting systems and fire-fighting equipment
Energy Industry: Power generation equipment, power distribution systems and renewable energy facilities
Wasseraufbereitung: Water pump control and wastewater treatment equipment
Marine & Eisenbahn: Transportation industry requiring special certifications (LC1D series advantages)
5.2 Not Recommended Applications
High-frequency switching: Über 1200 Operationen pro Stunde (Select LC1Q / LC1R series instead)
High altitude: Elevation over 2000m (Derate load or use special models)
Corrosive environments: Direct exposure to acid, alkali and salt mist (Additional protection required)
Explosionsgeschützte Bereiche: Special explosion-proof certified models are mandatory
5.3 Typische Anwendungsfälle
- Automobile Manufacturing Plant
Used for motor control of stamping production lines. Nach dem Austausch, breaking time is reduced by 30%, failure rate drops by 50%, maintenance time is shortened from 2 hours to 30 Minuten, and annual maintenance cost is cut by about 200,000 RMB.
- Essen & Getränkeindustrie
Applied to three-phase motors of filling lines. Thanks to 2.4W low power consumption, each contactor saves approximately 18 kWh per year under 24-hour continuous operation. A factory with 100 units saves 1,800 kWh annually.
- Rechenzentrum
Controls air conditioning compressors and ventilation fans. The 24VDC low-power coil ensures stable operation under UPS power supply, reduces battery load and extends backup duration.
- Auswahlrichtlinien & Quick Reference Rules
Quick Selection Tips
This is a 3-pole 25A contactor with 24VDC low-power coil and ring terminals. Equipped with 1NO+1NC auxiliary contacts, it features energy efficiency, high reliability and long service life, ideal for motors, water pumps and compressors.
Quick Reference Rules
- Aktuelle Übereinstimmung: 25A under AC-3 for 11kW three-phase motors; 40A capacity for resistive loads under AC-1.
- Coil Identification: Suffix BL = 24VDC low power; B7 = 24VAC low power; BD = 24VDC standard power.
- Hilfskontakte: Standard 1NO+1NC. Models with suffix 01 oder 10 for alternative contact configurations.
- Installation: Standardmäßige 35-mm-DIN-Schienenmontage; ring terminals ensure reliable connection.
- Energieeinsparung: Low-power coil (≤2.4W) saves 70% energy compared with standard coil (ca. 8W), perfect for long-term operation.
- Häufige Fehler & Fehlerbehebung
| Fehlerphänomen | Mögliche Ursachen | Lösungen |
| Schütz zieht nicht an | Insufficient coil voltage / Falsche Verkabelung | Check power voltage (19.2-30VDC) and wiring |
| Verbrannte Spule | Überspannung / Umgekehrte Polarität | Confirm 24VDC polarity; install overvoltage protection |
| Overheated contacts | Überlast / Lose Verkabelung | Check load current and retighten terminals |
| Welded contacts | Überlast / Kurzschluss | Inspect circuit protection devices and replace contact assembly |
| Übermäßiger Lärm | Dirty core contact surface | Clean core surface and check short-circuit ring |
- Key Ordering Information
Standardmodell: LC1D256BL
Alternative Modelle: LC1D25BD (standard power version), LC1D256B7 (24VAC low-power version)
Compatible Accessories:
Auxiliary contact blocks: LADN-Serie (z.B. LADN20C: 2NEIN; LADN02C: 2NC)
Overload relays: LRD-Serie (z.B. LRD08C: 6-10A, matches 25A contactor)
Mounting base: Optional separate base
Application Scenarios for LC1D256BL
Core features: 3-Pol 25A, 24VDC low-power coil, lange lebensdauer, standard DIN rail mounting, 1Hilfskontakte NO+1NC, strong anti-interference performance.
- Empfohlene Anwendungsszenarien (Hauptanwendungen)
Featured with 24VDC low-power DC coil, this model perfectly matches standard industrial DC control circuits. Its 25A rating is suitable for three-phase motors up to 11kW and resistive loads up to 40A, serving as a mainstream component for automatic control cabinets.
1.1 Industrielle Automatisierungsausrüstung (Kernanwendung)
Anwendbare Ausrüstung
PLC/DCS control cabinets, small machine tools, manipulator auxiliary mechanisms, inverter-driven fans, small drive motors, test and inspection equipment.
Vorteile
24VDC is the mainstream control voltage for industrial control systems, no extra power converter required.
DC coil provides strong EMC performance, avoiding misoperation caused by inverters and servos.
Geringe Leistung (≤2.4W) generates little heat during continuous power-on, geeignet für 24/7 standby equipment.
1.2 HVAC & Air Ventilation Systems
Anwendbare Ausrüstung
Drinnen & outdoor unit fans of central air conditioners, Kondensatpumpen, cooling tower fans, fresh air handling units, damper drive motors, machine room exhaust fans.
Vorteile
HVAC rooms widely adopt 24VDC automatic control circuits for high compatibility.
Low power design reduces energy consumption and cabinet temperature for year-round continuous operation.
Betriebstemperaturbereich: -25°C ~ +70°C, adapts to drastic temperature changes in machine rooms.
1.3 Gebäudeelektrik & Fire Emergency Systems
Anwendbare Ausrüstung
Domestic water pumps, basement exhaust fans, fire smoke exhaust fans, fire roller shutter motors, centralized emergency lighting circuits (ohmsche Lasten).
Vorteile
Standard 24VDC for fire emergency circuits, directly powered by UPS/emergency batteries for normal operation during power failure.
Built-in 1NO+1NC auxiliary contacts transmit operation/fault signals to fire alarm hosts and building monitoring systems.
40A load capacity under AC-1 for multi-circuit lighting control.
1.4 Wasseraufbereitungsindustrie (Sewage / Purified Water / Circulating Water)
Anwendbare Ausrüstung
Circulating water pumps, dosing metering pumps, aeration fans, small agitator motors, ventilation equipment for water treatment workshops.
Vorteile
Almost all automatic control systems for water treatment use 24VDC.
IP20 protection rating adapts to slightly humid indoor machine rooms.
Satisfactory electrical endurance for frequent start-stop operation with low failure rate.
1.5 Neue Energie, PV & Energy Storage Cabinets
Anwendbare Ausrüstung
Cooling fans for PV boxes, temperature control pumps for battery compartments, ventilation motors of energy storage cabinets, small auxiliary inverter loads.
Vorteile
PV and energy storage systems are DC-powered inherently; no inverter needed for 24VDC coil.
Ultra-low coil power avoids extra consumption of backup battery power and extends backup time.
No AC humming for DC coil, ideal for quiet energy storage rooms.
1.6 Logistik, Lagerung & Conveyor Lines
Anwendbare Ausrüstung
Bandförderer, roller sorting lines, small elevators, warehouse ventilation fans.
Vorteile
Mechanical and electrical endurance meets frequent regular start-stop for long-running production lines.
Auxiliary contacts realize interlock, chain control and sequence start to ensure safety logic of production lines.
1.7 Essen, Verpackung & Light Industrial Equipment
Anwendbare Ausrüstung
Conveyors of packaging machines, auxiliary motors of filling lines, dehumidifiers and ventilation fans for workshops.
Vorteile
Suitable for clean indoor workshops without heavy corrosion; standard rail mounting facilitates standardized cabinet wiring.
Compact structure saves cabinet space, a standard OEM component for complete machines.
- Nicht empfohlen / Verbotene Szenarien (Risks & Alternativen)
2.1 High-frequency Start-Stop (Über 1200 Zyklen pro Stunde)
Risiko: Excessive switching frequency causes rapid contact ablation, welding and shortened service life.
Alternative: Schneider LC1R / LC1R series high-frequency contactors.
2.2 Höhe über 2000m
Risiko: Thin air degrades arc extinction capability, leading to arcing and reduced insulation performance.
Empfehlung: Use special high-altitude contactors or derate the load by over 30%.
2.3 Severe Corrosion, Salt Spray & Heavy Dust (Chemical Plants, Coastal Open Areas, Mines)
Risiko: IP20 rating cannot protect coil, terminals and contacts from acid, alkali, salt mist and dust erosion.
Erfordernis: Bare installation is forbidden. Use sealed enclosures of IP54 or higher; select anti-corrosion models for chemical environments.
2.4 Direct Outdoor Installation without Protection
Risiko: Rain, sunlight and condensation lead to coil short circuit and contact oxidation.
Mandatory Requirement: Install inside distribution cabinets or control enclosures with IP54 or higher protection.
2.5 High-power Pure DC Main Circuit Loads
Risiko: Designed mainly for AC loads with poor DC breaking capacity; high DC loads easily cause contact welding.
Alternative: Schneider LP1D dedicated DC contactors.
2.6 AC220V / AC380V Control Circuits
Risiko: 24VDC coil will burn out instantly if connected to AC power.
Alternative AC coil models:
24VAC: LC1D256B7
220VAC: LC1D25M7
380VAC: LC1D25Q7
2.7 Control Three-phase 380V Motors over 11kW (AC-3)
Risiko: Rated 25A under AC-3 corresponds to 11kW motor; overload results in overheating and burnt contacts.
Alternative: Upgrade to higher current models such as LC1D32 series.
- Notes for Marginal Operating Conditions (Usable with Protection Measures)
- Basements & Humid Machine Rooms
The product is applicable. Install dehumidifiers inside control cabinets to prevent condensation inside the contactor.
- Ambient Temperature near Limits (-25°C / +70°C)
Derate the load by 10% and avoid long-term full-load operation.
- Coil Wiring Length over 10m
Voltage drop occurs on 24VDC lines. Ensure terminal voltage of the contactor coil is no lower than 19.2V (minimum pull-in voltage).
- Control Inductive Loads such as Motors
Equip with surge suppressors (Schneider LADRC series) to absorb back EMF and protect the coil.
- Scenario Summary
✅ Preferred Applications: Indoor control cabinets, 24VDC control systems, three-phase motors up to 11kW, 24/7 continuous-operation equipment (Automation, HVAC, Fire Protection, Wasseraufbereitung, Energiespeicher).
❌ Avoid: High-frequency switching, große Höhe, unprotected outdoor areas, heavily corrosive environments, high-power DC main circuits, AC control power supply.
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien