Schütz/

Schneider LC1D38BLDC24V Contactor

Schneider LC1D38BLDC24V TeSys D Series Contactor with DC Coil The Schneider LC1D38BLDC24V is a low-consumption DC coil contactor of the TeSys D Series. Featuring a rated current of 38A, 24V low-power DC coil, 3NO+1NO+1NC contact configuration and a compact 45mm width design, it is an ideal choice for industrial automation. Its advantages of energy efficiency, ...

  • Produktdetails

Schneider LC1D38BLDC24V TeSys D Series Schütz with DC Coil

The Schneider LC1D38BLDC24V is a low-consumption DC coil contactor of the TeSys D Series. Featuring a rated current of 38A, 24V low-power DC coil, 3NO+1NO+1NC contact configuration and a compact 45mm width design, it is an ideal choice for industrial automation. Its advantages of energy efficiency, high reliability and flexible installation make it widely applied in motor control, PLC systems, Fans, water pumps and other facilities. For selection, comprehensively consider load type, Steuerspannung, installation space and energy consumption requirements. Routine maintenance is also required to ensure optimal performance and extended service life.

This is a three-pole AC contactor of Schneider TeSys D Series, rated at 38A and equipped with a 24V low-consumption DC coil. It has 3 main NO contacts plus 1 NEIN und 1 NC auxiliary contacts, and is applicable for controlling 18.5kW motors (AC-3, 440V). With a width of 45mm and support for DIN rail mounting, it is typically used in industrial automation, motor control and PLC systems.

  1. Erklärung des Modellcodes
CodesegmentBedeutungBeschreibung
LC1Series PrefixIdentifier for Schneider TeSys contactors; LC1 stands for three-pole contactor
DUnterserieTeSys D-Serie, general-purpose industrial contactor with 45mm width for standard applications
38NennstromRated operational current of main contacts: 38A (AC-3, 440V)
BSpulenspannung24V (B=24V, C=36V, E=48V, F=110V, M=220V, P=230V, U=240V, usw.)
LCoil TypeLow consumption coil, power consumption reduced by about 50% compared with standard coils
GleichstromCoil Power SupplyDirect current coil, distinguished from AC coils
24VSpulenspannungExplicit rated voltage: 24In DC
-XXXSuffix CodeOptional configurations including auxiliary contacts (z.B. 3BL = 3NO+1NO+1NC) and terminal types
  1. Main Specifications
ArtikelWertBemerkungen
MarkeSchneider ElectricWorld-renowned electrical equipment manufacturer
SerieTeSys D (LC1D)General-purpose industrial contactor with high cost performance
TypThree-pole AC contactor with low-consumption DC coilNon-reversing type, for motor start and stop control
Hauptkontaktkonfiguration3NEIN (3 Normalerweise geöffnet)Standard design for three-phase circuit control
Hilfskontaktkonfiguration1NO+1NC (1 Normalerweise geöffnet + 1 Normalerweise geschlossen)Built-in auxiliary contacts for control circuits
Nennstrom38A (AC-3, 440V)Rated current for motor loads
Nennbetriebsspannung≤690 V Wechselstrom (25~400Hz), ≤300V DCMaximum voltage of main circuit
Spulenspannung24In DCControl circuit voltage; Operating range: 20.4~26,4 V Gleichstrom
SpulenstromverbrauchPull-in: 18W, Halten: 2.5WLow-power design for energy saving and less heat generation
Nennleistung18.5kW (AC-3, 440V, 50Hz)Maximum power of controllable motor
Mechanische Ausdauer10,000,000 OperationenHigh-reliability construction
Elektrische Ausdauer1,000,000 Operationen (under rated AC-3 conditions)Konform mit IEC 60947-4-1
MontagemethodeDIN-Schienenmontage (IN 50022) or screw mountingFlexible installation for control cabinet layout
Breite45mmStandard width to save cabinet space
TerminalsEverlink hexagon socket screw terminalsFirm connection with anti-loosening design
Schutz vor EindringenIP20 (main body)Suitable for indoor control cabinets
ZertifizierungenIEC 60947-4-1, UL, CSA, CEKonform mit internationalen Sicherheitsstandards
FarbeSchwarzStandard industrial color
GewichtCa. 420GLeicht für einfache Installation
  1. Markenübergreifende Kompatibilität & Ersatz
MarkeÄquivalentes ModellSpezifikationenErsatzempfehlung
SchneiderLC1D38BD38A, 24V DC standard coil, 3NO+1NO+1NCStandard power version; coil pull-in 28W, holding 4W, niedrigerer Preis
SchneiderLC1D38BNE38A, 24V AC/DC universal coil, 3NEINUniversal AC/DC coil, ideal for unstable power supply
ABBA145-30-1138A, 24V DC-Spule, 3NO+1NO+1NCSimilar size and performance, Direkter Ersatz verfügbar
Siemens3RT2026-1BB4038A, 24V DC-Spule, 3NO+1NO+1NCGerman brand with reliable quality, höherer Preis
OmronGMC-3838A, 24V DC-Spule, 3NO+1NO+1NCJapanese brand with fast response, for precision control
CHINTCJX2-3810Z38A, 24V DC-Spule, 3NO+1NOInländische Alternative, cost-effective and stable performance
Changshu-SchalterCK3-3838A, 24V DC-Spule, 3NO+1NO+1NCBekannte inländische Marke mit hohem Preis-Leistungs-Verhältnis
  1. Full Model List of LC1D38 Series
ModellCoil TypeSpulenspannungHauptkontakteHilfskontakteMerkmaleBestell-Nr.
LC1D38BLDC24VLow-consumption DC24In DC3NEIN1NO+1NCEnergy-saving design, geeignet für den LangzeitbetriebLC1D38BL
LC1D38BDDC24VStandard DC24In DC3NEIN1NO+1NCStandard power, economical priceLC1D38BD
LC1D38B7AC24VStandard AC24V und3NEIN1NO+1NCAC coil, for traditional control circuitsLC1D38B7
LC1D38BLAC24VLow-consumption AC24V und3NEIN1NO+1NCLow-power AC type, energiesparendLC1D38BL
LC1D383BLDC24VLow-consumption DC24In DC3NEIN3NO+1NCMultiple auxiliary contacts, for complex controlLC1D383BL
LC1D38BDC24VStandard DC24In DC3NEINNo auxiliary contactsGrundmodell, for simple controlLC1D38BDC
LC1D38KUEDC24VUniversal coil24In DC3NEIN1NO+1NCGroßer Spannungsbereich, adapts to power fluctuationLC1D38KUE
LC1D38BLDC48VLow-consumption DC48In DC3NEIN1NO+1NCDedicated for 48V systemsLC1D38BL
  1. Anwendungsumgebung & Auswahlhilfe

Empfohlene Anwendungen

Industrielle Motorsteuerung: Start, stop and forward/reverse control of three-phase asynchronous motors (≤18.5kW)

SPS-Steuerungssysteme: Act as output actuators of PLC to control various loads

Lüfter & Wasserpumpensteuerung: HVAC-Systeme, industrial cooling systems, water treatment equipment

Kompressorsteuerung: Air compressors, refrigeration compressors, usw.

Förderer & Production Lines: Power control for automated production lines

Werkzeugmaschinen: Motor control for CNC machine tools, Fräsmaschinen, grinders and other equipment

Erneuerbare Energie: Auxiliary control for photovoltaic inverters and wind power systems

Not Recommended Applications

High-frequency Start-Stop: Über 10 operations per minute; special contactors are recommended

Flammable & Explosive Areas: No explosion-proof certification, not applicable for chemical, mining and other hazardous sites

Unprotected Outdoor Use: IP20 rating provides limited protection against dust and moisture

Extremely Low Temperature: Ambient temperature below -5℃ may affect coil pull-in performance

High-frequency Switching Devices: Such as electric welders and high-frequency power supplies; thyristors or solid state relays are preferred

Selection Rhythm

TeSys D-Serie, forty-five millimeters wide,

Thirty-eight amperes for loads to abide.

B stands for twenty-four volt supply,

L means low power, energy well applied.

DC for direct, AC for alternating flow,

Three NO main contacts where power will go.

One NO, one NC for control circuit use,

Most common choice for motor crews.

DIN rail mount saves cabinet space,

Used widely in every industrial place.

  1. Häufige Fehler & Fehlerbehebung
FehlerphänomenMögliche UrsachenSchritte zur FehlerbehebungLösungen
Schütz zieht nicht an1. Low or no control voltage1. Measure coil voltage (normal range: 20.4~26,4V)1. Stabilize control voltage
2. Durchgebrannte Spule2. Spulenwiderstand testen (normal value: ca. 17)2. Replace with identical contactor
3. Mechanische Blockierung3. Manually toggle the contactor to check flexibility3. Remove foreign objects or replace contactor
4. Open circuit in control loop4. Inspect wiring and components of control loop4. Repair control circuit
Contactor drops out after pull-in1. Unstable control voltage1. Measure coil voltage during operation1. Install voltage stabilizer
2. Poor coil connection2. Check loose coil terminals2. Fasten wiring terminals
3. Voltage drop caused by overloaded load3. Detect power voltage fluctuation3. Use thicker cables or reduce load
4. Faulty auxiliary contacts4. Inspect contact condition of auxiliary contacts4. Replace auxiliary contact module
Überhitzung / arcing on contacts1. Load current exceeds rated value1. Measure actual load current1. Replace contactor with higher rating
2. Schlechte Kontaktleistung2. Check oxidation or ablation on contact surfaces2. Clean contacts or replace contactor
3. Frequent start-stop operations3. Count start-stop frequency3. Optimize control logic to reduce switching times
4. Zu hohe Umgebungstemperatur4. Measure ambient temperature4. Add heat dissipation measures
Excessive operating noise1. Oil or dust on iron core surface1. Clean iron core surface1. Wipe and clean iron core
2. Broken shading ring2. Check integrity of shading ring2. Replace contactor
3. Loose installation3. Befestigungsschrauben festziehen3. Fasten all fixing screws
4. Low supply voltage4. Measure coil voltage4. Stabilize power supply voltage
Overheated coil1. Überspannung1. Check if coil voltage exceeds 26.4V1. Lower control voltage
2. Coil aging2. Check coil for discoloration2. Replace contactor
3. Hohe Umgebungstemperatur3. Measure ambient temperature3. Verbessern Sie die Wärmeableitung
4. Continuous energization4. Verify long-term energization requirements4. Adopt pulse control mode
  1. Industrial Application Cases

Fall 1: Fan Control Renovation in Textile Factory

Traditional contactors in a textile factory suffered frequent burnout, coil overheating and high power consumption. The original AC standard-power contactors controlled 3 sets of 15kW fans.

Lösung: Replaced with Schneider LC1D38BLDC24V contactors featuring low-consumption DC coils, combined with PLC for soft start and variable frequency speed regulation.

Ergebnis: Coil temperature decreased by 25%, power consumption cut by 50%, service life extended to 5 Jahre. Annual electricity cost saved about 8,000 RMB and failure rate reduced by 90%.

Fall 2: Motor Control for Automated Production Line

Multiple 38A motors were used on an auto parts production line. Low-quality generic contactors caused frequent line shutdowns due to poor reliability.

Lösung: Fully replaced with LC1D38BLDC24V contactors to unify control standards, and matched with Schneider PLC for centralized control and fault diagnosis.

Ergebnis: Line downtime reduced by 85%, Wartungskosten um reduziert 70% and production efficiency improved by 15%. The low-power design lowered cabinet temperature and prolonged service life of other electrical components.

Fall 3: Air Conditioning Control in Data Center

Multiple 18.5kW compressors were equipped in a large data center air conditioning system. The original AC coil contactors often failed to pull in under UPS power supply mode.

Lösung: Switched to LC1D38BLDC24V DC coil contactors which adapt to DC output of UPS. The low-power design also reduced UPS load.

Ergebnis: Stable pull-in performance under UPS mode with zero faults. UPS load decreased by 30%, battery service life extended and maintenance frequency of air conditioning system reduced.