 Siemens 3RV1901-1A seitlich montierter Hilfskontakt - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Schütz/

Siemens 3RV1901-1A seitlich montierter Hilfskontakt

Vollständiger Produktname: SIRIUS Classic side-mounted auxiliary contact (lateral auxiliary switch) Suitable for legacy 3RV1 motor protection circuit breakers, frame sizes S00 / S0 / S2 / S3; Schraubklemme, 1NO+1NC (1 normalerweise offen + 1 normalerweise geschlossen) Lebenszyklus: Veraltet (Ausstieg). It is an accessory for the older 3RV1 platform; the manufacturer promotes the upgraded ...

  • Produktdetails

Vollständiger Produktname: SIRIUS Classic side-mounted Hilfs- Kontakt (lateral auxiliary switch)

Suitable for legacy 3RV1 motor protection circuit breakers, frame sizes S00 / S0 / S2 / S3; Schraubklemme, 1NO+1NC (1 normalerweise offen + 1 normalerweise geschlossen)

Lebenszyklus: Veraltet (Ausstieg). It is an accessory for the older 3RV1 platform; the manufacturer promotes the upgraded 3RV2 platform.

Wichtige Spezifikationen

Kontaktkonfiguration: 1NEIN + 1NC

Montage: Lateral side mounting (distinguished from front-mounted 3RV1901-1E)

Verdrahtung: Schraubklemmenklemmen

Kontaktbewertung: AC-12, max. 6A / 240V und; commonly used for 24VAC/DC, 220VAC signal feedback in control circuits

Schutz: IP20

Anwendung: Passive feedback of circuit breaker ON/OFF status for PLC, indicator lamps and circuit interlocks

Compatible breaker bodies: 3RV10, 3RV11, 3RV13, 3RV14, 3RV16 and other legacy 3RV1 motor protectors; not directly compatible with the new 3RV2 series

Erklärung des Modellcodes

3RV1: Legacy SIRIUS motor protection circuit breaker series

3RV19: Accessory group for the 3RV1 series

01: Hilfsschalter

1A: Lateral mounting, 1NO+1NC, Schraubklemmen

Ersatzoptionen (Wichtig)

  1. If migrating to 3RV2 circuit breakers: Front auxiliary contact 3RV2901-1E (1NO+1NC, schrauben); lateral type 3RV2901-2E (2NO+2NC)
  2. If keeping the existing 3RV1 breaker body: Nur Lagerware / second-hand 3RV1901-1A is available; 3RV29xx accessories cannot be fitted onto legacy 3RV1 breakers
  3. Other accessories of the same series for reference:

3RV1901-1E: Front-mounted auxiliary contact, 1NO+1NC

3RV1901-1J: Lateral, 2NEIN

3RV1901-1C: Lateral, 2NC

Full Accessory List for Siemens 3RV1 (Legacy SIRIUS Motor Protection CB)

Compatible bodies: 3RV10 / 3RV11 / 3RV13 / 3RV14 / 3RV16; frame S00, S0, S2, S3; entire series obsolete. Accessories fit only 3RV1 bodies and cannot be installed on 3RV2

Terminal distinction: -1xxx = screw terminals; -2xxx = spring-cage terminals

  1. Hilfskontakte (Status feedback, reflects CB ON/OFF position)
Bestell-Nr.MontagepositionKontaktkonfigurationBemerkungen
3RV1901-1ALateral1NO+1NCModel hat nachgefragt, Schraubklemme
3RV1901-1BLateral2NO+2NCSchrauben
3RV1901-1CLateral2NCSchrauben
3RV1901-1JLateral2NEINSchrauben
3RV1901-2ALateral1NO+1NCFederkäfig
3RV1901-2BLateral2NO+2NCFederkäfig
3RV1901-2CLateral2NCFederkäfig
3RV1901-1EFront (quer)1NO+1NCSchrauben, most common front type
3RV1901-1FFront2NEINSchrauben
3RV1901-1DFront2NCSchrauben
3RV1901-1GFront1NO+1NCFor low-current / electronic circuits, dust-resistant
3RV1901-0HDust cover for front auxiliary contact—Protective cap, Packung mit 10

Einschränkung: Maximum one lateral auxiliary contact per 3RV1 breaker; vorne montiert + lateral can be used together.

  1. Fault Signal Switch (Trip signal, distinguishes overload / Kurzschluss, not equal to standard auxiliary contact)
Bestell-Nr.KontaktkonfigurationBemerkungen
3RV1921-1M1NO+1NCFault contact, actuates only on overload or short-circuit trip; no action during manual ON/OFF. For PLC fault alarm.
  1. Unterspannungsauslöser (UVT, trip on loss of supply)
Bestell-Nr.Spulenspannung
3RV1902-1AB0AC24V 50Hz
3RV1902-1AF0AC110V 50Hz
3RV1902-1AP0AC230V 50Hz
3RV1902-1DC0DC24V
  1. Arbeitsstromauslöser (SHT, Fernauslösung)
Bestell-Nr.Spulenspannung
3RV1903-1AB0AC24V
3RV1903-1AF0AC110V
3RV1903-1AP0AC230V
3RV1903-1DC0DC24V

Release rule: Undervoltage release and shunt release are mutually exclusive, cannot be fitted on the same breaker.

  1. Door-coupled Rotary Operating Mechanism (External cabinet operation, IP65, mit Vorhängeschloss abschließbar)
Bestell-Nr.SchaftlängeCompatible Frame
3RV1926-0B130mmS0 / S2 / S3
3RV1926-0K330mmS0 / S2 / S3

Funktion: Cabinet door cannot be opened when CB is closed; lockable in OFF position to prevent accidental closing.

  1. Busbar Modules (Main circuit interconnection for side-by-side mounting)

S00 / S0-Rahmen

Bestell-Nr.Zweck
3RV1915-1ABBusbar for 2 breakers
3RV1915-1BBBusbar for 3 breakers
3RV1915-1CBBusbar for 4 breakers
3RV1915-1DBBusbar for 5 breakers
3RV1915-3AB2 breakers (with space for accessories)
3RV1915-3BB3 breakers (with space for accessories)
3RV1915-3CB4 breakers (with space for accessories)

S2 Frame

Bestell-Nr.Zweck
3RV1935-1A2 breakers
3RV1935-1B3 breakers
3RV1935-1C4 breakers
3RV1935-3A2 breakers (with space for accessories)
  1. Contactor Link Module (Direct assembly for 3RV1+3RT1 starter group, no extra busbar)
Bestell-Nr.Compatible Assembly
3RA1941-1BMechanisch & electrical link for 3RV1.41 + 3RT1.4 starter combination
  1. Robben, Abdeckungen & Other Mechanical Accessories
Bestell-Nr.Beschreibung
3RV1920-1ASeal kit, prevents unauthorised adjustment of current setting dial
3RV1910-1AExtended terminal cover

Cross Reference for Migration to 3RV2 Platform

Legacy 3RV1 Part No.3RV2 Replacement
3RV1901-1A (Lateral 1NO+1NC, schrauben)3RV2901-1A
3RV1901-1E (Front 1NO+1NC, schrauben)3RV2901-1E
3RV1921-1M (Fault signal switch)3RV2921-1M

Hinweise zur Schlüsselauswahl

  1. Standard-Hilfskontakte (3RV1901): Only indicate handle position, cannot distinguish fault trip. Fault alarm requires 3RV1921-1M.
  2. Unterspannungsauslöser: The breaker must be closed before supply is restored; it trips automatically when supply fails. Arbeitsstromauslöser: Trips when energised.
  3. Busbars have two versions: standard and accessory-space type. If auxiliary contacts are fitted on the side, select suffix 3AB/3BB/3CB.
  4. Only stock items are available for purchase; manufacturer no longer accepts new production orders.

Operating Principle of 3RV1901-1A (Mechanically Synchronised Position Auxiliary Switch)

Kernzusammenfassung: Pure mechanical linkage, contact state follows the mechanical position of the 3RV1 handle synchronously. It only reflects ON / OFF status and cannot detect overload or short-circuit faults.

It is a passive snap-on auxiliary contact module clipped to the side of the 3RV1 motor protection circuit breaker. No electromagnetic components or trip detection mechanism inside.

  1. Mechanical Linkage Structure

The operating mechanism of the breaker handle and main contacts has a drive cam. Once 3RV1901-1A is fully engaged, its internal lever bears against this cam:

Handle movement → cam displacement → actuates internal rocker mechanism of auxiliary contact

Internal double-break silver bridge contact, ein Wechslerkontakt (CO:1NO+1NC) with snap-action spring to ensure clean switching without chatter.

Operating States

  1. Circuit Breaker ON

Handle switched to ON position, cam fully advanced: NEIN geschlossen, NC geöffnet

→ ON signal to PLC, run indicator lamp energised

  1. Circuit Breaker OFF (Manual opening)

Handle switched to OFF position, cam retracts: KEIN geöffnet, NC geschlossen

→ Stop status feedback

  1. Circuit Breaker Tripped by Overload / Short-Circuit

⚠️ Wichtig: Nach dem Stolpern, the handle rests in the intermediate trip position. The handle mechanism also drives the cam, so 3RV1901-1A switches to OFF state (KEIN geöffnet, NC geschlossen).

✅ Limitation: This contact alone cannot tell whether opening is manual or fault-induced.

👉 Separate fault alarm requires 3RV1921-1M (fault signal switch). It has an independent trip plunger and only switches state on overload/short-circuit trip; no action on manual ON/OFF.

  1. Elektrische Eigenschaften

Passiver Trockenkontakt, no internal power supply; it is simply a mechanical switch to route low-current signals for PLC digital inputs, lamps and interlock circuits.

Utilisation category AC-12: 6A / 240V und. Designed exclusively for control signal circuits, not permitted for main power circuits.

Contact timing: Switches nearly synchronously with the main breaker contacts, no advance or delayed action (slightly different from contactor auxiliary contacts).

  1. Comparison with 3RV1921-1M (Common Pitfall in Selection)
Teile-Nr.Actuation SourceDistinguish manual OFF vs fault tripAnwendung
3RV1901-1ACam from handle mechanism❌ Nein, same contact state for both casesPositionsrückmeldung, run indication, general interlock
3RV1921-1MIndependent plunger from thermal / magnetic trip unit✅ Ja, state changes only on fault tripStörungsalarm, fault logging, fault interlock shutdown
  1. Installation Constraints & Zusätzliche Hinweise

Lateral mounting. Maximum one lateral auxiliary contact (3RV1901-1A) per 3RV1 breaker; one front auxiliary contact (3RV1901-1E) may be added together.

Poor snap fit causes the internal lever to lose engagement with the cam: handle moves but auxiliary contact does not toggle (most frequent site fault).

Insulated housing separates high-voltage main circuit from signal contacts, meeting low-voltage isolation requirements.

Common Site Misconception

❌ Missverständnis: 3RV1901-1A is a fault contact and triggers alarm when tripped

✅ Korrektur: It is only a position contact. An open signal from this contact to PLC merely means the breaker is not closed. Combine it with 3RV1921-1M using AND/OR logic to discriminate fault trip.

Vorher: