Schneider LXM32MD72N4 Servo Drive - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

 Schneider LXM32MD72N4 Servo Drive - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

SPS/elektrisch/

Schneider LXM32MD72N4 Servo Drive

LXM32: Lexium32 series servo M: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function) D72: Peak output current 72A, continuous 24A N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply Core Electrical Specifications Item Specification Power Supply 3-phase AC 208~480V, 50/60Hz Rated Power 400V class: 7kW; 230V-Klasse: 5kW Continuous Output Current 24A (8kHz carrier ...

  • Produktdetails

LXM32: Lexium32 series servo

M: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function)

D72: Peak output current 72A, continuous 24A

N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply

Grundlegende elektrische Spezifikationen

ArtikelSpezifikation
Stromversorgung3-phase AC 208~480V, 50/60Hz
Nennleistung400V-Klasse: 7kW; 230V-Klasse: 5kW
Kontinuierlicher Ausgangsstrom24A (8kHz carrier frequency)
Spitzenausgangsstrom72A, sustainable for 5s
Eingebauter EMV-FilterStandard integrated
Speed Loop BandwidthUp to 1600Hz, hohe Dynamik
Trägerfrequenz8kHz
DC Bus Undervoltage Threshold350V (400V-Klasse)

Kommunikation & E/A

  1. Feldbus: CANopen (LXM32M model, different from pulse-type LXM32A)
  2. Digital: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; digitale Ausgänge
  3. Encoder-Schnittstelle: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
  4. Schnittstellen: RJ45 debug port, detachable color-coded terminals for convenient cabinet wiring and maintenance

Passende Motoren

Compatible with BSH / BMH 400V class Servomotoren of Lexium32 series. Typical match: 140-flange BSH high-torque motor, continuous torque up to 27.8N·m, peak 90.2N·m, common speed 3000rpm.

Anwendungsszenarien

Verpackungsmaschinen, machine tool feed axes, CNC cutting, Textilmaschinen, material handling conveying, multi-axis synchronization equipment; suitable for automated production lines requiring CANopen bus multi-axis linkage and high dynamic positioning.

Installation & Umfeld

Book-style cabinet mounting, vertical installation on control cabinet DIN rail

Überspannungskategorie: Class III

Max leakage current: 30mA

Recommended wire gauge for power terminals: 3mm², tightening torque 0.5N·m

Fehler & Hinweise zur Inbetriebnahme

  1. Allgemeine Alarme: Overcurrent OC, Overvoltage OV, Undervoltage UV, Encoder Fault, Overheat OH
  2. Inbetriebnahmesoftware: SoMove, supports online parameter configuration, oscilloscope sampling and automatic inertia tuning
  3. For high-power working conditions, it is recommended to install an external 1mH line reactor to reduce harmonics and incoming current surges

Ersatz & Selection Remarks

Pulse version of the same series: LXM32AD72N4 (no CANopen, pulse-direction control)

Upgrade-Alternative: Schneider Lexium28 series; comparable competitors: Siemens V90, Mitsubishi MR-J4

Notiz: LXM32 is a discontinued legacy series. Lexium28 is preferred for new projects; stock or second-hand units are available only for spare part projects.

HS-Code-Referenz

85011099 (Servoantrieb, re-verify customs classification before customs declaration)

LXM32MD72N4 SoMove Power-on Commissioning Parameter Template

Anwendbar: Lexium32M 7kW CANopen bus servo, matched with BSH/BMH 400V motors; SoMove software, expert mode password 696969

Pre-operation: Complete hardware wiring including power cable, Encoder, Not-Aus, Bremse, CAN bus and 24V control power supply; perform no-load jog test first, then auto-tune under load; save parameters to EEPROM after modification.

  1. Grundkonfiguration (Simply Start Wizard Page)
ParameternameParameter IDEmpfohlene EinstellungBeschreibung
Control SourceDEVcmdInterfFeldbusLXM32M CANopen positioning mode; temporarily change to Terminal for local jog
Motor SelectionMotor SelectionSelect corresponding BSH/BMH modelDrive loads motor nameplate parameters automatically; must not select incorrectly
EncodertypENC1_typeSinCos / EnDatSelect according to motor encoder; EnDat absolute encoder requires battery module
TrägerfrequenzPWM_Freq8kHzDefault for LXM32MD72N4, not recommended to increase
RotationsrichtungInvertDirOfMoveAUS (Standard)Set to ON if rotation direction reversed; power cycle required after change
Auto Enable on Power-upIO_AutoEnable0 (Disabled)Disabled during commissioning; can be set to 2 for mass production after safety assessment
  1. Axis Limit Parameters (Axis Configuration → Limitations)
ParameternameParameter IDEmpfohlene EinstellungBeschreibung
Maximaler AusgangsstromCTRL_I_maxMotornennstromLimit maximum torque to protect machinery; cannot exceed 72A peak of drive
Max Motor SpeedM_n_maxNenndrehzahl des MotorsTypical 3000rpm for BSH/BMH, do not exceed nameplate
Positive Software LimitPOS_LIM_PUser unitInside mechanical hard limit to prevent overtravel
Negative Software LimitPOS_LIM_NUser unitSame as positive limit
E-Stop DecelerationQS_DecBrauchDeceleration triggered by emergency stop, safety related
  1. E/A & Safety Parameters (Axis Configuration → IO)
ParameternameParameter IDEmpfohlene EinstellungBeschreibung
Positive Limit ContactIOsigLIMPNC, normalerweise geschlossenDefault for safety standards; set to NO if using normally open sensors
Negative Limit ContactIOsigLIMNNC, normalerweise geschlossenDas Gleiche wie oben
Brake Release DelayBRK_AddT_Release100MSBrake motor: wait for brake release before movement after servo enable
Brake Apply DelayBRK_AddT_Apply50MSDelay brake output after servo disable to prevent axis falling
Fehler-ResetIO_FaultResetAssign DI terminalExternal reset button
  1. Position Scaling (Skalierung, Core for Positioning Projects)

User units per revolution, Beispiel: 10mm per revolution for lead screw, modify as required

| Parametername | Parameter ID | Beispielwert | Beschreibung |

| —| —| —| —|

| Position Numerator | ScalePOSnum | 10 | Numerator of travel per revolution |

| Position Denominator | ScalePOSdenom | 1 | Denominator; Beispiel: 10mm/rev → 10/1 |

| Velocity Scaling | ScaleVELnum / ScaleVELdenom | Follow position | Velocity unit: mm/s |

| Acceleration Scaling | ScaleACCnum / ScaleACCdenom | Follow position | Acceleration unit: mm/s² |

Raw encoder resolution: 16384count/rev for SinCos motors

  1. Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)

Prioritize SoMove automatic inertia identification + auto-tune, then fine tune

| Parametername | Parameter ID | Initial Recommendation | Tuning Logic |

| —| —| —| —|

| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |

| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |

| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |

| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |

| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |

| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |

  1. CANopen Fieldbus Parameters (Key for LXM32M)
ParameternameParameter IDEmpfohlene EinstellungBeschreibung
CAN Node IDCAN_NodeID1~127No duplicate for multi-axis, consistent with PLC
CAN Baud RateCAN_Baud500kbit/sCommon setting; use 250kbps for long distance, terminal resistor ON at both bus ends
PDO MappingPDO ConfigurationStandard positioning PDOTarget position, Statuswort, actual position, fault code
Fieldbus Control ModeProfile ModeProfile PositionPositionierungskontrolle; select Profile Velocity for speed axis
Profile Acc/DecPRO_ACC / PRO_DECMechanical dependentEinheit: user unit/s
Quick Stop RampPRO_QSDecIndependent E-stop decelerationDeceleration upon bus failure
  1. Homing Parameters
ParameternameParameter IDBeschreibung
Homing ModeHOM_mode0~35 optional; gemeinsam: limit homing, index homing, direct origin setting for absolute encoder
Homing VelocityHOM_VelNiedrige Geschwindigkeit, 50~200 user unit/s
Homing Search VelocityHOM_Vel_SearchSlightly higher than homing speed
Homing OffsetHOM_OffsetMechanical origin offset
  1. Überwachung & Fault Log

Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults

Oszilloskop: Sample target position, actual position, following error, bus voltage, motor current for resonance and tuning analysis

Speichern: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file

Complete Power-on Commissioning Procedure (Matching Parameter Template)

  1. Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
  2. Run Simply Start wizard, select motor model and confirm encoder type
  3. Configure limit, brake and I/O terminal definition
  4. Set position scaling and mechanical transmission ratio
  5. Set CANopen Node ID, baud rate and configure PDO
  6. Leerlauftest: Aktivieren, joggen, Überprüfen Sie die Drehrichtung, limit and brake logic
  7. On-load test: Run Auto-tune inertia identification to generate base gains
  8. Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
  9. Homing-Test, point positioning test, acceleration/deceleration test
  10. Save parameters to EEPROM and export .cxm backup file

Commissioning Precautions

  1. Expert mode password 696969, enter expert mode to modify advanced parameters
  2. Auto-tune must be performed with actual load; parameters tuned under no-load easily oscillate under load
  3. Incorrect brake timing will directly cause axis falling; test brake function without load during first commissioning
  4. CANopen-Bus: Enable terminal resistor only at the first and last device on bus, disable for intermediate nodes
  5. For high-power LXM32MD72N4, check wiring of line reactor and braking resistor before first power-up

Optional Extended Parameters

Bremswiderstand: BRK_R, BRK_P for external braking resistor resistance/power rating, bus overvoltage protection

Analoger Eingang: AI scaling for analog speed mode (not commonly used for CANopen projects)

Schneider Lexium32 (LXM32) Full Series Drive Model List

3 main branches: LXM32C (Basic Analog) / LXM32A (Impuls + Modbus) / LXM32M (CANopen bus type, LXM32MD72N4 belongs to this branch)

Suffix-Erklärung:

M2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC

Dxx: Number after D = peak current (A), continuous current = 1/3 of peak current

Status: Full series discontinued, only available on spare parts market

  1. LXM32M (CANopen-Bustyp, High Priority, includes LXM32MD72N4)

Single-phase 200~240V (Suffix M2)

ModellSpitzenstromDauerstrom230V Rated Power
LXM32MD12M212A4A0.75kW
LXM32MD18M218A6A1.0kW
LXM32MD30M230A10A1.6kW
LXM32MD42M242A14A2.5kW
LXM32MD57M257A19A3.5kW

3-phase 208~480V (Suffix N4, your series)

ModellSpitzenstromDauerstrom400V Rated Power
LXM32MD12N412A4A0.9kW
LXM32MD18N418A6A1.8kW
LXM32MD30N430A10A3kW
LXM32MD42N442A14A4.5kW
LXM32MD57N457A19A5.5kW
LXM32MD72N472A24A7kW
LXM32MD85N485A32A9kW
  1. LXM32A (Pulse/Direction + Modbus, no CANopen, gleiche Nennleistung)

Single-phase M2

LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2

3-phase N4

LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4

  1. LXM32C (±10V analog basic model, speed/current control only, no positioning)

Single-phase M2

LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2

3-phase N4

LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4

  1. Matching Motor Series (BSH / BMH for Lexium32)
  2. BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
  3. BMH Motors: EnDat absolute encoder, Multiturn, IP65; flange sizes 55/70/100/140/190mm
  4. Zubehörliste (General for LXM32)

VW3M8101: Bremswiderstand

VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)

VW3M8102: Line reactor

VW3M8200: Pre-made I/O terminal cable

VW3M8300: CANopen bus cable

VW3M8400: Motorstromkabel

VW3M8500: Encoderkabel

Branch Comparison Overview

ModellreiheSteuerschnittstellePositioning FunctionFeldbusTypische Anwendung
LXM32C±10V Analog❌ No positioningModbusPure speed control
LXM32APuls+Richtung✅ Point positioningModbusPulse PLC control
LXM32MCANopen✅ Electronic gear / Point / HomingCANopenMulti-axis bus synchronization (LXM32MD72N4)

Auswahltipps:

  1. Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
  2. LXM32MD85N4 is the largest model in this series, 9kW
  3. New project replacement: Lexium28 series; only stock/second-hand units available for spare part projects.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen