LXM32: Lexium32 series servo
M: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function)
D72: Peak output current 72A, continuous 24A
N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply
Grundlegende elektrische Spezifikationen
| Artikel | Spezifikation |
| Stromversorgung | 3-phase AC 208~480V, 50/60Hz |
| Nennleistung | 400V-Klasse: 7kW; 230V-Klasse: 5kW |
| Kontinuierlicher Ausgangsstrom | 24A (8kHz carrier frequency) |
| Spitzenausgangsstrom | 72A, sustainable for 5s |
| Eingebauter EMV-Filter | Standard integrated |
| Speed Loop Bandwidth | Up to 1600Hz, hohe Dynamik |
| Trägerfrequenz | 8kHz |
| DC Bus Undervoltage Threshold | 350V (400V-Klasse) |
Kommunikation & E/A
- Feldbus: CANopen (LXM32M model, different from pulse-type LXM32A)
- Digital: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; digitale Ausgänge
- Encoder-Schnittstelle: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
- Schnittstellen: RJ45 debug port, detachable color-coded terminals for convenient cabinet wiring and maintenance
Passende Motoren
Compatible with BSH / BMH 400V class Servomotoren of Lexium32 series. Typical match: 140-flange BSH high-torque motor, continuous torque up to 27.8N·m, peak 90.2N·m, common speed 3000rpm.
Anwendungsszenarien
Verpackungsmaschinen, machine tool feed axes, CNC cutting, Textilmaschinen, material handling conveying, multi-axis synchronization equipment; suitable for automated production lines requiring CANopen bus multi-axis linkage and high dynamic positioning.
Installation & Umfeld
Book-style cabinet mounting, vertical installation on control cabinet DIN rail
Überspannungskategorie: Class III
Max leakage current: 30mA
Recommended wire gauge for power terminals: 3mm², tightening torque 0.5N·m
Fehler & Hinweise zur Inbetriebnahme
- Allgemeine Alarme: Überstrom OC, Overvoltage OV, Undervoltage UV, Encoder Fault, Overheat OH
- Inbetriebnahmesoftware: SoMove, supports online parameter configuration, oscilloscope sampling and automatic inertia tuning
- For high-power working conditions, it is recommended to install an external 1mH line reactor to reduce harmonics and incoming current surges
Ersatz & Auswahlbemerkungen
Pulse-Version der gleichen Serie: LXM32AD72N4 (kein CANopen, Pulsrichtungssteuerung)
Upgrade-Alternative: Schneider Lexium28-Serie; vergleichbare Wettbewerber: Siemens V90, Mitsubishi MR-J4
Notiz: LXM32 ist eine eingestellte Legacy-Serie. Lexium28 wird für neue Projekte bevorzugt; Lager- oder Gebrauchtgeräte sind nur für Ersatzteilprojekte verfügbar.
HS-Code-Referenz
85011099 (Servoantrieb, Überprüfen Sie die Zollklassifizierung vor der Zollanmeldung erneut)
LXM32MD72N4 SoMove-Einschalt-Inbetriebnahme-Parametervorlage
Anwendbar: Lexium32M 7 kW CANopen-Bus-Servo, abgestimmt auf BSH/BMH 400V-Motoren; SoMove-Software, Passwort für den Expertenmodus 696969
Voroperation: Komplette Hardware-Verkabelung inklusive Stromkabel, Encoder, Not-Aus, Bremse, CAN-Bus und 24V-Steuerstromversorgung; Führen Sie zuerst einen Tipptest ohne Last durch, dann Autotuning unter Last; Speichern Sie die Parameter nach der Änderung im EEPROM.
- Grundkonfiguration (Starten Sie einfach die Assistentenseite)
| Parametername | Parameter-ID | Empfohlene Einstellung | Beschreibung |
| Steuerquelle | DEVcmdInterf | Feldbus | LXM32M CANopen-Positionierungsmodus; Wechseln Sie vorübergehend zum Terminal, um lokal zu joggen |
| Motor Selection | Motor Selection | Select corresponding BSH/BMH model | Drive loads motor nameplate parameters automatically; must not select incorrectly |
| Encodertyp | ENC1_type | SinCos / EnDat | Select according to motor encoder; EnDat absolute encoder requires battery module |
| Trägerfrequenz | PWM_Freq | 8kHz | Default for LXM32MD72N4, not recommended to increase |
| Rotationsrichtung | InvertDirOfMove | AUS (Standard) | Set to ON if rotation direction reversed; power cycle required after change |
| Auto Enable on Power-up | IO_AutoEnable | 0 (Disabled) | Disabled during commissioning; can be set to 2 for mass production after safety assessment |
- Axis Limit Parameters (Axis Configuration → Limitations)
| Parametername | Parameter-ID | Empfohlene Einstellung | Beschreibung |
| Maximaler Ausgangsstrom | CTRL_I_max | Motornennstrom | Limit maximum torque to protect machinery; cannot exceed 72A peak of drive |
| Max Motor Speed | M_n_max | Nenndrehzahl des Motors | Typical 3000rpm for BSH/BMH, do not exceed nameplate |
| Positive Software Limit | POS_LIM_P | User unit | Inside mechanical hard limit to prevent overtravel |
| Negative Software Limit | POS_LIM_N | User unit | Identisch mit positivem Grenzwert |
| Not-Aus-Verzögerung | QS_Dec | Brauch | Verzögerung durch Notstopp ausgelöst, sicherheitsrelevant |
- E/A & Sicherheitsparameter (Achsenkonfiguration → IO)
| Parametername | Parameter-ID | Empfohlene Einstellung | Beschreibung |
| Positiver Grenzkontakt | IOsigLIMP | NC, normalerweise geschlossen | Standard für Sicherheitsstandards; auf NEIN einstellen, wenn normalerweise offene Sensoren verwendet werden |
| Negativer Grenzkontakt | IOsigLIMN | NC, normalerweise geschlossen | Das Gleiche wie oben |
| Verzögerung beim Lösen der Bremse | BRK_AddT_Release | 100MS | Bremsmotor: Warten Sie, bis die Bremse gelöst ist, bevor Sie nach der Servofreigabe mit der Bewegung fortfahren |
| Bremsbetätigungsverzögerung | BRK_AddT_Apply | 50MS | Verzögern Sie den Bremsausgang nach der Servodeaktivierung, um ein Absturz der Achse zu verhindern |
| Fehler-Reset | IO_FaultReset | IN-Anschluss zuweisen | Externe Reset-Taste |
- Positionsskalierung (Skalierung, Kern für Positionierungsprojekte)
Benutzereinheiten pro Umdrehung, Beispiel: 10mm pro Umdrehung für Leitspindel, nach Bedarf modifizieren
| Parametername | Parameter-ID | Beispielwert | Beschreibung |
| —| —| —| —|
| Positionszähler | ScalePOS | 10 | Zähler des Weges pro Umdrehung |
| Positionsnenner | ScalePOSdenom | 1 | Nenner; Beispiel: 10mm/U → 10/1 |
| Geschwindigkeitsskalierung | ScaleVEL / ScaleVELdenom | Position verfolgen | Geschwindigkeitseinheit: mm/s |
| Beschleunigungsskalierung | ScaleACCnum / ScaleACCdenom | Position verfolgen | Acceleration unit: mm/s² |
Raw encoder resolution: 16384count/rev for SinCos motors
- Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)
Prioritize SoMove automatic inertia identification + auto-tune, then fine tune
| Parametername | Parameter-ID | Initial Recommendation | Tuning Logic |
| —| —| —| —|
| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |
| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |
| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |
| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |
| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |
| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |
- CANopen Fieldbus Parameters (Key for LXM32M)
| Parametername | Parameter-ID | Empfohlene Einstellung | Beschreibung |
| CAN Node ID | CAN_NodeID | 1~127 | No duplicate for multi-axis, consistent with PLC |
| CAN Baud Rate | CAN_Baud | 500kbit/s | Common setting; use 250kbps for long distance, terminal resistor ON at both bus ends |
| PDO-Mapping | PDO Configuration | Standard positioning PDO | Target position, Statuswort, actual position, Fehlercode |
| Fieldbus Control Mode | Profile Mode | Profile Position | Positionierungskontrolle; select Profile Velocity for speed axis |
| Profile Acc/Dec | PRO_ACC / PRO_DEC | Mechanical dependent | Einheit: user unit/s |
| Quick Stop Ramp | PRO_QSDec | Independent E-stop deceleration | Deceleration upon bus failure |
- Homing Parameters
| Parametername | Parameter-ID | Beschreibung |
| Homing Mode | HOM_mode | 0~35 optional; gemeinsam: limit homing, index homing, direct origin setting for absolute encoder |
| Homing Velocity | HOM_Vel | Niedrige Geschwindigkeit, 50~200 user unit/s |
| Homing Search Velocity | HOM_Vel_Search | Slightly higher than homing speed |
| Homing Offset | HOM_Offset | Mechanical origin offset |
- Überwachung & Fault Log
Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults
Oszilloskop: Sample target position, actual position, folgender Fehler, bus voltage, motor current for resonance and tuning analysis
Speichern: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file
Complete Power-on Commissioning Procedure (Matching Parameter Template)
- Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
- Run Simply Start wizard, select motor model and confirm encoder type
- Configure limit, brake and I/O terminal definition
- Set position scaling and mechanical transmission ratio
- Set CANopen Node ID, baud rate and configure PDO
- Leerlauftest: Aktivieren, joggen, Überprüfen Sie die Drehrichtung, limit and brake logic
- On-load test: Run Auto-tune inertia identification to generate base gains
- Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
- Homing-Test, point positioning test, acceleration/deceleration test
- Save parameters to EEPROM and export .cxm backup file
Vorsichtsmaßnahmen bei der Inbetriebnahme
- Passwort für den Expertenmodus 696969, Wechseln Sie in den Expertenmodus, um erweiterte Parameter zu ändern
- Die automatische Abstimmung muss mit der tatsächlichen Last durchgeführt werden; Im Leerlauf eingestellte Parameter schwanken leicht unter Last
- Ein falscher Bremszeitpunkt führt direkt zum Absturz der Achse; Bremsenfunktion ohne Last bei Erstinbetriebnahme testen
- CANopen-Bus: Aktivieren Sie den Abschlusswiderstand nur am ersten und letzten Gerät am Bus, für Zwischenknoten deaktivieren
- Für Hochleistungs-LXM32MD72N4, Überprüfen Sie vor dem ersten Einschalten die Verkabelung von Netzdrossel und Bremswiderstand
Optionale erweiterte Parameter
Bremswiderstand: BRK_R, BRK_P für Widerstand/Leistung des externen Bremswiderstands, Bus-Überspannungsschutz
Analoger Eingang: KI-Skalierung für analogen Geschwindigkeitsmodus (Wird normalerweise nicht für CANopen-Projekte verwendet)
Schneider Lexium32 (LXM32) Vollständige Liste der Antriebsmodelle der Serie
3 Hauptzweige: LXM32C (Grundlegendes Analogon) / LXM32A (Impuls + Modbus) / LXM32M (CANopen-Bustyp, LXM32MD72N4 gehört zu diesem Zweig)
Suffix-Erklärung:
M2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC
Dxx: Number after D = peak current (A), continuous current = 1/3 of peak current
Status: Full series discontinued, only available on spare parts market
- LXM32M (CANopen-Bustyp, Hohe Priorität, includes LXM32MD72N4)
Single-phase 200~240V (Suffix M2)
| Modell | Spitzenstrom | Dauerstrom | 230V Rated Power |
| LXM32MD12M2 | 12A | 4A | 0.75kW |
| LXM32MD18M2 | 18A | 6A | 1.0kW |
| LXM32MD30M2 | 30A | 10A | 1.6kW |
| LXM32MD42M2 | 42A | 14A | 2.5kW |
| LXM32MD57M2 | 57A | 19A | 3.5kW |
3-phase 208~480V (Suffix N4, your series)
| Modell | Spitzenstrom | Dauerstrom | 400V Rated Power |
| LXM32MD12N4 | 12A | 4A | 0.9kW |
| LXM32MD18N4 | 18A | 6A | 1.8kW |
| LXM32MD30N4 | 30A | 10A | 3kW |
| LXM32MD42N4 | 42A | 14A | 4.5kW |
| LXM32MD57N4 | 57A | 19A | 5.5kW |
| LXM32MD72N4 | 72A | 24A | 7kW |
| LXM32MD85N4 | 85A | 32A | 9kW |
- LXM32A (Pulse/Direction + Modbus, kein CANopen, gleiche Nennleistung)
Single-phase M2
LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2
3-phase N4
LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4
- LXM32C (±10V analog basic model, speed/current control only, no positioning)
Single-phase M2
LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2
3-phase N4
LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4
- Matching Motor Series (BSH / BMH for Lexium32)
- BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
- BMH Motors: EnDat absolute encoder, Multiturn, IP65; flange sizes 55/70/100/140/190mm
- Zubehörliste (General for LXM32)
VW3M8101: Bremswiderstand
VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)
VW3M8102: Line reactor
VW3M8200: Pre-made I/O terminal cable
VW3M8300: CANopen bus cable
VW3M8400: Motorstromkabel
VW3M8500: Encoderkabel
Branch Comparison Overview
| Modellreihe | Steuerschnittstelle | Positioning Function | Feldbus | Typische Anwendung |
| LXM32C | ±10V Analog | ❌ No positioning | Modbus | Pure speed control |
| LXM32A | Puls+Richtung | ✅ Point positioning | Modbus | Pulse PLC control |
| LXM32M | CANopen | ✅ Electronic gear / Point / Homing | CANopen | Multi-axis bus synchronization (LXM32MD72N4) |
Auswahltipps:
- Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
- LXM32MD85N4 is the largest model in this series, 9kW
- New project replacement: Lexium28-Serie; only stock/second-hand units available for spare part projects.
Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter




















NH42-63-318x560.png)