Siemens 6AV2124-0MC01-0AX0 HMI - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Siemens 6AV2124-0MC01-0AX0 HMI - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

elektrisch/

Siemens 6AV2124-0MC01-0AX0 HMI

Basic Product Positioning Order Number: SIEMENS 6AV2124-0MC01-0AX0 Full Model Name: SIMATIC HMI TP1200 Comfort Panel Type: 12.1-inch fully touch industrial human-machine interface (without physical keys) Betriebssystem: Windows CE 6.0, configured via TIA Portal WinCC Comfort Order Number Segment Breakdown (6AV2124-0MC01-0AX0) Segment Definition 6AV2 SIMATIC HMI human-machine interface category 124 Comfort Panel series 0M 12-inch ...

  • Produktdetails
  1. Grundlegende Produktpositionierung

Bestellnummer: SIEMENS 6AV2124-0MC01-0AX0

Vollständiger Modellname: SIMATIC HMI TP1200 Comfort Panel

Typ: 12.1-inch fully touch industrial human-machine interface (without physical keys)

Betriebssystem: Windows CE 6.0, configured via TIA Portal WinCC Comfort

  1. Order Number Segment Breakdown (6AV2124-0MC01-0AX0)
SegmentDefinition
6AV2SIMATIC HMI human-machine interface category
124Comfort Panel series
0M12-inch fully touch TP type
C01Standard hardware, dual communication: DP + PN
0AX0No optional accessories, standard German original unit

III. Core Hardware Specifications

  1. Anzeige & Berühren

Screen: 12.1-Zoll 16:9 TFT wide screen

Auflösung: 1280 × 800 WXGA

Color Depth: 16.77 million colors (24-bit true color)

Backlight: LED, adjustable brightness 0~100%, MTBF 80,000 hours at 25°C

Touch Technology: Resistive touch, supports glove/stylus operation

Montage: Embedded installation in landscape or portrait orientation

  1. Lagerung & Leistung

User Project Memory: 12 MB

External Storage: 1 × SD/MMC card slot (for archiving, recipes, firmware upgrade)

RAM: 128 MB DDR3

Prozessor: ARM Cortex-A9 400 MHz

  1. Electrical Power Supply

Versorgungsspannung: Gleichstrom 24 V, allowable range 19.2~28.8 V

Nennstrom: 0.85 A, typischer Stromverbrauch 20 W

Built-in reverse polarity protection, mandatory PE grounding

Gewicht: Ca. 2.8 kg

  1. Full Interfaces (Rear of Unit)
  2. 2 × PROFINET RJ45 Ports (switch cascading, 10/100 Mbit/s, IRT support)
  3. MPI / PROFIBUS DP Universal Serial Port (for legacy S7-300/400 PLCs)
  4. 2 × USB-Host (Typ A): USB flash drive, mouse, printer
  5. 1 × Mini USB Device Port: Program download and debugging from PC
  6. SD memory card slot
  7. Schutz & Umgebungsbedingungen

Frontplatte: IP65 (wasserdicht, oil-proof, staubdicht; direct mounting outside control cabinet)

Rear Housing: IP20 (for cabinet interior installation only)

Betriebstemperatur: 0°C ~ +50°C (no forced cooling for vertical mounting)

Lagerung / Transport Temperature: -20°C ~ +60°C

Luftfeuchtigkeit: 10%~90%, nicht kondensierend

Maximum Installation Altitude: 2000 M

  1. Ausgeschnitten & Gesamtabmessungen

Overall Outer Size: 330 mm (W) × 241 mm (H)

Control Cabinet Cutout Size: 310 mm × 221 mm

Einbautiefe: Ca. 56 mm

  1. Softwarekompatibilität
  2. Minimum Configuration Software: TIA Portal V11 WinCC Comfort
  3. Fully compatible with TIA Portal V12 ~ V19; firmware upgrade required for V17/V19
  4. Supported Functions:

Trend curves, multi-language switching, user access rights management

Batch recipe read/write, data archiving, alarm logging

Integrierter Webserver, PDF/Excel viewer, media player

Automatic backlight off via PROFIenergy energy saving

VB scripting, direct S7 variable connection to S7-1200/1500/300/400/ET200SP

  1. Typische Anwendungsszenarien

Werkzeugmaschinen, packaging production lines, lithium battery production lines, water treatment systems

HVAC-Systeme, Druckmaschinen, injection molding/die-casting equipment

Retrofit projects requiring compatibility with both new PN PLCs and legacy DP/MPI PLCs

Central control stations requiring large high-definition displays and long-term data archiving

  1. Gleicher Serienvergleich & Ersatzoptionen

Same-Size Same-Series Comparison

ModellCommunication DifferenceDistinction
6AV2124-0MC01-0AX02 × PN + MPI/DPStandard full-communication model, mainstream in market
6AV2124-0QC02-0AX1PROFINET only, no DPEconomical version, not a direct replacement for legacy PLC retrofits

Upgrade / Downgrade Alternatives

  1. Larger screen: TP1500 Komfort (6AV2124-0UC02-0AX1), 15-Zoll
  2. Smaller screen: TP900 Komfort (6AV2124-0JC01-0AX0), 9-Zoll
  3. With physical keys: KP1200 Komfort (6AV2124-1MC01-0AX0)

VII. Common Troubleshooting Matrix

FehlerphänomenGrundursacheSolution Steps
Black screen on power-up, Betriebsanzeige ausInsufficient 24V supply / vertauschte VerkabelungMeasure DC voltage, check positive/negative polarity, inspect fuse
Screen lit but touch offset / unresponsiveFailed touch calibration, surface oil contaminationPerform touch calibration in system; clean panel; reinsert touch cable
Frequent PROFINET disconnectionsIP conflict, poor shielded cable, faulty switchAssign static IP, use shielded Ethernet cable, replace switch port
Program download error, device unrecognizedOutdated TIA Portal version, obsolete firmwareUpgrade panel firmware, match corresponding TIA version
Slow operation, frequent restartsDamaged SD card, project memory overflowReplace SD card, simplify screens/archiving data

VIII. Summary of Selection Advantages

  1. Dual Ethernet ports with PN+DP dual protocols: Compatible with both new and legacy Siemens PLCs, preferred choice for retrofit projects;
  2. 12-inch high-definition wide screen with 16.7 million colors, display performance far superior to Basic Panels;
  3. Industrial IP65 front panel, suitable for oily and dusty workshops;
  4. Complete advanced HMI functions including archiving, Web access and scripting to satisfy complex production line monitoring;
  5. Original German hardware with outstanding stability, 80,000-hour backlight lifespan for 24/7 Kontinuierliche Produktion.

Cross-Brand Comparison Table for Siemens 6AV2124-0MC01-0AX0 (TP1200 Komfort)

Core Positioning of Reference Model

Siemens TP1200 Comfort 6AV2124-0MC01-0AX0

Positionierung: High-end 12-inch industrial HMI, dual-bus support for PROFINET + MPI/DP, 1280×800 wide screen resistive touch, deep TIA integration, advanced archiving/scripting/multi-protocol capability

Ausschnittgröße: 310×221 mm, IP65 front panel, Gleichstrom 24 V power supply

  1. Benchmark International Premium Brands (Original Imported, Same High-End Grade)
  2. Schneider Electric
Benchmark ModelHMIGTU65
Screen12.1-Zoll 16:9, 1280×800, resistive touch
KommunikationDual-Ethernet, RS485/232; supports Modbus TCP, PROFINET, EtherNet/IP
KonfigurationssoftwareVijeo Design’Air, built-in scripting, data archiving, Web server
Matching-Score★★★★☆; No native MPI/DP; communication module required for legacy S7-300/400; nearly identical cutout for direct replacement
Anwendbare SzenarienMixed-brand production lines, projects without PROFIBUS DP reliance
  1. Mitsubishi Electric GT27 Series
Benchmark ModelGT2712-STBA
Screen12.1-Zoll, 1280×800, resistive touch
KommunikationEthernet, RS485; supports MC Protocol, Modbus, PROFINET (optional)
KonfigurationssoftwareGT Works3, large-capacity recipe, trend and alarm archiving
Matching-Score★★★☆☆; Natively optimized for Mitsubishi PLCs; PROFINET/Modbus required for Siemens connection; no native MPI
Anwendbare SzenarienJapanese equipment retrofits, injection molding/machine tool production lines
  1. Rockwell Automation AB PanelView Plus 7
Benchmark Model2711P-T12W21D8S
Screen12.1-inch 1280×800, capacitive multi-touch
KommunikationEtherNet/IP, zwei Ethernet-Ports, PROFINET/Modbus compatible
KonfigurationssoftwareFactoryTalk View ME, robust data traceability, production line MES integration
Matching-Score★★★☆; Powerful industrial control performance but isolated from TIA ecosystem; high retrofit cost for PROFIBUS DP systems
Anwendbare SzenarienAutomotive welding workshops, full lithium battery production lines, all-AB automation projects
  1. Omron NS12 / NA Series
Benchmark ModelNA12W-T01
Screen12-inch wide screen 1280×800, resistive touch
KommunikationEtherCAT, Ethernet, RS485, PROFINET gateway support
Matching-Score★★★; Matches Japanese equipment; Modbus gateway required to connect Siemens PLCs
  1. Mid-to-High-End Taiwanese Brands (Cost-Effective Retrofit Alternatives, Market Preferred)

Weintek cMT3120X (Top-tier model, direct Comfort equivalent)

Screen: 12.1-inch 1280×800 wide screen, resistive touch

Kommunikation: Dual-Ethernet, RS485/232, USB; native S7 MPI/DP, PROFINET, Modbus support

Konfigurationssoftware: EBPro; supports VBS scripting, mass data archiving, remote upload/download, Web viewer

Matching-Score: ★★★★★; The only Taiwanese HMI with native Siemens DP bus compatibility; nearly identical cutout size for direct replacement of legacy Siemens units

Nachteile: No native TIA integration; full project reconfiguration required; WinCC project migration unsupported

Weintek MT8121iE (Economical downgrade alternative)

Resolution 1024×768, single Ethernet port, no native MPI; for simple retrofits with tight budgets, not a full equivalent of TP1200 Comfort

III. Mainstream Domestic Industrial HMIs (Low-Cost Localized Replacement)

  1. Kunlun MCGS TPC1231Ni

Screen: 12.1-Zoll, 1024×768 (4:3 aspect ratio, non-16:9 wide screen)

Kommunikation: Ethernet, RS485; supports S7 Protocol, Modbus; no native DP/MPI

Konfigurationssoftware: McgsPro; mature domestic configuration ecosystem with complete recipe/trend/alarm functions

Matching-Score: ★★★☆; Aspect ratio mismatch requires full screen UI rework; suitable for new projects with PROFINET-only communication

  1. Samkoon AK-121AW

12.1-inch 1280×800 wide screen, Android OS, dual Ethernet + RS485; supports S7 and PROFINET

Vorteile: Niedrige Kosten, built-in WiFi remote access; Nachteile: Inferior industrial stability and archiving capacity vs imported/top-tier Weintek models

  1. Cross-Brand Core Specification Comparison Table
VergleichsartikelSiemens TP1200 Comfort 6AV2124-0MC01Weintek cMT3120XSchneider HMIGTU65Kunlun TPC1231NiMitsubishi GT2712
Bildschirmgröße12.1″ 16:912.1″ 16:912.1″ 16:912.1″ 4:312.1″ 16:9
Auflösung1280×8001280×8001280×8001024×7681280×800
Native MPI/DP✅ Built-in✅ Built-in❌ Module required❌ Optional add-on
Dual Ethernet Ports❌ Single port
Touch TypeWiderstandsfähig (glove-supported)Widerstandsfähig (glove-supported)WiderstandsfähigWiderstandsfähigWiderstandsfähig
Front Panel ProtectionIP65IP65IP65IP65IP67
Native Siemens PLC Compatibility★★★★★ Seamless TIA integration★★★★ Full protocol compatibility★★★★★★★★★
Project MigrationDirect WinCC project upgradeNo direct migration, full screen redrawNo migrationNo migrationNo migration
Archiving & Script PerformanceTop industrial gradeExzellentExzellentMediumExzellent
Price TierHigh-end original (Most expensive)Top-tier Taiwanese (Mittelhoch)Imported Mid-rangeDomestic EconomicalJapanese Mid-High
  1. Auswahl & Replacement Decision Guide
  2. Optimal Direct Replacement (Mixed new & legacy Siemens PLCs with DP devices)

Weintek cMT3120X

Grund: The sole model compatible with both MPI/DP and PROFINET; matching cutout and screen aspect ratio, no cabinet modification required, lowest retrofit cost.

  1. Equivalent Imported Replacement (Overseas production lines, standardized projects)

Schneider HMIGTU65

Recommended only for lines without legacy S7-300/400 DP PLCs; additional communication card mandatory if PROFIBUS DP is used.

  1. New Projects with Tight Budget, S7-1200/1500 Only (PROFINET)

Kunlun TPC1231Ni / Samkoon AK-121AW

Pure Ethernet communication scenario; drastically reduced hardware cost with convenient domestic after-sales support.

  1. Production Lines Matched with Japanese Equipment

Mitsubishi GT2712-STBA

Optimized for Mitsubishi FX/Q/L series PLCs; connect to Siemens PLCs via PROFINET.

  1. Replacement Risk Warnings (Universal Cross-Brand Limitations)
  2. No direct project migration: All third-party HMIs cannot open TIA WinCC projects; all screens, scripts and alarms require full reconfiguration;
  3. PROFIBUS DP limitation: Except Weintek cMT3120X, all other brands lack native MPI/DP ports; DP gateway hardware must be added for legacy S7-300/400 retrofits, increasing total cost;
  4. Aspect ratio discrepancy: Kunlun 1024×768 is 4:3; Original 16:9 screen content will stretch and distort, requiring full UI redesign;
  5. Missing ecosystem linkage: Siemens native functions including PROFIenergy, IRT real-time communication and unified TIA diagnostics are unsupported on third-party HMIs, which only provide basic data read/write capability without advanced features.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen