Vollständiges Modell: RAK-TW.5010S-H
Bestell-Nr.: S55700-P122
Marke: SIEMENS (Building HVAC Series)
Produkttyp: Capillary frost protection thermostat (TW frost-type temperature limit switch)
Core Contact: SPDT single-pole double-throw switching contact
Herkunft: Original imported from Switzerland/Germany
Compatible Power Supply: Wide voltage range AC 24V ~ AC 250V
- Segment-by-Segment Model Code Breakdown
- RAK: General prefix for full series of mechanical capillary temperature switches
- TW: Type Winter Frost, dedicated thermostat for frost protection (low-temperature anti-freeze logic)
- 5010: Temperature measuring range code `-10℃ ~ +50℃`
First two digits 50: Upper limit 50℃
Last two digits 10: Lower limit -10℃
- S: Sleeve-free, no immersion temperature sleeve, fixed only by binding capillary
- H: Standard housing with push-in quick-disconnect terminals
Supplementary coding rules for the same series:
B = Equipped with immersion temperature sleeve
M = With external adjustment knob
TR = High temperature limit type
ST = Overheat protection thermostat
- Terminal Wiring & Contact Logic
Terminaldefinition (SPDT Switching Contact)
Gemeinsames Terminal 1, normally closed circuit 1-3, normally open circuit 1-2
- Frost Protection Action Logic (Triggered by Temperature Drop)
When medium temperature drops to the set frost protection value → contacts switch: Schaltung 1-3 disconnects, Schaltung 1-2 closes, activating heat tracing/circulating pump anti-freeze circuit.
- Reset Logic (Recovered by Temperature Rise)
When temperature rises by a fixed hysteresis of 5K → contacts automatically switch back to 1-3, and the anti-freeze circuit shuts down.
Contact Load Capacity (Wechselstrom 250 V)
Schaltung 1-2 (Frost protection output): 16(2.5)A
Schaltung 1-3 (Normal state signal): 6(2.5)A
Terminal structure: Tool-free push-in wiring, suitable for 0.5~2.5mm² solid and flexible wires.
- Kernelektrik & Mechanische Parameter
- Adjustable Temperature Range: -10℃ ~ +50℃
- Switch Hysteresis: Fixed 5K (5℃), nicht verstellbar
- Capillary Length: Standard 1600mm liquid expansion temperature-sensing capillary
- Schutzklasse: IP43 housing, UV-resistant flame-retardant plastic shell
- Three-in-One Mounting Method: Pipe strap mounting / duct sleeve mounting / wall mounting
- Mechanische Lebensdauer: ≥ 100,000 switching cycles
- Ambient Operating Temperature: -20℃ ~ +60℃
- Abmessungen: 156×72×55mm; Net weight ≈ 320g
- Compliance-Standards: CE, RoHS, DIN EN 14597 safety standard for HVAC thermostats
- Funktionen & Anwendungsszenarien
Kernfunktion
Provides low-temperature frost protection for pipes and air ducts. Automatically activates anti-freeze heat tracing and circulating pumps when medium temperature is too low to prevent water pipe cracking; meanwhile, low-temperature alarm signals can be uploaded to PLC.
Segmented Application Fields
- Central Air Conditioning / Air Duct Systems
Frost monitoring for chilled water pipes and fresh air ducts of air conditioners; activate pipe heat tracing cables under low temperature conditions.
- Heizung & Hot Water Boiler Rooms
Frost protection for plate heat exchangers, water manifolds and outdoor main heating pipelines.
- Building Electromechanical BA Systems
Low-temperature alarm for chillers, cooling tower makeup water pipes and plumbing pipes in underground parking lots.
- Purification / Pharmaceutical HVAC Systems
Anti-freeze interlock for circulating water pipes and process air ducts in clean workshops.
- Cold Chain Supporting & Computer Room Air Conditioning
Frost monitoring for pipelines of outdoor water-cooled units and precision air conditioning water pipes in equipment rooms.
- Heating Pipe Networks in Industrial Workshops
Anti-freeze protection for workshop circulating hot water pipes during winter shutdown.
- Selection Table for RAK-TW Frost Protection Series
| Modell | Temperature Measuring Range | Sleeve Configuration | Core Application Scenario |
| RAK-TW.5010S-H | -10~50℃ | Sleeve-free Type S | Pipe strap frost protection (this model) |
| RAK-TW.5010B-H | -10~50℃ | With immersion sleeve Type B | Immersion temperature measurement for water tanks / water manifolds |
| RAK-TW.1000S-H | 15~95℃ | Sleeve-free | High temperature limit protection for hot water |
| RAK-TW.1200S-H | 40~120℃ | Sleeve-free | Overheat protection for steam and high-temperature heat conduction pipelines |
- Ersatz & Cross-Brand Substitution Instructions
7.1 Direct Substitutes from Siemens Same Series
For water tank immersion application: RAK-TW.5010B-H (only equipped with extra temperature sleeve, identical temperature range and contacts)
For high-temperature overheat protection only: Switch to RAK-TW.1000 series (temperature range 15~95℃)
7.2 Cross-Brand Substitutes with Identical Functions
Danfoss: 060G3450 frost capillary thermostat
Johnson Controls: A11B-4C frost limit switch
Inländische Alternative: Shanghai Fengshen WTQ series capillary frost thermostat
7.3 Notes on Replacement
- Only TW frost type (triggered by temperature drop) verwendet werden kann; TR overheat thermostats (act on temperature rise with opposite logic) are prohibited.
- The capillary length of the substitute should match 1600mm as much as possible to avoid temperature measurement delay.
- The built-in contact is SPDT switching type; it cannot be directly replaced by thermostats with single NO or single NC contacts.
- Strict Usage Prohibitions
- Do not apply to steam or oil media over 50℃ (exceeding the range will permanently damage the capillary).
- The capillary must not be sharply bent or squeezed; minimum bending radius ≥50mm, otherwise temperature measurement will fail.
- IP43 rating is only applicable to indoor or covered outdoor environments; long-term exposure to open rain is forbidden.
- Contacts are only for AC24~250V control circuits; connection to 380V main power circuits is prohibited.
- Do not cut the capillary; length modification will deviate the calibrated temperature measurement accuracy.
Replacement Instructions for Temperature-Sensing Probe (Capillary Bulb) of SIEMENS RAK-TW.5010S-H
- Kernschlussfolgerung
The temperature-sensing probe/capillary cannot be replaced separately by original parts. The temperature bulb, capillary and internal bellows actuator form a sealed integrated welded assembly which cannot be disassembled for replacement.
- The capillary and thermostat body are filled with special expansion liquid and hermetically welded. Disassembly will cause liquid leakage and permanent scrapping.
- Siemens does not sell separate spare capillary probes of 1600mm specification, and split spare parts are unavailable.
- Once the probe is bent, squeezed, leaked or broken, the only compliant solution is to replace the whole unit with RAK-TW.5010S-H.
- Structural Principle (Why the Probe Cannot Be Replaced Separately)
- Working medium: The temperature bulb and capillary are hermetically filled with liquid of high expansion coefficient, which drives the internal micro-switch via thermal expansion and contraction.
- Connection process: The root of the capillary and internal bellows of the housing are integrally brazed and sealed without detachable joints.
- Calibration matching: The 1600mm capillary length, bulb volume and liquid filling volume are uniformly calibrated at factory. Arbitrary probe replacement or capillary length modification will lead to:
Severe shift of operating temperature and out-of-control hysteresis;
Failure of low-temperature anti-freeze logic and risk of pipe cracking;
Non-compliance with DIN EN 14597 HVAC safety thermostat certification and unqualified equipment acceptance.
- Fehlerurteil & Lösungen
3.1 Typical Symptoms of Damaged Probe
Capillary bent and flattened, pipe wall broken with liquid leakage;
Temperature bulb dented or fractured by impact;
Thermostat stays unswitched for a long time with no response via temperature adjustment window;
Operating temperature deviation exceeds ±5℃ and adjustment is invalid.
3.2 Handling Methods
- For formal projects requiring acceptance: Purchase a brand-new complete RAK-TW.5010S-H unit for direct replacement.
- Temporary emergency use (no acceptance requirement, long-term use not recommended): Do not cut or splice the capillary; only bind the intact segment temporarily for temperature measurement with unguaranteed accuracy.
- Complete Substitute Units of the Same Specification (No Mounting Modification Required)
- Direct replacement with original identical model: RAK-TW.5010S-H (Bestell-Nr. S55700-P122, 1600mm capillary without sleeve)
- For water tank immersion application: RAK-TW.5010B-H (identical temperature range, matched temperature sleeve and fully consistent other parameters)
- Installation & Usage Restrictions (To Avoid Probe Damage)
- Minimum bending radius of capillary ≥50mm; sharp right-angle bending, treading and squeezing are forbidden.
- Cutting, truncating and splicing of the capillary are strictly prohibited.
- The temperature bulb can only contact media ≤50℃; contact with high-temperature heat sources or welding slag is forbidden.
- Avoid sharp metal clamps scratching the outer wall of the capillary during pipe binding.
- Do not pull the capillary hard during transportation; leave loose allowance.
- Alternative Cross-Brand Complete Units
If the delivery cycle of Siemens products is long, replace with complete frost capillary thermostats of identical logic:
Danfoss 060G3450 (-10~50℃, 1.6m capillary SPDT frost switch)
Johnson Controls A11B-4C low-temperature frost limit switch