ABB F204B63-2CSF204592R1630

This is a ABB F200 Series 4-pole Type B Residual Current Circuit Breaker (RCCB) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, ...

  • Detalles del producto

Este es un TEJIDO F200 Series 4-pole Type B Disyuntor de corriente residual (RCCB) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, and provides protection against smooth DC leakage current.

  1. Explicación del código del modelo
Segmento de modeloDefiniciónDescripción detallada
F204Modelo básicoF200 Series, 4-pole residual current circuit breaker
BTipo de corriente residualTipo B, capable of detecting AC, pulsating DC and smooth DC residual current (0-1000Hz)
63Corriente operativa nominal63A, continuous current rating
0.03Corriente de funcionamiento residual nominal0.03A = 30mA, high-sensitivity protection against direct human contact
2CSF204592R1630Código de pedidoUnique official ABB identification code for purchasing and traceability
4ELTipo de montajeStandard DIN rail mounting with 4-pole terminals (marked on partial versions)
  1. Especificaciones técnicas principales
CategoríaDatos técnicosObservaciones
Características básicas
Tipo de productoDisyuntor de corriente residual (RCCB)No overload or short-circuit protection; must be used with MCB
SerieSystem pro M compact® F200ABB modular power distribution product line
polacos4PAG (L1, L2, L3, norte)Protection for 3-phase 4-wire systems
Tensión nominal400V y (50/60Hz)Rango de voltaje de funcionamiento: 380-415V
Corriente nominal (En)63ACompliant with IEC/EN 61008-1
Corriente de funcionamiento residual nominal (IΔn)30mamátipo instantáneo (no time delay)
Tipo de corriente residualTipo BComprehensive protection against AC, pulsating DC and smooth DC leakage current
Parámetros de rendimiento
Capacidad de ruptura (IΔm)3elBreaking capacity under rated conditions
Tiempo de funcionamiento≤0.04s @ IΔn=30mAMeets requirements for rapid personal safety protection
Corriente residual nominal no operativa (IΔno)15mamáNo tripping below this value to avoid nuisance tripping
Botón de pruebaIncorporadoFor regular functional testing
Características físicas
Dimensiones (Ancho × Alto × Fondo)70mm × 85mm × 60mmDiseño modular estándar, occupies 4 module units
Montaje35carril DIN mmCumple con EN 50022
Tipo de terminalBi-directional cylindrical terminalsFacilitates cable connection and enhances safety
PesoAprox.. 360gramoWeight per unit
Ambiente & Certificaciones
Temperatura de funcionamiento-25°C ~ +55°CPerformance may be affected beyond this range
Temperatura de almacenamiento-40°C ~ +85°C
Humedad5% ~ 95% (sin condensación)
Protección de ingresoIP20Finger-proof, not suitable for outdoor use
CertificacionesCEI/EN 61008-1, CEI/EN 61008-2-1certificado CE, complies with international safety standards
Lifecycle Status
EstadoObsoleteStock still available via some distributors
Discontinued DateJun-24Official record
  1. Full Model List (F204 Type B)
ModeloCódigo de pedidoCorriente nominalRated Residual CurrentCaracterísticas
F204 B-25/0.032CSF204592R125025A30mamá4-pole Type B, basic model
F204 B-40/0.032CSF204592R140040A30mamá4-pole Type B, medium current
F204 B-63/0.032CSF204592R163063A30mamá4-pole Type B, standard industrial model
F204 B-63/0.12CSF204592R263063A100mamá4-pole Type B, higher sensitivity
F204 B-63/0.32CSF204592R363063A300mamá4-pole Type B, equipment protection
F204 B-63/0.52CSF204592R463063A500mamá4-pole Type B, system protection
F204 B-80/0.032CSF204592R180080A30mamá4-pole Type B, alta corriente
F204 B-100/0.032CSF204592R1100100A30mamá4-pole Type B, extra high current
F204 B-125/0.032CSF204592R1125125A30mamá4-pole Type B, maximum current
F204 B-63/0.03-4TE2CSF204568R163063A30mamáModelo de reemplazo, 4-pole Type B, standard terminals
  1. Soluciones de reemplazo & Equivalentes entre marcas

4.1 Original Manufacturer Replacements

Modelo OriginalModelo de reemplazoReason for ReplacementCompatibilidad
F204 B-63/0.03 (2CSF204592R1630)F204 B-63/0.03-4TE (2CSF204568R1630)Product upgrade with optimized terminal designTotalmente compatible, reemplazo directo
DDA204 B-63/0.03 AP-R (2CSB204592R1630)FI-Block series, diseño integradoIdentical mounting dimensions and functions

4.2 Cross-Brand Compatible Replacements

MarcaModeloTechnical Matching RateObservaciones
SchneideriC60H RCCB 4P 63A 30mA Type B95%Dimensionally compatible, equivalent performance
siemens5SU1356-6KK6390%Slight difference in tripping characteristics
Legrand4102 63 03 B90%Different wiring terminals
chint (Porcelana)NXBLE-400/4P 63A 30mA Type B85%Cost-effective with complete certifications
  1. Entornos de aplicación & Casos típicos

5.1 Aplicaciones recomendadas

Sistemas de automatización industrial: Frequency converters, servo drives, PLC cabinets; protects against smooth DC leakage current.

Equipo médico: Operating rooms, ICU devices; provides top-level leakage protection.

Centros de datos: Sistemas UPS, server cabinets; prevents nuisance tripping caused by power fluctuation.

Energía Renovable: inversores fotovoltaicos, energy storage systems; protects DC side leakage.

Edificios Comerciales: Kitchen equipment, central air conditioning, elevator control systems; protection for 3-phase loads.

5.2 Non-Recommended Applications

Pure residential single-phase loads: Type B is overqualified; Type AC is sufficient.

Outdoor humid environments: IP20 rating is inadequate; additional enclosure protection required.

Áreas peligrosas explosivas: Explosion-proof products must be used.

Applications requiring overload/short-circuit protection: This unit only provides leakage protection and shall be used together with MCB.

5.3 Casos de aplicación típicos

Caso 1: Automotive Manufacturing Workshop

Equipo: Robotic welding systems, converter-driven production lines

Asunto: Frequent nuisance tripping of conventional Type AC RCCBs affected production.

Solución: Install F204 B-63/0.03 to protect against smooth DC leakage generated by converters.

Resultado: Nuisance tripping rate reduced by 90%, production efficiency improved by 15%.

Caso 2: Sala de operaciones del hospital

Equipo: Anesthesia machines, patient monitors, surgical lights

Requirements: El más alto nivel de seguridad, zero nuisance tripping and fast response.

Solución: Adopt F204 B-63/0.03 combined with S204-B63 MCB.

Resultado: Complies with medical equipment safety standards and ensures operational safety.

  1. Solución de problemas & Maintenance Manual

6.1 Fallos comunes & Soluciones

Fenómeno de fallaPosibles causasPasos para solucionar problemas
Tropiezos frecuentes1. Actual circuit leakage1. Test circuit insulation with megohmmeter after power off
2. DC leakage from loads2. Verify if loads require Type B RCCB
3. Product aging3. Check production date; replace if service life exceeds 10 años
4. Terminales de cableado flojos4. Retighten wiring terminals
Failure to trip1. Damaged test button1. Replace test button assembly
2. Internal trip mechanism fault2. Send for repair or replace the unit
3. Cableado incorrecto (neutral wire disconnected)3. Check wiring and ensure neutral wire is properly connected
Cannot be reset1. Mechanical lock failure1. Manually reset after power off; replace if failed
2. Persistent leakage2. Eliminate leakage fault before resetting
3. Temperatura ambiente excesivamente alta3. Mejorar la ventilación y bajar la temperatura ambiente.
Indicator light off1. Damaged indicator lamp1. Replace indicator lamp
2. Fallo del circuito interno2. Send for repair or replace the unit

6.2 Maintenance Procedures

  1. Inspección de rutina (Mensual)

Visually inspect for damage or discoloration.

Press test button to confirm normal tripping and reset.

Check terminals for looseness and overheating marks.

  1. Periodic Maintenance (Annually)

Clean unit surface with dry soft cloth after power cut.

Check firmness of DIN rail mounting.

Measure insulation resistance (≥1MΩ).

Record test results.

  1. Replacement Cycle

Normal operating conditions: 10 años

Ambientes hostiles (temperatura alta / alta humedad): 5~7 years

Frequent tripping conditions: 3~5 years

6.3 Quick Diagnosis Tips

Type B RCCB handles DC leakage well.

Check wiring first for frequent tripping; load type matters most.

Replace unit immediately if test button malfunctions.

Power off and clear faults before resetting.

Replace after 10 years for reliable safety.

  1. Directrices de selección
  2. Residual Current Type Selection: Choose Type B for systems with converters, UPS or medical devices; Type AC for general lighting and sockets; Type A for pulsating DC loads.
  3. Rated Current Selection: Corriente nominal ≥ 1.2 times total load current. 63A is suitable for most industrial control cabinets.
  4. Residual Current Rating Selection: 30mA for personal protection; 100~300mA for equipment protection; 500mA~1A for system protection.
  5. Selección de polos: 2P for single-phase systems; 3P for 3-phase 3-wire systems; 4PAG (con cable neutro) for 3-phase 4-wire systems.
  6. Principio de reemplazo: Prioritize upgraded models from the same series for obsolete products to guarantee identical dimensions and performance.