Schneider GV2P32 Motor Circuit Breaker

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits. Model Code Explanation Code ...

  • Detalles del producto

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits.

  1. Explicación del código del modelo
Segmento de códigoSignificadoDescripción
GV2Serie de productosTeSys GV2 series motor circuit breakers for motor overload and short-circuit protection
PAGTipo de operaciónRotary knob manual control, imported version (domestic equivalent: GV2PM series)
32Clasificación actualAdjustable setting range: 24-32A, for motor circuits with rated current up to 32A

Full Model Definition: GV2P32 = Schneider GV2 series, rotary knob type, 32A rated motor circuit breaker

  1. Especificaciones técnicas básicas
CategoríaPresupuestoObservaciones
Características generales
Tipo de producto3-pole thermal-magnetic motor circuit breaker (MPCB)Cumple con IEC 60947-4-1
Rango de corriente ajustable24-32A (ajustable)Thermal trip with ambient temperature compensation
polacos3PAG (trifásico)Designed for three-phase motor protection
Modo de operaciónRotary knob manual controlWith ON/OFF indicator and lockable function
Parámetros eléctricos
Tensión operativa nominal230-690V y, 50/60HzSuitable for global industrial power grids
Compatible Motor Power15kW @ 400/415V, 50/60HzMaximum applicable power under standard operating conditions
Magnetic Trip Threshold12×In = 384A (Instant short-circuit protection)Fast disconnection upon short-circuit faults
Capacidad de ruptura de cortocircuito10kA @ 400V, 50HzMeets industrial standard requirements
Tipo de terminalTerminales de tornilloApplicable copper wire cross-section: 1.5-25mm²
Físico & Parámetros ambientales
Grado de protecciónIP20Evita el acceso de los dedos a piezas vivas.
Tipo de montajeCarril DIN estándar de 35 mmModular installation, ahorro de espacio
Dimensiones (Ancho×Alto×Profundidad)45×85×95mmCompact design for distribution cabinets
Temperatura de funcionamiento-25℃ ~ +60℃Amplio rango de temperatura para entornos industriales.
CertificacionesCCC, UL, CSA, CAO, Marine Classification (DNV, GL, BV), ATEXMultiple certifications for global application
Información de pedido
Manufacturer Part No.GV2P32Official Schneider model
Standard Order CodeGV2P32Original imported version
  1. Full GV2P Series Model List
ModeloRango de corriente ajustableCompatible Motor Power (400V)Corriente de disparo magnético
GV2P010.16-0.25A0.06kilovatios3.0A
GV2P020.25-0.4A0.12kilovatios4.8A
GV2P030.4-0.63A0.25kilovatios7.6A
GV2P040.63-1A0.37kilovatios12A
GV2P051-1.6A0.75kilovatios19A
GV2P061.6-2.5A1.1kilovatios30A
GV2P072.5-4A1.5kilovatios48A
GV2P084-6.3A3kilovatios76A
GV2P096.3-10A4kilovatios120A
GV2P1010-16A7.5kilovatios190A
GV2P1413-18A11kilovatios216A
GV2P1616-24A11kilovatios288A
GV2P2020-32A15kilovatios384A
GV2P3224-32A15kilovatios384A
GV2P4032-40A18.5kilovatios480A
  1. Modelos de reemplazo & Comparación de competidores

4.1 Internal Schneider Replacements

Modelo OriginalModelo de reemplazoDiferenciasEscenarios de aplicación
GV2P32 (Importado)GV2PM32C (Doméstico)Different origin, minor certification differences; profundidad: 91milímetros (GV2P: 95milímetros)Domestic projects, cost-sensitive applications, CCC certification required
GV2P32GV2ME32 (Domestic push-button type)Push-button operation, parámetros eléctricos idénticosApplications requiring push-button control, limited budget
GV2P32GV3P32 (Upgraded series)Higher breaking capacity and enhanced functionsEnvironments with high short-circuit risk, advanced protection required

4.2 Cross-brand Competitor Comparison

MarcaModeloRango actualpolacosMagnetic Trip RatioPrincipales diferencias
SchneiderGV2P3224-32A3PAG12×InMultiple certifications including marine approval, IP20
TEJIDOMS325-3224-32A3PAG12×InCapacidad de ruptura: 15el, larger dimensions
siemens3RV2031-4KA1024-32A3PAG13×InOptional electronic trip, precio más alto
EatonPKZM0-3224-32A3PAG12×InSpring terminals for easy installation
chintNM1-63S/330025-32A3PAG10×InVentaja de costos, domestic alternative
  1. Entornos de aplicación & Casos típicos

5.1 Aplicaciones recomendadas

Control de motores industriales: Main circuit protection for three-phase motors such as pumps, fans, compresores y transportadores

Equipos OEM: Supporting machine tools, maquinaria de embalaje, printing machines and textile machinery

Building Electrical Systems: Protection for critical motors including air conditioning units, fire water pumps and drainage pumps

Marina & Ingeniería costa afuera: Compliant with marine classification standards for ship power systems

Hazardous Areas: ATEX certified for motor protection in non-explosion-proof zones

5.2 Not Recommended Applications

Single-phase Motors: 3-pole design not suitable for single-phase circuit protection

Frequent Start-Stop Operations: Más que 10 cycles per hour will shorten service life

High Altitude (>2000metro): Derating required (10% reduction per 1000m rise)

Ambientes de vibración severa: Extra reinforcement needed to avoid false tripping

Corrosive Environments: IP20 protection is insufficient; additional enclosure is required

5.3 Casos de aplicación típicos

Caso 1: Water Treatment Plant Pump Protection

Equipo: 3 sets of 15kW submersible three-phase pumps (400V)

Configuración: GV2P32 + LC1D32 Contactor + LRD3322 Thermal Overload Relay (redundant protection)

Outcome: Prevented 3 motor overload faults and 1 short-circuit fault, extending equipment service life by 2 años

Caso 2: Conveyor System in Automobile Manufacturing Plant

Equipo: 12 conveyor lines each equipped with 15kW motor

Configuración: GV2P32 linked with Schneider PLC

Características: Rotary knob enables quick on-site reset and reduces downtime

  1. Solución de problemas & Maintenance Manual

6.1 Fallos comunes & Soluciones

Fenómeno de fallaPosibles causasSoluciones
Frequent thermal tripping1. Sobrecarga del motor1. Check motor load and eliminate mechanical jamming
2. Improper low current setting2. Set current to 1.1 times motor Full Load Current (FLA)
3. Temperatura ambiente excesivamente alta3. Mejorar la ventilación y bajar la temperatura ambiente.
4. Loose terminals causing overheating4. Inspect and tighten terminals
Instant magnetic tripping1. Circuit short circuit1. Power off and test circuit insulation
2. Damaged motor winding insulation2. Measure winding resistance and replace faulty motor
3. Arc short circuit inside contactor3. Inspect contactor contacts and replace if necessary
No cerrar1. Tripping mechanism not reset1. Turn knob to OFF position then re-close
2. Damaged rotary knob2. Check knob linkage and replace damaged parts
3. Internal mechanical failure3. Arrange professional maintenance or replace the breaker
No hay salida después del cierre1. Burned internal contacts1. Apagar, inspect main contacts and replace defective unit
2. Cableado incorrecto2. Verify wiring to ensure correct three-phase connection
3. Faulty tripping mechanism3. Check tripping mechanism and replace if needed

6.2 Maintenance Procedures

  1. Inspección diaria (Semanalmente)

Check knob position and status indication

Look for abnormal heat, odor or noise

Confirm all terminals are tightly connected

  1. Mantenimiento de rutina (Cada 6 Meses)

Power off and remove dust with dry compressed air

Inspect main contacts for burning and oxidation

Test tripping function by simulating overload and short circuit conditions

  1. Annual Maintenance

Check lubrication of internal mechanical components

Verify accuracy of current setting

Retighten all electrical connections

6.3 Quick Diagnosis Tips

Thermal trip? Check load and current setting.

Magnetic trip? Locate short circuit and test insulation.

Fail to close? Reset first; replace for mechanical faults.

Sin salida? Inspect contacts and wiring.

  1. Selección & Pautas de instalación

7.1 Reglas de selección

Coincidencia actual: Motor FLA must fall within 24-32A; recommended setting: FLA × 1.1

Coincidencia de poder: Standard solution for 15kW @ 400V three-phase motors

Coordinación de Protección: Use with contactors and fuses to ensure selective protection

Ambient Derating: Reducir 1% per ℃ above 40℃

7.2 Notas de instalación

Dirección de montaje: Instalación vertical (allowable deviation: ±15°) for normal tripping operation

Autorización: Reserve 10mm space on left & right sides, 20mm on top & bottom for heat dissipation

Estándar de cableado: Copper wire with cross-section 1.5-25mm²; par de apriete: 6-8Nuevo Méjico

Locking Function: Padlock can be fitted to prevent accidental operation, Cumpliendo con las normas de seguridad.

  1. Production Status & Soluciones de actualización

Current Status of GV2P32: In production, no discontinuation plan (as of June 2026)

Mejora & Opciones de reemplazo:

  1. Actualización funcional: GV3P32 (higher breaking capacity and extra protection functions)
  2. Alternativa Doméstica: GV2PM32C (lower cost with equivalent performance)
  3. Intelligent Upgrade: TeSys T series (with communication for remote monitoring)