chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

ABB Power Factor Controller 2GCA294985A0050 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

medidor de electricidad/eléctrico/

ABB Power Factor Controller 2GCA294985A0050

The model 2GCA294985A0050 is not a display screen, but rather an ABB RVC-8 Power Factor Controller (also known as a Reactive Power Compensation Controller). It is used to automatically control the switching of capacitor banks, optimize the power factor of the power grid, and reduce energy consumption and electricity penalty charges due to poor power ...

  • Detalles del producto

The model 2GCA294985A0050 is not a display screen, but rather an ABB RVC-8 Power Factor Controller (also known as a Reactive Power Compensation Controller). It is used to automatically control the switching of capacitor banks, optimize the power factor of the power grid, and reduce energy consumption and electricity penalty charges due to poor power factor.

  1. Core Product Information
ArtículoDetailed Specifications
ModeloRVC-8 (2GCA294985A0050), Old Order No.: 10148029
Tipo de producto8-output Power Factor Controller
Rango de voltaje100V~440V, suitable for most low-voltage power grids
Corriente de entrada1A or 5A (RMS), requires connection to a Current Transformer (Connecticut)
Rango de frecuenciaAuto-adapts to 50/60Hz
Display TypeBlack and white LCD display with functional icons
Modo de controlFully automatic control, supporting multiple switching strategies such as Integral, Cyclic, and Direct
Temperatura de funcionamiento-25°C~+70°C (ambient); Triggers an alarm if internal temperature exceeds 85°C
Consumo de energíaMax 8VA
Output Circuits8 programmable relay outputs, each rated at 16A/250VAC
  1. Características funcionales principales
  2. Comprehensive Parameter Monitoring:

Measures and displays key grid parameters including voltage, actual, factor de potencia, THDV (Total Harmonic Voltage Distortion), and THDI (Total Harmonic Current Distortion).

  1. Flexible Control Strategies:

Fully programmable switching sequence supporting both共补 (Total Phase Compensation) and 分补 (Individual Phase Compensation).

Switching interval adjustable from 1 second to 999 artículos de segunda clase.

Target power factor adjustable from 0.7 (inductive) a 0.7 (capacitive).

Auto-adapts to grid phase sequence and CT terminal connection.

  1. Múltiples funciones de protección:

Over-voltage / Under-voltage protection.

Over-temperature protection (internal temperature > 85°C).

Excessive harmonic protection (THDV threshold超限).

Power-off memory function (maintains capacitor bank state for power off durations up to 40ms).

  1. User-friendly Interface:

Upgraded icon-based UI allows for quick commissioning without a manual. The compact design saves cabinet space.

  1. Escenarios de aplicación

Industrial Plants: Reactive power compensation for inductive loads such as inverters, compresores, and motors.

Commercial Complexes: Reactive current compensation for devices like central air conditioners and elevators.

Centros de datos: Stabilize the power supply system and improve energy efficiency.

New Energy Power Stations: Optimize the reactive power output of photovoltaic inverters and wind turbine converters to improve grid connection efficiency.

Public Facilities: Power distribution systems for public buildings such as hospitals, schools, and subway stations.

  1. RVC Series Full Model Comparison
ModeloNúmero de pedido.Number of Output CircuitsCaracterísticas principales
RVC-32GCA294983A00503-circuitoSuitable for small capacitor cabinets
RVC-62GCA294984A00506-circuitoMedium-scale capacitor compensation system
RVC-82GCA294985A00508-circuitoThis product; suitable for medium and large capacitor cabinets
RVC-102GCA294986A005010-circuitoLarge-scale capacitor compensation system
RVC-122GCA294987A005012-circuitoExtra-large scale capacitor compensation system
RVC-L-122TAZ460104R112012-circuitoLong-life version, replacing the old RVC-12
RVT-L-182TAZ460103R018018-circuitoDedicated to 3-phase individual compensation, supports 18 output circuits
  1. Replacement Solutions
  2. ABB Original Factory Upgrade Replacements:

RVC-L Series: Long-life version, p.ej., RVC-L-12 (replaces RVC-12).

RVT Series: More advanced power factor controllers with support for more functions and communication protocols.

  1. Other Brand Replacements:

Schneider: VPL06N/VPL12N series.

siemens: 7KM series power factor controllers.

Domestic Replacements: Similar products from brands such as Chint and Delixi.

  1. Technical Documentation and Support
  2. Notas: The RVC-8 has been discontinued. It is recommended to prioritize upgrading to the RVC-L series or RVT series products for better performance and a longer service life.

Complete List of ABB Power Factor Controller Models and Comparison with Mainstream Brands

  1. Complete List of ABB Power Factor Controller Models
  2. RVC Series (Interrumpido; recommended upgrade to the RVC-L series)
ModeloNúmero de pedido. (New/Old)Number of OutputsEspecificaciones principalesEscenarios de aplicación
RVC-32GCA294983A0050/101480273-circuito100-440V y, 1/5A CT, IP20Small capacitor cabinets, stable load systems
RVC-62GCA294984A0050/101480286-circuito100-440V y, 1/5A CT, IP20Medium compensation systems, edificios comerciales
RVC-82GCA294985A0050/101480298-circuito100-440V y, 1/5A CT, IP20Medium and large compensation systems, industrial plants
RVC-102GCA294986A0050/1014803010-circuito100-440V y, 1/5A CT, IP20Large compensation systems, centros de datos
RVC-122GCA294987A0050/1014803112-circuito100-440V y, 1/5A CT, IP20Extra-large compensation systems, new energy power stations

Características principales: Black and white LCD icon-based UI, supports Integral/Cyclic/Direct control, includes THDV/THDI monitoring, and features Over-voltage/Under-voltage/Harmonic/Over-temperature protection.

  1. RVC-L Series (RVC upgrade, diseño de larga duración)
ModeloNúmero de pedido.Number of OutputsEspecificaciones principalesUpgrade Advantages
RVC-L-32TAZ460104R00303-circuito100-440V y, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-62TAZ460104R00606-circuito100-440V y, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-82TAZ460104R00808-circuito100-440V y, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-102TAZ460104R010010-circuito100-440V y, 1/5A CT, IP20Extended service life, optimized algorithms
RVC-L-122TAZ460104R112012-circuito100-440V y, 1/5A CT, IP20Extended service life, optimized algorithms; most widely used

Características principales: Retains all RVC functionality with improved component quality, extended MTBF (Mean Time Between Failures), and greater stability and reliability.

  1. RVT Series (Advanced features, supporting individual phase compensation)
ModeloNúmero de pedido.Number of OutputsEspecificaciones principalesFunciones principales
RVT-6100791826-circuito100-460V y, 1/5A CTIntegral/Cyclic/Direct control, individual/total phase compensation, harmonic monitoring
RVT-121007916112-circuito100-460V y, 1/5A CTIntegral/Cyclic/Direct control, individual/total phase compensation, harmonic monitoring
RVT-12-3PCustom12-circuito100-460V y, 1/5A CT3-phase independent measurement, energy calculation, support for all connection types

Características principales: More precise measurement, support for 3-phase unbalanced systems, independent measurement of each phase, suitable for complex load environments.

  1. RVT-L Series (Latest touchscreen series, most powerful features)
ModeloNúmero de pedido.Number of OutputsControl TypeVentajas principales
RVT-L-18 3P(norte)2TAZ460103R018018-circuitoContactor switching (passive)Touchscreen UI, 3-phase full parameter measurement, harmonic spectrum analysis
RVT-L-18 3P(t)Custom18-circuitoThyristor switching (active DC12V)Dynamic compensation, fast response to impact loads
RVT-L-24 3P(norte)Custom24-circuitoContactor switching (passive)Maximum number of output circuits, suitable for extra-large systems
RVT-L-24 3P(t)Custom24-circuitoThyristor switching (active DC12V)Dynamic compensation, maximum number of output circuits

Características principales: Color touchscreen, 18/24 output circuits, support for low/medium voltage applications, optional Modbus communication, suitable for high-end projects and smart grids.

  1. Comparison List of Mainstream Brand Power Factor Controllers (Categorized by Number of Output Circuits)
Number of OutputsTEJIDOSchneidersiemenschintDeliciosoMain Feature Comparison
3-circuitoRVC-L-3VPL03N7KM2111NWKL1-3JKL2B-3ABB/RVC-L: Harmonic monitoring; Schneider: Diseño modular; siemens: Strong communication; Doméstico: High cost-performance ratio
6-circuitoRVC-L-6VPL06N7KM2112NWKL1-6JKL2B-6TEJIDO: Flexible switching strategies; Schneider: Plug-and-play; siemens: Strong diagnostic capabilities
8-circuitoRVC-L-8VPL08N7KM2113ZT-830-8JKL5C-8TEJIDO: Integral/Cyclic/Direct 3 modes; Doméstico: Significant cost advantage
12-circuitoRVC-L-12VPL12N/NVPL12N7KM2114NWKL1-12JKL2C-12TEJIDO: Over-temperature protection; Schneider: 24V auxiliary power; siemens: Detailed fault records
18-circuitoRVT-L-18NVPL18N/NVPL18T7KM2318ZT-830-18CustomABB/RVT-L: Touchscreen; Schneider: Contactor/Thyristor dual version; siemens: Advanced algorithms
24-circuitoRVT-L-24NVPL24N/NVPL24T7KM2324CustomCustomABB/RVT-L: Harmonic spectrum; Schneider: Maximum number of circuits; siemens: Industrial network integration
  1. Comparison Table of Core Technical Characteristics by Brand
MarcaSerie representativaVentajas principalesDesventajasEscenarios de aplicación
TEJIDORVC-L/RVT-LHigh measurement accuracy, protección integral, strong harmonic analysis, larga vida útilPrecio más alto, some models require customizationAutomatización industrial, new energy, high-end commercial projects
SchneiderVPL/NVPLDiseño modular, plug-and-play, rich communication protocolsGeneral harmonic processing capabilityCommercial buildings, centros de datos, infrastructure
siemens7kmPowerful diagnostic functions, excellent industrial network integration, advanced algorithmsComplex operation, steep learning curveIndustria pesada, sistemas de energía, large factories
chintNWKL1/ZT-830High cost-performance ratio, operación sencilla, compatible with domestic power gridsFew high-end features, limited communication optionsSmall and medium enterprises, construcción civil, renovation projects
DeliciosoJKL2B/JKL5CAffordable price, good reliability, comprehensive after-sales serviceLack of advanced algorithms, weak harmonic monitoringSmall factories, tiendas, residential power distribution
  1. Selection Guidelines and Replacement Recommendations
  2. RVC Series Upgrade: Existing RVC users are recommended to directly upgrade to the corresponding RVC-L model to maintain compatibility of control logic and obtain a longer service life and more stable performance.
  3. Selection of Number of Circuits: Select the number of circuits based on 1.2 times the total reactive power of the system, and reserve 2-3 circuits for future load increases.
  4. Control Type Selection:

Stable Loads: Choose contactor switching (Tipo N) for low cost and long service life.

Impact Loads: Choose thyristor switching (Type T) for fast response and no inrush current.

  1. Harmonic Considerations: If the system THDV > 5%, it is recommended to select a model with harmonic protection functions (such as ABB RVT-L, Schneider NVPL), and use it in conjunction with reactors.
  2. Quick Reference Table of Technical Parameters (Universal for the entire series)
Categoría de parámetroValor típicoNotas
Operating Voltage100-440V y (RVC/RVC-L), 85-305V y (RVT-L)Wide voltage range, compatible with global power grids
Current Input1A or 5A CT (RMS)Requires connection to a Current Transformer
Frequency AdaptationAuto-adapts to 50/60HzNo manual setting required
Target Power FactorAdjustable from 0.7 (inductive) a 0.7 (capacitive)Meets requirements of different power grids
Switching IntervalAdjustable from 1 second to 999 artículos de segunda claseIndependent of load changes
Funciones de protecciónOver-voltage/Under-voltage/Harmonic/Over-temperature/Power-off memoryComprehensive protection for capacitors and the power grid
Método de instalaciónDIN rail installation (ancho: standard 96mm)Saves cabinet space