Advantech EKI-1526 16-Port Serial Device Server - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Advantech EKI-1526 16-Port Serial Device Server - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Advantech EKI-1526 16-Port Serial Device Server

The Advantech EKI-1526 is an industrial-grade 16-port RS-232/422/485 serial device server featuring a 1U rack-mount design and dual Ethernet redundancy. It seamlessly connects traditional serial devices to the Ethernet network for remote management and data acquisition. Its core advantages include software-configurable serial port types, wide operating temperature range, high ESD protection, and rich communication protocol ...

  • Detalles del producto

The Advantech EKI-1526 is an industrial-grade 16-port RS-232/422/485 serial device server featuring a 1U rack-mount design and dual Ethernet redundancy. It seamlessly connects traditional serial devices to the Ethernet network for remote management and data acquisition. Its core advantages include software-configurable serial port types, wide operating temperature range, high ESD protection, and rich communication protocol support. Se aplica ampliamente en la automatización industrial., intelligent transportation, energy management and other fields.

  1. Definición del segmento del modelo (Standard Nomenclature)
SegmentoStandard CodeSignificadoDescripción detallada
EKIEKIAdvantech Industrial Ethernet Communication Product LineEmbedded Ethernet Interface, focusing on industrial network communication equipment
15261526Product Series Number16-port serial device server (1528 is the 8-port version)
Suffix Codenorte / I / TI / VCC, etc..Expansión de funciones / Power Type• N: GigabitEthernet
• I: Wide-temperature version (-40°C~70°C)
• TI: Wide-temperature + fuente de alimentación CC
• VDC: fuente de alimentación CC (12-48VCC)
• CE: Compliant with EU CE certification
VersiónV2Hardware Revision2nd-generation hardware with upgraded performance, supporting baud rate up to 976.5 kbps
  1. Parámetros de especificación principales (Official Data)
CategoríaParámetroModelo estándar (EKI-1526)Wide-Temp Model (EKI-1526I)Observaciones
Características básicasTipo de producto16-Port Serial Device ServerIgual que a la izquierda1U rackmount, SECC metal casing, IP30 protection
Dimensiones (Ancho×Alto×Profundidad)438×43.6×259.2 mmIgual que a la izquierdaStandard 19-inch rack mounting
Peso3.1 kilosIgual que a la izquierdaExcluding packaging
Temperatura de funcionamiento-10°C ~ 60°C-40°C ~ 70°CTemperatura de almacenamiento: -40°C ~ 80°C
Humedad5%~95% RH, sin condensaciónIgual que a la izquierdaAdaptable to humid industrial environments
MTBF>60,000 horasIgual que a la izquierdaHigh-reliability design
Network InterfacePort Quantity2 × RJ45Igual que a la izquierdaLAN redundancy supported, auto MDI/MDIX
Velocidad10/100 mbps (EKI-1526)Igual que a la izquierdaDual independent MAC addresses, network redundancy
10/100/1000 mbps (EKI-1526N)
Isolation ProtectionIncorporado 1.5 kV magnetic isolationIgual que a la izquierdaAnti-electromagnetic interference, improved stability
Serial CommunicationPort Quantity16 portsIgual que a la izquierdaSoftware configurable serial mode
Interface TypeDB9 (RJ45 optional)Igual que a la izquierdaSupports RS-232/422/485 switching
Velocidad de baudios50~921.6 kbps (Estándar)Igual que a la izquierdaCustom baud rate supported
50~976.5 kbps (V2 Version)
Data Bits5, 6, 7, 8Igual que a la izquierdaFlexible compatibility with various serial devices
ParityNinguno / Odd / Even / Mark / SpaceIgual que a la izquierdaFull compatibility with industrial protocols
Stop Bits1, 1.5, 2Igual que a la izquierdaMeets communication requirements of different devices
Protección15KV ESD full-serial protectionIgual que a la izquierdaIndustrial-grade anti-static design
RS-485 FeatureAutomatic data flow control, 2/4-wire supportIgual que a la izquierdaNo manual TX/RX direction switching required
Sistema de energíaAC Input100~240 VAC, 50~60 HzIgual que a la izquierdaConsumo de energía: 5.6W., 0.3A@110V, 0.2A@220V
DC Input12~48 VDCIgual que a la izquierdaWide voltage input for industrial power supply
ProtecciónOver-voltage / Over-current / Reverse polarity protectionIgual que a la izquierdaIndustrial-grade power protection design
Software FunctionsOperation ModesVirtual COM, TCP Server/Client, UDP, Modbus GatewayIgual que a la izquierdaMulti-protocol conversion capability
Configuration MethodsWeb Browser, Telnet, Windows Utility, Serial ConsoleIgual que a la izquierdaFlexible for different management scenarios
Network ProtocolsIPv4/IPv6, DHCP, DNS, SNMP MIB-IIIgual que a la izquierdaComplete network management support
Security FeaturesPassword protection, IP filtering, SSL/TLS (V2 version)Igual que a la izquierdaEnsure secure data transmission
CertificacionesCumplimientoCE, FCC, UL, Class I Div 2Igual que a la izquierdaCompliant with global industrial safety standards
  1. Lista de accesorios (Officially Recommended)
Nombre del accesorioFunciónRecommended QtyObservaciones
Rack Mount KitStandard 19-inch rack mounting brackets1 set per unitStandard included
Power CordAC version: IEC C13 power cable1 pc per unitSelect according to power type
DC version: Phoenix terminal power cable
Serial CableDB9-RJ45 adapter cable / DB9 straight-through cable1 pc per portFor serial device connection
Ethernet CableCat5e/Cat6 network cable (1-2metro)2 pcs per unitFor dual Ethernet port connection
Configuration SoftwareAdvantech Device Manager1 colocarAvailable via CD or official website
Manual de usuarioPaper / electronic operation guide1 copyIncludes quick configuration steps
Tarjeta de garantía5-year warranty certificate1 copyStandard warranty for Advantech industrial products
  1. Competidor & Lista de reemplazo entre marcas (Directly Compatible)
MarcaModeloParámetros claveCompatibilidad / DiferenciaRecomendación de reemplazo
Advantech Same SeriesEKI-1526N16-port, GigabitEthernet, IP30Higher network speed, identical other specsChoose for high-speed network transmission
Advantech Same SeriesEKI-1526I16-port, wide temperature (-40°C~70°C)Extended operating temperature rangeExterior / harsh environment applications
Advantech Same SeriesEKI-15288-port, same other parametersHalf port count, tamaño más pequeñoScenarios with fewer serial devices
MOXANPort 5616-8-DT16-port, RS-232/422/485, dual LANSimilar protocol support, more mature configuration softwareUsers familiar with MOXA ecosystem
siemensSCALANCE XB-200 SeriesIndustrial switch + serial server moduleHigh integration, seamless connection with Siemens PLCPriority for Siemens automation systems
Contacto FénixFL SWITCH 2208 + PSI-MODEMCambiar + serial gateway combinationDiseño modular, strong scalabilityScenarios requiring flexible port expansion
Alternativa DomésticaZLG GCOM80-2NET16-port, wide temperature, full isolation30%-50% precios má bajo, fully compatible functionsProyectos sensibles a los costos & localization demands
  1. Directrices de selección & Soluciones alternativas

Selection Mnemonic

> 16 serial ports with dual LAN, software switch for multi-RS mode;

> I for wide temp, N for gigabit, AC/DC power as required.

Consideraciones clave de selección (5 Dimensiones)

  1. Port Quantity Matching

16 serial devices: Choose standard EKI-1526

8 serial devices: Choose EKI-1528 (8-port version)

Más que 16 puertos serie: Daisy-chain multiple units or select EKI-1548 (32-port)

  1. Operating Environment Adaptation

Entorno industrial estándar (-10°C~60°C): EKI-1526 standard version

Extreme environment (-40°C~70°C): Choose EKI-1526I wide-temperature model

Exterior / humid environment: Add IP67 protective enclosure

  1. Network Requirement Evaluation

100Mbps network: EKI-1526 standard

Gigabit / high-speed data transmission: Choose EKI-1526N

Network redundancy & alta confiabilidad: Dual LAN auto-switching as standard

  1. Power Supply Selection

Room / computer room: EKI-1526 (AC power)

Industrial field / no commercial AC: EKI-1526T-VDC (12-48VCC)

Unstable power grid: Add UPS power protection

  1. Function Expansion Requirements

Security encryption: Choose V2 version (supports SSL/TLS)

Modbus Gateway: Standard built-in, no extra license required

Remote management: Supports SNMP, integrable with industrial network management system

Recommended Alternative Solutions (3 Scenarios)

Escenario de aplicaciónRecommended SolutionVentajas
Optimización de costosAlternativas domésticas (ZLG GCOM80-2NET, Kyland KIEN Series)30%-50% reducción de costos, function compatible, meets localization requirements
Protocol UpgradeEKI-1526 + Advantech Protocol ConverterAdd OPC UA, PROFINET and other industrial protocol conversion
Function IntegrationEKI-1526V2 + Advantech Edge Computing ModuleAll-in-one serial data collection + computación de borde + cloud platform access
  1. Air Freight Compliance & Certificación CE (International Trade)
  2. Air Freight Compliance

No built-in lithium battery / super capacitor: Classified as ordinary industrial electronic equipment, no special air freight restrictions

Transport Category: Clase 9 miscellaneous dangerous goods (non-dangerous in actual transport)

HS Code: 85176239 (Industrial network communication equipment)

Packaging Standard: Compliant with ISTA 3A to avoid transport damage

  1. CE Certification Information

Compliant Directives: 2014/30/EU (CEM), 2011/65/EU (RoHS), 2014/35/EU (LVD)

Test Standards: EN 55011 (Industrial EMI), EN 61000-6-2 ( Industrial immunity)

Certification Number: Available on Advantech official website by entering the full model number

  1. Application Cases & Adaptación de la industria

Casos de aplicación típicos

  1. Smart Factory: Connect 16 PLCs/sensors; adopt dual Ethernet redundancy for production line data acquisition; support Modbus TCP/RTU protocol conversion and seamless MES system connection.
  2. Smart Grid: Red 16 serial substation devices (protection relays, medidores de energía); wide-temperature model adapts to outdoor conditions; dual LAN ensures reliable data transmission.
  3. Rail Transit: 16-channel sensor data collection for train carriages; DC power adapts to vehicle system; high ESD protection against complex electromagnetic environments.
  4. Industria petroquímica: Remote monitoring of 16 instrument data in refineries; Class I Div 2 certification meets hazardous area requirements; support remote configuration and fault diagnosis.

Industry Adaptation Guide

IndustriaAdaptation AdvantagesConfiguración recomendada
Automatización IndustrialMulti-serial centralized management, flexible protocol conversionEKI-1526N + Virtual COM Software + Industrial Switch
Energy & FuerzaWide-temperature design, alta confiabilidad, dual LAN redundancyEKI-1526I + DC Power + Lightning Protection Module
Rail TransitVehicle power compatible, vibration resistant, enhanced EMCEKI-1526TI-VDC + Shockproof Mounting Bracket
PetroquímicoExplosion-proof certification, remote management, bajo consumo de energíaEKI-1526I + Safety Isolator + Redundant Power Supply

The Advantech EKI-1526 is a highly reliable and flexible industrial-grade serial device server. With its 16-port high-density design, software-configurable serial modes, and dual LAN redundancy, it perfectly meets the network transformation demands of serial devices in industrial sites. Supporting multiple operation modes including Virtual COM, TCP/UDP and Modbus Gateway, it can be seamlessly integrated into mainstream industrial automation systems to realize remote management and data acquisition of traditional serial equipment. Its wide-temperature versions and multiple power options further extend its applicability in extreme environments and special scenarios.

Full EKI-1526 Series Model List

  1. 16-Port Main Models
Modelo completoLAN SpeedOperating TempFuente de alimentaciónCaracterísticas principales
EKI-152610/100mbps-10℃~60℃CA 220 VStandard 16-port RS232/422/485
EKI-1526I10/100mbps-40℃~70℃CA 220 VIndustrial wide-temperature version
EKI-1526N10/100/1000mbps-10℃~60℃CA 220 VEstándar + Dual Gigabit LAN
EKI-1526NI10/100/1000mbps-40℃~70℃CA 220 VWide-temperature + Dual Gigabit
EKI-1526-VDC10/100mbps-10℃~60℃12~48VDCDC power version
EKI-1526I-VDC10/100mbps-40℃~70℃12~48VDCWide-temperature + DC power
EKI-1526N-VDC10/1000mbps-10℃~60℃12~48VDCGigabit + DC power
EKI-1526V210/100mbpsStandard TempC.A.V2 hardware, higher baud rate + SSL encryption
  1. Related Series Models (8/32-Port Alternative)
ModeloPuertos seriePosicionamientoDirect Replacement Scenario
EKI-15288 PortsSmall-site application≤8 serial devices, space & cost saving
EKI-154832 PortsHigh-density cabinetEncima 16 puertos serie, one unit replaces two EKI-1526

Unified Model Suffix Definition

Sin sufijo: Standard temperature -10~60℃, 100Mbps LAN, AC220V power

I: Industrial wide-temperature -40℃~70℃

norte: Network upgraded to Dual Gigabit Ethernet

VCC: Supports 12~48VDC wide-range DC input

TI: Wide-temperature + industrial vehicle-grade DC adaptation

V2: 2nd-gen hardware, max baud rate 976.5kbps, SSL/TLS encryption supported

Quick Hardware Wiring Steps

  1. Power on the device: AC for mains power / DC for 12-48V DC input
  2. Network port: LAN1/LAN2 connect to switch or PC, dual LAN redundancy supported
  3. Serial port: DB9 connects to RS232/485/422 devices; mode switch via web page
  4. Power indicator: PWR steady on = normal; LINK flashing = network communication active

Basic Web Configuration Steps

  1. Set PC IP to the same segment: 192.168.1.incógnita
  2. Enter default IP in browser: 192.168.1.1
  3. Default username / password: `admin / admin`
  4. Basic settings:

Modify device IP, subnet mask, gateway

Global serial config: unified baud rate / bits de datos / parity / stop bits

Serial mode: select Virtual COM / TCP Server / TCP Client / Modbus Gateway as required

3 Common Application Configuration Guides

  1. Virtual COM Mode (Más común)

Solicitud: Legacy serial software / SCADA software used as local COM port

  1. Set serial mode to Virtual COM in web page
  2. Install Advantech Device Manager on PC
  3. Search device → bind serial ports → auto assign COM3~COM20
  4. Use the corresponding COM number directly in SCADA or application software
  5. Modbus Gateway Mode (For PLC & Metros)

Solicitud: Convert Modbus RTU to Modbus TCP for serial instruments over Ethernet

  1. Set serial mode to Modbus Gateway in web page
  2. Configure serial parameters: 9600/8N1 to match instrument
  3. Set slave address and polling interval
  4. Host access via Modbus TCP using device IP + port number
  5. Dual LAN Redundancy Configuration (Dual Link Anti-Disconnection)

Solicitud: Critical production lines, power grid, unattended computer rooms

  1. Enter Network → Redundancy in web interface
  2. Enable Dual LAN Redundancy
  3. Connect LAN1 and LAN2 to different switches respectively
  4. Automatic seamless switchover and no data loss if any network cable fails

Quick Troubleshooting

  1. Cannot access web page: Set PC IP to 192.168.1.xxx, disable firewall
  2. Serial communication failure: Switch RS232/485/422 mode in web page, verify baud rate and parity
  3. Virtual COM offline: Upgrade driver, set static device IP, avoid DHCP dynamic IP
  4. Dual LAN no switchover: Confirm redundancy is enabled; ensure two switches are not in the same loop

Advantech EKI-1526 Dual LAN Redundancy Full Configuration Guide

The EKI-1526 supports Master-Backup dual LAN redundancy with switchover time <1 segundo. After enabling via Web UI, it automatically detects link faults and performs seamless failover to ensure uninterrupted industrial communication.

  1. Dual LAN Redundancy Working Principle

The EKI-1526 is equipped with two independent Ethernet ports (LAN1/LAN2) and independent MAC addresses:

Master Port: Carries all network traffic under normal operation

Backup Port: Monitors master port status in real time and takes over only when master port fails

Switchover Mechanism: Automatically switches to backup port upon LAN link down (cable disconnection / switch failure), switchover time <1 second with no data loss

Restore Mechanism: After master port recovers, configurable for auto switch back or remain on backup port

  1. Hardware Connection Preparation

Recommended Topologies (Avoid Single Point of Failure)

Connection ModeDescripciónEscenario de aplicación
Dual Switch RedundancyLAN1 to Switch A, LAN2 to Switch B; both switches connect to core networkCritical production lines, unattended rooms; prevent single switch failure
Single Switch Dual PortLAN1/LAN2 connect to different ports of the same switchPresupuesto limitado; only protect against single port / cable failure
Dual Network SegmentationLAN1 for production network, LAN2 for management network; service & management isolatedSecurity scenarios requiring network isolation

Hardware Wiring Steps

  1. Power off the device, connect serial devices and power supply
  2. Connect LAN1/LAN2 to switches (dual switches recommended)
  3. Encendido; check indicators: PWR steady on, both LAN LINK lights flashing normally
  4. Detailed Web Configuration Steps
  5. Basic Network Settings (Obligatorio)
  6. Set PC static IP: 192.168.1.incógnita (same segment as device default)
  7. Browser access default IP: 192.168.1.1, login: `admin/admin`
  8. Go to Ethernet Configuration → Ethernet 1: Set master port IP, subnet mask, gateway
  9. Go to Ethernet Configuration → Ethernet 2: Set backup port IP (same segment recommended, p.ej. 192.168.1.2), subnet mask, gateway
  10. Click Save, device auto restarts (acerca de 1 minuto)
  11. Enable Dual LAN Redundancy (Core Config)
  12. Log in Web UI again after reboot
  13. Enter Network → Redundancy
  14. Check Enable Dual LAN Redundancy
  15. Select Redundancy Mode:

Master-Backup (Por defecto): LAN1 as master, LAN2 as backup, auto failover upon fault

Load Balance: Both ports work simultaneously for traffic sharing (supported by partial firmware)

  1. Set Switch Back Mode:

Auto: Automatically switch back to master after recovery (Por defecto)

Manual: Stay on backup port; manual switch required after master recovery

  1. Set Detection Interval: Por defecto 1 segundo, adjustable 500ms~10s (1s recommended)
  2. Click Save, redundancy takes effect immediately
  3. Advanced Configuration (Opcional)
ParámetroRecommended ValueDescripción
Heartbeat PacketEnableEnable heartbeat detection for higher fault accuracy
Heartbeat Interval100EMHeartbeat sending interval; shorter = faster detection
Failover Count3Switch only after 3 consecutive failures to avoid false switching
Link Down DetectionEnablePhysical layer link detection (cable disconnection etc.)
  1. Redundancy Function Test
  2. Link Fault Test
  3. Normal status: Web Status → Network Status shows LAN1 Active, LAN2 Standby
  4. Unplug LAN1 cable:

Device indicator: LAN1 off, LAN2 steady on

Web status updates: LAN2 becomes Active, switchover <1s

Verify serial communication via Virtual COM / Modbus TCP, no interruption

  1. Reconnect LAN1 cable:

Auto Mode: LAN1 resumes Active, LAN2 becomes Standby

Manual Mode: Remain on LAN2; manual switch required in Web UI

  1. Switch Failure Test
  2. Power off the switch connected to master port
  3. Device switches to backup port within 1 segundo
  4. Restore master switch power and verify switchback works normally
  5. Solución de problemas comunes
Fenómeno de fallaPossible CauseSolución
Cannot enable redundancyFirmware version too oldUpgrade to latest firmware from official website
Communication interrupted after switchoverWrong backup port IPEnsure master & backup ports same segment with consistent gateway
Frequent false switchingDetection interval too shortExtend interval to 2s, set Failover Count to 5
No auto switch back after master recoverySwitch Back Mode set to ManualChange to Auto or switch manually in Web
Both LAN ports downNetwork configuration conflictCheck duplicate IP and subnet mask settings
  1. Configuration Mnemonic

> Three steps for dual LAN redundancy: set IP first, enable redundancy second;

> Dual switches avoid single point; always verify failover after config.

  1. Hardware Selection: Critical sites choose dual switches; ordinary sites choose single switch dual port
  2. IP Planning: Master and backup ports recommended same network segment for easy management & switchover
  3. Selección de modo: Industrial control prioritizes Master-Backup; data collection can use Load Balance
  4. Switchback Policy: Unattended sites select Auto; manual intervention sites select Manual
  5. Test Validation: Perform link failover test after configuration to ensure reliable redundancy in actual faults

EKI-1526 dual LAN redundancy can be quickly configured via Web interface. The core is enabling redundancy and correctly setting master/backup IP and switchover policy. Cooperating with dual-switch topology, it effectively eliminates single-point faults in industrial networks and ensures high reliability of serial device communication. Full functional verification is recommended after deployment.

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje