Categoría de producto: FS-N40 Series Digital Fiber Amplifier, Cable Outlet Main Unit, NPN Output Core Application: Used with various KEYENCE fiber heads (haz pasante / pensativo) to detect tiny objects, transparent parts, etiquetas, edges and liquid levels. Widely applied in automated production lines, embalaje, semiconductor and 3C equipment. ✅ Model Interpretation FS: Fiber Sensor Series N40: FS-N40 ...

  • Detalles del producto

Categoría de producto: FS-N40 Series Digital Fiber Amplifier, Cable Outlet Main Unit, Salida NPN

Aplicación principal: Used with various clave fiber heads (haz pasante / pensativo) to detect tiny objects, transparent parts, etiquetas, edges and liquid levels. Widely applied in automated production lines, embalaje, semiconductor and 3C equipment.

✅ Model Interpretation

FS: Fiber Sensor Series

N40: FS-N40 amplifier platform

1: Unidad principal (usable standalone, expandable via cascade connection)

norte: NPN open-collector output

Cross-reference within series: FS-N41P (PNP main unit); FS-N42N/N42P are expansion units and cannot work independently.

📋 Especificaciones eléctricas clave

ArtículoEspecificación
Fuente de alimentaciónDC12~24V with reverse polarity protection
Consumo de energía≤870mW in normal operation; power consumption can be reduced in ECO energy-saving mode
Producción1-channel NPN open collector, máximo. 30V; ≤100mA for single unit; ≤20mA under cascade; residual voltage ≤1.4V (@≤10mA)
Fuente de luz4-element red LED, 660Nuevo Méjico
Velocidad de respuesta (multi-speed adjustable)S-HSPD: 23μs / HSPD: 50μs / FINE: 250μs / TURBO: 500μs / SUPER: 1EM / ULTRA: 4EM / MEGA: 16EM / TERA: 64EM
Temperatura ambiente-20℃~+55℃ (sin glaseado)
Inmunidad a la luz ambientalIncandescent lamp ≤20000lx; Sunlight ≤30000lx
AlojamientoPolycarbonate PC, aprox. 78gramo
ProtecciónPolaridad inversa incorporada, output overcurrent and surge protection; mutual interference prevention for multiple units

🛠️ Features

  1. Pantalla digital doble: Real-time indication of received light value + threshold, one-touch AUTO threshold setting, manual fine adjustment available; L-ON/D-ON light-on / dark-on mode switchable.
  2. Multi-speed response: High-speed mode for high-speed production lines with tiny workpieces; low-speed mode provides stronger noise immunity for reflective and transparent materials.
  3. Cascade networking: FS-N41N main unit can be connected in series with FS-N42N expansion units; arriba a 8 units under TURBO mode to save wiring space.
  4. Saturation suppression: Eliminates saturation issues for highly reflective targets to enable stable detection of mirror surfaces and transparent films.
  5. No external input terminal: Pure fiber detection amplifier without external trigger input.

🧩 Compatible Fiber Head Selection (Modelos comunes)

barrera: FT-FM2, FT-FM3, FT-KV840, etc..

Pensativo: FU-35FA, FU-66, FU-77, FU-49, etc..

Fiber heads are sold separately and NOT included with FS-N41N amplifier.

📌 Wiring Definition (4-core cable type)

Marrón: CC 24 V+.

Azul: DC0V

Negro: Salida de señal NPN

Blanco: No usado (empty)

salida NPN: The black wire conducts to 0V when a target is detected; PLC input module shall use sink input.

⚠️ Solución de problemas

  1. Sin pantalla: Check brown/blue power lines, verify voltage and cable damage.
  2. No detection signal: Dirty fiber end face, excessive fiber bending, misaligned fiber head; check L-ON/D-ON mode.
  3. falso disparo: Reduce response speed, enable anti-interference; avoid direct strong ambient light on fiber head; enable saturation suppression for highly reflective targets.
  4. Multiple units mounted adjacently: Activate mutual interference prevention to avoid optical crosstalk.

📎 Alternative / Modelos compatibles

PNP version in same series: FS-N41P

Upgrade series: FS-N10 series; FS-V31 (classic older fiber amplifier with similar functions, different appearance)

Alternativas domésticas: Autonics BF series, Delta fiber amplifiers. Menu logic and response characteristics are not fully identical, program and mounting need re-commissioning.

FS-N40 Full Series Model Comparison Table

Descripción general de la serie: Digital fiber amplifier; Main units work standalone; expansion units must be cascaded after main unit and cannot operate independently.

ModeloTipoProducciónEntrada externaDescripción
FS-N41NUnidad principal, salida de cables1-canal NPNNingunoSalida única, popular model (previous model introduced)
FS-N41PUnidad principal, salida de cables1-channel PNPNingunoSingle output PNP version
FS-N41CUnidad principal, conector m8NPN/PNP switchableNingunoConnector type, not cable outlet
FS-N42NExpansion unit, salida de cables1-canal NPNNingunoSingle output expansion, cascaded with FS-N41N/P
FS-N42PExpansion unit, salida de cables1-channel PNPNingunoSingle output PNP expansion
FS-N43NUnidad principal, salida de cables2-canal NPNSíDual-output main unit with external input terminal
FS-N43PUnidad principal, salida de cables2-channel PNPSíDual-output PNP main unit
FS-N44NExpansion unit, salida de cables2-canal NPNSíDual-output expansion unit
FS-N44PExpansion unit, salida de cables2-channel PNPSíDual-output PNP expansion unit
FS-N40Neutral expansion unitSin salidaSíCascade only, no signal output, used for optical path expansion placeholder

✅ Model Coding Rules

  1. 41 / 43 = Main unit; 42 / 44 / N40 = Expansion unit
  2. 1 = Single output; 3 = Dual output
  3. norte = NPN; P = PNP; C = M8 connector with NPN/PNP switchable

Longitud de cable estándar: 2metro

📌 Cascade Rules

Maximum cascaded quantity: Arriba a 17 units including main unit; dual-output models (43/44) consume 2 unit quotas.

Multiple units installed side by side: Enable anti-interference function to prevent optical crosstalk between adjacent amplifiers.

Fuente de alimentación: Only the first main unit needs DC24V input; subsequent expansion units draw power via side bus.

📊 Quick Selection Guide

Single-point detection for sink-type PLC input: FS-N41N

Single-point detection for source-type PLC input: FS-N41P

Dense multi-point detection to save wiring: Unidad principal + FS-N42N/P expansion

Require 2 independent signal outputs and external input setting: FS-N43N/P

Connector mounting without cable cutting: FS-N41C

📎 Compatible Fiber Head Categories (Universal for FS-N40)

Reflective FU series: FU-35FA / FU-66 / FU-77 / FU-49 / FU-20

Through-beam FT series: FT-FM2 / FT-FM3 / FT-KV840

FS-N41N Application Scenarios

FS-N41N is a NPN single-output main fiber amplifier. Paired with different fiber heads (haz pasante / pensativo / small-spot / side-view), it solves detection tasks in confined spaces, tiny workpieces, transparent materials and high-speed production lines. NPN output is compatible with sink-type PLC inputs.

🏭 Industry Coverage

3electrónica c, semiconductor, embalaje & impresión, batería de litio, alimento & farmacéutico, piezas automotrices, custom automation equipment.

🧩 Typical Detection Applications

  1. Presence / Detección de posición (Más común)

Electronic components: Detect presence/position of resistors, condensadores, papas fritas, connector pins and tiny plastic parts

Embalaje: Check presence of packaging bags, cajas de cartón, caps and labels; missing tablet inspection for blister packs

Transporte de materiales: Workpiece in-position signal on belt/rail to trigger subsequent PLC actions

Recommended fiber: FU-35FA, FU-66 reflective; FT-FM2 through-beam; select S-HSPD 23μs high-speed response for high-speed production lines

  1. Transparente / Semi-transparent Object Detection (Película, MASCOTA, Vaso)

Ordinary photoelectric sensors struggle to distinguish transparent film, plastic bottles, glass sheets and transparent tapes. Fiber sensors capture light transmission variation; enable saturation suppression to resolve saturation for highly reflective surfaces.

Recommended through-beam FT fiber

  1. Edge / Position and Carrier Tape Mark Detection

Edge positioning for FPC, tarjeta de circuito impreso, sprocket holes and marking points on component carrier tape

Color mark detection for labels and printed marks (distinguish light difference between base and mark)

Small-spot fiber FU-49, spot size down to 0.1mm

  1. Cálculo & High-speed Line Sorting

Count workpieces on high-speed conveyor and sort micro components; maximum response 23μs, suitable for production lines with tens of thousands of parts per minute.

  1. Detection in Narrow Cavities & Confined Spaces

Flexible fiber can be routed into molds, jigs and narrow grooves; amplifier body is mounted outside for easy adjustment. M3/M4 threaded fiber heads can be directly locked into jigs.

  1. Non-contact Liquid Level / Powder Level Detection

Detect liquid or powder presence inside transparent pipes and hoppers using through-beam fiber to measure light transmission change through pipe wall.

  1. Automotive Parts, Goma & Low-reflectivity Black Workpiece Detection

For black rubber and matte plastic targets, switch to TERA low-speed high-gain mode to boost light intensity and realize stable detection of low-reflection parts.

⚙️ Cascade Application

Dense multi-point detection: FS-N41N main unit + FS-N42N expansion units cascaded. Only main unit requires power supply. Amplifiers draw power via side bus, reducing 24V wiring and saving DIN rail space inside control cabinet. Anti-interference function must be enabled for closely installed units.

✅ Quick Matching Table

Detection RequirementRecommended Fiber HeadFS-N41N Setup Tips
Tiny workpiece presence, corta distanciaFU-35FAFINE mode, AUTO one-touch setting
Transparent film / bottleFT-FM3 through-beamEnable saturation suppression
High-speed micro part countingFU-49 small spotS-HSPD 23渭s high speed
Black low-reflection workpieceFU-77TERA high gain
Detection inside narrow slotFU-20 side-view fiberReduce gain to avoid false trigger from diffuse reflection

⚠️ Application Limitations

  1. Single unit only supports 1-channel NPN output. Select FS-N43N if dual outputs are required.
  2. No external input terminal, external trigger setting is not supported.
  3. Fiber shall not be sharply bent; minimum bend radius per fiber head datasheet must be followed.
  4. Heavy dust/oil environment: Fiber end face accumulates contamination easily and needs periodic cleaning. Light attenuation warning can be activated for predictive maintenance.

📌 Compatible PLC

Sink input of Mitsubishi FX, Siemens S7-200SMART can directly connect the black NPN signal wire of FS-N41N.