Tipo de producto: Chint NXA Series Intelligent Air Circuit Breaker (ACB) Model Code Definition Segment Code Detailed Description NXA Series Code New generation intelligent air circuit breaker of Chint 32 Frame Size Maximum frame current: 3200A N Mounting Type Fixed Type (W = Draw-out Type) 25 Rated Current Setting rated current In​=2500A MD3 Intelligent Controller MD3 Standard Intelligent Trip ...

  • Detalles del producto

Tipo de producto: Chint NXA Series Intelligent Air Circuit Breaker (ACB)

  1. Model Code Definition
SegmentCódigoDescripción detallada
xaCódigo de serieNew generation intelligent air circuit breaker of Chint
32Tamaño del marcoMaximum frame current: 3200A
norteTipo de montajeFixed Type (W = Draw-out Type)
25Corriente nominalSetting rated current In​=2500A
MD3Controlador inteligenteMD3 Standard Intelligent Trip Controller
AC230Control Supply VoltageShunt closing/opening coil & control circuit power: CA 230 V.
3PAGNúmero de polo3-polo (4P = 4-pole with neutral pole)
2500ACorriente nominalMain body rated operating current: 2500A
  1. Parámetros técnicos básicos
  2. Corriente nominal: $I_n=2500\ \mathrm{A}$
  3. Tamaño del marco: 3200A
  4. Número de polo: 3PAG
  5. Tipo de montaje: Fijado
  6. Control Voltage: CA 230 V.
  7. Tensión nominal de aislamiento: Ui=1000V
  8. Tensión operativa nominal: AC400V / CA690V
  9. Short-Circuit Breaking Capacity @400V:

Ultimate short-circuit breaking capacity $I_{cu}$: ≥85kA

Service short-circuit breaking capacity $I_{cs}$: ≥65kA

  1. Mecánico / Electrical Endurance: Industrial long-life design, suitable for main incoming feeders of power distribution rooms
  2. Functions of MD3 Intelligent Controller

Four-stage protection: Long time delay, short time delay, instantaneous trip and earth fault protection

Monitoring of current, Voltaje, power and energy; fault memory function

Optional communication module (Modbus-RTU) and local LCD display

Protection against overload, cortocircuito, bajo voltaje, phase loss and phase unbalance

  1. Escenarios de aplicación

Low-voltage main incoming switch for industrial workshops, centros comerciales, hospitals and substations

Main protection for generator and transformer outgoing circuits

Large-capacity power distribution and bus tie cabinet

  1. Supplementary Selection Notes
  2. Draw-out version with same specification: NXA32W25-MD3-AC230-3P
  3. 4-pole version available by replacing suffix with 4P
  4. Custom control power supply: DC220V / CA 110 V.
  5. Optional accessories: Electric operating mechanism, locking device, phase barrier, secondary terminal block

Chint NXA Air Circuit Breaker Model List, Comparación entre marcas & Accessory Catalogue

  1. Complete Model Naming Rule

NXA□□□□-□□□-□□□-□P

SegmentCode MeaningOptional ValueExplicación
xaCódigo de serieFijadoChint Kunlun series intelligent air circuit breaker (ACB)
Tamaño del marcoMax frame current16, 20, 32, 40Corresponds to 1600A, 2000A, 3200A, 4000A
Tipo de montajeInstallation formnorte(Fijado), W.(Draw-out)N=Fixed type, W=Withdrawable/draw-out type
Corriente nominalSetting current08~40 (×100A)p.ej. 25=2500A, 20=2000A
Controlador inteligenteTrip unit typeMD3, MD4, MF3, MF4M=Intelligent, D=Standard, F=Power type (with LCD)
Control VoltageOperating powerAC220/230/240, DC220Power for shunt trip, closing coil and control loop
Número de poloMain circuit poles3PAG, 4PAG3-polo / 4-polo (with neutral pole)
  1. Lista completa de modelos (Classified by Frame Size)

2.1 1600un marco (NXA16)

Tipo de montajeCorriente nominalControllerControl VoltagepolacosModelo completo
Fijado (norte)800AMD3AC2303PAGNXA16N08-MD3-AC230-3P
Fijado (norte)1000AMF3AC2304PAGNXA16N10-MF3-AC230-4P
Fijado (norte)1250AMD4DC2203PAGNXA16N12-MD4-DC220-3P
Fijado (norte)1600AMF4AC2304PAGNXA16N16-MF4-AC230-4P
Draw-out (W.)800AMD3AC2303PAGNXA16W08-MD3-AC230-3P
Draw-out (W.)1250AMF4DC2204PAGNXA16W12-MF4-DC220-4P

2.2 2000un marco (NXA20)

Tipo de montajeCorriente nominalControllerControl VoltagepolacosModelo completo
Fijado (norte)1250AMD3AC2303PAGNXA20N12-MD3-AC230-3P
Fijado (norte)1600AMF3AC2304PAGNXA20N16-MF3-AC230-4P
Fijado (norte)2000AMD4DC2203PAGNXA20N20-MD4-DC220-3P
Draw-out (W.)1600AMD3AC2303PAGNXA20W16-MD3-AC230-3P
Draw-out (W.)2000AMF4DC2204PAGNXA20W20-MF4-DC220-4P

2.3 3200un marco (NXA32)

Tipo de montajeCorriente nominalControllerControl VoltagepolacosModelo completo
Fijado (norte)2000AMD3AC2303PAGNXA32N20-MD3-AC230-3P
Fijado (norte)2500AMD3AC2303PAGNXA32N25-MD3-AC230-3P
Fijado (norte)3200AMF4DC2204PAGNXA32N32-MF4-DC220-4P
Draw-out (W.)2500AMD4AC2303PAGNXA32W25-MD4-AC230-3P
Draw-out (W.)3200AMF3DC2204PAGNXA32W32-MF3-DC220-4P

2.4 4000un marco (NXA40)

Tipo de montajeCorriente nominalControllerControl VoltagepolacosModelo completo
Fijado (norte)3200AMD3AC2303PAGNXA40N32-MD3-AC230-3P
Fijado (norte)4000AMD4DC2204PAGNXA40N40-MD4-DC220-4P
Draw-out (W.)3200AMF3AC2303PAGNXA40W32-MF3-AC230-3P
Draw-out (W.)4000AMF4DC2204PAGNXA40W40-MF4-DC220-4P
  1. Cross-Brand Equivalent Comparison (Mainstream ACB)
Chint NXA ModelSchneider MasterpactABB Emax 2Siemens 3WLChangshu CW3Observaciones
NXA16N08-MD3-AC230-3PNW16N1-800AE1N800 R8003WL1116-1AA36-4GA4CW3-1600/800A1600un marco, 800A rated
NXA20N20-MD4-AC230-3PNW20N1-2000AE2N2000 R20003WL2220-1AA36-4GA4CW3-2000/2000A2000un marco, 2000A rated
NXA32N25-MD3-AC230-3PNW32H1-2500AE3N2500 R25003WL3225-1AA36-4GA4CW3-3200/2500A3200un marco, 2500A rated
NXA40N40-MF4-DC220-4PNW40H1-4000AE4N4000 R40003WL4240-1AA36-4GA4CW3-4000/4000A4000un marco, 4000A rated
NXA16W12-MF3-AC230-4PNW16H1-1250AE1N1250 R12503WL1116-1AA36-4GA4CW3-1600/1250ADraw-out type, 4-polo
NXA32W32-MD4-DC220-3PNW32H1-3200AE3N3200 R32003WL3232-1AA36-4GA4CW3-3200/3200ADraw-out type, 3-polo
  1. Intelligent Controller Function Comparison
Controller ModelFunciones de protecciónMonitoring FunctionsComunicaciónMostrarSolicitud
MD34-stage protection: LSI+GBasic current monitoringOptional Modbus-RTUIndicator LEDGeneral power distribution
MD44-stage + over/under voltage, pérdida de fase, unbalanceActual / Voltaje / fuerzaStandard Modbus-RTULED + Digital tubeImportant power distribution
MF34-stage + selective protectionActual / Voltaje / fuerza / energíaOptional Modbus-RTUpantalla LCDComplex distribution system
MF4Protección total + fault early warningFull electrical parameters + event recordStandard Modbus-RTU + Optional ProfinetColor LCDSmart grid & data center
  1. Complete Accessory List (Classified by Function)

5.1 Operation & Control Accessories

Accessory NameModeloFunciónApplicable Range
Viaje de derivaciónNXA-FRemote opening controlFull series, AC230V/DC220V
Under-Voltage TripNXA-UVTUnder-voltage protection (delay optional)Full series, AC230V/DC220V
Closing SolenoidNXA-CERemote closing controlFull series, AC230V/DC220V
Mecanismo de operación eléctricoNXA-MElectric energy storage & traspuestaFull series, for frequent operation
Manual Charging HandleNXA-HManual energy storageFull series, standard equipped
Draw-out Crank HandleNXA-CSpecial for withdrawable breakerDraw-out (W.) serie

5.2 Auxiliar & Alarm Accessories

Accessory NameModeloConfiguración de contactoFunción
Contacto auxiliarNXA-A1/A2/A41/2/4 contactos de cambioStatus indication & circuit expansion
Alarm ContactNXA-B1/B21/2 contactos de cambioFault alarm & signal output
Auxiliar & Alarm CombinationNXA-AB2 auxiliar + 1 alarmaIntegrated status monitoring
Prepaid Trip UnitNXA-PPRemote power cut-offPrepaid system linkage

5.3 Conexión & Mounting Accessories

Accessory NameModeloApplicable FrameFunción
Phase BarrierNXA-IS16/20/32/40Corresponding frameInter-phase insulation protection, standard equipped
Front Connection PlateNXA-CBFull seriesSpecial for front wiring
Rear Wiring KitNXA-RBFull seriesSpecial for rear wiring
Plug-in Connection KitNXA-IBFull seriesInstalación de complementos
DIN Rail BracketNXA-DINFull seriesAuxiliary component mounting

5.4 Seguridad & Interlock Accessories

Accessory NameModeloFunciónSolicitud
Key LockNXA-KLLock on/off statusPrevent misoperation
Cable InterlockNXA-CLDoor-breaker interlockSafety isolation
Linkage InterlockNXA-LLInterlock between two breakersDual power supply switching
Secondary ConnectorNXA-SPSecondary circuit connectionExclusive for draw-out type
Protective CoverNXA-PMPanel protectionA prueba de polvo & impermeable

5.5 Comunicación & Expansion Accessories

Accessory NameModeloProtocolFunción
Modbus-RTU ModuleNXA-MODModbus-RTUMonitoreo remoto & data transmission
Profinet Communication ModuleNXA-PROProfinetIndustrial Ethernet connection
Handheld Test UnitNXA-TESTLocal debuggingParameter setting & diagnóstico de fallas
SD Card Recording ModuleNXA-SDData storageEvent recording & fault analysis
  1. Selección & Procurement Guidelines
  2. Frame Selection: Select 1600/2000/3200/4000A frame according to system maximum current, reserve 10-20% margen.
  3. Tipo de montaje: tipo fijo (norte) for lower cost; draw-out type (W.) for easy maintenance in critical applications.
  4. Controller Selection: MD3 for general use; MD4/MF3 for important facilities; MF4 for intelligent systems.
  5. Configuración de accesorios:

Básico: 1~2 sets of auxiliary contacts, under-voltage trip

Opcional: Electric operation, módulo de comunicación, interlock device

  1. Proceso de dar un título: Comply with GB14048.2 and IEC60947-2, with CE and UL certification.