Chint NM8N-1600SEM 3P 1250A 50kA Moulded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Chint NM8N-1600SEM 3P 1250A 50kA Moulded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

Chint NM8N-1600SEM 3P 1250A 50kA Moulded Case Circuit Breaker

  Model Code Definition Segment Code Detailed Description NM8N Series Code New-generation moulded case circuit breaker (MCCB) of Chint; N stands for upgraded version with higher breaking capacity 1600 Frame Size Maximum frame current: 1600A S Breaking Capacity Grade Standard breaking type, 50el (ultimate short-circuit breaking capacity at 400V) E Trip Unit Type Electronic intelligent trip unit with ...

  • Detalles del producto

 

  1. Model Code Definition
SegmentCódigoDescripción detallada
NM8NCódigo de serieNew-generation moulded case circuit breaker (MCCB) of Chint; N stands for upgraded version with higher breaking capacity
1600Tamaño del marcoMaximum frame current: 1600A
SBreaking Capacity GradeStandard breaking type, 50el (ultimate short-circuit breaking capacity at 400V)
miTipo de unidad de disparoElectronic intelligent trip unit with four-stage protection functions
METROTipo de montajetipo fijo; Opcional: P=Plug-in, D=Draw-out
3PAGNúmero de polo3-polo, for main protection of three-phase circuits
1250ACorriente nominalSetting rated current In​=1250A, long-term stable operating current
50elMáxima capacidad de roturaIcu​=50kA@400V, maximum short-circuit current that can be safely disconnected
  1. Parámetros técnicos básicos
ArtículoValorObservaciones
Corriente nominal (In​)1250AElectronic trip unit adjustable range: 800–1250A
Tamaño del marco1600ACompatible with trip units ≤1600A
Número de polo3PAGMain protection for three-phase three-wire systems
Tipo de montajeFijadoVertical / horizontal mounting available; arriba & bottom incoming line supported
Tensión nominal de aislamiento (Ui​)1000VCumple con IEC 60947-2
Tensión operativa nominal (Ue​)AC400V / CA690VApplicable to power distribution systems of different voltage levels
Ultimate Short-circuit Breaking Capacity (Icu​)50kA@400VStandard S type; Ics​=100%Icu​
Service Short-circuit Breaking Capacity (Ics​)50kA@400VResists multiple short-circuit current impacts
Tipo de unidad de disparoElectronic Intelligent Type (mi)Four-stage protection: gran retraso, breve retraso, instantáneo & falla a tierra
Control VoltageStandard AC230V, optional DC220VPower supply for shunt trip, under-voltage trip and control circuit
Mechanical Endurance≥10.000 vecesIndustrial long-life design
Electrical Endurance≥5,000 timesMaking & breaking capacity under rated current
Temperatura ambiente-40℃ ~ +70℃Adaptable to harsh industrial environments
  1. Core Functions of Electronic Intelligent Trip Unit (E-Type)
  2. Full-range Protection: Accurate four-stage protection including long delay (tiempo inverso), breve retraso (fixed/inverse time), instantaneous trip (fixed time) and earth fault (fixed/inverse time).
  3. Monitoring Function: Real-time monitoring of three-phase current, fault current and operating status, with fault memory.
  4. Adjustable Parameters: Flexible adjustment of protection current and delay time for customized protection in various distribution systems.
  5. Communication Expansion: Optional Modbus-RTU communication module for remote monitoring and data transmission.
  6. Comprehensive Protection Features: Sobrecarga, cortocircuito, bajo voltaje, phase loss and three-phase unbalance protection to prevent equipment damage and electrical fire hazards.
  7. Escenarios de aplicación
  8. Distribución de energía industrial: Incoming/outgoing circuit protection for main distribution cabinets in workshops and production lines; control circuits for large-capacity motors.
  9. Edificios Comerciales: Distribution trunk protection for shopping malls, hoteles, office buildings and large commercial complexes.
  10. Infraestructura: Secondary power distribution protection for hospitals, schools, data centers and other key facilities.
  11. Energy Systems: Low-voltage distribution protection for photovoltaic power stations, wind power systems and substations.
  12. Protección de motores: Overload and short-circuit protection for infrequently started large-capacity motors (bombas de agua, fans, compresores, etc.).
  13. Complete Accessory List (Classified by Function)

5.1 Operation & Control Accessories

Accessory NameModeloFunciónAlcance aplicable
Viaje de derivaciónNM8N-FRemote opening control, AC230V/DC220V optionalFull series; for emergency shutdown and remote control
Under-voltage TripNM8N-UVTDelayable under-voltage protection to avoid equipment damage from undervoltageFull series; essential for critical loads
Closing SolenoidNM8N-CERemote closing control for automatic control systemsFull series; for frequent operation
Mecanismo de operación eléctricoMOD22-M8Electric energy storage, closing & opening to improve operation efficiency1600un marco; suitable for unattended power distribution rooms
External Operating HandleRH11Extended cabinet external operation for safety and convenienceFull series

5.2 Auxiliar & Alarm Accessories

Accessory NameModeloConfiguración de contactoFunción
Contacto auxiliarNM8N-A1/A2/A41/2/4 contactos de cambioCircuit breaker status indication and control circuit expansion
Alarm ContactNM8N-B1/B21/2 contactos de cambioFault alarm signal output and equipment linkage
Auxiliar & Alarm CombinationNM8N-AB2 contactos auxiliares + 1 alarm contactIntegrated status monitoring and space saving
Prepaid Trip UnitNM8N-PPRemote power cut-offLinked with prepaid system for automatic power outage on arrears

5.3 Conexión & Mounting Accessories

Accessory NameModeloApplicable FrameFunción
Phase BarrierNM8N-IS16001600un marcoStandard inter-phase insulation barrier to prevent arc spreading
Front Connection PlateFM221600un marcoDedicated for front wiring; enlarged terminal area for cable connection
Rear Wiring KitNM8N-RB1600un marcoDedicated for rear wiring, suitable for draw-out cabinets
Plug-in BaseNM8N-IB1600un marcoPlug-in installation for easy maintenance and replacement
Terminal Protective CoverNM8N-COVER1600un marcoDustproof and anti-touch protection for wiring terminals

5.4 Seguridad & Expansion Accessories

Accessory NameModeloFunciónSolicitud
Key LockNM8N-KLLock on/off status to prevent misoperationPublic areas and key equipment protection
Padlock DeviceNM8N-LOCKLock circuit breaker at open position for safety isolationEquipment maintenance and overhaul
Communication ModuleNM8N-MODModbus-RTU protocol for remote monitoring and data uploadSmart power distribution and IoT systems
Residual Current Protection ModuleNM8N-LLeakage protection against electric shock and equipment leakage failureHumid environments and densely populated areas
  1. Cross-Brand Equivalent Comparison (Mainstream MCCB)
Chint NM8N ModelSchneider NSXABB Tmax XTSiemens 3VTChangshu CM3Observaciones
NM8N-1600SEM-3P-1250A-50kANSX1600N 1250A Micrologic 5.0XT4S1600 TMD 1250A 50kA3VT8416-1AA03-0AA0CM3-1600H/3340 1250A1600un marco, electronic trip, 50kA breaking
NM8N-1600SPM-3P-1250A-50kANSX1600N 1250A Micrologic 2.0XT4S1600 TMD 1250A 50kA3VT8416-1AA03-0AA0CM3-1600H/3300 1250ATipo de complemento, standard protection
NM8N-1600EDM-3P-1250A-50kANSX1600N 1250A Micrologic 5.0XT4S1600 TMD 1250A 50kA3VT8416-1AA03-0AA0CM3-1600H/3340 1250ADraw-out type, intelligent protection
  1. Selección & Procurement Guidelines
  2. Breaking Capacity Selection: 50kA standard S type for general industrial and commercial distribution; select H type (70el) or HH type (100el) for higher breaking requirements.
  3. Trip Unit Selection: Electronic intelligent E-type for precise protection and remote monitoring; thermal-magnetic T-type for conventional distribution scenarios.
  4. Tipo de montaje: Low-cost fixed type (METRO); replaceable plug-in type (PAG); draw-out type (D) for critical load maintenance.
  5. Configuración de accesorios:

Básico: 1~2 sets of auxiliary contacts and under-voltage trip for basic control and protection.

Opcional: Electric operating mechanism, communication module and residual current module to enhance intelligence and safety.

  1. Cumplimiento de la certificación: Compliant with GB14048.2 and IEC 60947-2, with CE & UL certifications to ensure product quality and operational safety.

Chint NM8N Series MCCB Complete Model List & Price Guide

  1. Complete Naming Rule

NM8N-□□□□-□□-□□-□P

SegmentDefiniciónOptional CodeDescripción
NM8NSerieFijadoChint upgraded MCCB series with enhanced breaking performance
Tamaño del marcoMax frame current125,160,250,400,630,800,1250,1600Covering 125A~1600A rated current
Breaking GradeShort-circuit capacityS(Estándar),h(Alto),R(Current-limiting),q, doS=50kA, H=70kA, R=100kA, Q=120kA, C=150kA@400V
Tipo de viajeProtection modeTM(Thermal-Magnetic), EM(Electrónico)TM: overload inverse time + instantaneous short-circuit; EM: four-stage intelligent protection
Corriente nominalSetting current16~1600AElectronic trip adjustable: 63%~100% of rated current
MontajeInstallation formMETRO(Fijado), PAG(Complemento), D(Draw-out)Universal installation options for cabinet design
Número de poloMain poles1P/2P/3P/4B/4C4B: 4-polo (N non-protected); 4do: 4-polo (N protected)
Breaking CurrentIcu25/36/50/70/100/120/150el400V short-circuit breaking parameter
  1. Full Model List by Frame Size

2.1 125un marco (NM8N-125)

RoturaTripEnMountPoloModeloPrecio de Referencia(Dólar estadounidense)
S(50el)TM63~125AMETRO3PAGNM8N-125S TM 125 M 3P65–80
S(50el)EM80~125AMETRO4doNM8N-125S EM 100 M 4C108–128
h(70el)TM100~125APAG3PAGNM8N-125H TM 125 P 3P90–108
R(100el)EM125AD3PAGNM8N-125R EM 125 D 3P165–205

2.2 250un marco (NM8N-250)

RoturaTripEnMountPoloModeloPrecio de Referencia(Dólar estadounidense)
S(50el)TM160~250AMETRO3PAGNM8N-250S TM 250 M 3P136–160
q(120el)TM125~160AMETRO2PAGNM8N-250Q TM 125 M 2P272–305
h(70el)EM200~250APAG3PAGNM8N-250H EM 250 P 3P233–270
R(100el)EM250AD4doNM8N-250R EM 250 D 4C318–368

2.3 400un marco (NM8N-400)

RoturaTripEnMountPoloModeloPrecio de Referencia(Dólar estadounidense)
S(50el)TM315~400AMETRO3PAGNM8N-400S TM 400 M 3P180–215
do(150el)TM315~400AMETRO3PAGNM8N-400C TM 400 M 3P248–290
h(70el)EM350~400APAG3PAGNM8N-400H EM 400 P 3P330–385
R(100el)EM400AD4doNM8N-400R EM 400 D 4C440–500

2.4 630un marco (NM8N-630)

RoturaTripEnMountPoloModeloPrecio de Referencia(Dólar estadounidense)
S(50el)TM500~630AMETRO3PAGNM8N-630S TM 630 M 3P305–355
h(70el)TM630AMETRO4doNM8N-630H TM 630 M 4C388–445
R(100el)EM500~630APAG3PAGNM8N-630R EM 630 P 3P528–595
do(150el)EM630AD3PAGNM8N-630C EM 630 D 3P665–750

2.5 800un marco (NM8N-800)

RoturaTripEnMountPoloModeloPrecio de Referencia(Dólar estadounidense)
S(50el)TM630~800AMETRO3PAGNM8N-800S TM 800 M 3P430–495
h(70el)EM800AMETRO4doNM8N-800H EM 800 M 4C585–655
R(100el)EM800APAG3PAGNM8N-800R EM 800 P 3P735–820
do(150el)EM800AD3PAGNM8N-800C EM 800 D 3P905–1005

2.6 1250un marco (NM8N-1250)

RoturaTripEnMountPoloModeloPrecio de Referencia(Dólar estadounidense)
S(50el)TM1000~1250AMETRO3PAGNM8N-1250S TM 1250 M 3P665–750
h(70el)EM1250AMETRO3PAGNM8N-1250H EM 1250 M 3P860–960
R(100el)EM1250APAG3PAGNM8N-1250R EM 1250 P 3P1040–1150
do(150el)EM1250AD4doNM8N-1250C EM 1250 D 4C1290–1415

2.7 1600un marco (NM8N-1600)

RoturaTripEnMountPoloModeloPrecio de Referencia(Dólar estadounidense)
S(50el)TM1250~1600AMETRO3PAGNM8N-1600S TM 1600 M 3P905–1005
S(50el)EM1250AMETRO3PAGNM8N-1600S EM 1250 M 3P1220–1350
h(70el)EM1600AMETRO3PAGNM8N-1600H EM 1600 M 3P1450–1610
R(100el)EM1600AD3PAGNM8N-1600R EM 1600 D 3P1795–2010
  1. Special Series

3.1 DC MCCB (NM8NDC)

MarcoActualRoturaPoloModeloPrecio(Dólar estadounidense)
125A100A25el2PAGNM8NDC-125B TM 100 2PAG80–95
400A315A36el3PAGNM8NDC-400C TM 315 3PAG248–290
1600A800A36el3PAGNM8NDC-1600C TM 800 3PAG720–805

3.2 Leakage Protection MCCB (NM8NL)

MarcoActualCorriente de fugaPoloModeloPrecio(Dólar estadounidense)
125A63A500mamá4BNM8NL-125S TM 63 4B RCD2510–550
250A160A2000mamá3PAGNM8NL-250S EM 160 3P RCD4990–1050
400A315A500mamá4doNM8NL-400H EM 315 4C RCD41360–1460
  1. Price Factors & Purchasing Advice

4.1 Price Influencing Factors

FactorPrice FluctuationExplicación
Breaking Grade+20%~+150%Price rises 20%~30% per grade from S to C type
Unidad de viaje+40%~+80%Electronic EM type 40%~80% higher than thermal-magnetic TM type
Tipo de montaje+15%~+40%Plug-in +15%~20%, Draw-out +30%~40% vs fixed type
Número de polo+10%~+50%4-pole 10%~20% higher than 3-pole
Corriente nominal+5%~+30%Higher current within the same frame leads to higher cost
Accesorios+10%~+100%viaje de derivación +10%, under-voltage trip +15%, electric mechanism +80%~100%

4.2 Consejos de selección

  1. Capacidad de ruptura: S(50el) for general use; h(70el) for heavy industrial; R(100el) for key facilities.
  2. Unidad de viaje: TM for conventional distribution; EM for intelligent monitoring and precise protection.
  3. Mounting Solution: Fixed for cost-saving; Plug-in for easy replacement; Draw-out for critical loads.
  4. Proceso de dar un título: Meet GB & IEC standards with CE/UL certification for global project delivery.
  5. Quick Selection Reference
SolicitudModelo recomendadoParámetros clavePrecio(Dólar estadounidense)
Residential DistributionNM8N-125S TM 100 M 3P125un marco, 100A, 50el, 3PAG65–80
Edificio comercialNM8N-250S TM 200 M 3P250un marco, 200A, 50el, 3PAG136–160
Industrial WorkshopNM8N-400H EM 350 M 3P400un marco, 350A, 70el, electronic trip330–385
Large FactoryNM8N-800R EM 800 P 3P800un marco, 800A, 100el, complemento735–820
Centro de datosNM8N-1600C EM 1600 D 3P1600un marco, 1600A, 150el, draw-out1795–2010

Nota: All prices are 2026 April market reference prices. Actual prices vary by purchase quantity, region and distributor. Confirm official quotation from authorized Chint dealers before ordering.

 

Anterior:

Deja una respuesta

Dejar un mensaje