CHINT YBLX-K1/511 Limit Switch

CHINT YBLX-K1/511 (often miswritten as YBLX-K1511) is a universal self-resetting limit switch belonging to the YBLX-K1 series. It is widely used for overtravel protection and position control in industrial automation and machine tools. Parámetros principales & Structure Item Specification Full Model YBLX‑K1/511 (JLXK1/511) Actuator Type Universal type (código “5”) Configuración de contacto 1 NO + 1 ...

  • Detalles del producto

CHINT YBLX-K1/511 (often miswritten as YBLX-K1511) es un universal self-resetting limit switch belonging to the YBLX-K1 series. It is widely used for overtravel protection and position control in industrial automation and machine tools.

  1. Parámetros principales & Structure
ArtículoEspecificación
Modelo completoYBLX‑K1/511 (JLXK1/511)
Actuator TypeUniversal type (código “5”)
Configuración de contacto1 NO + 1 CAROLINA DEL NORTE
Tensión nominalC.A. 380 V, corriente continua 220 V
Corriente nominalAC‑15 0.8 A, DC‑13 0.15 A
Grado de protecciónIP52
StandardsGB/T14048.5, IEC60947‑5‑1
Capacidad de cableado1×(0.5–1) cable mm², stripping length 7–9 mm
Fastening ScrewM3.5, tightening torque 0.8 Nuevo Méjico
Frecuencia de funcionamientoMecánico: 1200 operaciones/hora; Eléctrico: 600 operaciones/hora
Vida útilMechanical ≥ 1,000,000 ciclos; Electrical ≥ 100,000 ciclos
  1. Model Meaning Explanation

Meaning of each part in YBLX-K1/511:

YBLX: General code for limit switch

K1: Quick-action series

/5: Actuator is universal type (actuated from any direction)

/11: Contact combination 1 NO + 1 CAROLINA DEL NORTE

  1. Características principales & Ventajas
  2. Universal actuation design: Actuator senses in 360° directions, suitable for complex installations
  3. Self-resetting: Automatically returns to original position after actuation, no manual reset needed
  4. Silver-alloy contacts: Excellent conductivity, arc resistance, wear resistance, larga vida útil
  5. IP52 protection: Dust-proof and moisture-proof for industrial environments
  6. Instalación flexible: Supports multiple mounting methods for various layouts
  7. Seguro y confiable: Complies with international standards, short-circuit withstand up to 1000 A
  8. Aplicaciones
  9. Machine tools: Table travel limit, automatic reciprocating control
  10. Líneas de producción automatizadas: Material positioning, lifting mechanism limit protection
  11. Lifting machinery: Limit protection, anti-collision control
  12. Maquinaria de embalaje: Posicionamiento, counting control
  13. Maquinaria textil: Yarn tension control, mechanical limit
  14. Other industrial equipment: Motion control, direction/speed change control
  15. Instalación & Wiring Guide

Pasos de instalación

  1. Select proper mounting position to ensure reliable actuation of the actuator
  2. Secure the switch with M4 screws, tightening torque 0.8–1.2 N·m
  3. Connect wires:

NO contact: “turn on at positionin control circuit

NC contact: “turn off at position” (commonly used for emergency stop)

  1. Check actuation direction and reset for sensitive and reliable operation
  2. Power on and test to confirm normal circuit function

Wiring Notes

Cable stripping length: 7–9 mm; avoid too short or too long exposed conductor

Tighten terminals securely to prevent loose connections

Distinguish AC/DC circuits; do not exceed rated voltage/current

Avoid direct control of high-power loads; use an intermediate relay if needed

  1. Operation & Mantenimiento
  2. Regularly check actuator flexibility and reset performance
  3. Clean contact area to remove dust and oil, preventing poor contact
  4. Inspect wire connections for looseness caused by vibration
  5. Avoid overtravel and overfrequency operation to protect internal mechanism
  6. Replace the switch promptly if contact burning, sluggish action, etc.. occur
  7. Reemplazo & Referencia de selección

Other common models in YBLX-K1 series:

YBLX-K1/111: Single roller lever type, 1 NO + 1 CAROLINA DEL NORTE

YBLX-K1/211: Double roller lever type, 1 NO + 1 CAROLINA DEL NORTE

YBLX-K1/311: Plunger type, 1 NO + 1 CAROLINA DEL NORTE

YBLX-K1/411: Roller plunger type, 1 NO + 1 CAROLINA DEL NORTE

  1. Adquisitivo & Warranty Information

Official Order No.: 7101125000000511

CHINT Limit Switch Series List & Cross-Brand Model Cross-Reference

  1. Complete CHINT Limit Switch Series List
SerieCaracterísticasAplicaciones típicasRepresentative Models
YBLX‑K1 / JLXK1Quick‑action, multiple actuators, self‑resettingMachine tools, automationYBLX‑K1/111, YBLX‑K1/511
YBLX‑ME / 8000General purpose, compatible with Schneider XCE mountingMaquinaria general, assembly linesYBLX‑ME/8108, YBLX‑ME/8101
YBLX‑19Roller lever type, various lever configurationsMachine tables, lifting mechanismsYBLX‑19‑111, YBLX‑19‑222
YBLX‑WLWatertight, IP65Outdoor equipment, wet environmentsYBLX‑WL/CA120, YBLX‑WL/CA220
YBLX‑P1Plunger type, short stroke, high frequencyStamping equipment, countersYBLX‑P1/303, YBLX‑P1/120
YBLX‑10Heavy‑duty, high current, metal housingCranes, metalurgiaYBLX‑10/11, YBLX‑10/21
YBLX‑JW2Micro, short stroke, alta sensibilidadPrecision machinery, instrumentsYBLX‑JW2/11Z/3, YBLX‑JW2/22Z
YBLX‑33 / 44Heavy‑duty, high operating force, robustPort machinery, mineríaYBLX‑33/11, YBLX‑44/22
YBLX‑X2Compacto, miniaturizedEquipo pequeño, medical devicesYBLX‑X2/11G, YBLX‑X2/22D
NKX2 / NKX3Modern design, modular mountingSmart factories, automation linesNKX2‑11Z, NKX3‑22Z
YBLXW‑6Microswitch, tamaño pequeño, alta sensibilidadElectronics, home appliancesYBLXW‑6/11DL, YBLXW‑6/22CL
YBLX‑HLHigh temperature resistant, ‑25 ~ +120 °CMetallurgy, drying equipmentYBLX‑HL/11, YBLX‑HL/22
YBLX‑3 / LX3Metal housing, protected designMaquinaria pesada, explosion‑proof areasYBLX‑3/11H, YBLX‑3/22J
  1. Cross-Brand Model Cross-Reference (Major Brands)

2.1 CHINT vs Schneider (Most Common Replacement)

CHINT ModelEquivalent SchneiderNotas
YBLX‑K1/511XCE145Universal actuator, 1 NO + 1 CAROLINA DEL NORTE, compatible mounting
YBLX‑ME/8108XCE102Roller lever, self‑resetting, matching electrical ratings
YBLX‑ME/8101XCE101Plunger type, quick action, same mounting holes
YBLX‑K1/111XCE118Single roller lever, 1 NO + 1 CAROLINA DEL NORTE, similar operating force
YBLX‑19‑111XCE110Straight lever inner actuation, same mounting space
YBLX‑WL/CA120XCKD2120P16Watertight, 2 NO + 2 CAROLINA DEL NORTE, IP65

2.2 CHINT vs Siemens

CHINT ModelEquivalent SiemensNotas
YBLX‑K1/5113SE5 112‑0CH01Universal, 1 NO + 1 CAROLINA DEL NORTE, mechanical life ≥ 1M cycles
YBLX‑ME/81083SE5 100‑0CH02Roller lever, self‑resetting, compatible mounting
YBLX‑19‑2223SE5 122‑0CH01Forked double roller lever, bidirectional limit
YBLX‑P1/3033SE5 212‑0CH01Long plunger, short stroke, high frequency
YBLX‑WL/CA2203SE5 232‑0CH01Watertight, 3 NO + 3 CAROLINA DEL NORTE, outdoor use

2.3 CHINT vs ABB

CHINT ModelEquivalent ABBNotas
YBLX‑K1/111LS31K01Single roller lever, 1 NO + 1 CAROLINA DEL NORTE, matching ratings
YBLX‑ME/8108LS31K10Roller lever, self‑resetting, same mounting position
YBLX‑19‑131LS31K20Straight lever groove actuation, consistent precision
YBLX‑P1/120LS31K30Short plunger, quick action, similar response

2.4 CHINT vs Omron

CHINT ModelEquivalent OmronNotas
YBLX‑K1/511D4V‑8108SZUniversal, 1 NO + 1 CAROLINA DEL NORTE, operating force 0.5–1.5 N
YBLX‑ME/8108D4V‑8166ZRoller lever, self‑resetting, mechanical life ≥ 1M cycles
YBLX‑WL/CA120D4V‑8122ZWatertight, 2 NO + 2 CAROLINA DEL NORTE, IP65
YBLXW‑6/11DLD4V‑2120ZMicroswitch, short roller lever, 1 NO + 1 CAROLINA DEL NORTE
  1. Key Points for Replacement & Selección
  2. Mounting compatibility: Prefer models with identical mounting dimensions (p.ej., YBLX-ME ↔ XCE) for direct replacement
  3. Electrical matching:

Tensión nominal: C.A. 380 V / corriente continua 220 V

Corriente nominal: AC-15 0.8 A, DC-13 0.15 A

Contactos: 1 NO + 1 CAROLINA DEL NORTE (estándar), 2 NO + 2 CAROLINA DEL NORTE (special)

  1. Actuator type matching:
Actuator TypeCHINT CodeInternational Equivalent
Universal5XCE145, 3SE5 112 serie
Single roller lever1XCE118, 3SE5 100 serie
Double roller lever2XCE110, 3SE5 122 serie
Plunger3XCE101, 3SE5 101 serie
Roller plunger4XCE103, 3SE5 103 serie
  1. Protection level selection:

General environment: IP52 (YBLX-K1)

Humid environment: IP65 (YBLX-WL)

Outdoor use: IP67 (custom models)

  1. Selección & Recomendaciones de reemplazo
  2. Prefer direct series replacement: YBLX-ME ↔ XCE, YBLX-K1 ↔ 3SE5 are most reliable
  3. Contact count: Ensure NO/NC quantity matches to avoid logic errors
  4. Mechanical parameters: Match operating force, travel, reset speed to prevent misoperation
  5. Special environment adaptation:

Exterior / wet: YBLX-WL (IP65)

Temperatura alta: YBLX-HL (-25 ~ +120 °C)

Explosion-proof: YBLX-3 (metal housing, certified)