Especificaciones técnicas & Application Guide Product Overview Schneider LUCA32BL is a standard control unit from the TeSys Ultra series (formerly TeSys U series), a component of three-phase motor starters. It must be used with LUB series power bases (such as LUB32 / LUB38) to form a complete motor starting and protection system. It features thermal-magnetic ...

  • Detalles del producto

Especificaciones técnicas & Application Guide

  1. Descripción general del producto

Schneider LUCA32BL is a standard control unit from the TeSys Ultra series (formerly TeSys U series), a component of three-phase motor starters. It must be used with LUB series power bases (such as LUB32 / LUB38) to form a complete motor starting and protection system. It features thermal-magnetic protection and is suitable for industrial applications requiring basic motor protection including overload, cortocircuito, pérdida de fase, phase imbalance, y protección de falla a tierra.

  1. Parámetros técnicos básicos
ArtículoEspecificaciónDescripción
Tipo de productoStandard Control UnitFor TeSys Ultra series motor starters
Voltaje de control24 VCCCoil supply voltage, requires separate external power supply
Rango de configuración actual8 A ~ 32 AAdjustable overload protection range
Voltaje del circuito principalArriba a 690 VACACIONESFor three‑phase power systems
Clase de protecciónClase 10Trip time approx. 20 se sentó 1.5 × corriente nominal
Potencia del motor adecuada15 kilovatios (400 V) / 18.5 kilovatios (690 V)For three‑phase self‑cooled motors
Frecuencia de funcionamiento40–60 HzCompliant with global power grid standards
Temperatura de funcionamiento-25 °C ~ +70 °CAmplio rango de temperatura para entornos industriales.
AprobacionesUL 508, CSA C22‑2, CEI/EN, CCCMeets international and Chinese standards
  1. Características
  2. Protección Integral: Sobrecarga, cortocircuito, pérdida de fase, phase imbalance, y protección de falla a tierra
  3. Reinicio manual: Enables quick restart after fault clearance
  4. Modbus Communication: Supports configuration and data transfer for remote monitoring and diagnostics
  5. Montaje flexible: Compatible with various TeSys Ultra power bases
  6. Alta compatibilidad: Suitable for utilization categories AC-41 / AC-43 / AC-44
  7. Diseño compacto: Saves cabinet space and increases mounting density
  8. Aplicaciones

General machinery including fans, zapatillas, y compresores

Industrial line equipment such as conveyors and mixers

Small factory automation systems

Applications requiring basic motor protection with 24 VDC control signals

Replacement for traditional thermal relay + contactor combinations, offering more reliable protection and easier installation

  1. Operating Instructions
  2. Requisito de instalación: Must be used with a matching LUB series power base with correct electrical connections
  3. Reglas de cableado: Stable 24 VDC supply for control circuit; three-phase power for main circuit
  4. Recomendación de configuración: Adjust overload setting according to motor rated current within 8 A–32 A
  5. Maintenance Note: Regularly check control unit status to ensure proper protection operation
  6. Communication Setup: Configure Modbus parameters per manual if communication is required
  7. Información de compatibilidad

Compatible Power Bases: TeSys Ultra series including LUB32 (32 A), LUB38 (38 A)

Reemplazo: Can replace some traditional thermal relay + contactor assemblies with an integrated solution

Ruta de actualización: For advanced functions such as built-in soft starting and energy monitoring, consider TeSys T or TeSys Giga series

The Schneider LUCA32BL is a cost-effective standard motor control unit. Con su diseño compacto, protección integral, y amplia compatibilidad, it is an ideal choice for starting and protecting three-phase motors in industrial automation, especially for cost-sensitive applications requiring basic protection.

TeSys Ultra (formerly TeSys U) Standard Control Unit Range & Power Bases

  1. Complete List of Standard Control Units (LUCA Series)

TeSys Ultra standard control units use thermal-magnetic protection and provide overload, cortocircuito, pérdida de fase, phase imbalance, y protección de falla a tierra. They are only compatible with standard power bases (Serie LUB) and not with advanced bases (LUBxxx0 series). All models are Class 10, 3-polo (3PAG) three-phase devices.

Rango de configuración actual24 VCC48–72 V AC/DC110–240 V AC/DC24 VACACIONESPotencia del motor (400 V)
0.35–1.4 ALUCA1XBLLUCA1XES-LUCA1XB0.75 kilovatios
1.25–5 ALUCA05BLLUCA05ESLUCA05FULUCA05B2.2 kilovatios
3–12 ALUCA12BLLUCA12ESLUCA12FULUCA12B5.5 kilovatios
4.5–18 ALUCA18BLLUCA18ESLUCA18FULUCA18B7.5 kilovatios
8–32 ALUCA32BLLUCA32ESLUCA32FULUCA32B15 kilovatios

Convención de nomenclatura de modelos

LUC: Prefix for TeSys Ultra control units

A: Unidad de control estándar (Advanced versions: C/D/M)

XX: Current range code (1X = 0.35–1.4 A, 05 = 1.25–5 A, 12 = 3–12 A, 18 = 4.5–18 A, 32 = 8–32 A)

Sufijo: BL = 24 VCC, ES = 48–72 V AC/DC, FU = 110–240 V AC/DC, B = 24 VACACIONES

  1. Complete List of Power Bases (LUB Series)

TeSys Ultra power bases are divided into standard bases (sin sufijo) and advanced bases (sufijo 0), both 3P three-phase, for different control unit types.

2.1 Standard Power Bases (For LUCA Series Standard Control Units)

ModeloCorriente nominalTensión nominalContactos auxiliaresCompatible Control UnitsMax Motor Power (400 V)
LUB1212 A690 VOpcionalLUCA1X / LUCA05 / LUCA125.5 kilovatios
LUB3232 A690 VOpcionalFull LUCA series15 kilovatios
LUB3838 A690 VOpcionalFull LUCA series18.5 kilovatios

2.2 Advanced Power Bases (For LUCC / LUCD / LUCM Advanced Control Units)

ModeloCorriente nominalTensión nominalContactos auxiliaresCompatible Control UnitsMax Motor Power (400 V)
LUB12012 A690 V1NO + 1CAROLINA DEL NORTELUCC/LUCD/LUCM (1.25–12 A)5.5 kilovatios
LUB32032 A690 V1NO + 1CAROLINA DEL NORTELUCC/LUCD/LUCM (full range)15 kilovatios
LUB38038 A690 V1NO + 1CAROLINA DEL NORTELUCC/LUCD/LUCM (full range)18.5 kilovatios

2.3 Reversing Power Bases (For Reversing Control Units)

ModeloCorriente nominalTensión nominalCompatible Reversing Control UnitsMax Motor Power (400 V)
LU2B1212 A690 VLU2A1X / LU2A05 / LU2A125.5 kilovatios
LU2B3232 A690 VFull LU2A series15 kilovatios
LU2B3838 A690 VFull LU2A series18.5 kilovatios
  1. Key Matching Rules
  2. Standard Control Unit (LUCA) + Standard Base (LUBxx): Basic motor protection with thermal-magnetic protection and standard control
  3. Advanced Control Unit (LUCC/LUCD/LUCM) + Advanced Base (LUBxx0): Premium protection with diagnostics, comunicación, y funciones ampliadas
  4. Control unit current range ≤ base rated current: p.ej., LUCA32BL (8–32 A) may only be used with LUB32 (32 A) or LUB38 (38 A), not LUB12 (12 A)
  5. Control voltage is independent of main voltage: Control unit powered via terminals A1/A2 on the base, típicamente 24 VDC/AC, 48–72 V AC/DC, or 110–240 V AC/DC
  6. Notas de aplicación
  7. Montaje: Control unit plugs directly into power base and locks with a clip; no additional tools required
  8. Protección: Basic protection including Class 10 sobrecarga, cortocircuito (13 × Ir max), phase imbalance, pérdida de fase, and earth fault (equipment protection)
  9. Comunicación: Soporta Modbus (with optional communication module) for remote monitoring and diagnostics
  10. Ambiente: Temperatura de funcionamiento -25 °C ~ +70 °C, suitable for most industrial environments

La combinación de unidades de control estándar TeSys Ultra (Serie LUCA) y bases de poder (Serie LUB) Proporciona una solución flexible y confiable para arranque y protección de motores., covering three-phase motors from 0.75 kW a 18.5 kilovatios. Selection should be based on motor rated current, voltaje de control, and protection requirements to ensure safe and stable operation.