Relé de estado sólido monofásico OMRON G3PA-240B-VD - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Relé de estado sólido monofásico OMRON G3PA-240B-VD - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

eléctrico/

Relé de estado sólido monofásico OMRON G3PA-240B-VD

Omron single-phase SSR, integrated heat sink, Montaje en carril DIN, zero-crossing type ✅ Model Code Explanation G3PA: G3PA series solid state relay with integrated heat sink 2: Output voltage class AC24~240V 40: Rated output current 40A B: Built-in heat sink, screw terminals VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light 📋 Key Specifications ...

  • Detalles del producto

Omrón single-phase SSR, integrated heat sink, Montaje en carril DIN, zero-crossing type

✅ Explicación del código del modelo

G3PA: Serie G3PA solid state relay with integrated heat sink

2: Output voltage class AC24~240V

40: Rated output current 40A

B: Built-in heat sink, terminales de tornillo

enfermedad venérea: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light

📋 Especificaciones clave

Lado de entrada (Terminales de control A1/A2)

Tensión de entrada nominal: DC 5~24V

Rango de voltaje de funcionamiento: DC 4~30V

máx.. corriente de entrada: 7mamá (25℃)

voltaje de captación: ≤DC4V; voltaje de caída: ≥DC1V

Lado de salida (Terminales de carga)

Load voltage: CA24~240V, permissible range AC19~264V (50/60Hz)

Corriente nominal: 40A @40℃; derate to 36A when tightly mounted side by side

Surge current withstand: 440A (60Hz, 1 ciclo)

On-state voltage drop: ≤1.6V RMS

Corriente de fuga: ≤20mA@AC200V

Trigger mode: Zero-cross switching (ideal for heating loads to reduce interference)

Aislamiento: Phototriac

Funcionar / tiempo de liberación: ≤ half cycle +1ms

Ambiental & Mecánico

Montaje: Carril DIN / montaje con tornillos

Temperatura ambiente: -30~+80℃ (sin condensación ni formación de hielo)

Rigidez dieléctrica: CA 4000 V 1 min.; resistencia de aislamiento ≥100MΩ (CC 500 V.)

Terminales: Terminales de tornillo

Certificaciones: UL, cUL, VDE, CE

📌 Aplicaciones típicas

Tubos calefactores eléctricos, hornos industriales, calentamiento por moldeo por inyección, equipo de aire caliente, Control de temperatura ON/OFF para cargas resistivas monofásicas. No apto para PWM de alta frecuencia, sólo para conmutación periódica de cruce por cero.

⚠️ Notas importantes

  1. Utilice una clasificación de 40 A para cargas resistivas; cargas inductivas (motores, transformadores) requieren una fuerte reducción de potencia.
  2. Cuando varias unidades están instaladas firmemente una al lado de la otra, Reduzca la corriente a 36 A debido a una mala disipación de calor..
  3. Tipo de cruce por cero: Se enciende y apaga solo cuando el voltaje de CA cruza cero.. Suprime la EMI pero no puede cambiar en ángulos de fase aleatorios.
  4. Entrada CC no polarizada; Puede ser controlado directamente por PLC o controlador de temperatura con salida DC5-24V..
  5. SSR no tiene contactos mecánicos y no puede proporcionar protección contra cortocircuitos.. Se debe instalar un fusible aguas arriba.

🔁 Misma serie & Modelos alternativos

G3PA-220B-VD: 20A / CA24-240V / DC5-24V

Director ejecutivo de G3PA-260B: 60A / CA24-240V / DC5-24V

G3PA-420B-VD: 20A / CA200-400V / 12-24 V CC

Alternativas domésticas: 40Un SSR de cruce por cero con disipador de calor integrado. Verifique la curva de reducción y el índice de sobretensión antes del reemplazo.

Director General de G3PA-240B (cruce por cero, 40A, SSR controlado por CC de 5 a 24 V) Escenarios de aplicación

Posicionamiento central: Control de temperatura ON/OFF para cargas resistivas monofásicas de 24 a 240 V CA. Disipador de calor integrado en carril DIN, impulsado por controladores de temperatura o PLC. Diseñado principalmente para cargas de calefacción., cruce por cero para baja EMI, capaz de cambiar frecuentemente. No apto para PWM de alta frecuencia o cargas inductivas como motores.

🔥 Calefacción & Control de temperatura (Uso primario)

  1. Hornos industriales, hornos de circulación de aire caliente, cámaras de envejecimiento, gabinetes de temperatura constante, cámaras de prueba de alta y baja temperatura (tubos de calefacción eléctrica, tubos calefactores de cuarzo)
  2. Calentamiento del barril de moldeo por inyección, calentamiento del troquel extrusor, Calefacción de zona de la máquina de moldeo por soplado
  3. Máquinas de prensado en caliente, máquinas de estampación en caliente, máquinas de transferencia de calor, placas calefactoras para laminadoras
  4. Maquinaria de embalaje: selladores de calor, cuchillos de corte caliente, calentamiento por túnel retráctil
  5. Maquinaria alimentaria: lineas de horneado, secadores de aire caliente, Calentamiento eléctrico para cocinar salsa., hornos comerciales
  6. Tratamiento de agua: calderas de calefacción eléctrica, calentamiento del tanque, calefacción de trazas de tuberías, calefacción de descongelación
  7. maquinas vulcanizadoras, Circuitos de calefacción monofásicos para controladores de temperatura de moldes.. (Para calefacción trifásica, usar 3 unidades por separado para cada fase.)

🧪 Equipos de automatización

  1. Cámaras de pruebas ambientales, temperatura constante & maquinas de humedad, secciones de calefacción eléctrica de deshumidificadores
  2. Semiconductor / producción de PCB: líneas de secado, estaciones de precalentamiento para revestimiento de cola
  3. Equipo de batería de litio.: hornos de vacío, calefacción del gabinete de formación
  4. Impresión textil & tintura: maquinas de ajuste, cuartos de secado, calentamiento del rodillo caliente
  5. maquinas de imprimir: túneles de secado, calefacción auxiliar para sistemas UV

💡 Otra conmutación de carga resistiva

  1. Lámparas halógenas de alta potencia., bancos de lámparas de calefacción por infrarrojos (cargas de lámpara resistivas)
  2. Calefactores eléctricos de alta potencia para armarios y salas blancas.
  3. Módulos de calefacción auxiliar eléctricos para aire acondicionado. / sistemas de aire fresco

Ventaja: Zero-cross switching reduces inrush current and interference to temperature instruments, PLCs and power grid.

✅ Suitable Working Conditions

Cambio frecuente (several to tens of times per minute), avoid contact burnout and arcing of contactors

Driven by PID temperature controllers or PLC digital outputs (CC 24 V)

DIN rail installation inside control cabinets, compact space, disipador de calor incorporado, no extra heat sink required

Alto aislamiento (4kV rigidez dieléctrica) and operation indicator for easy commissioning

Single-phase resistive heating loads, principalmente AC220V, current ≤40A (derate to 36A when densely mounted)

❌ Aplicaciones no recomendadas (Errores de selección)

AC motors, bombas de agua, transformers and other inductive loads: high starting surge may cause breakdown. Heavy derating or random-phase SSR / contactor is preferred.

High-frequency PWM dimming (tens of Hz or above): zero-cross SSR cannot perform phase-angle regulation.

Cargas capacitivas.

OMRON G3PA-240B-VD Selection Guide & Notas de aplicación (Product Page Version, Chino + Inglés)

Optimizado para la web de comercio exterior de bestcontactor, legible para ingenieros, compradores y adquisiciones, Cumple con E-E-A-T.

  1. Lista de verificación de selección: confirme la 4 Elementos antes de elegir G3PA-240B-VD

✅ Tipo de carga: Se prefiere carga resistiva monofásica (tubos de calentamiento, calentadores infrarrojos, placas calefactoras)

✅ Tensión de carga: CA 24~240V (AC220V más común)

✅ Señal de control: DC 5~24V (PLC HACER, Salida del controlador de temperatura PID)

✅ Montaje: Carril DIN dentro del gabinete, integrated heat sink

Si no está satisfecho: alternativas recomendadas

  1. Cargas inductivas (motores, válvulas solenoides, transformadores)

No recomendado para este modelo.. Utilice contactores o SSR de fase aleatoria con al menos 50% reducción de potencia actual.

  1. 3-cargas de calefacción de fase

Solución: 3 Unidades G3PA-240B-VD para controlar cada fase de forma independiente.. No utilice una unidad para carga trifásica..

  1. Regulación de potencia, atenuación del ángulo de fase, PWM de alta frecuencia

G3PA es SSR de cruce por cero, sólo para control de ciclo ON/OFF, no modulación de ángulo de fase. Choose OMRON G3PW power controllers if regulation is needed.

  1. Load current near 40A continuously, multiple units tightly arranged

Derate to 36A for dense mounting. Upgrade to G3PA-260B-VD (60A) if load current is continuously above 36A.

Load Current Formula (for foreign trade page)

Safe current for resistive load = rated load current × 1.25 margen de seguridad

Multiply by 0.9 derating factor if densely mounted

Ejemplo: 3000W @AC220V heating tube, current ≈13.6A, sufficient margin for G3PA-240B-VD.

  1. Guía de cableado (Concise for Product Page)

Aporte (control): A1, A2, DC5~24V, no polarizado

Producción (carga): power in, load out; AC side non-polarized

Built-in operation indicator: lights up when control signal is present for easy on-site commissioning

Clasificación de aislamiento: AC4000V between input and output

Importante: Fast fuse must be installed on upstream AC side. SSR cannot withstand short circuit and will be permanently damaged.

  1. Notas de aplicación
  2. Disipación de calor & Reducción de potencia

This model has integrated heat sink. La disipación de calor empeora a temperaturas altas del gabinete o cuando se montan estrechamente uno al lado del otro.; nominal 40A se reduce a 36A. Mantenga la ventilación dentro del gabinete. Está prohibida la instalación sellada sin flujo de aire..

  1. Característica de cruce por cero

El SSR se enciende y apaga solo cuando el voltaje de CA cruza cero. Beneficios: baja corriente de entrada y baja EMI. Limitación: no puede cambiar en un ángulo de fase arbitrario, no para atenuación o control de fase.

  1. Corriente de fuga

Pequeña corriente de fuga residual (≤20mA @CA200V) existe en estado APAGADO. Las cargas pequeñas pueden mostrar un ligero calentamiento o brillo., lo cual es normal para SSR. Se puede agregar una resistencia de purga para resolver este problema..

  1. Sobretensión de carga

Las lámparas infrarrojas y los tubos de cuarzo tienen una baja resistencia al frío y una alta corriente de entrada al encenderse.. Este modelo soporta 440A (60Hz, 1 ciclo). Seleccione una clasificación de corriente más alta si la sobretensión excede este valor.

  1. Condiciones ambientales

Temperatura de funcionamiento: -30℃ ~ +80℃, sin gas corrosivo, condensación o acumulación de polvo. El polvo y el aceite obstruirán el disipador de calor y acelerarán el envejecimiento..

  1. Operaciones prohibidas

No pruebe el cortocircuito de salida; no utilizar directamente para cargas capacitivas; Evite cargas inductivas que surjan con frecuencia..

  1. Artículos de apoyo recomendados

Fusible: fusible rápido de cerámica

Controlador de temperatura: Omron E5CC / Controlador PID E5EC

Modelos alternativos: G3PA-220B-VD (20A), Director ejecutivo de G3PA-260B (60A)

Actualización para regulación de potencia.: Controlador de potencia serie G3PW

  1. Preguntas frecuentes (para la parte inferior de la página del producto)

q: ¿Puede G3PA-240B-VD controlar motores??

A: No recomendado. El SSR de cruce por cero tiene una resistencia limitada a sobretensiones y puede fallar bajo la corriente de arranque del motor.. Se prefiere el contactor de CA.

q: ¿Por qué el tubo calefactor todavía está ligeramente caliente después de que se apaga el SSR??

A: Es causado por una corriente de fuga inherente del SSR., más obvio en cargas pequeñas. Agregar una resistencia de purga.

q: ¿Se puede controlar directamente mediante una salida PLC DC24V??

A: Sí. El consumo de energía de entrada es bajo (aprox. 7mamá), Los puntos de salida PLC estándar pueden controlarlo..

Relé de estado sólido OMRON SSR serie completa (Versión de Selección de Comercio Exterior, Clasificado, incluyendo G3PA)

Clasificación: Disipador de calor integrado tipo carril DIN (Primera elección para calefacción de armarios.), tipo de disipador de calor separado, detección de fallas SSR, SSR miniatura de E/S enchufable, controlador de potencia (RSS no regular, a menudo seleccionados juntos), modelos descatalogados marcados.

  1. Disipador de calor integrado Riel DIN SSR (Más común para calefacción, incluyendo G3PA)
  2. G3PA (Tipo integrado delgado, módulo de potencia reemplazable)

Monofásico, 24-240 V CA / 200–480 V CA, Control de 5 a 24 VCC, zero-crossing

G3PA-210B-VD: 10A

G3PA-220B-VD: 20A

Director General de G3PA-240B: 40A (este modelo)

Director ejecutivo de G3PA-260B: 60A

G3PA-420B-VD: 20A, Versión AC480V

Director ejecutivo de G3PA-430B: 30A, Versión AC480V

G3PA-450B-VD-2: 50A, Versión AC480V

✅ Uso típico: hornos, calentamiento por moldeo por inyección, máquinas de temperatura del molde, Control de temperatura PID ON/OFF

  1. G3PE (Nuevo tipo compacto integrado, monofásico & 3-fase)

Monofásico: G3PE-215B / 225B / 235B / 245B; 3-fase G3PE-325B, G3PE-345B

Ventajas: mejor tolerancia a sobretensiones, versión de fase aleatoria disponible, Adecuado para algunas cargas inductivas y atenuación.

Montaje: Carril DIN, monofásico / 3-circuitos de calefacción de fase

  1. G3PJ (Tipo de montaje denso y de baja temperatura, 25Una calificación sigue siendo válida incluso 3 unidades firmemente una al lado de la otra)

G3PJ-225B, G3PJ-225B-PU (Terminal de resorte a presión)

Para armarios de control de alta densidad con calefacción multizona

  1. G3PH (Tipo integrado de alta corriente)

75A / 150A, CA240V, CA480V, for heavy heating loads

  1. G3PC (SSR with built-in fault detection)

Heater break detection and SSR short-circuit alarm output. Safety-critical heating control, preferred for test chambers and lithium battery ovens.

  1. G3PF (Smart CT current sensing SSR)

Built-in current transformer for real-time heating element break and short-circuit detection. For high-end equipment with alarm logging.

  1. Separate Heat Sink Type (No built-in heat sink, embedded installation, external heat sink required)
  2. G3NA (Classic universal model, large market stock)

Monofásico, 5A~90A, mainly zero-crossing

G3NA-205B / 210B / 220B / 240B / 260B

G3NA-410B / 420B / 440B / 460B (CA480V)

G3NA-290B (90una corriente alta)

Sufijo: -VD = DC5–24V control; models without B are random-phase type

  1. G3NE (Economical low-current, 5A/10A/20A, quick connect terminals)

Bajo costo, small heating loads, lámparas infrarrojas, embedded inside machines

  1. Complemento / I/O Mini SSR (Same footprint as MY/LY relays, signal and small load switching)

G3F / G3FD: MY relay size, socket mount, small AC/DC loads

G3H / G3HD: LY power relay size

G3R-I/O: G2R footprint I/O isolation SSR

G3RV-ST: 6.2mm slim DIN rail I/O SSR, high-density PLC isolation output

G3TA: SSR matched with G7TC I/O terminal blocks

G3RZ: MOSFET type, AC/DC low-power loads

  1. Power Controllers (Power regulators, not regular ON/OFF SSR)

Phase angle control, control de ciclo, soft start, for continuous power regulation

G3PW: Single-phase power controller (widely used for regulation instead of SSR)

G3ZA: Multi-channel power controller

G32A-EA: Cycle control unit

  1. PCB Mount SSR (Soldered on PCB, conmutación de señal)

G3S, G3M, G3DZ, G3TB etc. Baja corriente, aislamiento de señal, used inside control boards

  1. Modelos discontinuados (Frequently asked in foreign trade inquiries)

G3PB, G3NH, G3B/G3BD, old G3RV-SR. Not recommended for new designs; only for spare replacement.

✅ Quick Selection Table (Can be placed directly on product page)

SerieHeat Sink TypeRango actualCaracterísticas claveAplicaciones típicas
G3PAIntegrated DIN rail10~60ADelgado, zero-crossing, replaceable power coremoldeo por inyección, hornos, general heating
G3PEIntegrated DIN railSoltero / 3-phase 15~45ABetter surge resistance, random-phase optionCalefacción, partial inductive loads
G3PJIntegrated DIN rail25ANo derating when densely mountedMulti-zone dense control cabinets
G3PHIntegrated DIN rail75/150AExtra high currentHigh-power heating
G3PC / G3PFIntegrated DIN rail25~45AFault detection & alarmaLithium battery ovens, cámaras de envejecimiento, safety-critical equipment
G3NASeparate heat sink5~90AUniversal, rentableEmbedded inside machines, external heat sink required
G3NESeparate heat sink5~20AEconómicoLow-power heating
G3PWPower regulator–Fase / cycle power controlContinuous temperature regulation

📌 Suffix Meaning (FAQ for Foreign Trade)

enfermedad venérea: DC5~24V non-polarized DC input (G3PA-240B-VD uses this suffix)

B: Zero-crossing trigger

No B: Random-phase trigger (phase-angle switching, adecuado para cargas inductivas)

PU: Terminal de resorte a presión

-2: 480versión V