| Segmento de modelo | Descripción |
| FR | General prefix for Mitsubishi inverters (Frequency Inverter) |
| A840 | Standard model of A800 series for 400V class, high-performance vector control for general industrial use |
| 2600 | Capacity code, corresponding to Normal Duty (ND) 90kW/180A, Super Light Duty (SLD) 132kW/260A |
| 2 | CA type (current control, standard 0–20mA analog input) |
| 60 | Conformal coating on circuit boards, non-plated conductors, enhanced environmental resistance |
- Core Electrical Specifications
| Artículo | Normal Duty (ND) | Super Light Duty (SLD) | Light Duty (LD) |
| Potencia del motor aplicable | 90kilovatios (150caballos de fuerza) | 132kilovatios (177caballos de fuerza) | 110kilovatios (147caballos de fuerza) |
| Corriente de salida nominal | 180A | 260A | 216A |
| Potencia de entrada | 3-phase AC 380–480V, 50/60Hz (±10% tolerance) | ||
| Voltaje de salida | 3-phase AC 0–input voltage, proportional to input voltage | ||
| Frecuencia de salida | 0.2–590Hz (max 400Hz in vector control mode) | ||
| Método de control | Control vectorial sin sensores (RSV), Control V/F, PM Sensorless Vector Control, compatible with Induction Motors (IM) and Permanent Magnet Motors (IPM) | ||
- Características clave
- High‑Performance Control
Universal vector control, high torque at low speed; 150% par nominal a 0,5 Hz
Built-in PID controller for various closed-loop applications
Automatic energy-saving operation, adjusts output voltage according to load to reduce power consumption
- Structure & Protección
Protection class IP00 (open type), suitable for cabinet mounting
Circuit boards with conformal coating (Cumple con IEC 60721-3-3), resistant to dust, aceite, and humidity
Protección integral: sobrecorriente, sobretensión, subtensión, calentamiento excesivo, falla a tierra, motor overload, phase loss protection, etc..
- Built-in Interfaces & Expandability
Standard RS-485 communication (Modbus RTU protocol)
Supports various fieldbus extensions: PROFIBUS-DP, DispositivoNet, EtherNet/IP, etc..
Analog inputs: 2 canales (0–10V / 0–20mA, 1 channel dedicated for CA-type 0–20mA)
E/S digitales: 5 inputs, 2 outputs (ampliable)
- Capacidad de sobrecarga & Parámetros ambientales
| Tipo de carga | Capacidad de sobrecarga | Condiciones ambientales |
| Normal Duty (ND) | 150% rated current for 60s, 200% rated current for 3s (inverse-time characteristic) | Operating temp: -10℃to 50℃C (derating above 40℃C) |
| Super Light Duty (SLD) | 110% rated current for 60s, 120% rated current for 3s | Storage temp: -20℃ to 65℃ |
| Light Duty (LD) | 120% rated current for 60s, 150% rated current for 3s | Humedad relativa: 5% a 95% (non-condensing) |
- Aplicaciones típicas
General industrial machinery: compresores, zapatillas, fans, transportadores, mezcladores, etc..
Metal processing: husillos de máquinas herramienta, winding equipment, wire drawing machines
Lifting & transmitir: grúas, ascensores, automated storage systems
Químico & pharmaceutical: mixing, reaction, and conveying equipment in process industries
Edificio & climatización: air conditioning systems, zapatillas, fan energy-saving control
- Instalación & Directrices de selección
- Requisitos de instalación
Forced-air cooling; ensure sufficient ventilation (≥100mm clearance on all sides)
Mount vertically, avoid direct sunlight and corrosive gas environments
Recommended input reactor and EMC filter for improved stability and EMC performance
- Notas de selección
Select load rating based on actual load type (constant torque / variable torque)
For frequent starting/stopping or heavy starting, select one frame size larger than motor power
For long cable runs, consider voltage drop and dv/dt effects; install output reactor if necessary
- Modelos de reemplazo & Ordering Information
Reemplazo directo: FR-A840-02600-E2-60 (European version, no built-in DC reactor)
Upgraded model: FR-A840-02600-E2-60CRN (with Ethernet interface)
Official order number: 297582 (base model)
The Mitsubishi FR-A840-02600-2-60 is a high-performance, high-reliability 400V-class vector inverter, ideal for driving medium-to-high power motors and providing precise speed and torque control in various industrial automation scenarios. Its CA-type control and conformal coating ensure excellent performance in harsh industrial environments.
Mitsubishi FR Series Inverter Model List & Cross-Brand Comparison
- Classification & Model Meaning of Mitsubishi FR Series
1.1 Series Overview
| Serie | Clase de voltaje | Rango de potencia | Core Position | Aplicaciones típicas |
| FR-A800 | 200V (FR-A820) / 400V (FR-A840) | 0.4kW–500kW | Flagship high-performance vector control | Industria pesada, high-precision torque control, control de movimiento complejo |
| FR-F800 | 200V (FR-F820) / 400V (FR-F840) | 0.4kW–400kW | Energy-saving for fans & zapatillas | climatización, tratamiento de agua, building automation |
| FR-E800/FR-E700 | 200V/400V | 0.1kW–22kW | Compact general-purpose | Maquinaria de embalaje, food & bebida, small production lines |
| FR-D800/FR-D700 | 200V/400V | 0.1kW–75kW | Easy-to-use economy type | Small fans/pumps, transportadores, general machinery |
| FR-CS80 | 200V/400V | 0.4kW–315kW | Heavy-duty special type | Cranes, winders, metallurgical equipment |
| FR-B | 200V/400V | 0.4kW–75kW | Explosion-proof special type | Hazardous areas such as chemical, petroleum, coal mines |
1.2 Full Model Format Explanation
Standard format: FR-XXX-YYYYY-Z-W
| Field | Significado | Ejemplo |
| FR | General prefix for Mitsubishi inverters (Frequency Inverter) | - |
| XXX | código de serie + voltage class | A840 (400V high-performance), F820 (200V fan/pump) |
| YYYYY | Capacity code/power identifier | 02600 (90kW/180A), 15K (15kilovatios) |
| z | Control type | 1 (estándar, 0–10V), 2 (CA type, 0–20mA), E2 (European version, no built-in DC reactor) |
| W. | Special functions | 60 (conformal coating), CRN (Ethernet), R2R (winding dedicated) |
- Complete Model List of Mitsubishi FR Series Inverters
2.1 FR-A840 (400V High-Performance Vector Control) Core Models
| Potencia del motor aplicable | ND Current | SLD Current | Base Model | Special Model |
| 0.75kilovatios | 2.1A | 3.0A | FR-A840-00038-2-60 | FR-A840-00038-E2-60 |
| 1.5kilovatios | 3.7A | 5.3A | FR-A840-00052-2-60 | - |
| 2.2kilovatios | 5.0A | 7.2A | FR-A840-00072-2-60 | - |
| 5.5kilovatios | 11.5A | 16.5A | FR-A840-00170-2-60 | - |
| 11kilovatios | 23A | 33A | FR-A840-00330-2-60 | - |
| 15kilovatios | 30A | 43A | FR-A840-00430-2-60 | - |
| 30kilovatios | 60A | 86A | FR-A840-00860-2-60 | FR-A840-00860-E2-60 |
| 90kilovatios | 180A | 260A | FR-A840-02600-2-60 | FR-A840-02600-E2-60 |
| 132kilovatios | 240A | 345A | FR-A840-03450-2-60 | - |
| 280kilovatios | 500A | 720A | FR-A840-07200-2-60 | - |
2.2 Representative Models of Other Main Series
| Serie | Representative Model | Fuerza | Características clave |
| FR-F840 | FR-F840-5.5K-2 | 5.5kilovatios | Fan/pump dedicated, built-in PID, energy-saving control |
| FR-E740 | FR-E740-1.5K-CHT | 1.5kilovatios | Compacto, built-in EMC filter |
| FR-D740 | FR-D740-7.5K-CHT | 7.5kilovatios | Simple operation, rentable |
| FR-A820 | FR-A820-37K-1 | 37kilovatios | 200V high-performance, suitable for light industry |
- Cross-Brand Inverter Comparison Table
Below shows functional and power matching between Mitsubishi FR series and major brands including Siemens, Schneider, TEJIDO. Precise selection should consider actual load characteristics and control requirements.
| Mitsubishi Model | Siemens Equivalent | Schneider Equivalent | ABB Equivalent | Functional Match |
| FR-A840-02600-2-60 (90kilovatios) | SINAMICS G120C 90kW | ATV630D11N4 | ACS580-01-180A-4 | High-performance vector control, suitable for heavy-duty applications |
| FR-F840-5.5K-2 (5.5kilovatios) | SINAMICS G120X 5.5kW | ATV610U75N4 | ACS580-01-015A-4 | Fan/pump dedicated, energy-saving control |
| FR-E740-1.5K (1.5kilovatios) | SINAMICS V20 1.5kW | ATV320U15N4 | ACS180-04-03A3-4 | Compact general-purpose |
| FR-A820-37K-1 (37kilovatios, 200V) | SINAMICS G120 37kW 200V | ATV630D45N2 | ACS580-04-075A-2 | Medium-power vector control for 200V systems |
| FR-CS840-110K (110kilovatios) | SINAMICS S120 110kW | ATV930D160N4 | ACS880-01-246A-3 | Heavy-duty, four-quadrant operation |
- Selection Key Points & Notas
- Principios de coincidencia de carga
Constant torque loads (transportadores, mezcladores): select FR-A800 series, rated by ND current
Variable torque loads (fans, zapatillas): select FR-F800 series, rated by SLD current
Frequent start/stop or heavy starting: select one size larger than motor power
- Special Environment Adaptation
Harsh industrial environments: prefer models with “60” suffix (conformal coating: FR-A840-XXXXX-2-60)
Explosive/flammable environments: select FR-B series explosion-proof inverters
Ethernet communication: select models with “CRN” suffix
- Instalación & Consejos de mantenimiento
Vertical mounting, ≥100mm clearance on all sides for ventilation
For long cables, recommend output reactor to reduce dv/dt influence
Regular inspection of cooling fans and capacitors for long-term stable operation
Mitsubishi FR series inverters cover a full power range from 0.1kW to 500kW, meeting diverse needs from basic control to high-precision motion control via differentiated series positioning. For cross-brand selection, focus on core parameters including control method, overload capacity, protocolo de comunicacion, and environmental resistance to ensure system compatibility and stability.
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares