Disyuntor de caja moldeada NM1-630S-3300-630A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

Disyuntor de caja moldeada NM1-630S-3300-630A

Segmento de modeloDescripción
NM1Código de serie del producto; CHINT Electric NM1 series molded case circuit breaker, suitable for power distribution protection and motor protection scenarios
630Frame size rated current; the maximum current rating that this series of circuit breakers can carry is 630A
SBreaking capacity class; Type S indicates standard breaking capacity, usually 35kA (refer to the product manual for details), suitable for conventional power distribution environments. Other classes in the same series include H (higher breaking capacity) and L (lower breaking capacity)
3300Pole number + tipo de unidad de disparo + accessory code
First two digits "33": 3-disyuntor de polos, suitable for three-phase three-wire power distribution systems
Last two digits "00": no accessories (como contactos auxiliares, undervoltage release, liberación de derivación, etc.)
630ARated current; the rated operating current set for this circuit breaker is 630A

  • Detalles del producto
  1. Interpretación del modelo
Segmento de modeloDescripción
NM1Código de serie del producto; CHINT Electric NM1 series molded case circuit breaker, suitable for power distribution protection and motor protection scenarios
630Frame size rated current; the maximum current rating that this series of circuit breakers can carry is 630A
SBreaking capacity class; Type S indicates standard breaking capacity, usually 35kA (refer to the product manual for details), suitable for conventional power distribution environments. Other classes in the same series include H (higher breaking capacity) and L (lower breaking capacity)
3300Pole number + tipo de unidad de disparo + accessory code
First two digits “33”: 3-disyuntor de polos, suitable for three-phase three-wire power distribution systems
Last two digits “00”: no accessories (como contactos auxiliares, undervoltage release, liberación de derivación, etc.)
630ARated current; the rated operating current set for this circuit breaker is 630A
  1. Parámetros técnicos básicos
Categoría de parámetroSpecific Index
Tensión de funcionamiento nominal (Ue)Three-phase AC 400V (50Hz), suitable for low-voltage power distribution systems
Corriente nominal (En)630A
Marco actual (Iu)630A
Capacidad de ruptura (uci)Class S: 35el (at AC 400V)
Tipo de unidad de disparoThermal-magnetic trip unit (overload long-time delay protection + short-circuit instantaneous protection)
Overload Protection CharacteristicsLong-time delay inverse-time characteristic; setting current Ir = 1.0In (630A). It can withstand 1.05In for long-term operation and will not trip within 1 hour under 1.3In
Short-Circuit Protection CharacteristicsInstantaneous trip setting current Ii = 10In (6300A); it trips instantaneously when the short-circuit current reaches this value
Clase de protecciónIP20 (enclosure protection, preventing finger access)
Método de montajeFixed type/draw-out type (confirm specific model; fixed type is standard)
Método de cableadoFront-panel wiring (estándar); rear-panel wiring is optional

III. Functional Features

  1. Dual Protection Function: Integrates overload long-time delay protection and short-circuit instantaneous protection, which can effectively cut off overload and short-circuit fault currents to protect power distribution lines and equipment.
  2. Standard Breaking Capacity: The 35kA breaking capacity meets the short-circuit protection requirements of most industrial plants, commercial buildings, and civil power distribution scenarios.
  3. Modular Design: Supports the installation of accessories such as auxiliary contacts, liberaciones de derivación, and undervoltage releases to expand functions like remote control and fault signal feedback.
  4. Easy Operation: Adopts a manual energy storage operating mechanism with clear closing/opening actions, and is equipped with a transparent observation window for intuitive inspection of contact status.
  5. Long Electrical and Mechanical Service Life: Electrical service life ≥ 10,000 veces; mechanical service life ≥ 20,000 veces, suitable for power distribution scenarios with frequent switching.
  6. Ámbito de aplicación
  7. Main Switch of Power Distribution System: Suitable for incoming line and bus section switches in 400V three-phase low-voltage power distribution systems, protecting the secondary side of transformers and outgoing circuits of power distribution cabinets.
  8. Industrial Equipment Protection: Can be used as the power-side protection switch for high-power motors (como los fanáticos, bombas de agua, compressors with power ≤ 315kW).
  9. Building Power Distribution Scenarios: Protection of power distribution trunk lines in shopping malls, edificios de oficinas, factory workshops, etc., suitable for environments with conventional short-circuit current levels.
  10. Not Suitable For: Power distribution systems with high short-circuit current (> 35el), precision equipment circuits requiring selective protection, and DC power distribution scenarios.
  11. Selection Suggestions
  12. Match Load Current: The rated load current should be ≤ 630A. If the load is a motor, the motor starting current must be considered (it is recommended that the instantaneous setting current of the trip unit be ≥ 8 times the rated motor current).
  13. Verify Breaking Capacity: The calculated on-site short-circuit current should be ≤ 35kA. If the short-circuit current exceeds 35kA, upgrade to the NM1-630H type (higher breaking capacity, usually 50kA/65kA).
  14. Accessory Selection:

For remote opening: Install a shunt release (code 3310).

For undervoltage protection: Install an undervoltage release (code 3320).

For fault signal feedback: Install auxiliary contacts (code 3308).

  1. Brand Replacement Reference:
MarcaReplacement ModelDiferencias fundamentales
SchneiderNSX630N 3P 630AHigher breaking capacity (50el) and higher price
siemens3VL630 3P 630ARicher modular accessories, suitable for Siemens power distribution systems
DeliciosoCDM1-630S 3300 630ADomestic brand of the same grade with consistent parameters and high cost performance
  1. Solución de problemas
Fallos comunesPosibles causasSoluciones
Trips immediately after closing1. Short-circuit fault exists in the line1. Troubleshoot the short-circuit point of the line and close after repair
2. Leakage on the load side (not applicable if no leakage accessory is installed)2. Check the insulation condition of the load
3. The instantaneous trip current setting is too small3. Confirm whether the trip unit setting current matches the load
Does not trip during overload1. Thermal trip unit failure1. Replace the thermal trip unit
2. The trip unit setting current is adjusted too high2. Re-adjust the setting current to the rated value
3. Circuit breaker contact adhesion3. Disassemble and inspect the contacts; replace the circuit breaker if necessary
Cannot close1. Undervoltage release is not powered on (if installed)1. Check whether the power supply of the undervoltage release is normal
2. Mechanical mechanism jamming2. Manually reset the mechanical mechanism and clean internal foreign objects
3. Line fault not eliminated3. Troubleshoot and eliminate line faults
Abnormal heating during operation1. Loose wiring terminals1. Tighten the wiring terminals and apply conductive paste
2. Load current exceeds the rated value2. Reduce the load or replace with a larger specification circuit breaker
3. Temperatura ambiente excesivamente alta3. Improve ventilation and heat dissipation conditions

VII. Installation and Maintenance Notes

  1. Antes de la instalación, confirm that the rated voltage and current of the circuit breaker match the on-site power distribution system, and check that the appearance is intact and the mechanism is free of jamming.
  2. Ensure that the terminals are tightened during wiring to avoid heating caused by poor contact. For front-panel wiring, the wire cross-section should match the 630A current (it is recommended to use 240mm² copper core cable).
  3. Regularly (every 6 meses) inspect the contact status of the circuit breaker and the flexibility of the mechanical mechanism, and remove dust inside the enclosure.
  4. After a fault trip, the cause of the fault must be investigated first; do not close forcibly to avoid expanding the fault range.

Parameter Comparison Table of NM1-630S-3300 Series (400A/500A/630A)

Categoría de parámetroModel Specification
Parámetros básicosNM1-630S-3300-400ANM1-630S-3300-500ANM1-630S-3300-630A
Frame Size Rated Current (Iu)630A630A630A
Corriente de funcionamiento nominal (En)400A500A630A
Tensión de funcionamiento nominal (Ue)AC 400V 50HzAC 400V 50HzAC 400V 50Hz
Número de polo3-polo3-polo3-polo
Tipo de unidad de disparoThermal-magnetic (overload long-time delay + short-circuit instantaneous)Thermal-magnetic (overload long-time delay + short-circuit instantaneous)Thermal-magnetic (overload long-time delay + short-circuit instantaneous)
Características de protección
Capacidad de ruptura (uci, AC 400V)35el35el35el
Overload Long-Time Delay Setting Current (Y)400A (1.0En)500A (1.0En)630A (1.0En)
Overload Withstand CharacteristicsWithstand 1.05In for long-term operation; no tripping within 1h under 1.3InWithstand 1.05In for long-term operation; no tripping within 1h under 1.3InWithstand 1.05In for long-term operation; no tripping within 1h under 1.3In
Short-Circuit Instantaneous Setting Current (yo)10In = 4000A10In = 5000A10In = 6300A
Instalación y cableado
Clase de protecciónIP20IP20IP20
Método de montajeFixed type/draw-out type (optional)Fixed type/draw-out type (optional)Fixed type/draw-out type (optional)
Recommended Matching Copper Core Cable Cross-Section185mm²240mm²240mm²/300mm²
Mechanical and Electrical Service Life
Vida útil mecánica≥20,000 times≥20,000 times≥20,000 times
Electrical Service Life≥10,000 times≥10,000 times≥10,000 times
Escenarios de aplicación típicos1. Power-side protection for 185kW three-phase motors1. Power-side protection for 250kW three-phase motors1. Power-side protection for 315kW three-phase motors
2. Power distribution branch switch (load current 350-400A)2. Power distribution trunk branch switch (load current 450-500A)2. Power distribution incoming line/bus section switch
3. Power distribution branch in small and medium-sized plants3. Power distribution branch in shopping malls and office buildings3. Power distribution trunk in large plants and high-rise buildings

Supplementary Selection Tips

  1. All specifications of this series have the same breaking capacity. Select the corresponding specification only according to the rated load current; there is no need to verify the breaking capacity additionally.
  2. If the load is a motor with frequent starting, it is recommended to select a specification with a rated current 1.1-1.2 times that of the motor to avoid overload false tripping.
  3. For the same frame size specification, the rated current can be adjusted by replacing the trip unit without replacing the circuit breaker body, reducing the later transformation cost.