Unidad maestra OMRON GX-ILM08C

Nombre completo: GX-series EtherCAT IO-Link Master Unit (IP67 Field Type) Posicionamiento central: Autobús EtherCAT, 8-channel IO-Link master, M12 A-coding female connector. A prueba de polvo e impermeable, can be mounted directly on equipment frames or production lines without installation inside control cabinets. ✅ Key Specifications Number of ports: 8 IO-Link ports (M12 A-coding female) Interfaz de autobús: EtherCAT (IN/OUT ...

  • Detalles del producto

Nombre completo: GX-series EtherCAT IO-Link Master Unit (IP67 Field Type)

Posicionamiento central: Autobús EtherCAT, 8-channel IO-Link master, M12 A-coding female connector. A prueba de polvo e impermeable, can be mounted directly on equipment frames or production lines without installation inside control cabinets.

✅ Especificaciones clave

Number of ports: 8 IO-Link ports (M12 A-coding female)

Interfaz de autobús: EtherCAT (IN/OUT M12, supports daisy-chain connection)

Versión IO-Link: V1.1.2

Velocidad de baudios: COM1 (4.8k) / COM2 (38.4k) / COM3 (230.4k) autoadaptativo

Power supply per port: CC 24 V, máximo. 200mA per port, with independent short-circuit protection

SIO compatible mode: Switchable to PNP DI / PNP DO

DE: ON ≥15V, OFF ≤5V; multi-stage filter time optional (predeterminado de fábrica: 1EM)

HACER: Salida push-pull, 0.3Un por canal

Power supply range: DC20.4~26.4V (24V ±10%/-15%)

Clase de protección: IP67 (suitable for dusty and humid field environments)

Software de configuración: Estudio Sysmac, CX-ConfiguratorFDT

PLC compatibles: NX/NJ/NY series EtherCAT controllers

✅ Main Features

  1. IP67 field mounting, saves junction boxes, adopts M12 Smartclick quick connectors
  2. 8 independent IO-Link master ports. Each port can connect IO-Link sensors, islas de válvulas, analog modules, RFID and other smart slaves
  3. Flexible port mode switching: IO-Link smart mode / SIO digital DI / SIO digital DO
  4. EtherCAT daisy-chain, simple networking. Diagnostic information (sensor temperature, signal quality, event alarms) can be uploaded to PLC
  5. Supports automatic upload, download and backup of IO-Link device parameters. No manual setting required after sensor replacement

✅ Similar Series & Referencia alternativa

GX-ILM04C: 4-port version (same architecture IP67 EtherCAT IO-Link master)

NX-ILM08C: NX backplane type (cabinet-mounted, non-IP67), no confundas

✅ Escenarios de aplicación típicos

Líneas de montaje, máquinas de embalaje, maquinas herramientas, material handling lines, for mass connection of IO-Link photoelectric sensors, sensores de proximidad, sensores de presión, flow sensors, proportional valves and IO-Link hubs.

✅ Notes

EtherCAT cables shall be CAT5e or higher grade shielded STP cable;

SIO DO is PNP push-pull output, cannot directly drive heavy loads;

All ports share 24V power supply, with independent short-circuit protection for each port.

GX‑ILM08C’s core advantages: IP67 field-side installation, EtherCAT daisy-chain, 8-channel IO‑Link, ports compatible with ordinary DI/DO. It is designed for outside control cabinets, dusty and humid production lines, and differentiated from NX‑ILM08C (IP20 for cabinet installation).

  1. Aplicaciones industriales típicas
  2. Automotive component assembly lines, accesorios de herramientas, estaciones de trabajo robóticas

Connected to IO-Link proximity sensors, sensores fotoeléctricos, cylinder magnetic switches, sensores de presión, proportional valves, fixture in-place sensors.

Ventajas: Modules can be mounted beside tooling without routing cables back to cabinet junction boxes; sensor temperature, signal margin and offset data can be read for predictive maintenance. Parameters can be downloaded automatically during fixture changeover to shorten product change time.

  1. Maquinaria de embalaje (envoltorios de flujo, empacadoras de cajas, paletizadores)

For photoelectric detection, nivel de material, presión, web guiding sensors and IO-Link valve islands. IP67 rating fits oily and humid conditions. Ordinary PNP sensors can be used in SIO mode, friendly for retrofitting projects mixing old and new sensors.

  1. Material handling lines, líneas de clasificación, almacenes automatizados, AGV stations

Detección de posición, code-reading trigger and photoelectric sensors for belt conveyors, roller lines and transfer units. Long-distance segmented EtherCAT daisy-chain wiring. Wire break, short circuit and sensor disconnection alarms are sent to PLC for fast fault location and reduced downtime.

  1. Máquinas herramienta, stamping and injection molding equipment

Peripheral detection of machine tools, cortinas de luz de seguridad, mold confirmation, mold pressure, cooling circuit flow and temperature. Resists cutting fluid and dust. Sensor degradation data can be collected for early warning to avoid defective batches.

  1. Alimento & líneas de producción farmacéutica (wash-down environments)

IP67 protection and M12 quick connectors for wash applications. Connected to sanitary IO-Link flow, temperature and level sensors. Supports sensor ID verification to prevent wrong installation.

  1. batería de litio & equipos fotovoltaicos (inyección de liquido, lamination, clasificación)

Centralized access of large numbers of small-point smart sensors. Sensor parameters can be backed up and restored with one click; no on-site commissioning required when replacing sensors in batches. Status data can be uploaded to SCADA for OEE analysis.

  1. Functional Use Cases

Sensor condition visualization & mantenimiento predictivo: Monitor photoelectric received light intensity, sensor temperature, vibration and pressure, set threshold alarms before total failure.

Production line retrofitting: Expand I/O points locally on site without adding new control cabinets. Legacy sensors use SIO DI/DO while new smart sensors run IO-Link.

Flexible multi-product production lines: Automatic parameter download for product changeover, automatic sensor identification and anti-mismatch function.

Arquitectura de E/S distribuidas: Multiple scattered acquisition points on one line connected via EtherCAT chain, reducing heavy multi-core cables.

III. Escenarios inadecuados

Cabinet internal installation with compact backplane requirement: choose NX‑ILM08C

High corrosion or continuous immersion conditions (only IP67, not for long-term submersion)

High-current loads per channel (máximo. 0.3A for DO ports)

  1. Matching Configuration

Controlador: NX/NJ/NY series EtherCAT PLC; Software: Estudio Sysmac; Networking: Multiple GX modules daisy-chained with STP shielded EtherCAT cables.

OMRON GX-series IO-Link Master Units

✅ GX series only has one official IO-Link master model: GX-ILM08C. GX-ILM04C does not exist; the 4-port field IO-Link master does not belong to the GX series.

ModeloPuertosProtecciónAutobúsInterfazDescripción
GX-ILM08C8 Enlace IOIP67EtherCATM12 A-coding female (Enlace IO); M12 D-coding (EtherCAT IN/OUT)Field distributed I/O, M12 quick connect, port switchable SIO DI/DO, compatible with NX/NJ/NY EtherCAT controllers

Confusable IO-Link Masters from Related Families (Not GX series)

ModeloSeriePuertosProtecciónAutobúsConstrucción
NX-ILM400NX4IP20EtherCATCabinet backplane mounting, terminal de tornillo, for indoor cabinet use
NXR-ILM08C-ECTNXR8IP67EtherCATRugged remote terminal, similar form factor to GX
NXR-ILM08C-EITNXR8IP67Ethernet/IPEtherNet/IP version, not EtherCAT

Additional GX-series EtherCAT Remote I/O Modules (Not IO-Link Masters)

GX is Omron’s large IP67 EtherCAT remote I/O family. Besides IO-Link master, it includes digital and analog modules:

GX-ID16□2 / OD16□2 / MD16□2: 3-tier terminal digital I/O

GX-□D16□1 / OC1601: 2-tier terminal digital I/O

GX-□D16□8 / □D32□8: e-CON connector digital I/O

GX-AD0471 / DA0271: Entrada analógica / salida analógica

GX-EC0211 / EC0241: EtherCAT junction / branch units

GX-JC03 / JC06: Extension connectors