This is the Phoenix Contact QUINT series diode redundancy module (QUINT-DIODO/12-24DC/2X20/1X40).
Está diseñado para redundancia paralela de alimentación dual de 12 a 24 V CC o superposición de alimentación., admite modo de redundancia de 2 × 20 A o modo de expansión de capacidad de 1 × 40 A. Adopta montaje en carril DIN con grado de protección IP20., Adecuado para escenarios de suministro de energía de alta disponibilidad, como automatización industrial y control de procesos..
- Definición del segmento del modelo
| Segmento | Significado |
| QUINT | Phoenix Contact high-performance power supply series, representing high quality and high reliability |
| DIODE | Diode-type redundancy module; realizes electrical isolation between power supplies via diodes |
| 12-24corriente continua | Applicable DC input voltage range: 12–24V DC (amplia gama: 10–30V DC) |
| 2X20 | Redundancy mode: 2-channel input, rated current per channel 20A (-25°C ~ 60°C) |
| 1X40 | Capacity expansion mode: 1-salida de canal, total rated current 40A (-25°C ~ 60°C) |
| 2320157 | Phoenix Contact global unique part number for ordering and identification |
- Parámetros de especificación principales
| Categoría de parámetro | Especificaciones detalladas |
| Funciones básicas | Redundancy module / diode decoupling / 2-input 1-output / IP20 / Class III protection / UL 508 certificado |
| Parámetros eléctricos | • Input Voltage: 10–30V DC (rated 12–24V DC) |
| • Rated Current: 2×20A (redundancia) / 1×40A (capacity expansion) | |
| • Max Current: 2×30A (-25°C~40°C) / 1×60A (-25°C~40°C) | |
| • Power Loss: ≤10W @ 20A output | |
| • Efficiency: >97% | |
| Parámetros mecánicos | • Dimensiones: 50(W.)×130(h)×125(D) milímetros |
| • Montaje: NS 35 Carril DIN (EN 60715) | |
| • Peso: 0.75kilos | |
| Parámetros ambientales | • Operating Temperature: -40°C ~ 70°C (2.5% derating per K above 60°C) |
| • Storage Temperature: -40°C ~ 85°C | |
| • Humidity: ≤95% RH @ 25°C, sin condensación | |
| • Protection Class: IP20 | |
| • MTBF: 40,000,000 horas (CEI 61709) | |
| Connection Parameters | • Input Terminals: M3 screw / 0.2–6mm² (sólido) / 0.2–4mm² (varado) / stripping length 7mm |
| • Output Terminals: M4 screw / 0.5–16mm² (solid/stranded) / stripping length 10mm | |
| • Wire Gauge: Input AWG 12–10 / Output AWG 10–6 | |
| Certificaciones de seguridad | UL/C-UL Listed UL 508, UL 60950-1, ANSI/ISA-12.12.01 (Class I Div.2), ATEX, IECEx |
- Lista de accesorios & Package Contents
Paquete estándar: 1 pcs QUINT-DIODE/12-24DC/2X20/1X40 Module (2320157)
Supplied Documents: Installation manual, product certificate, PDF download link for technical datasheet
Accesorios opcionales:
DIN rail mounting adapter (p.ej. UTA 107/30)
Terminal protective cover
Marker strip / marking system
- Competidor & Lista de reemplazo entre marcas
| Marca | Modelo | Parámetros principales | Replace Compatibility |
| Phoenix Contact Upgrade Version | 2907719 (QUINT4-DIODE/12-24DC/2X20/1X40) | Mismas especificaciones, new generation QUINT4 series with optimized performance | Totalmente compatible, reemplazo directo |
| Electricidad Schneider | ABL8RPS24040 | 24VCC / 2×20A / 1×40A / Diode redundancy | Funcionalmente equivalente, slight difference in mounting dimensions |
| siemens | SITOP Redundancy Module 6EP1961-3BA21 | 24VCC / 2×20A / Diode redundancy | Funcionalmente equivalente, confirm installation space |
| Weidmüller | DRM 20-24DC/2×20/1×40 | 24VCC / 2×20A / 1×40A / Diode redundancy | Direct competitor with similar performance |
| TEJIDO | CM-MRD 24DC 40 | 24VCC / 40A / Diode redundancy module | Similar function, different input channel quantity possible |
- Puntos clave de selección & Soluciones alternativas
5.1 Criterios de selección básicos
✅ Voltage Matching: Confirm system voltage 12–24VDC, fluctuation range within 10–30VDC
✅ Current Matching:
Redundancy Mode: Single power supply rated current ≤20A, dual power parallel connection
Capacity Expansion Mode: Total load current ≤40A, dual power parallel for power upgrade
✅ Installation Space: Reserve 50mm width, 5mm gap on both sides, 15mm top clearance and 20mm bottom clearance for heat dissipation
✅ Environmental Conditions: Operating temperature ≤60°C (2.5% derating per K over temperature), humidity ≤95% non-condensing
5.2 Alternative Solution Decision Tree
| Escenario de aplicación | Modelo recomendado | Razón |
| Standard Redundancy Requirement | 2320157 (Original Version) | Mature, stable and cost-effective |
| Latest Technology Requirement | 2907719 (QUINT4 Series) | Nueva generación, optimized performance and longer service life |
| Mayor requisito actual | QUINT-DIODE/48DC/2X20/1X40 (2320160) | 48VDC system with same current rating |
| Lower Current Requirement | TRIO-DIODE/12-24DC/2X10/1X20 | 10A/20A rating with lower cost |
| Active Redundancy Requirement | QUINT S-ORING (2907752) | Active switching, lower voltage drop and higher efficiency |
- Mnemónico de selección (Selección & Solicitud)
QUINT Diode Redundancy Module Selection Mnemonic
12–24 DC for use, two inputs one output keep in view
20A stable for redundancy, 40A flexible for capacity boost
Derate above sixty centigrade, 2.5% per Kelvin degrade
Reserve mounting gap well, ensure heat dissipation as well
Old version 2320157, new version 2907719
Choose S-ORING for active redundancy, higher efficiency and more steady
- Key Application Scenarios
- Automatización Industrial: Dual power redundancy for PLC control cabinets to ensure uninterrupted control system operation
- Control de procesos: Power supply for critical process instruments in chemical, pharmaceutical and other industries to avoid production shutdown caused by power failure
- Centro de datos: Redundant power backup for servers and network equipment to guarantee data security
- Rail Transit: Dual power guarantee for on-board equipment and signal systems, adaptarse a entornos hostiles
- Energía Renovable: Redundant power supply for photovoltaic and wind power control systems to improve system availability
Complete Model List of Phoenix Contact Diode Redundancy Modules
Descripción general: Classified into 6 major series: QUINT4 / QUINT / TRIO2 / TRIO / UNO / STEP3, covering 5–48VDC voltage and 5–40A current specifications, including standard type / monitored type / coated type versions to meet different power and reliability requirements.
- QUINT4 Series (New Generation High Performance)
| Número de pieza. | Modelo | Rango de voltaje | Clasificación actual | Características principales |
| 2907719 | QUINT4-DIODE/12-24DC/2X20/1X40 | 12–24VDC (10–30VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | Latest QUINT4 platform, alta confiabilidad, MTBF>40 million hours |
| 2907720 | QUINT4-DIODE/48DC/2X20/1X40 | 48VCC (30–56VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | Compatible with 48V system, fully interchangeable with classic QUINT |
| 2907721 | QUINT4-DIODE/12-24DC/2X10/1X20 | 12–24VDC (10–30VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | Versión de baja corriente, space-saving and cost-effective |
| 2907722 | QUINT4-DIODE/48DC/2X10/1X20 | 48VCC (30–56VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | 48V low current application, matches TRIO power supply |
- QUINT Series (Classic High Performance)
| Número de pieza. | Modelo | Rango de voltaje | Clasificación actual | Características principales |
| 2320157 | QUINT-DIODO/12-24DC/2X20/1X40 | 12–24VDC (10–30VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | Most commonly used model, matched with QUINT 24V power supply |
| 2320160 | QUINT-DIODE/48DC/2X20/1X40 | 48VCC (30–56VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | Matched with QUINT 48V power supply, estándar industrial |
| 2866585 | QUINT-DIODE/48DC/40 | 48VCC (30–56VDC) | 1×40A | With protective coating, adecuado para entornos hostiles |
| 2938963 | QUINT-DIODO/40 | 12–24VDC (10–30VDC) | 1×40A | Simplified version, single-channel 40A output |
| 2866584 | QUINT-DIODE/12-24DC/40 | 12–24VDC (10–30VDC) | 1×40A | With protective coating, single-channel output |
- TRIO2 Series (Cost-Efficient High-Efficiency)
| Número de pieza. | Modelo | Rango de voltaje | Clasificación actual | Características principales |
| 2907379 | TRIO2-DIODE/12-24DC/2X20/1X40 | 12–24VDC (10–30VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | Rendimiento de alto costo, matched with TRIO2 power supply |
| 2907380 | TRIO2-DIODE/12-24DC/2X10/1X20 | 12–24VDC (10–30VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | Low current version for light load |
| 2907381 | TRIO2-DIODE/48DC/2X10/1X20 | 48VCC (30–56VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | 48sistema V, matched with TRIO2 48V power supply |
| 2907382 | TRIO2-DIODE/48DC/2X20/1X40 | 48VCC (30–56VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | 48V high current, economic alternative solution |
- TRIO Series (Basic Economy Type)
| Número de pieza. | Modelo | Rango de voltaje | Clasificación actual | Características principales |
| 2866514 | TRIO-DIODE/12-24DC/2X10/1X20 | 12–24VDC (10–30VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | With function monitoring, first choice for basic applications |
| 2866527 | TRIO-DIODE/48DC/2X10/1X20 | 48VCC (30–56VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | 48V with monitoring, matched with TRIO 48V power supply |
| 2866515 | TRIO-DIODE/12-24DC/2X20/1X40 | 12–24VDC (10–30VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | High current with monitoring, rentable |
| 2866528 | TRIO-DIODE/48DC/2X20/1X40 | 48VCC (30–56VDC) | 2×20A Redundancy / 1×40A Capacity Expansion | 48V high current with monitoring, general industrial use |
- UNO Series (Ultra-Compact Miniature)
| Número de pieza. | Modelo | Rango de voltaje | Clasificación actual | Características principales |
| 2905489 | UNO-DIODE/5-24DC/2X10/1X20 | 5–24VDC (4.5–28VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | Diseño ultracompacto, matched with UNO miniature power supply |
| 2905490 | UNO-DIODE/5-24DC/2X5/1X10 | 5–24VDC (4.5–28VDC) | 2×5A Redundancy / 1×10A Capacity Expansion | Clasificación mínima actual, suitable for embedded systems |
- STEP3 Series (Entry-Level for Control Cabinet)
| Número de pieza. | Modelo | Rango de voltaje | Clasificación actual | Características principales |
| 1283937 | STEP3-DIODE/5-24DC/2X5/1X10/PT | 5–24VDC (4.5–28VDC) | 2×5A Redundancy / 1×10A Capacity Expansion | Entry-level price, matched with STEP3 basic power supply |
| 1283938 | STEP3-DIODE/12-24DC/2X10/1X20 | 12–24VDC (10–30VDC) | 2×10A Redundancy / 1×20A Capacity Expansion | Basic high current type for simple redundancy demand |
- Mnemónico de selección & Key Differentiation
7.1 Series Positioning Mnemonic
QUINT4: New flagship, alta confiabilidad, larga vida útil
QUINT: Classic model, stable performance, wide application
TRIO2: New economy, rentable, matches new power supplies
TRIO: Modelo básico, with monitoring, bajo costo
UNO: Ultracompacto, miniaturized, embedded use
STEP3: Nivel de entrada, precio bajo, basic application
7.2 Key Parameter Differentiation
| Parámetro | Puntos de selección |
| Voltaje | 12–24VDC(10–30VDC): Most common in industry |
| 48VCC(30–56VDC): High power / remote power supply | |
| 5–24VDC(4.5–28VDC): Bajo voltaje / hybrid system | |
| Actual | 2×5A/1×10A: Carga ligera |
| 2×10A/1×20A: Carga media | |
| 2×20A/1×40A: Heavy load / power superposition | |
| Función | With monitoring: Fault alarm for easy maintenance |
| With coating: Adapt to humid / dusty environment | |
| Tipo estándar: General scenarios with high cost performance |
- Application Scenario Matching Guide
| Escenario de aplicación | Serie recomendada | Modelo típico |
| Industrial Automation PLC Cabinet | QUINT / QUINT4 | 2320157(2907719), 2320160(2907720) |
| Process Control Critical Equipment | QUINT4 (Coated Version) | 2907719, 2866585 |
| Small Control Cabinet / Embedded System | UNO / STEP3 | 2905489, 1283937 |
| Cost-Effective Projects | TRIO2 / TRIO | 2907379, 2866514 |
| 48Sistema V (Telecom / Centro de datos) | QUINT4 / QUINT | 2907720, 2320160 |
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares



















NH42-63-318x560.png)