SMC Filter Regulator AW30-03E1-W-B

SMC AW series modular filter regulator, 3/8 inch port size, 5μm filtration precision, equipped with reverse flow function and white built-in pressure gauge. It is used for pre-treatment of compressed air in pneumatic systems, supplying clean and stable compressed air to solenoid valves, cylinders and other pneumatic components. Model Segment Definition Model Segment Meaning Description ...

  • Detalles del producto

SMC AW series modular filter regulator, 3/8 inch port size, 5μm filtration precision, equipped with reverse flow function and white built-in pressure gauge. It is used for pre-treatment of compressed air in pneumatic systems, supplying clean and stable compressed air to solenoid valves, cylinders and other pneumatic components.

  1. Definición del segmento del modelo
Segmento de modeloSignificadoDescripción
AWSerie de productosIdentification of SMC modular filter regulator series
30Tamaño del marcoTamaño 30, flow rate approx. 1400 l/min (ANR)
3Port Specification3/8 pulgada (Rc thread)
E1Special FunctionE = With reverse flow function; 1 = Standard type
W.Pressure Gauge TypeWhite built-in pressure gauge (with limit indicator)
BModo de drenajeManual drain (B = Standard type)
SMCLogotipo de la marcaSMC Corporation, Japón
  1. Core Specification Parameter Table
Categoría de parámetroÍndice técnicoObservaciones
Parámetros básicos
Working FluidCompressed AirExcluding corrosive gas and chemically active gas
máx.. Operating Pressure1.0 MPa (10 bar)Exceeding may damage internal components
Pressure Setting Range0.02~0.8 MPaStandard pressure regulation range
Filtration Precision5μmEffectively filters solid particles and oil mist
Tamaño del puertoRc3/8 (3/8 inch taper pipe thread)Inlet and outlet identical
Flow Characteristic1400 l/min (ANR)At pressure drop of 0.02 MPa
Temperatura ambiente-5℃ ~ +60℃Under non-freezing condition
Fluid Temperature-5℃ ~ +60℃
PesoAprox.. 0.36 kilosIncluding pressure gauge
Características estructurales
Pressure Regulation MethodKnob type (with locking function)Prevent misoperation
Modo de drenajeManual drainRotate bottom knob clockwise for draining
Pressure GaugeWhite built-in, 0~1.0 MPaWith limit indicator for easy pressure setting management
Bowl MaterialPolycarbonate (ordenador personal)Transparent with metal protective cover
Filter ElementPolyester FiberReplaceable, service life approx. 1000 horas
Reverse Flow FunctionConfiguración estándarAllows reverse airflow for special circuit application
Características de instalación
Tipo de montajeModular mounting / Independent mountingCan be combined with other SMC air preparation components
Mounting DirectionInstalación vertical (bowl facing downward)Ensure good drainage performance
Flow DirectionLeft inlet, Right outletStandard flow direction
  1. Lista de accesorios & Installation Guidelines

3.1 Standard Package Contents

AW30-03E1-W-B Filter Regulator main unit

White built-in pressure gauge (pre-installed)

Metal bowl protective cover (pre-installed)

Filter element (pre-installed)

Soporte de montaje (for modular assembly)

Product manual (including maintenance instructions)

3.2 Accesorios opcionales

Número de pieza.NombreFunción
AW30-03-DFilter Element (Spare Part)5μm filtration precision, periodic replacement
KQ2H03-00Push-in FittingSimplify tube connection
AME30-03LubricatorCombine with filter to form FRL unit
AC30-03Air FilterFront coarse filtration to extend main filter service life
AW30-X2622SUS316 Stainless Steel VersionSuitable for corrosive environments

3.3 Puntos clave de instalación

Mounting Direction: Must be installed vertically with the bowl facing downward to ensure smooth discharge of condensed water.

Método de conexión: Rc3/8 threaded connection; sealing tape or sealant is recommended, tightening torque 15~20 Nm.

Modular Combination: Can be assembled with SMC series lubricators and regulators via modular clips to save installation space.

Maintenance Clearance: Reserve ≥50mm space at the bottom for manual draining and filter replacement.

Air Pre-filtration: It is recommended to install a main line filter at the upstream with filtration precision ≤40μm to protect this component.

  1. Funciones & Escenarios de aplicación

Funciones principales

  1. Gas-Liquid Separation: Effectively separate moisture and impurities from compressed air via centrifugal force and filter element.
  2. Pressure Regulation: Precisely adjust output pressure to keep pneumatic system stable.
  3. Pressure Indication: White built-in pressure gauge with limit indicator for intuitive pressure monitoring and safety range setting.
  4. Reverse Flow Protection: Built-in reverse flow valve allows reverse airflow and prevents circuit pressure impact.
  5. Manual Draining: Bottom knob draining design, fácil operación, suitable for low-humidity environments.

Escenarios de aplicación típicos

Campo de aplicaciónEquipo aplicableFunción principal
Automated Production LineAssembly line, Conveyor systemSupply clean and stable air to solenoid valves and cylinders
Machine Tool IndustryMachining center, CNC latheProtect pneumatic fixtures and tool changing systems
Packaging EquipmentPackaging machine, PalletizerStabilize speed and force of pneumatic actuators
Fabricación de productos electrónicosEquipos semiconductores, Máquina de colocación SMTPrevent fine particles from contaminating precision components
Alimento & BeverageFilling equipment, Packaging lineMeet food-grade pneumatic system requirements
Fabricación de automóvilesWelding robot, Coating lineProtect pneumatic tools and precision inspection equipment
  1. Cross-Brand Alternative Comparison Table
MarcaModeloParámetros claveCompatibilidadGama de precios
SMC (Original)AW30-03E1-W-B3/8″, 5μm, 0.02~0.8MPa, Reverse flow / White gauge100%600–800 CNY
FIESTALFR-3/8-D-MINI3/8″, 5μm, 0.05~0.8MPa, Manual drainAlto500–700 CNY
SchneiderV50A313A-033/8″, 5μm, 0.05~0.8MPa, With pressure gaugeMedio400–600 CNY
ÁRTICOGFR300-033/8″, 5μm, 0.05~0.8MPa, Manual drainMedio200–300 CNY
NORGRENB72G-3GK-AD3-RMN3/8″, 5μm, 0.07~0.7MPa, With pressure gaugeAlto700–900 CNY
  1. Directrices de selección & Soluciones alternativas

Selection Mnemonic

Port Matching → Flow Demand → Filtration Precision → Pressure Range → Drainage Mode → Special Function

Selection Decision Guide

  1. Tamaño del puerto: Select 1/4″(02), 3/8″(03) or 1/2″(04) according to pipeline; this model is 3/8″.
  2. Flow Demand: Tamaño 30 for medium flow (1400 l/min); choose Size 20 for low flow, Tamaño 40/60 for high flow.
  3. Filtration Precision: Standard 5μm for most industrial scenarios; precision equipment optional 2μm (suffix with “GRAMO”).
  4. Rango de presión: 0.02~0.8MPa for general use; select 1.6MPa version for high-pressure systems.
  5. Modo de drenaje: Manual drain (B) for low humidity; automatic drain (suffix with “PD”) for high humidity.
  6. Special Function: Choose type “mi” for reverse flow; “BGfor oil mist separation; “X2622for stainless steel version.

Alternativas recomendadas

  1. Budget Limited: Adopt AIRTAC GFR300-03 or domestic alternatives to meet basic functions with cost performance.
  2. Integración del sistema: FESTO LFR series for seamless compatibility with FESTO pneumatic components; NORGREN B72G series for high-end applications.
  3. Function Upgrade: Upgrade to AW30-03BD-M5 (auto drain + pressure gauge port) for unattended operation.
  4. Ambiente áspero: Select AW30-03E1-W-B-X2622 (SUS316 material) for corrosive conditions.
  5. Air Freight Compliance & Proceso de dar un título

Certificación CE: Compliant with EN ISO 4414, ISO 8573-1.

Air Freight Assessment: No built-in lithium battery / supercapacitor; classified as ordinary industrial pneumatic part, no special air freight restrictions.

Packaging Requirement: Anti-static packaging; transport temperature -40℃~+85℃, avoid heavy impact.

Material Compliance: Polycarbonate bowl complies with RoHS standard, applicable to food, electronics and other sensitive industries.

  1. Troubleshooting Quick Reference
Fenómeno de fallaPossible CauseSolución
Unstable Output PressureClogged filter element, fatigue pressure spring, air supply fluctuationReplace filter element, check air source, recalibrate pressure
Pressure Not AdjustableRegulating knob locked, diaphragm damaged, valve core stuckUnlock knob, replace diaphragm, clean valve core
No Pressure Gauge ReadingBroken pressure gauge, blocked pipeline, no air supplyReplace pressure gauge, clear pipeline, check air source
Difficult DrainingTilted bowl, blocked drain outlet, excessive condensed waterAdjust mounting angle, clean drain port, increase draining frequency
Air LeakageAging seals, loose thread connection, damaged diaphragmReplace seals, fasten thread, replace diaphragm
Reverse Flow FailureDamaged reverse valve, atasco de materia extrañaDisassemble for cleaning or replace reverse flow assembly
  1. AW30 Series Full Model & Order Number List
Número de pedido.ModeloPort SpecFiltration PrecisionSpecial FunctionModo de drenajePressure Gauge Type
AW30-03E1-W-BAW30-03E1-W-BRc3/85μmReverse FlowManualWhite Built-in
AW30-03-BAW30-03-BRc3/85μmNo Reverse FlowManualStandard Built-in
AW30-03E-BAW30-03E-BRc3/85μmReverse FlowManualStandard Built-in
AW30-03BG-BAW30-03BG-BRc3/85μmReverse Flow + Oil Mist SeparationManualStandard Built-in
AW30-03BD-BAW30-03BD-BRc3/85μmNo Reverse FlowAutomáticoStandard Built-in
AW30-03ED-BAW30-03ED-BRc3/85μmReverse FlowAutomáticoStandard Built-in
AW30-03E1-W-DAW30-03E1-W-DRc3/85μmReverse FlowAutomáticoWhite Built-in
AW30-03G-BAW30-03G-BRc3/82μmNo Reverse FlowManualStandard Built-in
AW30-03EG-BAW30-03EG-BRc3/82μmReverse FlowManualStandard Built-in
AW30-03-X2622AW30-03-X2622Rc3/85μmNo Reverse FlowManualStandard Built-in
  1. Ciclo de mantenimiento & Recomendaciones de mantenimiento
  2. Filter Element Replacement: Replace every 1000 hours or 3 months under normal working conditions; acortar a 1 month in harsh environments.
  3. Bowl Cleaning: Inspect monthly, remove internal dirt and keep transparent visibility.
  4. Seal Inspection: Check O-rings, diaphragms and other seals every 6 meses; replace in time if aging.
  5. Pressure Calibration: Calibrate output pressure quarterly to meet system requirements.
  6. Draining Operation: Perform manual draining daily after work to prevent condensed water accumulation affecting filtering performance.

Anterior: