Neles ND9106HNT/K05 REV 2.0 Positionneur de vanne intelligent
Marque: Neles (formerly Metso, now Valmet), ND9000 series, single-acting HART smart valve controller. TOUR 2.0 denotes the hardware and firmware revision; ND9106HNT/K05 is the complete order part number.
- Explication du code modèle
ND9106: ND9100 series, designed for single-acting actuators (spring return cylinder), compatible with rotary and linear stroke valves
H: Protocole HART (HART7), 4–20mA loop-powered
N: Basic Hall-effect valve position feedback
T: Flameproof housing Ex d IIC T6 (distinguished from HE1 intrinsically safe version)
/K05: K05 mounting accessory kit, including valve mounting bracket and feedback linkage assembly
TOUR 2.0: Mainboard hardware revision, underlying firmware V2.0. Older REV1.x versions differ in diagnostic algorithms
Distinction: ND9206 is the double-acting version; ND9103 is the basic short-stroke model; ND9106HNT is the single-acting flameproof type.
- Spécifications techniques de base
| Article | Spécification |
| Signal d'entrée | 4–20mA DC, HART7, two-wire loop powered |
| Type d'actionneur | Single-acting spring return; rotary stroke 0~95°, linear stroke 3~120mm |
| Air Supply Pressure | 1.4 ~ 8 bar (0.14~0.8 MPa) instrument air |
| Positioning Accuracy | ±0.2%FS, low hysteresis |
| Protection contre les explosions | ATEX / IECEx Ex d IIC T6, flameproof |
| Classe de protection | IP66 / NEMA4X |
| Température de fonctionnement | -40℃ ~ +85℃ |
| Valve Position Detection | Non-contact Hall sensor, pas d'usure mécanique |
| SIL Certification | SIL2 (full loop assessment required) |
| Air Connection | G1/4; Electrical port M20×1.5 |
| Static Air Consumption | Extremely low, steady state <0.05 NL/min |
| Poids | Environ. 2.7 kilos |
- Fonctions principales
- One-touch auto-calibration: Automatically identifies valve stroke and friction, supports fast on-site auto-tuning; remote configuration via HART communicator or FieldCare
- Valve diagnostic functions: Valve stroke curve, friction diagnosis, seat differential pressure and temperature monitoring, journalisation des événements, enables predictive maintenance; EDDL/DTM compatible
- Piezoelectric pilot valve: Fast dynamic response and low static air consumption to save instrument air over long-term operation
- Local LCD with pushbuttons: On-site viewing of valve position and alarms, configuration of direct/reverse action and flow characteristics (linéaire / equal percentage / quick open); local access lock available
- Configurable fail position: Valve can be set to hold, fully open or fully closed upon loss of air or power (dependent on single-acting spring return design)
- Scénarios d'application typiques
Flameproof hazardous areas in petrochemical, refining, power plant and coal chemical industries. Suitable for spring return single-acting control valves, vannes papillon et vannes à bille; applied for control loop operation plus on-line valve diagnostics.
- Installation & Directives de mise en service
- Installation: K05 kit includes mounting bracket, installation complies with VDI/VDE3845. Minimize clearance of feedback linkage to avoid backlash error
- Alimentation en air: 5μm filtration, sec, oil-free and water-free instrument air
- Câblage: Flameproof construction; cable entry sealing must comply with flameproof standards; intrinsically safe safety barrier is not required
- Calibration procedure: Supply air → connect 4-20mA signal → trigger Auto Tune locally. After tuning completion, verify 4mA/20mA end points and hysteresis
- Communication: Match HART loop load; read valve diagnostic data via FieldCare software
- Common Troubleshooting Checklist
- Valve oscillation: Excessive PID gain or high actuator friction. Reduce positioner gain and appropriately increase dead band
- Valve position fails to follow setpoint: Insufficient air supply, blocked piezo pilot valve or loose feedback linkage
- Unstable HART communication: Mismatched loop load or incorrect cable shielding earthing
- Calibration failure: Stroke exceeds positioner range, jammed feedback mechanism or fluctuating air supply
- REV version differences: REV2.0 fixes false diagnostic alarms present in early REV1.x versions; REV1 firmware cannot be directly flashed onto REV2 hardware
- Comparaison des séries & Sélection alternative
| Modèle | Type d'actionneur | Protection contre les explosions | Remarques |
| ND9106HNT/K05 | Simple effet | Flameproof Ex d | Current model for spring return valves |
| ND9106HN1/K05 | Simple effet | Intrinsically safe Ex ia | Zone 0 IS, safety barrier required |
| ND9206HE8 | À double effet | Antidéflagrant | No spring return cylinder |
| ND9103HNT | Simple effet | Antidéflagrant | Basic version with reduced diagnostic functions |