ABB 3BSE008508R1 DI810 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

ABB 3BSE008508R1 DI810 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

ABB 3BSE008508R1 DI810

ABB 3BSE008508R1 DI810 Digital Input Module (S800 I/O Series) Part of Model Description 3BSE Product prefix for ABB S800 I/O system modules 8508 Product code for DI810 digital input module R1 Hardware revision number (Revision 1) Core Specifications Parameter Category Details Product Name ABB DI810 Digital Input Module System ABB S800 I/O Distributed Process I/O ...

  • Détails du produit

ABB 3BSE008508R1 DI810

Digital Input Module (S800 I/O Series)

Part of ModelDescription
3BSEProduct prefix for ABB S800 I/O system modules
8508Product code for DI810 digital input module
R1Hardware revision number (Revision 1)
  1. Spécifications de base
Catégorie de paramètreDétails
Product NameABB DI810 Digital Input Module
SystemABB S800 I/O Distributed Process I/O System
Input Channels16 digital input channels, divided into two groups of 8 channels each
Tension d'entrée24À DC (wide range: 18V–30V DC)
Input Current6mA per channel, maximum. 150mA total
IsolationGroup isolation (two groups × 8 channels), isolation voltage 500V AC
Temps de réponseStandard mode: ≤1ms; High-speed mode: ≤0.1ms
DiagnosticsChannel status indication, power supply monitoring, wire break detection
Termination UnitTo be used with TU810/TU812/TU814/TU818/TU830 etc.
Indice de protectionIP20 (for indoor cabinet mounting)
Alimentation24À DC, power consumption approx. 2W
Dimensions102mm × 119mm × 45mm (W × H × D)
PoidsEnviron. 0.2kilos (exact 0.24kg)
Température de fonctionnement-20°C à +60°C
Température de stockage-40°C to +85°C
Humidité5%–95% RH (non-condensing)
MontageStandard DIN rail mounting, compatible with S800 I/O system racks
  1. Recommended Operating Environment
  2. Industrial Applications: Process automation control systems, petrochemical, power and energy, metallurgy and mining, paper and printing, industries agroalimentaires
  3. Network Environment: Supports communication with ABB AC 800M controllers, Freelance controllers, and other brand PLCs
  4. Mounting Location: Installed in control cabinets, close to sensors and actuators to reduce wiring costs
  5. Signal Types: Suitable for dry contacts, wet contacts, NO/NC switch signals, and digital output signals from sensors
  6. Cross-Brand Model Comparison & Alternatives
MarqueModèleProduct NameParamètres de baseDifferences from DI810
Siemens6ES7 131-4BD02-0AB0ET 200S Digital Input Module16 channels, 24À DC, group isolationSystem compatibility (PROFIBUS-DP), differences in diagnostic functions
Rockwell1734-IB8POINT I/O 8-Ch Digital Input Module8 channels, 24À DC, individual isolationHalf the number of channels; expansion module required
SchneiderBMXDDI1602Modicon M340 Digital Input Module16 channels, 24À DC, group isolationCommunication protocol (Modbus-TCP), different module dimensions
MitsubishiQX40Q-Series Digital Input Module16 channels, 24À DC, no group isolationDifferent isolation design, different system architecture
OmronCJ1W-ID211CJ-Series Digital Input Module16 channels, 24À DC, group isolationCommunication interface (AppareilNet), differences in diagnostic capabilities
  1. Official Ordering Information
Order DetailsDescription
Official Order Number3BSE008508R1
Packing ListSingle module including installation manual and product certification documents
Garantie12 mois (ABB original factory)
Compatible ControllersABB AC 800M, Freelance, S900, etc..
Modèle de remplacement3BSE008508R0001 (latest version)
  1. Complete Model List for DI810 Series
ModèleDescription
3BSE008508R1Standard version, 16-channel 24V DC digital input, group isolation
3BSE008508R0001Latest hardware revision with improved diagnostics
3BSE008508R2Enhanced version supporting high-speed response (≤0.1ms)
3BSE008508R3Wide-temperature version, operating range -40°C to +70°C
  1. Engineering Implementation Notes
  2. Notes d'installation

Module to be mounted on DIN rail and used with termination units (par ex., TU810)

Maintain at least 5mm clearance between modules for heat dissipation; avoid high-temperature environments

Route input signal cables separately from power cables to reduce electromagnetic interference

  1. Wiring Standards

Each group of 8 channels shares a common terminal (COM); observe group assignments during wiring

Shielded twisted-pair cable recommended for input signals, with shield grounded at one end

Wire break detection must be enabled in system configuration for monitoring critical signals

  1. System Configuration

Configure module parameters in ABB Control Builder software

Adjustable settings: channel response time, filter time, alarm thresholds, etc..

Supports online diagnostics and hot-swapping (system-dependent)

  1. Conseils d'entretien

Regularly check module status LEDs (pouvoir, channel status)

Avoid hot-swapping to prevent electronic component damage

Clean module with a dry soft cloth only; do not use chemical cleaners

ABB 3BSE008508R1 DI810 is a high-performance, high-reliability 16-channel digital input module suitable for various industrial automation control systems. Its group-isolated design, wide input voltage range, and rich diagnostic functions make it an ideal choice for process control. For cross-brand replacement, attention must be paid to system compatibility, protocoles de communication, and isolation characteristics.

Liste complète des modèles & Cross-Brand Comparison for ABB S800 I/O Digital Input Modules

Key Overview

System: ABB S800 I/O Distributed Process I/O System, compatible with AC 800M, Freelance, etc..

Classification: By voltage type (24À DC / 48À DC / 120V et), channel count (8/16/32 channels), isolement (group isolation / individual isolation)

Principales fonctionnalités: Remplaçable à chaud, channel diagnostics, wide-temperature operation, DIN rail mountable

  1. Complete Model List of ABB S800 I/O Digital Input Modules

1.1 24V DC Series (Mainstream General-Purpose)

ModèleOrder No.ChannelsInput TypeIsolationTemps de réponsePrincipales fonctionnalitésApplications
DI8103BSE008508R116Sink/Source2 groups × 8 channels (500V et)Standard ≤1ms; High-speed ≤0.1msClassic general-purpose, group isolation, rich diagnosticsProcess control, automotive manufacturing, automation lines
DI8113BSE008516R116Sink/Source2 groups × 8 channels (500V et)Standard ≤1ms; High-speed ≤0.1ms48V DC compatible, high-density, flexible sensor compatibilityHigh-volume signal acquisition, 48Systèmes V CC
DI8143BSE008519R116Source2 groups × 8 channels (500V et)Standard ≤1msSource input, designed for PNP sensorsSensor signal acquisition, équipement d'automatisation
DI8183BSE008522R132Sink2 groups × 16 channels (500V et)Standard ≤1ms32-channel high-density, saves cabinet spaceLarge-scale signal monitoring, water treatment systems
DI8203BSE008512R18120V etIndividual channels (250V et)Standard ≤10msAC input, individual isolation, strong anti-interferenceÉquipement industriel, motor control, high-voltage signals
DI8213BSE008513R1848À DCIndividual channels (500V et)Standard ≤1msHigh-voltage DC, individual isolation, haute fiabilitéRail transit, power systems
DI8253BSE008514R11624À DCIndividual channels (500V et)Standard ≤1msIndividual channel isolation, precise diagnosticsSafety systems, critical signal monitoring

1.2 Special Function Series (Haut de gamme / Sécurité)

ModèleOrder No.Principales fonctionnalitésApplications
DI8303BSE012291R1SIL3 certified, channel-level redundancy, time stampingSafety Instrumented Systems (SIS), process safety control
DI8313BSE012292R1High-speed response (≤0.05ms), HART compatibleHigh-speed motion control, precision process control
DI8403BSE013234R1Intrinsically safe, for hazardous areas (Ex ia)Petrochemical, mining, flammable and explosive environments

1.3 Model Naming Convention

PartieSignificationExemple (DI810)
DIDigital Input ModuleDI = Digital Input
8S800 I/O Series Identifier8 = S800 Series
10Product code (24À DC, 16 channels, group isolation)10 = Basic general-purpose type
R1Hardware revision numberR1 = Initial version
  1. Cross-Brand Model Comparison (By Application Match)

2.1 Siemens Equivalent Models

Modèle ABBParamètres de baseSiemens EquivalentSystemDifférences clésReplacement Advice
DI810 (16DI, 24À DC, group isolation)16 channels, 24À DC, group isolation, 500V AC insulation6ES7131-4BD02-0AB0ET200SCommunication protocol (PROFIBUS vs PROFINET), diagnostic differencesFunctionally equivalent; configuration software adjustment required
DI818 (32DI, 24À DC, group isolation)32 channels, 24À DC, group isolation6ES7131-4BF00-0AA0ET200SPDouble channel count, different module sizeTwo ET200SP modules required
DI820 (8DI, 120V et, individual isolation)8 channels, 120V et, individual isolation6ES7131-4FF00-0AB0ET200SVoltage range, isolation methodSiemens AC input module required for 120V AC
DI830 (SIL3 certified)Safety-rated, channel redundancy6ES7521-1BH10-0AA0S7-1500FSafety certification level, system architectureMust meet SIL3 certification requirements

2.2 Rockwell Equivalent Models

Modèle ABBParamètres de baseRockwell EquivalentSystemDifférences clésReplacement Advice
DI810 (16DI, 24À DC)16 channels, 24À DC, sink/source compatible1734-IB8 ×2POINT I/OHalf channel count; two modules neededExtra module required, slightly higher cost
DI818 (32DI, 24À DC)32 channels, 24À DC, high-density1756-IB16 ×2ControlLogixCommunication interface (ControlNet vs PROFIBUS)Two modules, flexible expansion
DI820 (8DI, 120V et)8 channels, 120V et1794-IA8Flex I/OVoltage type, terminal styleFunctionally matched; wiring adjustment required

2.3 Schneider Equivalent Models

Modèle ABBParamètres de baseSchneider EquivalentSystemDifférences clésReplacement Advice
DI810 (16DI, 24À DC)16 channels, 24À DC, group isolationBMXDDI1602Modicon M340Communication protocol (Modbus TCP vs PROFIBUS)Functionally equivalent; different software platform
DI818 (32DI, 24À DC)32 channels, 24À DCBMXDDI3202KModicon M580Matching channel count, module dimensionsRemplacement direct; reconfiguration required
DI820 (8DI, 120V et)8 channels, 120V etABE701111Modicon PremiumVoltage range, isolation ratingSchneider AC input module required

2.4 Mitsubishi Equivalent Models

Modèle ABBParamètres de baseMitsubishi EquivalentSystemDifférences clésReplacement Advice
DI810 (16DI, 24À DC)16 channels, 24À DC, group isolationQX40Q SeriesCommunication interface (CC-Link vs PROFIBUS), diagnosticsFunctionally matched; bus module replacement required
DI818 (32DI, 24À DC)32 channels, 24À DCQX80Q SeriesChannel count, system architectureTwo QX80 modules required
DI820 (8DI, 120V et)8 channels, 120V etAY11A SeriesVoltage type, module typeMitsubishi AC input module required

2.5 Omron Equivalent Models

Modèle ABBParamètres de baseOmron EquivalentSystemDifférences clésReplacement Advice
DI810 (16DI, 24À DC)16 channels, 24À DC, group isolationCJ1W-ID211CJ SeriesCommunication interface (DeviceNet vs PROFIBUS), terminal styleFunctionally equivalent; system configuration adjustment required
DI818 (32DI, 24À DC)32 channels, 24À DCCS1W-ID211CS SeriesChannel count, system performanceTwo modules required, higher cost
DI820 (8DI, 120V et)8 channels, 120V etC200H-ID212C200HVoltage range, isolation methodOmron AC input module required
  1. Key Considerations for Replacement Selection

3.1 Core Matching Criteria

  1. Tension & Channels: Ensure input voltage and channel count match exactly to avoid signal damage or loss
  2. Isolation Method: Group isolation (ABB standard) vs. individual isolation (some Siemens/Mitsubishi models) affects interference immunity and safety rating
  3. Protocole de communication: PROFINET / PROFIBUS vs. Modbus / CC-Link; must match controller bus
  4. Termination Units: ABB requires TU810/TU812 etc.; cross-brand replacement needs redesigned terminal layout
  5. Diagnostics: ABB channel-level diagnostics vs. module-level diagnostics on other brands, affecting maintenance efficiency

3.2 Engineering Implementation Guidelines

PhaseKey Standards
InstallationMust mount on DIN rail; keep ≥30cm from heat-generating devices (inverters); 5mm clearance for cooling
CâblageUse shielded twisted-pair cable, shield grounded at one end; group common (COM) wiring to prevent short circuits
ConfigurationCross-brand replacement requires full project redevelopment; software incompatible (WinCC vs CX-Programmer vs Unity Pro)
EntretienRegularly check LED status (power/channel/fault); no hot-swapping for non-hot-swap modules

3.3 Priority Recommended Replacement Solutions

ApplicationPreferred ABB ModelCross-Brand AlternativeReason
Functional EquivalenceDI810 / DI814Siemens 6ES7131-4BD02-0AB0Exact match in channels, tension, and isolation
Cost OptimizationDI818 (32 channels)Rockwell 1756-IB16 ×2High density, rentable
Safety SystemsDI830Siemens 6ES7521-1BH10-0AA0SIL3 certified, channel redundancy
Hazardous AreasDI840 (intrinsically safe)Pepperl+Fuchs KFD2-STC4-EX1 + standard DI moduleIntrinsically safe isolation, explosion-proof compliance
  1. & Spare Parts List
  2. Full Range Coverage: ABB S800 I/O digital input modules cover 8–32 channels and 24V DC to 120V AC for all industrial scenarios
  3. Cross-Brand Compatibility: Equivalent models available from major brands; prioritize matching channels + tension + isolement, then protocol and diagnostics
  4. Spare Parts Recommendation: Stock DI810 (usage général), DI818 (high-density), DI820 (AC input) to cover over 80% of applications

Précédent:

Suivant:

Laisser une réponse

Laisser un message