Relais statique monophasé OMRON G3PA-240B-VD

Omron single-phase SSR, integrated heat sink, Montage sur rail DIN, zero-crossing type ✅ Model Code Explanation G3PA: G3PA series solid state relay with integrated heat sink 2: Output voltage class AC24~240V 40: Rated output current 40A B: Built-in heat sink, screw terminals VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light 📋 Key Specifications ...

  • Détails du produit

Omron single-phase SSR, integrated heat sink, Montage sur rail DIN, zero-crossing type

✅ Explication du code modèle

G3PA: Série G3PA solid state relay with integrated heat sink

2: Output voltage class AC24~240V

40: Rated output current 40A

B: Built-in heat sink, bornes à vis

VD: DC control input DC5~24V, phototriac isolation, zero-crossing, operation indicator light

📋 Spécifications clés

Côté entrée (Bornes de commande A1/A2)

Tension d'entrée nominale: DC 5~24V

Plage de tension de fonctionnement: DC 4~30V

Max.. courant d'entrée: 7mA (25℃)

Tension d'appel: ≤DC4V; Tension de chute: ≥DC1V

Côté sortie (Bornes de charge)

Load voltage: AC24 ~ 240 V, permissible range AC19~264V (50/60Hz)

Courant nominal: 40A @40℃; derate to 36A when tightly mounted side by side

Surge current withstand: 440UN (60Hz, 1 faire du vélo)

On-state voltage drop: ≤1.6V RMS

Courant de fuite: ≤20mA@AC200V

Trigger mode: Zero-cross switching (ideal for heating loads to reduce interference)

Isolement: Phototriac

Fonctionner / heure de sortie: ≤ half cycle +1ms

Environnemental & Mécanique

Montage: Rail DIN / montage à vis

Température ambiante: -30~+80℃ (pas de condensation ni de givrage)

Rigidité diélectrique: AC4000V 1min; résistance d'isolement ≥100MΩ (DC500V)

Terminaux: Bornes à vis

Certifications: UL, cUL, VDE, CE

📌 Applications typiques

Tubes de chauffage électrique, fours industriels, chauffage pour moulage par injection, équipement à air chaud, Contrôle de température ON/OFF pour charges résistives monophasées. Ne convient pas au PWM haute fréquence, uniquement pour les passages à zéro périodiques.

⚠️ Remarques importantes

  1. Utilisez un calibre de 40 A pour les charges résistives; charges inductives (moteurs, transformateurs) nécessitent un déclassement important.
  2. Lorsque plusieurs unités sont étroitement installées côte à côte, réduire le courant à 36 A en raison d'une mauvaise dissipation thermique.
  3. Type de passage à zéro: s'allume et s'éteint uniquement lorsque la tension alternative dépasse zéro. Il supprime les EMI mais ne peut pas commuter selon des angles de phase aléatoires.
  4. Entrée CC non polarisée; peut être piloté directement par un API ou un contrôleur de température avec une sortie DC5-24 V.
  5. Le SSR n'a pas de contacts mécaniques et ne peut pas fournir de protection contre les courts-circuits. Un fusible doit être installé en amont.

🔁 Même série & Modèles alternatifs

G3PA-220B-VD: 20UN / AC24-240V / DC5-24V

PDG du G3PA-260B: 60UN / AC24-240V / DC5-24V

G3PA-420B-VD: 20UN / AC200-400V / DC12-24V

Alternatives nationales: 40Un relais statique à passage zéro avec dissipateur thermique intégré. Vérifier la courbe de déclassement et l'indice de surtension avant le remplacement.

PDG du G3PA-240B (Passage à zéro, 40UN, Relais statique contrôlé DC5–24 V) Scénarios d'application

Positionnement de base: Contrôle de température ON/OFF pour charges résistives monophasées AC24-240V. Dissipateur thermique intégré sur rail DIN, piloté par des contrôleurs de température ou des automates. Conçu principalement pour les charges de chauffage, passage à zéro pour de faibles EMI, capable de changer fréquemment. Pas pour les charges PWM haute fréquence ou inductives telles que les moteurs.

🔥 Chauffage & Contrôle de la température (Utilisation principale)

  1. Fours industriels, fours à circulation d'air chaud, chambres de vieillissement, armoires à température constante, chambres d'essai à haute et basse température (tubes de chauffage électrique, tubes chauffants en quartz)
  2. Chauffage du fût de moulage par injection, chauffage de la matrice d'extrudeuse, chauffage de zone de machine de moulage par soufflage
  3. Presses à chaud, machines d'estampage à chaud, machines de transfert de chaleur, plaques chauffantes pour plastifieuses
  4. Machines d'emballage: thermoscelleuses, couteaux de coupe à chaud, chauffage du tunnel de rétraction
  5. Machines alimentaires: lignes de cuisson, séchoirs à air chaud, chauffage électrique pour cuisson des sauces, fours professionnels
  6. Traitement de l'eau: chaudières électriques, chauffage du réservoir, chauffage de traçage de tuyaux, chauffage de dégivrage
  7. Machines de vulcanisation, circuits de chauffage monophasés pour régulateurs de température de moules. (Pour chauffage triphasé, utiliser 3 unités séparément pour chaque phase.)

🧪 Équipement d'automatisation

  1. Chambres d'essais environnementaux, température constante & machines à humidité, sections de chauffage électrique des déshumidificateurs
  2. Semi-conducteur / Production de PCB: lignes de séchage, stations de préchauffage pour revêtement de colle
  3. Équipement de batterie au lithium: étuves à vide, chauffage d'armoire de formation
  4. Impression textile & teinture: machines de réglage, salles de séchage, chauffage à rouleaux chauds
  5. Machines à imprimer: tunnels de séchage, chauffage d'appoint pour systèmes UV

💡 Autre commutation de charge résistive

  1. Lampes halogènes haute puissance, banques de lampes chauffantes infrarouges (charges de lampes résistives)
  2. Radiateurs électriques de forte puissance pour armoires et salles blanches
  3. Modules de chauffage d'appoint électriques pour climatisation / systèmes d'air frais

Avantage: La commutation par passage à zéro réduit le courant d'appel et les interférences avec les instruments de température, PLCs and power grid.

✅ Suitable Working Conditions

Commutation fréquente (several to tens of times per minute), avoid contact burnout and arcing of contactors

Driven by PID temperature controllers or PLC digital outputs (DC24V)

DIN rail installation inside control cabinets, espace compact, dissipateur thermique intégré, no extra heat sink required

Isolement élevé (4rigidité diélectrique kV) and operation indicator for easy commissioning

Single-phase resistive heating loads, principalement AC220V, current ≤40A (derate to 36A when densely mounted)

❌ Applications non recommandées (Pièges de sélection)

AC motors, pompes à eau, transformers and other inductive loads: high starting surge may cause breakdown. Heavy derating or random-phase SSR / contactor is preferred.

High-frequency PWM dimming (tens of Hz or above): zero-cross SSR cannot perform phase-angle regulation.

Charges capacitives.

OMRON G3PA-240B-VD Selection Guide & Notes d'application (Product Page Version, Chinois + Anglais)

Optimized for bestcontactor foreign trade website, readable for engineers, buyers and procurement, E-E-A-T compliant.

  1. Liste de contrôle de sélection – Confirmez les 4 Articles avant de choisir G3PA-240B-VD

✅ Type de charge: Charge résistive monophasée préférée (tubes chauffants, radiateurs infrarouges, plaques chauffantes)

✅ Tension de charge: C.A. 24 ~ 240 V (AC220V le plus courant)

✅ Signal de contrôle: DC 5~24V (API DO, Sortie du contrôleur de température PID)

✅ Montage: Rail DIN à l'intérieur de l'armoire, integrated heat sink

Si vous n’êtes pas satisfait – Alternatives recommandées

  1. Charges inductives (moteurs, électrovannes, transformateurs)

Non recommandé pour ce modèle. Utilisez des contacteurs ou un SSR à phase aléatoire avec au moins 50% déclassement actuel.

  1. 3-charges de chauffage de phase

Solution: 3 pcs G3PA-240B-VD pour contrôler chaque phase indépendamment. N'utilisez pas une seule unité pour une charge triphasée.

  1. Régulation de puissance, gradation d'angle de phase, PWM haute fréquence

G3PA est un SSR à passage zéro, uniquement pour le contrôle du cycle ON/OFF, pas de modulation d'angle de phase. Choisissez les contrôleurs de puissance OMRON G3PW si une régulation est nécessaire.

  1. Courant de charge proche de 40A en continu, plusieurs unités étroitement disposées

Derate to 36A for dense mounting. Upgrade to G3PA-260B-VD (60UN) if load current is continuously above 36A.

Load Current Formula (for foreign trade page)

Safe current for resistive load = rated load current × 1.25 marge de sécurité

Multiply by 0.9 derating factor if densely mounted

Exemple: 3000W @AC220V heating tube, current ≈13.6A, sufficient margin for G3PA-240B-VD.

  1. Guide de câblage (Concise for Product Page)

Saisir (contrôle): A1, A2, DC5~24V, non polarisé

Sortir (charger): power in, charger; AC side non-polarized

Built-in operation indicator: lights up when control signal is present for easy on-site commissioning

Indice d'isolement: AC4000V between input and output

Important: Fast fuse must be installed on upstream AC side. SSR cannot withstand short circuit and will be permanently damaged.

  1. Notes d'application
  2. Dissipation thermique & Déclassement

This model has integrated heat sink. Heat dissipation worsens at high cabinet temperature or when tightly mounted side by side; rated 40A derates to 36A. Keep ventilation inside cabinet. L'installation scellée sans flux d'air est interdite.

  1. Caractéristique de passage à zéro

Le SSR s'allume et s'éteint uniquement lorsque la tension alternative dépasse zéro. Avantages: faible courant d'appel et faible EMI. Limitation: ne peut pas commuter à un angle de phase arbitraire, pas pour la gradation ou le contrôle de phase.

  1. Courant de fuite

Petit courant de fuite résiduel (≤20mA @AC200V) existe à l'état OFF. De petites charges peuvent montrer un léger échauffement ou une lueur, ce qui est normal pour la RSS. Une résistance de purge peut être ajoutée pour résoudre ce problème.

  1. Surtension de charge

Les lampes infrarouges et les tubes à quartz ont une faible résistance au froid avec un courant d'appel élevé à la mise sous tension. Ce modèle résiste à 440A (60Hz, 1 faire du vélo). Sélectionnez un courant nominal plus élevé si la surtension dépasse cette valeur.

  1. Conditions ambiantes

Température de fonctionnement: -30℃ ~ +80℃, pas de gaz corrosif, condensation ou accumulation de poussière. La poussière et l'huile obstrueront le dissipateur thermique et accéléreront le vieillissement.

  1. Opérations interdites

Ne pas tester le court-circuit de sortie; ne pas utiliser directement pour des charges capacitives; éviter les charges inductives qui surgissent fréquemment.

  1. Éléments de support recommandés

Fusible: fusible rapide en céramique

Contrôleur de température: OMRON E5CC / Contrôleur PID E5EC

Modèles alternatifs: G3PA-220B-VD (20UN), PDG du G3PA-260B (60UN)

Mise à niveau pour la régulation de puissance: Contrôleur de puissance série G3PW

  1. FAQ (pour le bas de la page produit)

Q: Le G3PA-240B-VD peut-il contrôler les moteurs?

UN: Non recommandé. Le relais statique à passage par zéro a une tenue limitée aux surtensions et peut tomber en panne sous le courant de démarrage du moteur.. Le contacteur AC est préférable.

Q: Pourquoi le tube chauffant est-il encore légèrement chaud après l'extinction du SSR?

UN: Cela est dû au courant de fuite inhérent au SSR., plus évident sur les petites charges. Ajouter une résistance de purge.

Q: Peut-il être piloté directement par la sortie PLC DC24V?

UN: Oui. La consommation d'énergie d'entrée est faible (environ. 7mA), les points de sortie PLC standard peuvent le piloter.

Relais statique OMRON série complète SSR (Version de sélection du commerce extérieur, Classifié, dont G3PA)

Classification: Dissipateur thermique intégré type rail DIN (premier choix pour le chauffage des armoires), type de dissipateur thermique séparé, détection de défauts SSR, Relais statique miniature E/S enfichable, contrôleur de puissance (pas de SSR régulier, souvent sélectionnés ensemble), modèles abandonnés marqués.

  1. Dissipateur thermique intégré Rail DIN SSR (Le plus courant pour le chauffage, dont G3PA)
  2. G3PA (Type intégré mince, module d'alimentation remplaçable)

Monophasé, 24 à 240 V CA / 200 à 480 V CA, Contrôle DC5–24 V, zero-crossing

G3PA-210B-VD: 10UN

G3PA-220B-VD: 20UN

PDG du G3PA-240B: 40UN (ce modèle)

PDG du G3PA-260B: 60UN

G3PA-420B-VD: 20UN, Version 480 V CA

G3PA-430B PDG: 30UN, Version 480 V CA

G3PA-450B-VD-2: 50UN, Version 480 V CA

✅ Utilisation typique: fours, chauffage pour moulage par injection, machines de température de moule, Contrôle de température PID ON/OFF

  1. G3PE (Nouveau type intégré compact, monophasé & 3-phase)

Monophasé: G3PE-215B / 225B / 235B / 245B; 3-Phase G3PE-325B, G3PE-345B

Avantages: meilleure tolérance aux surtensions, version à phase aléatoire disponible, adapté à certaines charges inductives et à gradation

Montage: Rail DIN, monophasé / 3-circuits de chauffage par phases

  1. G3PJ (Type de montage à faible densité thermique, 25Une note reste valable même 3 unités étroitement côte à côte)

G3PJ-225B, G3PJ-225B-PU (Borne à ressort enfichable)

Pour armoires de commande haute densité avec chauffage multizone

  1. G3PH (Type intégré à courant élevé)

75UN / 150UN, AC240V, AC480V, pour charges de chauffage élevées

  1. G3PC (SSR avec détection de défauts intégrée)

Détection de rupture de chauffage et sortie d'alarme de court-circuit SSR. Safety-critical heating control, preferred for test chambers and lithium battery ovens.

  1. G3PF (Smart CT current sensing SSR)

Built-in current transformer for real-time heating element break and short-circuit detection. For high-end equipment with alarm logging.

  1. Separate Heat Sink Type (No built-in heat sink, embedded installation, external heat sink required)
  2. G3NA (Classic universal model, large market stock)

Monophasé, 5A~90A, mainly zero-crossing

G3NA-205B / 210B / 220B / 240B / 260B

G3NA-410B / 420B / 440B / 460B (AC480V)

G3NA-290B (90Un courant élevé)

Suffixe: -VD = DC5–24V control; models without B are random-phase type

  1. G3NE (Economical low-current, 5A/10A/20A, quick connect terminals)

Faible coût, small heating loads, lampes infrarouges, embedded inside machines

  1. Plugin / I/O Mini SSR (Same footprint as MY/LY relays, signal and small load switching)

G3F / G3FD: MY relay size, socket mount, small AC/DC loads

G3H / G3HD: LY power relay size

G3R-I/O: G2R footprint I/O isolation SSR

G3RV-ST: 6.2mm slim DIN rail I/O SSR, high-density PLC isolation output

G3TA: SSR matched with G7TC I/O terminal blocks

G3RZ: MOSFET type, AC/DC low-power loads

  1. Power Controllers (Power regulators, not regular ON/OFF SSR)

Phase angle control, contrôle des cycles, soft start, for continuous power regulation

G3PW: Single-phase power controller (widely used for regulation instead of SSR)

G3ZA: Multi-channel power controller

G32A-EA: Cycle control unit

  1. PCB Mount SSR (Soldered on PCB, commutation de signaux)

G3S, G3M, G3DZ, G3TB etc. Faible courant, signal isolation, used inside control boards

  1. Modèles abandonnés (Frequently asked in foreign trade inquiries)

G3PB, G3NH, G3B/G3BD, old G3RV-SR. Not recommended for new designs; only for spare replacement.

✅ Quick Selection Table (Can be placed directly on product page)

SérieHeat Sink TypePlage actuellePrincipales fonctionnalitésApplications typiques
G3PAIntegrated DIN rail10~60AMince, zero-crossing, replaceable power coreMoulage par injection, fours, general heating
G3PEIntegrated DIN railCélibataire / 3-phase 15~45ABetter surge resistance, random-phase optionChauffage, partial inductive loads
G3PJIntegrated DIN rail25UNNo derating when densely mountedMulti-zone dense control cabinets
G3PHIntegrated DIN rail75/150UNExtra high currentChauffage haute puissance
G3PC / G3PFIntegrated DIN rail25~45AFault detection & alarmeLithium battery ovens, chambres de vieillissement, safety-critical equipment
G3NASeparate heat sink5~90AUniversel, rentableEmbedded inside machines, external heat sink required
G3NESeparate heat sink5~20AÉconomiqueLow-power heating
G3PWPower regulator–Phase / cycle power controlContinuous temperature regulation

📌 Suffix Meaning (FAQ for Foreign Trade)

VD: DC5~24V non-polarized DC input (G3PA-240B-VD uses this suffix)

B: Zero-crossing trigger

No B: Random-phase trigger (phase-angle switching, adapté aux charges inductives)

Unité centrale: Borne à ressort enfichable

-2: 480Version V