ABB 3BSE038415R1 (AO810V2) Analog Output Module

It is an 8-channel analog output module of the S800 I/O series for ABB Advant 800xA system. It converts digital control signals into standard industrial analog signals (0/4-20mA or 0-10V) to drive on-site equipment such as actuators and valves. Définition du segment du modèle (ABB S800 I/O Naming Rule) Model Segment Meaning Detailed Description 3BSE Product series ...

  • Détails du produit

C'est un 8-channel analog output module of the S800 I/O series for ABB Advant 800xA system. It converts digital control signals into standard industrial analog signals (0/4-20mA or 0-10V) to drive on-site equipment such as actuators and valves.

  1. Définition du segment du modèle (ABB S800 I/O Naming Rule)
Segment de modèleSignificationDescription détaillée
3BSEProduct series prefixGeneral prefix for ABB industrial automation products, representing control system I/O modules
38415Product part numberNumeric code for unique module identification
R1Revision numberRevision 1, standing for the first official version of the module
AO810V2Commercial modelAO = Analog Output, 8 = 8 chaînes, 10 = Standard type, V2 = 2nd generation upgraded version
  1. Spécifications techniques de base (Official Data)
Catégorie de paramètreTechnical IndexRemarques
Basic Characteristics
Number of Channels8 chaînes (galvanically isolated)Each channel can be individually configured for output type
Type de sortieActuel / Voltage selectable0-20mA, 4-20mA, 0-5V, 1-5V, 0-10V
Résolution14-peu (y compris le bit de signe)Accuracy ±0.1% Full Scale
Conversion Rate25ms per channelFull channel update cycle: 200MS
Paramètres électriques
Current Output Range0-25mA (Maximum drive capability)Standard load 500Ω (4-20mA), High load 850Ω (0-20mA)
Voltage Output Range0-10VMinimum load 1kΩ
Isolation Level250V AC between channels, 500V AC between channel and backplaneConforme à la CEI 61010-1 safety standard
Alimentation24À DC (±10%)Power consumption <2W
Paramètres environnementaux
Température de fonctionnement0°C à +55°CTempérature de stockage: -20°C à +70°C
Humidité5% à 95% (Non-condensing)Niveau de protection IP20
Vibration / Choc5g / 11MS (Half-sine wave)Meet anti-interference requirements for industrial environments
Certifications & ConformitéCE, UL, ASCCompliant with EN 61131-2, CEI 61010-1
  1. Liste des accessoires & Exigences d'installation

3.1 Mandatory Accessories (Must Be Used Together)

Part NumberNomFonction
TU810/TU812/

TU814/TU830/

TU833

Terminal UnitProvide field wiring terminals for signal connection and isolation
TB810Terminal BoardFacultatif, for high-density wiring scenarios
SD811Shield ConnectorFor analog signal shield grounding and interference reduction

3.2 Spécifications d'installation

Montage sur rail DIN: 35mm standard rail complying with DIN EN 50022

Backplane Communication: Communicate with controller via S800 I/O bus backplane

Installation Clearance: Keep at least 10mm gap between modules for heat dissipation

Wiring Requirement: Use shielded twisted pair for analog signals, routed separately from power cables (spacing ≥15cm)

  1. Same Series Models & Liste de remplacement multi-marques

4.1 ABB S800 I/O Analog Output Module Series

ModèleChannelsRésolutionFonctionnalités spécialesScénarios d'application
AO810V2 (3BSE038415R1)814-peuModèle standard, general outputContrôle industriel général, rentable
AO815V2816-peuHigh precision with diagnostic functionProcess control requiring high measurement accuracy
AO820414-peuRedundant output, sécurité intégréeCritical equipment control with redundant backup required
AO890814-peuHART protocol supportSmart instrument communication and remote diagnosis

4.2 Cross-Brand Replacement Solution (Parameter Matching)

MarqueModèleChannelsRésolutionType de sortieRemarque sur la compatibilité
SchneiderBMXDAI1605814-peu0/4-20mA, 0-10VAdaptable to Modicon M340/M580 system
Siemens6ES7 332-5HF00-0AB0814-peu0/4-20mA, 0-10VCompatible with S7-300 system, backplane replacement required
Rockwell1756-OF8816-peu0/4-20mA, 0-10VFor ControlLogix system, different communication protocol
DomestiqueHollySys FM148A814-peu0/4-20mA, 0-10VCompatible with LK series DCS, performance à coût élevé
  1. Lignes directrices de sélection & Replacement Tips

5.1 Selection Decision Tree (Quick Demand Matching)

  1. Channel Quantity: 8 channels satisfy most small and medium control loops; expand by parallel installation or select 16-channel models for more points.
  2. Accuracy Requirement:

General control: AO810V2 (0.1% précision) is sufficient

Precision control: Upgrade to AO815V2 (16-peu, 0.05% précision)

  1. Capacité de charge:

Standard load (≤500Ω): Directly use AO810V2

High load (500-850Oh): Adopt 0-20mA mode instead of 4-20mA

  1. Fonctions spéciales:

HART communication: Choose AO890

Redundant output: Choose AO820

Fail-safe: Choose AO825 (SIL certified)

5.2 Replacement Mnemonic Rule (3 Key Matching Elements)

Same channel quantity, no accuracy downgrade, meet load requirement, equivalent isolation performance

5.3 Replacement Precautions

  1. Compatibilité du protocole: ABB S800 I/O adopts Profibus DP or ABB dedicated bus; cross-brand replacement requires system compatibility evaluation.
  2. Terminal Compatibility: Terminal units of different brands are not interchangeable and shall be replaced together.
  3. Configuration du logiciel: Reconfigure module parameters after replacement to ensure consistent output range and fail-safe logic.
  4. Redundant System: Conduct compatibility testing first for critical applications to avoid system failure.
  5. Main Application Scenarios & Cas typiques
  6. Process Industry: Valve positioner control in chemical, petrochemical and natural gas processes
  7. Power Industry: Generator excitation control and transformer tap changer regulation
  8. Fabrication: Production line speed control, pression / flow regulation
  9. Water Treatment: Pump inverter control and chemical dosing flow regulation

Typical configuration: AO810V2 module + TU812 terminal unit + SD811 shield connector, used to control 4-20mA pneumatic regulating valves for precise flow control.

Full List of ABB Analog Output Modules (Structured Quick Reference)

  1. S800 I/O Series (800xA/DCS System, Industrial Standard Application)
Module ModelFull Part NumberChannelsFonctionnalités principalesType de sortieRésolutionApplication typique
AO8013BSE020514R18Type de base, channel isolation0/4-20mA, 0-10V12-peuGeneral control, low-cost scenarios
AO8103BSE008522R18Standard configurable type0/4-20mA, 0-5V, 1-5V, 0-10V14-peuContrôle industriel général, medium precision
AO810V23BSE038415R1/R28V2 upgraded version, higher stability0/4-20mA, 0-5V, 1-5V, 0-10V14-peuReplacement for AO810, mainstream application
AO810V2-eA3BSE038415R28Optimized for Freelance system0/4-20mA, 0-10V14-peuFreelance DCS system
AO8153BSE008523R18High precision with diagnosis0/4-20mA, 0-10V16-peuProcess control & precision regulation
AO8203BSE008546R14Redundant output, sécurité intégrée0/4-20mA14-peuCritical equipment control with redundancy
AO8453BSE008547R18Redundant output with OSP preset value0/4-20mA14-peuSafety-related systems, communication fault protection
AO845A3BSE018107R18AO845 upgrade, HART pass-through0/4-20mA14-peuSmart instrument communication & diagnostic à distance
AO8903BSE008548R18Intrinsically safe, HART0/4-20mA (Ex ia)14-peuHazardous Area Zone 1/2, explosion-proof required
AO8953BSE018108R18High precision intrinsically safe0/4-20mA (Ex ia)16-peuPrecision control in hazardous areas
  1. S900 I/O Series (ATEX Explosion-Proof for Hazardous Areas)
Module ModelFull Part NumberChannelsExplosion-Proof GradeFonctionnalités principalesType de sortieZone Applicable
AO920S3KDE175531L92004Ex ia IIC T4Isolated, intrinsèquement sûr0/4-20mAZone 1/2, no HART required
AO920N3KDE175533L92004Ex ia IIC T4Non-isolated, intrinsèquement sûr0/4-20mAZone 1/2, priorité aux coûts
AO920B3KDE175532L92004Ex ia IIC T4Enhanced isolated, intrinsèquement sûr0/4-20mAZone 1/2, high anti-interference
AO930S3KDE175531L93004Ex ia IIC T4Isolated with HART0/4-20mAZone 1/2, smart instrument connection
AO930N3KDE175533L93004Ex ia IIC T4Non-isolated with HART0/4-20mAZone 1/2, HART + priorité aux coûts
AO930B3KDE175532L93004Ex ia IIC T4Enhanced isolated with HART0/4-20mAZone 1/2, HART + high anti-interference
DSAX4523KDE175534L94528Ex ia IIC T4High-density, intrinsèquement sûr0/4-20mAZone 1/2, multi-channel demand
  1. AC500 PLC S500 Series (Modular PLC Application)
Module ModelFull Part NumberChannelsFonctionnalités principalesType de sortieRésolutionProcesseur compatible
AO5231SAP250200R000116High density, software configurable0/4-20mA, 0-10V, ±10 V12-peuPM5xx series, AC500-eCo
AO5621SAP250201R00014Haute précision, réponse rapide0/4-20mA, 0-10V, ±10 V16-peuPM5xx series, high-performance application
AX5211SAP250100R00014AI/4AOMixed I/O, gain de place0/4-20mA, 0-10V12-peuCompact system with limited I/O points
AX5221SAP250101R00018AI/8AOHigh-density mixed I/O0/4-20mA, 0-10V, Pt10012-peuMedium system with multi-function demand
500MBA021MRB150003R00018Type de base, rentable0/4-20mA, 0-10V12-peuAC500 basic series
  1. Other Series (Special Application Scenarios)

4.1 Advant Master Series

Module ModelPart NumberChannelsCaractéristiquesApplication
AO8003BSE008521R18Basic analog outputAdvant Master DCS system

4.2 Safety-Related Modules (SIL Certified)

Module ModelPart NumberChannelsSIL LevelCaractéristiquesApplication
AO8253BSE018109R14SIL 2Fail-safe, redundant outputSafety Instrumented System (SIS)
  1. Selection Mnemonic & Comparaison des paramètres clés

5.1 Selection Rule

System Matching → Channel Quantity → Accuracy → Explosion-Proof → Special Functions

System Matching: S800 for 800xA, S900 for explosion-proof, AC500 for PLC

Channel Quantity: 4/8/16 channels selected by control loop quantity

Précision: 12-peu (Basique), 14-peu (Standard), 16-peu (Precision)

Explosion-Proof: Non-explosion-proof (S800), Intrinsically safe (S900)

Fonctions spéciales: HART (AO845A/AO890/AO930), Redundant output (AO820/AO845), Fail-safe (AO825)

5.2 Key Parameter Comparison Table

SérieTypical AccuracyMax Load (4-20mA)Isolation LevelOperating TempRedundancy Support
S800±0,1%500Oh (Standard) / 850Oh (Haut)250V AC between channels0-55℃Partial models (AO820/AO845)
S900±0,1%750OhEx ia IIC-20-60℃Facultatif
AC500±0.2%600Oh500V AC between channels0-60℃Non
  1. Instructions & Remarques
  2. Règle de dénomination du modèle:

AO = Analog Output

Digit = Channel quantity (par exemple. 8 = 8 chaînes)

Suffix V2 = 2nd generation upgraded version

Suffix S/B/N (S900) = Isolated / Enhanced Isolated / Non-isolated

Suffix -eA = Optimized for Freelance system

  1. Correspondance des accessoires:

S800 series: Match with TU810/TU812/TU814/TU830/TU833 terminal units

S900 series: Match with SA910S/SA920S terminal units

AC500 series: Direct DIN rail mounting with integrated terminals

  1. Replacement Principle:

Higher version can replace lower version within the same series (AO810V2 replaces AO810)

Cross-series replacement requires system and protocol compatibility check

Accuracy and channel quantity shall not be lower than original module

Selected Application Cases of ABB Analog Output Modules (Full Industry Coverage + Configuration & Value Dimension)

  1. Pouvoir & Energy Industry (Mainly S800 I/O, Haute fiabilité & Redundancy Demand)

1.1 Thermal Power Plant Boiler Combustion Control System (AO810V2+AO845A)

End User: Large state-owned power plant (600MW unit)

Configuration de base:

Main Controller: AC800M redundant controller (PM865)

Sortie analogique: 8 pcs AO810V2 (feed water regulating valve, forced/draught fan inverter control) + 2 pcs AO845A (fuel valve redundant output)

Terminal Unit: 10 pcs TU812 + SD811 shield connector

Realized Functions:

Precisely control boiler feed water flow, air flow and fuel supply via 4-20mA signals to optimize combustion efficiency (excess air factor controlled at 1.15-1.2)

AO845A redundant output keeps fuel valve at safe opening during communication failure, conforme à la CEI 61850

Real-time regulation of turbine inlet valve to match grid load demand

Customer Benefits:

Boiler efficiency increased by 2.3%, économiser sur 12,000 tons of standard coal annually

NOₓ emission reduced by 18%, meeting ultra-low emission standard

System availability up to 99.99%, reducing unplanned shutdowns

1.2 Wind Farm Pitch Control System (AO815+AO820)

End User: Multinational wind power operator (100MW wind farm)

Configuration de base:

Pitch Controller: AC800M + 3 pcs AO815 (high-precision pitch angle control) + 3 pcs AO820 (redundant safety chain output)

Signal Type: 0-10V (pitch motor servo control) + 4-20mA (safety brake control)

Realized Functions:

Dynamically adjust blade angle (0-90°) according to wind speed and grid frequency to maximize wind energy capture

16-bit high precision of AO815 ensures pitch angle control error <0.1% and improves power generation efficiency

AO820 redundant output triggers safety brake rapidly in emergency to guarantee equipment safety

Customer Benefits:

Annual power generation increased by 3.2%, revenue increased by about 2.1 million CNY

Blade fatigue damage reduced by 25%, service life extended

Compliant with GL 2010 wind power safety standard and TÜV certified

  1. Industrie pétrochimique (S800/S900, Explosion-Proof & High Precision Demand)

2.1 Refinery Distillation Column Control System (AO810V2+AO890)

End User: Integrated refining & chemical enterprise (10 million tons/year refining capacity)

Configuration de base:

Distillation Unit: 800xA system + 6 pcs AO810V2 (reflux pump inverter, reboiler steam valve control) + 2 pcs AO890 (tower bottom temperature control for hazardous area)

Explosion-Proof Level: AO890 meets Ex ia IIC T4 for Zone 1 hazardous area

Realized Functions:

Precisely control reflux ratio (0.5-3.0) and tower bottom temperature ( ±0.2°C ) to maintain mass and energy balance

HART function of AO890 realizes remote diagnosis of smart valve positioner and early warning of sticking fault

MPC algorithm optimizes product purity through analog output modules

Customer Benefits:

Gasoline product purity increased by 0.5 percentage points, annual premium income about 8 million CNY

Steam consumption reduced by 12%, annual energy cost saving about 3.5 million CNY

Unplanned shutdown reduced by 4 times per year, avoiding loss of about 20 million CNY

2.2 Chemical Reactor Temperature & Pressure Control (AO815+AO845A)

End User: Fine chemical enterprise (pesticide intermediate production)

Configuration de base:

Reactor Control: AC800M + 4 pcs AO815 (heating/cooling system control) + 2 pcs AO845A (pressure regulating valve redundant output)

Type de sortie: 4-20mA (commande de vanne proportionnelle) + 0-10V (heating power control)

Realized Functions:

Temperature control accuracy up to ±0.1°C, pressure control accuracy ±0.02MPa, meeting fine chemical synthesis requirements

AO815 diagnostic function monitors valve status in real time and early warns leakage risk

Precisely control feeding rate and reaction time in batch production to improve product consistency

Customer Benefits:

Product yield increased from 92% à 99.5%, reducing waste disposal cost

Reaction cycle shortened by 15%, annual production capacity increased by 20%

Safety risk reduced and passed HAZOP analysis certification

  1. Manufacturing Industry (S800/AC500, Configuration flexible & Réponse rapide)

3.1 Automotive Painting Workshop Precision Control (AO815)

End User: Joint venture automobile manufacturer (300,000 vehicles annual output)

Configuration de base:

Painting Line: 800xA system + 12 pcs AO815 (12 sets of painting valves and coating transfer pump control)

Signal Type: 4-20mA (coating flow control, accuracy 0.01L/min)

Realized Functions:

Dynamically adjust nozzle flow based on vehicle 3D model data to achieve uniform coating thickness (±5μm)

HART communication monitors valve status in real time and early warns blockage or wear

Synchronize with robot trajectory to ensure painting quality on complex curved surfaces

Customer Benefits:

Coating rework rate reduced by 8%, annual coating cost saving about 4.5 million CNY

Production tact improved by 10%, annual capacity increased by 30,000 vehicles

VOCs emission reduced by 12%, meeting environmental standards

3.2 PV Module Laminator Temperature Control (AO810V2)

End User: Leading PV enterprise (5GW module annual output)

Configuration de base:

Laminator: AC500 PLC + 4 pcs AO810V2 (8 heating zones, 2 channels per module in parallel)

Type de sortie: 0-10V (heating power control, 14-bit resolution)

Realized Functions:

PID algorithm precisely controls heating plate temperature with uniformity ±0.5°C to ensure full cross-linking of EVA film

Automatically compensate heat loss by monitoring temperature difference of each heating zone

Link with vacuum system to realize precise control of pressure-temperature-time

Customer Benefits:

Module yield increased from 92% à 98%, annual loss reduction about 60 million CNY

Energy consumption reduced by 18%, annual electricity saving about 2.8 million CNY

Equipment maintenance cycle extended by 50%, réduire les temps d'arrêt

  1. Water Treatment & Environmental Protection Industry (AC500/S800, Energy Saving & Stable Operation)

4.1 Municipal Wastewater Treatment Plant Aeration System (AO810V2+AC500)

End User: Municipal wastewater treatment plant (500,000 tons daily treatment capacity)

Configuration de base:

Aeration Tank Control: AC500 PM573 + 6 pcs AO810V2 (12 Roots blower inverter control)

Control Logic: PID regulation based on dissolved oxygen (FAIRE) concentration (2-4mg/L)

Realized Functions:

Dynamically adjust blower speed according to inlet water quality and flow to precisely control aeration volume

Alternate operation of multiple blowers to balance equipment wear and extend service life

Link with online water quality analyzer to realize precise aeration and avoid over-oxygenation

Customer Benefits:

Blower energy consumption reduced by 25%, annual electricity saving about 1.8 million CNY

Sludge production reduced by 15%, lowering treatment cost

Effluent quality stably meets Class 1-A standard of GB 18918-2002

4.2 Waterworks Chemical Dosing System (AO523+AC500-eCo)

End User: County-level water supply company (100,000 tons daily water supply)

Configuration de base:

Dosing Room: AC500-eCo + 2 pcs AO523 (16 chaînes, CAP & PAM dosing pump control)

Type de sortie: 4-20mA (dosing pump frequency control, 0-50Hz)

Realized Functions:

Automatically calculate dosing amount based on raw water turbidity, pH and flow for precise dosing control

Link with sedimentation tank liquid level and effluent turbidity to realize closed-loop control

Historical data recording and trend analysis to optimize dosing strategy

Customer Benefits:

Chemical consumption reduced by 12%, annual cost saving about 350,000 CNY

Effluent turbidity stably below 0.5NTU, improving water supply quality

Manual operation reduced and labor intensity lowered

  1. Metallurgical Industry (S800, High Load & Anti-Interference)

5.1 Steel Hot Rolling Reheating Furnace Control (AO810+AI810)

End User: Large iron & steel group (hot rolled coil production line)

Configuration de base:

Reheating Furnace: AC800M redundant controller + 5 pcs AO810 (gas flow valve & air flow valve control) + 5 pcs AI810 (temperature acquisition)

Type de sortie: 4-20mA (proportional regulating valve control, load 800Ω)

Realized Functions:

Zoned furnace temperature control (1200-1250°C) with temperature deviation within ±5°C

Optimize air-fuel ratio (1.05-1.1) to improve combustion efficiency and reduce NOₓ emission

Link with rolling mill speed to realize precise billet temperature control

Customer Benefits:

Furnace thermal efficiency increased by 3%, annual gas cost saving about 5 million CNY

Steel billet oxidation loss reduced by 0.2%, annual output increase about 12,000 tonnes

Product thickness tolerance improved from ±0.15mm to ±0.08mm, upgrading product quality

  1. Application Selection Key Points (Sélection & Value Dimension)

6.1 Module Selection Matching Table

IndustrieCore DemandRecommended ModulePrincipales fonctionnalités
PouvoirRedundancy & Haute fiabilitéAO845A/AO820Redundant output, sécurité intégrée, CEI 61850 compliant
ChimiqueExplosion-Proof & High PrecisionAO890/AO815Intrinsically safe, 16-bit precision, HART communication
FabricationRéponse rapide & UniformityAO815/AO810V2Réponse rapide, 14/16-bit precision, channel isolation
Water TreatmentEnergy Saving & StabilitéAO810V2/AO523Multi-channel, faible consommation d'énergie, PID optimization
MétallurgieHigh Load & Anti-InterferenceAO810850 high load capacity, 500V isolation

6.2 Core Value Formula

Application Value = Quality Improvement from Higher Precision + Cost Saving from Energy Reduction + Downtime Loss Reduction from Higher Reliability

6.3 Key Success Factors for Implementation

  1. System Matching: S800 for 800xA/DCS, AC500 for PLC, S900 for explosion-proof areas
  2. Accessoires complets: Terminal unit (TU810/812/830) + shield connector (SD811) are essential
  3. Parameter Optimization: Select current/voltage output according to load type and set proper fail-safe value
  4. Diagnosis Utilization: Enable HART function for predictive maintenance and lower operation cost

 